The Recall Desk

Category

Medical device recalls

FDA recalls of medical devices including diagnostics, implants, and consumer health hardware.

About medical device recalls

Medical device recalls are the FDA's highest-volume stream. They cover implantable devices like pacemakers and joint replacements, hospital diagnostics and lab analyzers, surgical instruments, software-as-a-medical-device, and consumer-facing hardware like CPAP machines, blood-pressure cuffs, and glucose monitors. The volume comes from the wide range of products in scope and from the FDA's broad definition of 'corrective action' — software updates, IFU revisions, and labeling corrections all show up as recalls.

For Class I device recalls, the device's defect creates a reasonable risk of serious injury or death — these are the urgent ones. Class II covers issues that may cause temporary or medically reversible harm, often around accuracy or calibration. Class III is for products that don't comply with FDA rules but pose no real safety risk; in practice many software-update letters are Class III.

If you depend on a recalled device for ongoing care, don't disconnect or stop using it before talking to the prescribing clinician — interrupting therapy for a CPAP or a continuous glucose monitor can be more dangerous than the recall it's responding to. Almost every device recall offers a remedy that doesn't require you to surrender the device first.

27776–27800 of 40397

  • ModerateFDA (Devices)·Z-1189-2017·2017-02-22

    BD Vacutainer Blood Collection Tubes Recalled for Excess Anticoagulant

    Becton Dickinson is recalling specific lots of BD Vacutainer blood collection tubes because they contain approximately twice the expected amount of buffered sodium citrate additive.

    Product
    BD Vacutainer Buffered Sodium Citrate: (9NC) Blood Collection Tube (4.5 ml x 13 x 75 mm) Catalog Number: 369714 Product Usage: The BD Vacutainer Safety Coagulation tube is an evacuated blood collection tube that provides means of collecting, transporting and processing…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1200-2017·2017-02-22

    BioMerieux Recalls VIDAS 3 Software Version 1.1.4 Due to Anomalies

    BioMerieux SA is recalling 1,161 units of VIDAS 3 software version 1.1.4 in the U.S. because anomalies identified during the development of version 1.2 were found to be present in the current field version.

    Product
    VIDAS 3 software v. 1.1.4
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1190-2017·2017-02-22

    Greatbatch Recalls T5766 Offset Reamer Handles Due to Drive Chain Seizure

    Greatbatch Medical is recalling 1,441 T5766 Offset Reamer Handles because the drive chain U-joints may seize during hip surgery, rendering the device non-functional.

    Product
    Offset Reamer Handle, T5766 Product Usage: The reamer handles are re-usable surgical instruments used in arthroplasty surgery of the hip joints, where either total joint replacement or resurfacing surgery is performed using a reamer cutting instrument. The reamer handles are…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1221-2017·2017-02-22

    Atrium Medical Recalls 8 Fr Thoracic Catheters Due to Labeling Error

    Atrium Medical Corporation is recalling 8 Fr Straight Thoracic Catheters because the label depicts six eyelets instead of the correct two.

    Product
    Atrium PVC 8 Fr Straight Thoracic Catheter Code Number: 8008
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1198-2017·2017-02-22

    Arthrex Shoulder Suspension Tower Recalled for Loose Screw Risk

    Allen Medical Systems is recalling 112 Arthrex Shoulder Suspension Towers because fastening screws may come loose and enter the sterile field.

    Product
    Arthrex Shoulder Suspension Tower; Catalog Number: AR-1650-01 Product Usage: The Arthrex Lateral Decubitus Shoulder Positioner is intended to allow for the controlled manipulation of the arm and shoulder joint during arthroscopic surgical procedures.
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1196-2017·2017-02-22

    Argon Medical Devices Recalls Harvest Needles Due to Sterility Concerns

    Argon Medical Devices is recalling 15 boxes of Harvest Needles because a potential defect in the blister packaging may compromise the sterility of the product.

    Product
    HARVEST NEEDLE 15GA X 2 Intended for the purpose of harvesting bone and/or bone marrow specimens
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1216-2017·2017-02-22

    Siemens Enzyme 2 Calibrator Recalled for Positive Result Shifts

    Siemens Healthcare Diagnostics is recalling Enzyme 2 Calibrators because they may cause patient and QC results to shift up to 10% when used with the Dimension Vista System.

    Product
    The Enzyme 2 Calibrator is an in vitro diagnostic product for the calibration of Alanine Aminotransferase (ALTI and ALTI) and Aspartate Aminotransferase (AST) methods on the Dimension Vista System. For prescription use only.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1183-2017·2017-02-15

    Invacare Recalls Bariatric Beds Due to Fire Hazard

    Invacare is recalling Bariatric Beds (BARPKG-IVC 1633) because a quality issue with the junction box may cause sparks and result in a fire.

    Product
    Bariatric Bed - BARPKG-IVC 1633
    Category
    Medical Device
    Distribution
    37 states
  • SevereFDA (Devices)·Z-1185-2017·2017-02-15

    Invacare Bariatric Bed Junction Box Recalled for Fire Risk

    Invacare is recalling 161 bariatric bed junction boxes due to a quality issue that may cause sparks and result in a fire.

    Product
    Junction Box - 1104343 and 1193560
    Category
    Medical Device
    Distribution
    37 states
  • SevereFDA (Devices)·Z-1182-2017·2017-02-15

    Invacare Bariatric Bed Recall Due to Fire Hazard

    Invacare is recalling 411 bariatric beds because the junction box may emit sparks and cause a fire.

    Product
    Bariatric Bed - BAR600IVC
    Category
    Medical Device
    Distribution
    37 states
  • SevereFDA (Devices)·Z-1184-2017·2017-02-15

    Invacare Recalls Bariatric Bed Foot Sections Due to Fire Risk

    Invacare Corporation is recalling 292 bariatric bed foot sections because a quality issue with the junction box may cause sparks and result in a fire.

    Product
    Foot Section - BAR5490IVC
    Category
    Medical Device
    Distribution
    37 states
  • SevereFDA (Devices)·Z-1138-2017·2017-02-15

    Carestream DRX-Revolution Mobile X-Ray System Recalled for Brake Failure

    Carestream Health is recalling DRX-Revolution Mobile X-Ray Systems because a complaint alleged the unit could not be stopped when applying the brake, resulting in a crash into an elevator.

    Product
    Carestream DRX-Revolution Mobile X-Ray System, Model DRXR-1, Catalog No. 1019397 (all other countries), Catalog No. 1060177 (China only) -- Carestream Health, Inc. 150 Verona Street, Rochester, NY 14608
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1137-2017·2017-02-15

    AngioDynamics Recalls Celerity ECG Cable Accessory Packs Due to Soldering Defect

    AngioDynamics is recalling Celerity ECG Cable Accessory Packs because the ECG clip cable may not be soldered correctly, potentially preventing the device from conducting ECG signals.

    Product
    Celerity ECG Cable Accessory Pack, STERILE, Rx ONLY - distributed under the following labels: (a) angiodynamics UPN/Product No. H787471431, REF/Catalog No. 47-143 -- Legal Manufacturer: AngioDynamics, Inc. 10 Glens Falls Technical Park, Glens Falls, NY 12801; and (b) medCOMP…
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-0927-2017·2017-02-15

    Bayer Recalls Medrad Intego PET Infusion System Pumps

    Bayer is recalling Medrad Intego PET Infusion System pumps because the administration sets may produce particulates in radiopharmaceutical vials.

    Product
    MEDRAD Intego PET Infusion System - Pump Intended to deliver accurate doses of Fluoredeoxyglucose or F-Sodium Fluoride and commonly used flushing solutions to patients during molecular imaging (nuclear medicine) diagnostic procedures. It is also intended to provide effective…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1178-2017·2017-02-15

    Boston Scientific Recalls EMBLEM S-ICD Programmer Model 3200

    Boston Scientific is recalling 4,500 EMBLEM S-ICD Programmer Model 3200 units due to a potential risk of radio frequency interference causing unintended commands during in-clinic sessions.

    Product
    Boston Scientific, EMBLEM S-ICD Programmer Model 3200 Programmer.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1144-2017·2017-02-15

    Physio-Control Recalls LIFEPAK 15 Defibrillators with Erroneous CO2 Readings

    Physio-Control is recalling LIFEPAK 15 Monitor/Defibrillators with End-Tidal CO2 options because the CO2 reading may intermittently display an incorrect value of XXX.

    Product
    LIFEPAK 15 Monitor/Defibrillator with End-Tidal CO2 option. Intended for use by trained medical personnel in out-of-doors and indoor emergency care settings within the environmental conditions specified in the Operating Instructions.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1149-2017·2017-02-15

    Stryker Leibinger Recalls Surgical Drainage Accessories Due to Sterility Labeling Error

    Stryker Leibinger is recalling QUINTUBE Monitor Packs and SPG Bulb Drain Systems because non-sterile products were incorrectly labeled as sterile.

    Product
    QUINTUBE Monitor Pack (5 tubes/pk, 24 pk/case) (Non-Sterile) SPG Bulb Drain System, 4mm Flat w/Center Holes (Sterile) Accessories to TLS Surgical Drainage System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1180-2017·2017-02-15

    Merge RadSuite software recalled due to incorrect pixel value data

    Merge Healthcare is recalling RadSuite software version V8.30.7.8 because incorrect pixel values may lead to patient injury or delayed diagnosis.

    Product
    Merge RadSuite software. The firm name on the label is Merge Healthcare, Hartland, WI.
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-1142-2017·2017-02-15

    Merge Healthcare Recalls Eye Station Imaging Devices Due to Capture Failures

    Merge Healthcare is recalling 182 Eye Station capture stations because they may fail to capture eye images as intended, posing a risk to patient health.

    Product
    Merge Eye Station. f/k/a: DFC-1024 & DFC-512 Digital Imaging System, WinStation, and WinStation Retinal Imager distributed by Ophthalmic Imaging Systems (OIS). Model number 136 T1700 Capture Stations & 46 T5810 Capture Stations.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1148-2017·2017-02-15

    AtriCure Recalls AtriClip LAA Exclusion System Due to Jaw Breakage

    AtriCure is recalling 464 AtriClip LAA Exclusion System devices because a complaint was received regarding the PRO2 jaw breaking prior to surgery.

    Product
    AtriClip" LAA Exclusion System with preloaded Gillinov-Cosgrove" Clip - A single PRO2 device is packaged in a conventional thermoformed polyethylene terephthalate glycol (PETG) tray with a Tyvek¿ lid. A single-walled non-corrugated box completes the single unit package. Six (6)…
    Category
    Medical Device
    Distribution
    31 states
  • HighFDA (Devices)·Z-1176-2017·2017-02-15

    Merge PACS Software Recalled for Potential Incorrect Patient Image Display

    Merge Healthcare is recalling Merge PACS software version 7.0.1 because it may display incorrect patient images, potentially delaying diagnosis or treatment.

    Product
    Merge PACS software. The firm name on the label is Merge Healthcare, Hartland, WI.
    Category
    Medical Device
    Distribution
    17 states
  • HighFDA (Devices)·Z-1177-2017·2017-02-15

    Teleflex Recalls Sheridan Cuffed Tracheal Tubes Due to Labeling Inconsistency

    Teleflex Medical is recalling Sheridan cuffed tracheal tubes because some units are labeled with incorrect sizes, potentially leading to improper airway management.

    Product
    Sheridan/CF, Cuffed Tracheal Tube, Catalog # 5-10114 and Sheridan/HVT Cuffed Tracheal Tube, Catalog # 5-10315 A tracheal tube is inserted into a patients mouth or nose for airway management
    Category
    Medical Device
    Distribution
    38 states
  • ModerateFDA (Devices)·Z-1143-2017·2017-02-15

    Physio-Control Recalls LIFEPAK 12 Defibrillators with Erratic CO2 Readings

    Physio-Control is recalling LIFEPAK 12 Defibrillators because the End-Tidal CO2 reading may intermittently display an invalid value of XXX during operation.

    Product
    LIFEPAK 12 Defibrillator/Monitor with End-Tidal CO2 option. The device is used in various areas of the hospital such as critical areas (emergency departments, critical care, operating room, etc.) and general duty floors (e.g. medical/surgical). The device is also used…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1150-2017·2017-02-15

    Stryker Leibinger Recalls Non-Sterile Medpor Implant Sizer Sets Due to Labeling Error

    Stryker Leibinger is recalling specific non-sterile Medpor implant sizer sets because they were incorrectly labeled as sterile. The recall covers 619 units distributed in the US and several international countries.

    Product
    9805 Orbital Volume Sizer Set with Tray (Non-sterile) 9951 Design M Malar Sizer Set (Silicone, Non-Sterile) 9952 Extended Contoured, Malar Sizer Set (Silicone, Non-Sterile) 85000 Petite Nasal Dorsum Sizer Set (Silicone, Non-Sterile) Accessories to Medpor Implants
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1140-2017·2017-02-15

    Siemens Dimension Ammonia Reagent Cartridges Recalled for Calibration Issues

    Siemens Healthcare Diagnostics is recalling specific lots of Dimension Ammonia Flex reagent cartridges because they may not meet the 60-day calibration interval claim, potentially leading to abnormal assay results.

    Product
    Dimension¿ Ammonia Flex¿ reagent cartridge / AMM Dimension: The AMM method is an in vitro diagnostic test for the quantitative measurement of ammonia in human plasma on the Dimension clinical chemistry system. Ammonia measurements are used in the diagnosis and treatment of…
    Category
    Medical Device
    Distribution
    Distributed nationwide

Looking for a different category? Browse all recalls.