The Recall Desk

Agency

U.S. Food and Drug Administration

The FDA regulates food, drugs, biologics, medical devices, and tobacco. We aggregate Class I, II, and III enforcement actions across its three recall streams.

Visit the official FDA site →

About FDA recalls

The FDA is the single biggest source of US product recalls by volume. Its enforcement workload splits into three streams — Foods (everything from infant formula to leafy greens to nutritional supplements), Drugs (prescription medicines, over-the-counter products, and active pharmaceutical ingredients), and Medical Devices (everything from implants to home blood-pressure monitors). The Recall Desk ingests all three from the openFDA enforcement endpoint every six hours.

FDA classifies every recall as Class I, II, or III. Class I means there is a reasonable probability that using the product will cause serious health consequences or death — these are the recalls you should treat as urgent. Class II means the product may cause temporary or medically reversible harm. Class III means the product is unlikely to cause adverse health consequences but still violates FDA rules. We map these classifications into our 1–5 severity score using the rubric on the methodology page.

Medical-device recalls are the highest-volume stream by far — software-update letters, calibration corrections, and IFU updates all show up in enforcement reports alongside genuine hazard recalls. We try to surface the severe ones first, but when in doubt, click through to the FDA notice itself for the clinical detail.

60151–60175 of 88419

  • HighFDA (Food)·F-1995-2016·2016-09-07

    Tippin's Mini Key Lime Pie Bases Recalled for Potential Peanut Residue

    Tippin's Gourmet Pies is recalling 32 cases of Mini Key Lime Pie Bases because they were manufactured with an ingredient that may contain low levels of peanut residue.

    Product
    Tippins Mini Key Lime Base packaged in ?. UPC code is 680816000106. Packaged in 30 pie bases per case. Shipped frozen. Net wt. 11oz each.
    Category
    Food
    Distribution
    7 states
  • HighFDA (Devices)·Z-2669-2016·2016-09-07

    Philips Recalls Allura Xper Systems Due to Power Supply Failure Risk

    Philips is recalling 1,536 Allura Xper medical imaging systems because certain low-voltage DC power supplies have an increased failure rate.

    Product
    Allura Xper with release R8.2: Allura Xper FD10, 722026; Allura Xper FD10/10, 722027; Allura Xper FD20, 722028; Allura Xper FD20/10 biplane, 722029; Allura Xper FD10 OR Table, 722033; Allura Xper FD10/10 OR Table, 722034; Allura Xper FD20 OR Table, 722035; Allure Xper…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2705-2016·2016-09-07

    Medical Vision Ab Recalls Double Pump RF Patient Cassettes

    Medical Vision Ab is recalling 3,295 Double Pump RF Patient Cassettes because sterile package breakage may compromise device sterility.

    Product
    Double Pump RF Patient Cassette; Product Number: 72204055. Intended to provide fluid distension and irrigation and fluid suction during diagnostic and operative arthroscopic procedures.
    Category
    Medical Device
    Distribution
    22 states
  • HighFDA (Food)·F-1991-2016·2016-09-07

    Tippin's Key Lime Pie Recalled for Potential Peanut Residue

    Tippin's Gourmet Pies is recalling 8-inch Key Lime Pies because an ingredient may contain low levels of peanut residue.

    Product
    Tippins 8" Key Lime Pie packaged in aluminum pie plates with plastic covers. The responsible firm listed on the label is TGP, LLC Kansas City, KS 66106. UPC code is 680816050057. Packaged in 8 pies per case. Shipped frozen.
    Category
    Food
    Distribution
    7 states
  • ModerateFDA (Drugs)·D-1474-2016·2016-09-07

    Clinique Moisturizer Recalled for Low Sunscreen Ingredient Levels

    Clinique International is recalling Moisture Surge Tinted Moisturizer SPF 15 because two active sunscreen ingredients are below required levels.

    Product
    CLINIQUE moisture surge tinted moisturizer broad spectrum SPF 15, 1 FL. OZ.LIQ./30 ml bottle within a carton, Clinique Labs., Dist. New York, N.Y., 10022; New York, London W1K 3BQ; Paris, UPC No. 20714-47477-5, Shade 02 (VF-N)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2706-2016·2016-09-07

    Terumo Cardiovascular Procedure Kits Recalled for Incorrect Tubing Coating Labeling

    Terumo is recalling 2,207 cardiovascular procedure kits because they are labeled as containing coated tubing but actually contain non-coated tubing.

    Product
    Terumo Custom Cardiovascular System Cardiovascular Procedure Kits labeled containing Coated Tubing as follows: This product is intended for use only in the extracorporeal circuit for the cardiopulmonary bypass procedures for which the user designed it. This product is a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-2005-2016·2016-09-07

    Natrium Products Recalls Sodium Bicarbonate Due to Lubricating Oil Contamination

    Natrium Products Inc. is recalling 1,677 bags of sodium bicarbonate that may contain varying amounts of food-grade lubricating oil.

    Product
    SODIUM BICARBONATE, CAS # 144-55-8, USP/FCC GRADE 1, NET WEIGHT 50 lbs./22.68 kg --- Natrium Products, Inc. 58 Pendleton Street, Cortland, NY 13045
    Category
    Food
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-2685-2016·2016-09-07

    Merge Healthcare Recalls RadSuite Software Due to Image Display Errors

    Merge Healthcare is recalling RadSuite software versions 8.30.6 through 8.30.6.3 because interventional radiology images are not displaying correctly.

    Product
    RadSuite software. The firm name on the label is Merge Healthcare, Hartland, WI. RadSuite provides a means to distribute, display, and store diagnostic-quality medical images in electronic format.
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Drugs)·D-1475-2016·2016-09-07

    Clinique Moisturizer Recalled for Low Sunscreen Ingredient Levels

    Clinique International is recalling Moisture Surge Tinted Moisturizer SPF 15 because two active sunscreen ingredients are below required levels.

    Product
    CLINIQUE moisture surge tinted moisturizer broad spectrum SPF 15, 1 FL. OZ.LIQ./30 ml bottle within a carton, Clinique Labs., Dist. New York, N.Y., 10022; New York, London W1K 3BQ; Paris, UPC No. 20714-47478-2, Shade 03 (MF-N)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2690-2016·2016-09-07

    Fujifilm Digital Mammography System Recalled for Biopsy Workflow Error

    Fujifilm is recalling two Aspire HD Digital Mammography Systems because an aborted stereo biopsy may cause an error that prevents the system from operating properly.

    Product
    FUJIFILM Digital Mammography System Aspire HD (FDR MS-1000) with Biopsy Positioner (FDR-1000BPY) The Fujifilm Digital Mammography System, Aspire HD (FDR MS-1000), generates full-field digital mammography images that can, as other full-field digital mammography systems, be…
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Drugs)·D-1477-2016·2016-09-07

    Clinique Moisturizer Recalled for Low Sunscreen Ingredient Levels

    Clinique International is recalling Moisture Surge Tinted Moisturizer SPF 15 because two active sunscreen ingredients are below required levels.

    Product
    CLINIQUE moisture surge tinted moisturizer broad spectrum SPF 15, 1 FL. OZ.LIQ./30 ml bottle within a carton, Clinique Labs., Dist. New York, N.Y., 10022; New York, London W1K 3BQ; Paris, UPC No. 20714-48240-4, Shade 05 (D-G)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-1478-2016·2016-09-07

    Clinique Moisturizer Recalled for Low Sunscreen Ingredient Levels

    Clinique International is recalling Moisture Surge Tinted Moisturizer SPF 15 because two active sunscreen ingredients are below required levels.

    Product
    CLINIQUE moisture surge tinted moisturizer broad spectrum SPF 15, 1 FL. OZ.LIQ./30 ml bottle within a carton, Clinique Labs., Dist. New York, N.Y., 10022; New York, London W1K 3BQ; Paris, UPC No. 20714-48241-1, Shade 06 (D-G)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2711-2016·2016-09-07

    Nidek Specular Microscope CEM-530 Software Recall for Unapproved Feature

    Nidek Inc is recalling 29 Specular Microscope CEM-530 units because software versions 1.08 and 1.09 include an unapproved analysis feature.

    Product
    SPECULAR MICROSCOPE CEM-530; Software version 1.08 and 1.09. Opthalmic: The NIDEK Specular Microscope CEM-530 provides non-contact, high magnification image capture of endothelium enabling observation of the size and shape of cells. Information such as the number of…
    Category
    Medical Device
    Distribution
    18 states
  • ModerateFDA (Devices)·Z-2686-2016·2016-09-07

    Merge Healthcare Recalls iConnect Enterprise Archive Due to Image Display Issues

    Merge Healthcare is recalling iConnect Enterprise Archive software because interventional radiology images are not displaying correctly in RadSuite.

    Product
    iConnect Enterprise Archive. The firm name on the label is Merge Healthcare, Hartland, WI. iConnect Enterprise Archive is intended for use as a vendor neutral archive for storage and communications of medical images and data.
    Category
    Medical Device
    Distribution
    2 states
  • LowFDA (Devices)·Z-2707-2016·2016-09-07

    Limacorporate SMR Allen Wrench Recalled for Dimensional Non-Conformance

    Limacorporate S.p.A is recalling 76 SMR allen wrenches (5 mm) because they are dimensionally non-conforming and may not function with some T-handles.

    Product
    SMR allen wrench 5 mm, product code 9013.50.210
    Category
    Medical Device
    Distribution
    0 states
  • LowFDA (Drugs)·D-1473-2016·2016-09-07

    Clinique Moisturizer Recalled for Low Sunscreen Ingredient Levels

    Clinique International is recalling Moisture Surge Tinted Moisturizer SPF 15 because two active sunscreen ingredients are below required levels.

    Product
    CLINIQUE moisture surge tinted moisturizer broad spectrum SPF 15, 1 FL. OZ.LIQ./30 ml bottle within a carton, Clinique Labs., Dist. New York, N.Y., 10022; New York, London W1K 3BQ; Paris, UPC No. 20714-47476-8, Shade 01 (VF-N)
    Category
    Drug
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-1476-2016·2016-09-07

    Clinique Moisturizer Recalled for Low Sunscreen Ingredient Levels

    Clinique International is recalling Moisture Surge Tinted Moisturizer SPF 15 because two active sunscreen ingredients are below required levels.

    Product
    CLINIQUE moisture surge tinted moisturizer broad spectrum SPF 15, 1 FL. OZ.LIQ./30 ml bottle within a carton, Clinique Labs., Dist. New York, N.Y., 10022; New York, London W1K 3BQ; Paris, UPC No. 20714-47479-9, Shade 04 (M-N)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1978-2016·2016-08-31

    SM Fish Corp. Recalls Herring Due to Listeria Contamination Risk

    SM Fish Corp. is recalling Ossie's Taam Shabbos Herring because the manufacturing plant tested positive for Listeria monocytogenes. The product was distributed in New York and New Jersey.

    Product
    OSSIE'S TAAM SHABBOS HERRING, NET WT. 7 OZ., UPC 739885109057; -- Far Rockaway, NY 11691 --- The product is packed in a plastic deli tub.
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Devices)·Z-2358-2016·2016-08-31

    Alere INRatio2 PT/INR Home Monitoring System Recalled for Inaccurate INR Results

    Alere San Diego is voluntarily recalling INRatio2 PT/INR Home Monitoring Systems because they may display inaccurate INR results compared to central laboratory tests.

    Product
    Alere INRatio2 PT/INR Home Monitoring System Model Number: 0200432, 0200433 Product Usage: Alere INRatio 2 PT/INR Home Monitoring System: The Alere INRatio 2 PT/INR Home Monitoring System, consisting of the INRatio 2 Home Monitor and INRatio PT/INR test strip, is used for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1989-2016·2016-08-31

    SM Fish Corp. Recalls Ossie's Pickled Lox Due to Listeria Risk

    SM Fish Corp. is recalling Ossie's Pickled Lox because the manufacturing plant tested positive for Listeria monocytogenes. The product was distributed in New York and New Jersey.

    Product
    OSSIE'S PICKLED LOX, NET WT. 8 OZ., UPC 739885104137; -- Far Rockaway, NY 11691 --- The product is packed in a plastic deli tub.
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Food)·F-1980-2016·2016-08-31

    SM Fish Corp. Recalls Ossie's Wasabi Herring Due to Listeria Risk

    SM Fish Corp. is recalling Ossie's Wasabi Herring because the manufacturing plant tested positive for Listeria monocytogenes. The product was distributed in New York and New Jersey.

    Product
    OSSIE'S WASABI HERRING, NET WT. 7 OZ., UPC 739885109088; -- Far Rockaway, NY 11691 --- The product is packed in a plastic deli tub.
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Devices)·Z-2614-2016·2016-08-31

    Cook Inc. Recalls Slip-Cath Beacon Tip Catheters Due to Tip Fracture

    Cook Inc. is recalling Slip-Cath Beacon Tip Catheters because polymer degradation can cause the tip to fracture or separate, potentially leading to device fragments in the body.

    Product
    Slip-Cath Beacon Tip Catheter Catheter, Intravascular, Diagnostic The catheters are intended for use in angiographic procedures by physicians trained and experienced in angiographic techniques.
    Category
    Medical Device
    Distribution
    Distributed nationwide