The Recall Desk

Hazard

Brake Failure recalls

1,092 recalls in our database tag this hazard, drawn from FDA, USDA FSIS, CPSC, and NHTSA source notices.

What the numbers show

Total
1,092
Critical
0
Severe
843
Most recent
2026-10-20

Of the 1,092 brake failure recalls we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 843 (77%) are Severe.

Which agencies issued them

About this hazard tag

Hazard tags are short, machine-readable labels we attach to every recall to make cross-cutting queries possible — “all brake failure recalls regardless of agency”, “all listeria recalls in California”, “all airbag recalls in 2025”. The tags are extracted from each recall’s source text during the LLM rewrite step and validated against a fixed schema.

A recall can carry multiple tags — a Listeria recall might also be tagged ready-to-eat and undeclared-allergen. Use the full-text search if you want to combine hazard tags with brand or category filters.

326–350 of 1092

  • SevereNHTSA·20V808000·2020-12-22

    GM Recalls 2020 Chevrolet Bolt EV for Brake Caliper Fracture Risk

    General Motors is recalling 2020 Chevrolet Bolt EV vehicles because a front left brake caliper may fracture, potentially reducing brake performance and increasing crash risk.

    Product
    CHEVROLET — CHEVROLET BOLT EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V802000·2020-12-21

    Mercedes-Benz and Freightliner Sprinter Vehicles Recalled for Brake Fluid Leak

    Daimler Vans USA is recalling 2019-2020 Mercedes-Benz and Freightliner Sprinter vans because rear brake calipers may leak fluid, allowing air into the hydraulic brake system.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ, FREIGHTLINER SPRINTER 3500, SPRINTER 2500, SPRINTER 4500, SPRINTER 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V787000·2020-12-16

    2021 Thomas Built Saf-T-Liner C2 Electric School Bus Brake Recall

    Daimler Trucks North America is recalling 28 electric school buses where the parking brake may release unexpectedly, increasing crash risk.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER C2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V741000·2020-11-30

    Mitsubishi Recalls 2016 Outlander Models for Parking Brake Corrosion Risk

    Mitsubishi is recalling 2016 Outlander and Outlander Sport vehicles because rust prevention coating on parking brake shafts may peel, causing corrosion and potential brake failure.

    Product
    MITSUBISHI — MITSUBISHI OUTLANDER SPORT, OUTLANDER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V739000·2020-11-25

    Peterbilt 520 Recalled for Incorrect Brake Relay Connections

    PACCAR is recalling 2020-2021 Peterbilt 520 vehicles because incorrectly connected brake components may destabilize the vehicle during stability control events, increasing crash risk.

    Product
    PETERBILT — PETERBILT 520
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V714000·2020-11-18

    Alfa Romeo Giulia Recall for Rear Brake Disc Fracture Risk

    FCA US LLC is recalling 2020 Alfa Romeo Giulia vehicles because rear brake discs may fracture, potentially reducing braking performance and increasing crash risk.

    Product
    ALFA ROMEO — ALFA ROMEO GIULIA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V645000·2020-10-19

    Mitsubishi Fuso Trucks Recalled for Brake Booster Vacuum Pump Defect

    Mitsubishi Fuso is recalling 2019-2021 FEC7T, FEC9T, and FECZT trucks because heat from the exhaust manifold may crack the brake booster vacuum pump diaphragm, potentially disabling power brake assist.

    Product
    MITSUBISHI FUSO — MITSUBISHI FUSO FEC7T, FEC9T, FECZT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V631000·2020-10-14

    Mercedes-Benz Recalls 2020 Sprinter Vans Due to Brake Hose Defect

    Daimler Vans USA is recalling 2020 Mercedes-Benz Sprinter vans because damaged brake hoses may leak fluid, increasing crash risk.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ SPRINTER 2500, SPRINTER 1500, SPRINTER 4500, SPRINTER 3500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V617000·2020-10-06

    Vespa GTS 300 and GTV 300 Scooters Recalled for Brake Pipe Defect

    Piaggio is recalling 2020-2021 Vespa GTS 300 and GTV 300 scooters because improperly galvanized brake pipe terminals can reduce braking efficiency and increase crash risk.

    Product
    VESPA — VESPA GTV 300, GTS 300
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V603000·2020-10-01

    GM Recalls 2018 Trucks and SUVs for Brake Assist Defect

    General Motors is recalling 2018 Cadillac, Chevrolet, and GMC vehicles because a vacuum pump issue can reduce power brake assist, increasing stopping distance.

    Product
    CHEVROLET — CHEVROLET, CADILLAC, GMC SILVERADO 1500, ESCALADE, TAHOE, SIERRA 1500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V593000·2020-09-28

    Kenworth T680 Trucks Recalled for Brake System Valve Defect

    PACCAR is recalling 2016-2021 Kenworth T680 trucks because a brake valve defect may increase stopping distance and crash risk.

    Product
    KENWORTH — KENWORTH T680
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V573000·2020-09-23

    Ford Recalls 2020 Mustangs Due to Brake Pedal Bracket Fracture Risk

    Ford is recalling 2020 Mustangs with automatic transmissions because the brake pedal bracket may fracture, potentially affecting braking ability and increasing crash risk.

    Product
    FORD — FORD MUSTANG
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V563000·2020-09-18

    Travel trailer brake system defect increases crash risk during separation

    Forest River is recalling certain 2018-2021 travel trailers because the breakaway safety switch may not engage the trailer brakes during separation from the tow vehicle. This defect can cause loss of vehicle control and increased crash risk.

    Product
    FOREST RIVER — FOREST RIVER WILDWOOD, SALEM, SONOMA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20E070000·2020-09-11

    Oshkosh Recalls Bendix Pressure Switches for Brake System Air Leak Risk

    Oshkosh is recalling Bendix Pressure Switches sold as aftermarket parts because plastic threads may strip, causing air leaks that can reduce braking performance or disable brake lights.

    Product
    SERVICE BRAKES recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V499000·2020-08-24

    Oshkosh Recalls 2020 S-Series Vehicles for Brake Switch Defect

    Oshkosh is recalling 172 2020 S-Series vehicles because a pressure switch defect may cause air leaks, increased braking distance, or brake light failure.

    Product
    OSHKOSH — OSHKOSH S-SERIES
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V476000·2020-08-13

    BMW Recalls Motorcycles Due to Front Brake Caliper Fluid Leaks

    BMW is recalling specific 2019-2020 motorcycles because front brake calipers may leak fluid, potentially reducing brake performance and increasing crash risk.

    Product
    BMW — BMW R 1250 RT, R 1250 GS ADVENTURE, R 1250 GS, S 1000 RR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V454000·2020-08-04

    Indian Recalls 2019 Scout Motorcycles Due to Brake Performance Issues

    Indian Motorcycle is recalling 2019 Scout, Scout Sixty, and Scout Bobber models because trapped air in the brake system may reduce performance and increase crash risk.

    Product
    INDIAN — INDIAN SCOUT BOBBER, SCOUT, SCOUT SIXTY
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·20V435000·2020-07-28

    Daimler Recalls 2021 Thomas Built Buses Saf-T-Liner C2 School Buses

    Daimler Trucks North America is recalling 2021 Saf-T-Liner C2 School Buses because the brake pedal arm may rotate out of position, increasing crash risk.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER C2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·20V390000·2020-07-02

    2017-2021 Freightliner Cascadia brake modulator valve corrosion recall

    Certain 2017-2021 Freightliner Cascadia tractor trailers are recalled due to chemical corrosion in the brake modulator valve, which can slow brake release and cause brakes to pull to one side during automatic braking, increasing crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER CASCADIA
    Category
    Vehicle
    Distribution
    Distributed nationwide