About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

5501–5525 of 40520

  • HighFDA (Devices)·Z-0738-2025·2025-01-01

    Siemens Blood Analysis System Software Malfunction May Cause Patient Identification Error

    Siemens epoc NXS Host blood analysis systems are recalled due to a software malfunction that can assign incorrect patient names to blood tests, potentially leading to misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413517(MX) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0767-2025·2025-01-01

    Siemens magnesium reagent cartridges recalled for false measurement results

    Siemens is recalling two lots of Magnesium Flex reagent cartridges due to potential falsely low magnesium measurements. The intermittent error may not be detected by standard quality control procedures.

    Product
    Magnesium Flex reagent cartridge, 360 tests, Catalog Number: K3057; Siemens Material Number (SMN): 10445158;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0732-2025·2025-01-01

    Abbott Vascular Inflation Device May Leak During Cardiovascular Procedures

    Abbott Vascular is recalling the 20/30 Priority Pack Accessory Kit w/Copilot inflation device used in cardiovascular procedures because it may leak at connection points, potentially causing air embolism.

    Product
    20/30 Priority Pack Accessory Kit w/Copilot, REF: 1003327, used for cardiovascular procedures.
    Category
    Medical Device
    Distribution
    40 states
  • HighFDA (Devices)·Z-0757-2025·2025-01-01

    Sterile Magill Forceps Recalled Due to Weak Seals and Contamination Risk

    Medline has recalled Sterile Magill Forceps (Item No. 66790) due to weak seals that may compromise sterility. The defect affects approximately 21,440 units distributed nationwide.

    Product
    STERILE MAGILL FORCEP (MAGF9), Medline Item No. 66790
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0741-2025·2025-01-01

    Siemens epoc blood analyzer software assigns incorrect patient names

    Siemens epoc NXS blood analysis system has a software defect that can incorrectly assign patient names to blood test results, potentially causing misdiagnosis or mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413879(IN) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0736-2025·2025-01-01

    Siemens epoc Blood Analysis System Recalled for Patient Identification Software Error

    Siemens is recalling epoc NXS Host blood analysis systems due to a software malfunction that can assign incorrect patient names to test results, potentially leading to misdiagnosis and mistreatment if not verified by the user.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413498(JP) ; Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0742-2025·2025-01-01

    Galaxy System bronchoscope power supply defect may injure lung tissue

    Noah Medical's Galaxy System bronchoscope has defective power supply semiconductors that may fail during procedures, potentially causing pneumothorax or lung tissue injury when the scope is manually removed.

    Product
    Galaxy System (GAL-001). Intended to provide bronchoscopic visualization of and access to patient airways for diagnostic and therapeutic procedures.
    Category
    Medical Device
    Distribution
    15 states
  • HighFDA (Devices)·Z-0727-2025·2025-01-01

    Cardiac troponin test reagent recalled for potential false results

    Beckman Coulter recalls 2.1 million units of Access hsTnI reagent worldwide due to contamination causing falsely elevated troponin results in patient samples.

    Product
    Access hsTnI Reagent, REF B52699, Immunoassay Method, Troponin Subunit. For the quantitative determination of cardiac troponin I (cTnI) levels in human serum and plasma.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0756-2025·2025-01-01

    Medline Surgical Needle Holders Recalled for Sterility Compromise

    Medline is recalling 21,440 surgical needleholders due to weak seals that may compromise sterility and increase risk of contamination and infection during surgical use.

    Product
    ST OR MAYO HEGAR NEEDLEHOLDER 6"(OR2500), Medline Item No. 67870
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0734-2025·2025-01-01

    Blood Analysis System Recalled Due to Patient Name Assignment Software Error

    Siemens is recalling the epoc NXS Host blood analysis system due to a software defect that can incorrectly assign patient names to test results, potentially causing misdiagnosis and mistreatment.

    Product
    epoc NXS Host; Siemens Material Number (SMN): 11413475 (US); Software Version Number: 4.14.9. Intended for use by trained medical professionals as an in vitro diagnostic device for the quantitative testing of samples of heparinized or un-anticoagulated arterial, venous or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0758-2025·2025-01-01

    Medline Reprocessed Bruns Curette Surgical Instruments Recalled for Weak Sterile Seals

    Medline is recalling 21,440 reprocessed Bruns curettes due to weak sterile seals that may fail without user detection. This increases the risk of contamination and infection.

    Product
    ST REPROCESSED BRUNS CURETTE #00 (BC00), Medline Item No. 67600K
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0731-2025·2025-01-01

    Abbott Vascular inflation device may leak during cardiovascular procedures

    Abbott Vascular is recalling 20/30 Priority Pack Accessory Kit inflation devices due to potential leaks that could cause air embolism during cardiovascular procedures.

    Product
    20/30 Priority Pack Accessory Kit/.096 RHV, REF: 1000186, or use during vascular procedures in conjunction with interventional and / or diagnostic devices (e.g., balloon dilatation catheters, atherectomy devices, stent delivery systems, intravascular ultrasound devices).
    Category
    Medical Device
    Distribution
    40 states
  • HighFDA (Devices)·Z-0725-2025·2025-01-01

    Surgical Patties and Strips with Endotoxin Contamination in Medline Convenience Kits

    Medline Industries is recalling surgical patties and strips in specific lots of KIT,SPINE LH Convenience Kits due to higher-than-expected endotoxin levels in raw materials. The contamination may result in out-of-specification endotoxin in finished sterile products.

    Product
    KIT,SPINE LH Convenience kit, SKU DYNJ906448A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0694-2025·2025-01-01

    Panther Fusion Assay Kit Recalled for Possible SARS-CoV-2 False Positives

    Hologic is recalling specific lots of the Panther Fusion SARS-CoV-2/Flu A/B/RSV Assay due to potential false positive SARS-CoV-2 results. Users should verify positive results with an alternative testing method.

    Product
    Panther Fusion SARS-CoV-2/Flu A/B/RSV Assay, REF: PRD-07400
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0744-2025·2025-01-01

    TEMA Elbow System Prostheses Recalled for Mechanical Behavior Concern

    Limacorporate is recalling TEMA Elbow System prostheses due to potential differences in mechanical behavior between implanted devices and surgical revision tools. Approximately 87 devices distributed in Florida and Texas are affected.

    Product
    TEMA Elbow - Axle Small REF 1590.15.010 TEMA Elbow - Axle Large REF 1590.15.020 TEMA Elbow System is a cemented total elbow prosthesis.
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Devices)·Z-0769-2025·2025-01-01

    Hip Reconstruction System Component Mislabeled for Size

    Waldemar Link is recalling 3 units of the LINK MP Reconstruction System Neck Segment due to a labeling error indicating the wrong size (XXL instead of standard), though all other specifications on the labels are correct.

    Product
    LINK MP Reconstruction System Neck Segment (with suture holes, standard, uncemented, L= 35 mm, CCD 126¿, Offset= 31 mm, Ti6Al4V, PoroLink, Taper 12/14. Item Number: 99-0984/32 Intended for revision hip arthroplasty in patients whose bone stock is of poor quality or…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0750-2025·2025-01-01

    BYTE Aligner System Recalled for Virtual-Only Approval Workflow Gaps

    Straight Smile LLC is recalling BYTE Aligner systems due to a virtual-only clinical workflow that may not adequately screen patients with contraindications for aligner use. Approximately 5.3 million devices are affected.

    Product
    BYTE Aligner System REF PRS-0063 BYTE All-Day Aligner System BYTE AT-Night Aligner System A custom-made orthodontic appliance, typically supplied in series intended to be worn in succession and self-changed every few weeks, designed to influence the shape and/or function…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0761-2025·2025-01-01

    EMPOWR 3D Knee Tibial Insert Recalled for Wrong Product in Package

    Encore Medical is recalling 9 units of EMPOWR 3D Knee Tibial Insert (Lot 076T1273A) because packages may contain an acetabular system instead of the intended knee insert, potentially causing surgical delays.

    Product
    EMPOWR 3D Knee Tibial Insert, 6R 10MM, VE, REF: 342-10-706
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0729-2025·2025-01-01

    O&M Halyard Surgical Masks Recalled for Failing Bioburden Testing

    O&M Halyard SOFT TOUCH II Surgical Masks (lot AM4119961) are being recalled for not meeting EN 14683 bioburden testing standards printed on the packaging. No illnesses or injuries have been reported.

    Product
    O&M Halyard SOFT TOUCH II Surgical Mask, Blue-Disposable surgical mask Product Code: 47500
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0657-2025·2024-12-25

    Ambler Surgical Bipolar Pencil recalled for outer tube structural failure

    Kirwan Surgical Products is recalling the Ambler Surgical Bipolar Pencil 25 Gauge Straight (Model PD7226) because the outer stainless-steel tube may break or detach during use. 4,470 units worldwide are affected.

    Product
    Ambler Surgical Bipolar Pencil 25 Gauge Straight. Model/Catalog Number: PD7226. The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissue procedures. For instance, the pencils are designed for cauterization of the retinal area…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0656-2025·2024-12-25

    Surgical Bipolar Pencil Recall: Risk of Tube Breakage During Eye Surgery

    Kirwan Surgical Products is recalling disposable bipolar surgical pencils used in eye surgery because the outer stainless-steel tube may break or detach during use.

    Product
    Accutome/Microsurgical Disposable Bipolar Pencil 5 in. (12.7cm) 25 Gauge Straight. Model/Catalog Number: AB-7004 The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissue procedures. For instance, the pencils are designed for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0668-2025·2024-12-25

    FDA Recalls Draeger Atlan A300XL Anesthesia Workstation for Ventilator Failure

    Draeger Medical recalls the Atlan A300XL anesthesia workstation for potential piston ventilator failure that could occur before use or during anesthesia delivery. Twenty-five units were distributed outside the United States.

    Product
    Brand Name: Atlan Product Name: Atlan A300XL Model/Catalog Number: 8621400 The Atlan is an anesthesia workstation intended for use in anesthetizing adults, pediatrics, and neonates.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0661-2025·2024-12-25

    Medtronic Becker Neurosurgical Drainage Systems Recalled for Cracked and Leaking Stopcocks

    Medtronic Neurosurgery recalls Becker External Drainage and Monitoring Systems due to reports of cracks and leaks in stopcocks. The recalled systems are used to drain cerebrospinal fluid and monitor pressure in neurosurgery patients.

    Product
    Becker External Drainage and Monitoring System: 24146 EDMS 24146 BECKER NO Y-SITE 25120 EDMS II 25120 BECKER W/1-WAY VALVE 26040 KIT 26040 BECKER EDMS II 27609 BECKER 27609 W/NEEDLESLESS INJ. SITE 27670 BECKER 27670 STOP BELOW DC NDL-LS IN 27672 BECKER 27672 ONEWAY VLV…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0658-2025·2024-12-25

    Walcott Bipolar Pencil Surgical Instrument Recalled for Potential Tube Detachment

    Kirwan Surgical Products is recalling Walcott Bipolar Pencil 25 Gauge surgical instruments due to potential breakage or detachment of the stainless-steel tube. The affected pencils are used in eye and soft tissue surgery.

    Product
    Walcott Bipolar Pencil 25 Gauge Straight. Model/Catalog Number: RX14-5011. Product Description: The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissue procedures. For instance, the pencils are designed for cauterization of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0655-2025·2024-12-25

    Kirwan Surgical Bipolar Pencil Recalled Due to Potential Tube Breakage

    Kirwan Surgical Products is recalling its Disposable 25-gauge Bipolar Pencil (Model 14-5011L) because the outer stainless-steel tube may break or detach during use. The defect could create a safety hazard during eye surgery and other soft tissue procedures.

    Product
    Kirwan Surgical Products LLC Disposable 25-gauge bipolar pencil, straight, Long. Model/Catalog Number: 14-5011L The Disposable Microsurgical Bipolar Pencil are designed for use in eye surgery, and other soft tissue procedures. For instance, the pencils are designed for…
    Category
    Medical Device
    Distribution
    Distributed nationwide