Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

4876–4900 of 40520

  • HighFDA (Devices)·Z-1379-2025·2025-03-26

    CO2 Sampling and Airway Adapter Devices May Be Difficult to Disconnect

    Oridion Medical's CO2 sampling and airway adapter devices may be difficult to disconnect from endotracheal tubes, potentially causing treatment delays and serious respiratory complications in neonatal, infant, and pediatric patients.

    Product
    Microstream Instructions for Use and Part Number used with - Product Description, REF: Airway Adapter and CO2 Sampling Line, 01158 - Microstream Luer Adult-Pediatric Airway Adapter, 010989; Omnistream CO2 Sampling Line X25, 010991
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1344-2025·2025-03-26

    Labor and Delivery System Recalled for Sterilization Assurance Issue

    American Contract Systems is recalling 1,836 Labor and Delivery PPS kits due to inability to confirm sterilization requirements were met. The affected units may lose functionality, potentially delaying patient treatment.

    Product
    LABOR & DELIVERY PPS , Model No LLLD64O LLLD64O-01 LLLD64O-02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1402-2025·2025-03-26

    Merge Cardio Software Recalled: Measurement Inconsistency in Patient Reports

    Merge Healthcare recalls Merge Cardio cardiovascular software due to measurement data inconsistency. When users manually edit or remeasure values in certain workflows, derived measurements may not match original measurements in patient reports.

    Product
    Merge Cardio, Model/Catalog Number: Version 12.X, Software Version: 12.1, 12.1.1, 12.2, 12.3, 12.3.1, 12.3.2, 12.3.3, 12.4, 12.4.1, 12.4.2; Merge Cardio is a software medical device that is an integrated multi-modality image cardiovascular information management system.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1407-2025·2025-03-26

    Synapse PACS Software incorrect patient age calculation for infants

    FUJIFILM's Synapse PACS Software versions 7.4.x incorrectly calculates patient age for infants under 3 months, potentially affecting clinical decisions. 104 units recalled in US and internationally.

    Product
    Synapse PACS Software Version 7.4.x; Software Versions: 7.4.000, 7.4.001, 7.4.010, 7.4.100, 7.4.110, 7.4.200.
    Category
    Medical Device
    Distribution
    30 states
  • HighFDA (Devices)·Z-1384-2025·2025-03-26

    Microstream CO2 Sampling Line Disconnection Failure Poses Respiratory Risk

    Microstream CO2 sampling adapters may become difficult or impossible to disconnect from endotracheal tubes, potentially delaying critical procedures and causing respiratory complications.

    Product
    Microstream Instructions for Use and Part Number used with - Product Description, REF: Microstream Advance Intubated Adult-Pediatric, PT00156254 - Microstream Advance Adult-Pediatric Intubated CO2 Filter Line 2m/6.5ft Short-term use: Procedural/Emergency, MVAI…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1395-2025·2025-03-26

    Zebra Thermal Barcode Printer power supply units recalled due to fire hazard

    Remel, Inc. is recalling approximately 41 Zebra Thermal Barcode Printer GX430t power supply units due to a potential fire hazard. The power supplies may overheat, creating a fire risk.

    Product
    Zebra Thermal Barcode Printer GX430t, Model no. YSW 1000 or YSW 2000, may have been sold as an optional accessory for Sensititre Aris HIQ system YV4000-VZ
    Category
    Medical Device
    Distribution
    17 states
  • HighFDA (Devices)·Z-1334-2025·2025-03-26

    Medical Device Sterilization Assurance Recall: MAJOR DIEP Surgical Kits

    American Contract Systems Inc is recalling 17 MAJOR DIEP surgical kits because sterilization assurance requirements cannot be confirmed. This creates a risk of device malfunction and treatment delays.

    Product
    MAJOR DIEP, Model Nos. CCMJ73G-01 CCMJ73H
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1341-2025·2025-03-26

    Birth Delivery Kit Recalled Due to Unconfirmed Sterilization Assurance

    American Contract Systems Inc recalls the Born on Arrival Kit due to inability to confirm sterilization assurance. Unsterilized equipment could delay or prolong newborn treatment.

    Product
    BORN ON ARRIVAL KIT , Model No LLBN11B
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1335-2025·2025-03-26

    Cystoscopy Kit Recalled for Sterilization Assurance Verification Failure

    American Contract Systems Inc is recalling CYSTO PACK cystoscopy kits because the company cannot confirm sterilization assurance requirements were met. Possible loss of functionality could delay or prolong patient treatment.

    Product
    CYSTO PACK , Model N. HKCY31A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1331-2025·2025-03-26

    Laparoscopy Surgical Packs Recalled Due to Unconfirmed Sterilization

    American Contract Systems Inc. is recalling 303 Laparoscopy Packs (Models CALS41F, CALS41F-01, CALS41G) because sterilization assurance requirements could not be confirmed. Unsterilized instruments may cause infection or delayed treatment.

    Product
    LAPAROSCOPY PACK, Model No. CALS41F, CALS41F-01, CALS41G
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1364-2025·2025-03-26

    Surgical Drape Packs Recalled for Potential Sterility Breach in Packaging

    Medline Industries is recalling Proxima Sterile Surgical Drape packs due to a potential breach in the pouch packaging that could lead to loss of sterility. The recall affects 1,490 units distributed nationwide.

    Product
    Proxima Drape labeled as PACK,BASIC,SIRUS,V,5/CS; PACK,BASIC IV,SIRUS,5/CS; PACK,SET UP,NO DRAPE,12/CS; PACK,SET UP,NO DRAPE,12/CS; PACK,SET UP,NO DRAPE,12/CS; PACK,SET UP,NO DRAPE,12/CS; PACK,SET UP,NO DRAPE,12/CS; PACK,UNIVERSAL II,SIRUS,7/CS; PACK,LAPAROTOMY,NO GOWN,10/CS…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1400-2025·2025-03-26

    VERICIS Merge Cardio Medical Device Software Measurement Data Consistency Issue

    VERICIS Merge Cardio cardiovascular imaging software may display measurement values in patient reports that do not match original measurements when measurements are remeasured or manually edited. This affects 66 units distributed in the United States.

    Product
    VERICIS, Merge Cardio, Model/Catalog Number: Version 11.x, Software Version: 11.0.2, 11.0.3, 11.0.4, 11.1, 11.1.1; The VERICIS is an integrated cardiovascular information system classified as a picture archiving and communications system.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1380-2025·2025-03-26

    CO2 Sampling Line Adapter May Be Difficult to Disconnect; Risk of Respiratory Failure

    Microstream CO2 sampling line and airway adapter may be difficult or impossible to disconnect during procedures, potentially causing treatment delays and respiratory complications including hypoxia.

    Product
    Microstream Instructions for Use and Part Number used with - Product Description, REF: OmniVentLine Set, 012808 - OmniVentLine Set Adult-Pediatric CO2 Sampling Line and Airway Adapter, 012495;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1346-2025·2025-03-26

    CYSTO Model SACY80R Recall for Sterilization Assurance Failure

    American Contract Systems Inc is recalling 144 CYSTO Model SACY80R kits due to inability to confirm sterilization requirements were met. Unsterilized devices may lose functionality and delay patient treatment.

    Product
    CYSTO , Model No SACY80R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1404-2025·2025-03-26

    CAPNOCHECK BCI Airway Adapter may break off, causing ventilation failure

    The CAPNOCHECK BCI Airway Adapter (Model BSR) may break when attached to a valve or tube, risking airway circuit failure and loss of ventilation. Approximately 175,994 units were recalled nationwide.

    Product
    CAPNOCHECK BCI Airway Adapter; Model Number BSR; Product Code WW1100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1355-2025·2025-03-26

    Neuro IR Tray recalled over unconfirmed sterilization assurance

    American Contract Systems Inc is recalling Neuro IR Tray (Model WENI56J) due to inability to confirm sterilization assurance. Loss of functionality could delay or prolong treatment.

    Product
    NEURO IR TRAY , Model No WENI56J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1332-2025·2025-03-26

    DR DIULUS Injection Pack Models Recalled for Sterilization Assurance Issues

    American Contract Systems Inc is recalling 1,200 DR DIULUS Injection Pack kits because the manufacturer cannot confirm sterilization assurance requirements were met. This may result in loss of functionality and treatment delays.

    Product
    DR DIULUS INJECTION PACK, Model Nos. CCDU12C CCDU12D CCDU12D-01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1383-2025·2025-03-26

    Microstream CO2 Sampling Line May Not Disconnect From Intubation Tube

    Microstream intubated CO2 sampling lines may be difficult or impossible to disconnect from endotracheal tubes. This could delay necessary procedures and cause unintended extubation, potentially leading to respiratory failure.

    Product
    Microstream Instructions for Use and Part Number used with - Product Description, REF: Microstream Luer Intubated Adult Pediatric, PT00156355 - Microstream Luer Adult-Pediatric Intubated CO2 Sampling Line 2m/6.5ft Short-term use: Procedural/Emergency, MLAI
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1339-2025·2025-03-26

    Open Heart Surgery Kit Sterilization Assurance Cannot Be Confirmed

    American Contract Systems Inc is recalling 90 Open Heart Adult Side A surgical kits due to inability to confirm sterilization requirements were met. Unsterilized devices could lose functionality and delay patient treatment.

    Product
    OPEN HEART ADULT - SIDE A , Model Nos LLOH01I-01 LLOH01I
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1382-2025·2025-03-26

    Microstream Neonatal-Infant CO2 Filter Line May Be Difficult to Disconnect

    Microstream Neonatal-Infant Intubated CO2 Filter Lines may become difficult or impossible to disconnect from endotracheal tubes during clinical procedures, potentially delaying treatment and causing unintended extubation.

    Product
    Microstream Instructions for Use and Part Number used with - Product Description, REF: Microstream Adv. Infant Intubated, PT00134354 - Microstream Advance Neonatal-Infant Intubated CO2 Filter Line 2m/6.5ft Extended Duration, QMVIIH
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1405-2025·2025-03-26

    CAPNOCHECK Airway Adapter May Break Off, Risking Ventilation Loss

    CAPNOCHECK BCI Airway Adapters may break off when a valve or tube is attached, causing airway circuit disconnection and loss of ventilation. This could result in inability to ventilate, hypoxia, cardiopulmonary collapse, or death.

    Product
    CAPNOCHECK BCI Airway Adapter; Model Number BSR; Product Code WW8214
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1358-2025·2025-03-26

    Vascular Pack Sterilization Assurance Requirements Cannot Be Confirmed

    American Contract Systems cannot confirm Major Vascular Pack surgical kits were properly sterilized. Sterilization assurance failure could result in loss of functionality and delayed patient treatment.

    Product
    MAJOR VASCULAR PACK , Model No UTMV78X-01 UTMV78Y UTMV78Y-01 UTMV78X-01 UTMV78Y-02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1406-2025·2025-03-26

    Cranial Surgery Procedure Kit Recalled Over Sterility Assurance Failure

    American Contract Systems Inc is recalling 91 CRANI PACK cranial procedure kits because a critical component cannot be confirmed to meet sterility requirements, making them unsuitable for surgical use.

    Product
    CRANI PACK, Model/Catalog Number WECR41D, medical procedure kit.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1372-2025·2025-03-26

    Modular Stem Orthopedic Implant Recalled Due to Incorrect Product Identifier

    37 units of a modular stem orthopedic implant (Product Code 880-601/11) have been recalled due to an incorrect GTIN product identifier on the carton label, which belongs to a different product. No illnesses or injuries have been reported.

    Product
    Modular Stem cylindrical, Tilastan¿, press-fit cementless, L= 80 mm, DIA = 11 mm, Product Code: 880-601/11
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1386-2025·2025-03-26

    Access 2 Immunoassay Analyzer motor alignment issue may delay results

    Beckman Coulter is recalling Access 2 Immunoassay Analyzers due to sample motor misalignment that may delay patient test result reporting. The recall affects 873 units distributed worldwide.

    Product
    Access 2 Immunoassay Analyzer, Catalog Number 81600N
    Category
    Medical Device
    Distribution
    Distributed nationwide