The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

22776–22800 of 40339

  • HighFDA (Devices)·Z-2834-2018·2018-08-29

    Liebel-Flarsheim Direct Digital Imaging System Recalled for Software Display Discrepancy

    Liebel-Flarsheim is recalling 28 Direct Digital Imaging Systems due to a software issue causing significant discrepancies between display and dosimeter readings in pediatric modes.

    Product
    Liebel-Flarsheim Direct Digital Imaging System (DDIS) Liebel-Flarsheim urology systems facilitate radiologic and/or fluoroscopic procedures requiring a beam of diagnostic quality radiation, primarily for urological applications such as functional x-ray diagnostics…
    Category
    Medical Device
    Distribution
    30 states
  • HighFDA (Devices)·Z-2853-2018·2018-08-29

    Philips DigitalDiagnost 4.1 Chest X-Ray Unit Recalled for Footplate Hazard

    Philips is recalling DigitalDiagnost 4.1 Chest X-Ray units because a defective hook allows the footplate to fall, posing a risk of injury to patients or operators.

    Product
    DigitalDiagnost 4.1 Chest / Emergency (Stitching Patient Support) 712029
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2868-2018·2018-08-29

    Philips EasyDiagnost Eleva DRF Footplate Hook Recall

    Philips is recalling EasyDiagnost Eleva DRF units because a defective hook allows the footplate to fall or swing, posing an injury risk to patients and operators.

    Product
    EasyDiagnost Eleva DRF, Release 5 (Stitching Patient Support) 706050
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2859-2018·2018-08-29

    Philips DigitalDiagnost Dual Detector Footplate Recall for Injury Risk

    Philips is recalling DigitalDiagnost Dual Detector units because a defective hook allows the footplate to fall or swing, posing a risk of injury to patients or operators.

    Product
    DigitalDiagnost Dual Detector (Stitching Patient Support) 712022
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2867-2018·2018-08-29

    Philips EasyDiagnost Eleva DRF Footplate Recall for Injury Risk

    Philips is recalling EasyDiagnost Eleva DRF units because a defective hook allows the footplate to fall or swing, posing an injury risk to patients and operators.

    Product
    EasyDiagnost Eleva DRF (Stitching Patient Support) 706032
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2845-2018·2018-08-29

    Philips DigitalDiagnost Footplate Hook Recall for Injury Risk

    Philips is recalling DigitalDiagnost Release 3.1 units because a defective hook allows the footplate to fall or swing, posing an injury risk to operators or patients.

    Product
    DigitalDiagnost Release 3.1 (Stitching Patient Support) 712026
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2841-2018·2018-08-29

    Philips DigitalDiagnost 2.x Upgrades Recalled Due to Footplate Injury Risk

    Philips is recalling two DigitalDiagnost 2.x Upgrades because a defective hook allows the footplate to fall or swing, posing a risk of injury to operators or patients.

    Product
    DigitalDiagnost 2.x Upgrades (Stitching Patient Support) 712082
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2877-2018·2018-08-29

    TriMed Ulnar Osteotomy Compression Plate Recalled for Manufacturing Defect

    TriMed Inc. is recalling 722 Ulnar Osteotomy Compression Plates because instrument holes are located on the wrong side of the plate.

    Product
    Ulnar Osteotomy Compression Plate, Short Model: UOCP-S Product Usage: The UOCP-S is provided non-sterile with the required fixation screws and surgical instrumentation. The TriMed Ulnar Osteotomy Plate is intended for use in osteotomy procedures of the ulna.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2875-2018·2018-08-29

    Zimmer Biomet Recalls Connecting Bolts Due to Material Error

    Zimmer Biomet is recalling 247 connecting bolts made from incorrect material, which may decrease fatigue strength and lead to fracture.

    Product
    Connecting Bolt, Model 14-442093
    Category
    Medical Device
    Distribution
    20 states
  • HighFDA (Devices)·Z-2872-2018·2018-08-29

    GE Healthcare Optima CT540 Systems Recalled for Damaged Cable Hazard

    GE Healthcare is recalling Optima CT540 systems because a damaged cable may expose 120VAC to service engineers working inside the gantry.

    Product
    GE Healthcare Optima CT540. The systems are intended for head, whole body, cardiac and vascular X-ray Computed Tomography applications.Sold under the following product names: BEIJING CT OPTIMA 540, BEIJING OPTIMA, BEIJING OPTIMA 540, BEIJING OPTIMA 540 ASIR, CT BEIJING…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2862-2018·2018-08-29

    Philips DigitalDiagnost Footplate Hook Recall Due to Injury Risk

    Philips is recalling DigitalDiagnost Release 3.1 units because a defective hook allows the footplate to fall or swing, posing a risk of injury to patients or operators.

    Product
    DigitalDiagnost Release 3.1 (Stitching Patient Support) 712026
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2752-2018·2018-08-29

    Handicare C Series Patient Lifts Recalled for Premature Strap Wear

    Handicare USA Inc. is recalling 716 C Series Patient Lifts because straps may wear and break prematurely at maximum weight conditions.

    Product
    Handicare C Series Patient Lift Product Usage: A device used to lift and transport a patient from one place to another.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2856-2018·2018-08-29

    Philips DigitalDiagnost Classic 1.x Upgrades Recalled for Footplate Safety Hazard

    Philips is recalling DigitalDiagnost Classic 1.x Upgrades because the footplate hook may fail to hold the plate securely, posing a risk of injury to patients or operators.

    Product
    DigitalDiagnost Classic 1.x Upgrades (Stitching Patient Support) 712081
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2887-2018·2018-08-29

    CAREstream ProNox Nitrous Oxide Delivery Systems Recalled for High Gas Levels

    CAREstream Medical LLC is recalling 919 ProNox Nitrous Oxide Delivery Systems because two units delivered higher levels of nitrous oxide than specified during routine testing.

    Product
    CAREstream ProNox Nitrous Oxide Delivery System labeled as the following: a. CMI-0100 PNX, Pro-Nox Mixer - Canadian; b. CMI-0100-PNX-HS, Pro-Nox Complete Hospital Roll Stand System - Nitrous Oxide Delivery System; c. CMI-0100-PNX-HS-NO2H, Pro-Nox Hospital System…
    Category
    Medical Device
    Distribution
    47 states
  • HighFDA (Devices)·Z-2855-2018·2018-08-29

    Philips DigitalDiagnost 4.1 High Performance Footplate Recall Issued

    Philips is recalling DigitalDiagnost 4.1 High Performance units because a defective hook allows the footplate to fall or swing, posing an injury risk to patients and operators.

    Product
    DigitalDiagnost 4.1 High Performance (Stitching Patient Support) 712031
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2884-2018·2018-08-29

    Stryker T2 Orthopedic Nails Recalled for Incomplete Sterility Seal

    Stryker GmbH is recalling 38 T2 orthopedic nails due to incomplete Tyvek lid seals that may compromise sterility.

    Product
    Stryker T2 ANKLE ARTHRODESIS NAIL RIGHT 10MMX200MM Item Number: 1819-1020S T2 ANKLE ARTHRODESIS NAIL RIGHT 12MMX200MM 1819-1220S T2 LONG PROXIMAL HUMERAL NAIL LEFT 240mm1832-2824S T2 LONG PROXIMAL HUMERAL NAIL LEFT 280mm 1832-2828S T2 LONG PROXIMAL HUMERAL NAIL RIGHT 260mm…
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2852-2018·2018-08-29

    Philips DigitalDiagnost 4.1 Footplate Hook Recall for Injury Risk

    Philips is recalling DigitalDiagnost 4.1 units because a defective hook allows the footplate to fall, posing a risk of injury to patients or operators.

    Product
    DigitalDiagnost 4.1 (Stitching Patient Support) 712225
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2851-2018·2018-08-29

    Philips DigitalDiagnost 4 Footplate Hook Recall for Injury Risk

    Philips is recalling DigitalDiagnost 4 High Performance units because a defective hook allows the footplate to fall or swing, posing an injury risk to patients and operators.

    Product
    DigitalDiagnost 4 High Performance (Stitching Patient Support) 712027
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2863-2018·2018-08-29

    Philips DigitalDiagnost Single Detector Footplate Hook Recall

    Philips is recalling DigitalDiagnost Single Detector units because a defective hook allows the footplate to fall or swing, posing a risk of injury to patients or operators.

    Product
    DigitalDiagnost Single Detector (Stitching Patient Support) 712020
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2865-2018·2018-08-29

    Philips DigitalDiagnost Dual-Detector Recall for Footplate Safety Hazard

    Philips is recalling DigitalDiagnost Dual-Detector units because a defective hook allows the footplate to fall or swing, posing an injury risk to patients and operators.

    Product
    DigitalDiagnost, Dual-Detector (Stitching Patient Support) 712052
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2885-2018·2018-08-29

    O-Two Equinox Relieve Gas System Recalled for High Nitrous Oxide Levels

    O-Two Medical Technologies is recalling three Equinox Relieve gas systems because they may deliver higher levels of nitrous oxide than specified.

    Product
    O-Two Equinox¿ Relieve N2O/O2 Analgesic Gas Mixing and Delivery System Model#: 01EQ1000
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-2846-2018·2018-08-29

    Philips BuckyDiagnost Ceiling System Recalled for Footplate Safety Hazard

    Philips is recalling BuckyDiagnost Ceiling Systems because the footplate hook may fail to hold the plate securely, posing a risk of injury to patients or operators.

    Product
    BuckyDiagnost Ceiling System (Stitching Patient Support) 704031
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2857-2018·2018-08-29

    Philips DigitalDiagnost Classic Footplate Hook Recall for Injury Risk

    Philips is recalling DigitalDiagnost Classic units because a defective hook allows the footplate to fall or swing, posing an injury risk to patients and operators.

    Product
    DigitalDiagnost Classic, Dual-Detector (Stitching Patient Support) 712052
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2871-2018·2018-08-29

    GE Healthcare Optima CT660 Recall for Damaged Cable Electrical Hazard

    GE Healthcare is recalling Optima CT660 systems because a damaged cable may expose 120VAC to service engineers working inside the gantry.

    Product
    GE Healthcare Optima CT660. Sold under the following product names: BEIJING OPTIMA CT660 PRO GT170, BEIJING OPTIMA CT660 PRO GT200, BEIJING OPTIMA CT660S PRO 32 S, CT GOLDSEAL, CT GOLDSEAL OPTIMA 660, CT GOLDSEAL OPTIMA 660 UT-BUC, CT OPTIMA 660 LNG HN P20, CT OPTIMA…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2866-2018·2018-08-29

    Philips DigitalDiagnost Footplate Hook Recall for Injury Risk

    Philips is recalling DigitalDiagnost Single-Detect units because a defective hook allows the footplate to fall or swing, posing an injury risk to patients and operators.

    Product
    DigitalDiagnost, Single-Detect (Stitching Patient Support) 712062
    Category
    Medical Device
    Distribution
    Distributed nationwide