  • SevereFDA (Devices)·Z-2691-2026·2026-07-22

    ABIOMED Impella CP Heart Pump Set Introducer Sheath Leakage Risk

    ABIOMED Impella CP heart pump sets contain introducers that may leak from under the sheath cap and along hub score lines. These manufacturing defects are not visible during use.

    Product
    ABIOMED Impella CP Set, Pump Set Code 0048-0044; containing Introducer Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2684-2026·2026-07-22

    ABIOMED Introducer Kit 23 Fr heart pump accessory leakage risk

    Abiomed is recalling ABIOMED Introducer Kit 23 Fr due to potential sheath leakage from manufacturing defects. The leakage risk is not visually detectable and affects all current batches worldwide.

    Product
    ABIOMED Introducer Kit 23 Fr, 11 cm, Pump Set Code 1000441, containing Kit, 23Fr Introducer, 11cm, Sterile, Introducer Product Code 2000342. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2689-2026·2026-07-22

    ABIOMED Impella CP Heart Pump Set Introducer Sheath Leakage Risk

    ABIOMED is recalling Impella CP heart pump sets worldwide due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines in 14Fr and 23Fr introducers. The manufacturing defect is not visually detectable.

    Product
    ABIOMED Impella CP Set, Pump Set Code 0048-0014; containing Introducer Product Code 0052-3046. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2690-2026·2026-07-22

    Abiomed Impella CP Smart Assist Set Heart Pump Introducer Sheath Leakage

    Abiomed is recalling the Impella CP Smart Assist Set due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines in 14Fr and 23Fr introducers. These manufacturing issues are not visually detectable.

    Product
    ABIOMED Impella CP Smart Assist Set, JP, Pump Set Code 0048-0024-JP; containing Introducer Product Code 0052-3025-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2708-2026·2026-07-22

    Arterial Line Kit with Lidocaine HCL Injection Fails Sterility Testing

    Argon Medical Devices is recalling an Arterial Line Kit containing Lidocaine HCL Injection USP because the kits do not meet sterility release criteria, creating a risk of infection from non-sterile medical injection.

    Product
    Arterial Line Kit 20ga x 6, REF: 400115A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2704-2026·2026-07-22

    Transvenous Pacing Electrode Tray with Bipolar Balloon Pacing Electrode Recalled

    Argon Medical Devices is recalling Transvenous Pacing Electrode Trays with Bipolar Balloon Pacing Electrode 5F because kits containing Lidocaine HCL Injection USP did not meet sterility release criteria.

    Product
    Transvenous Pacing Electrode Tray w/ Bipolar Balloon Pacing Electrode 5F, REF: 008416A, 008566A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2720-2026·2026-07-22

    Olympus Ellik Evacuator Recalled for Inadequate Sterilization Risk

    Olympus Corporation of the Americas is recalling the Olympus Ellik Evacuator (Model 194) worldwide because certain sterilization parameters in the instructions may not render the device adequately sterile.

    Product
    Olympus Ellik Evacuator Includes Glass Body, Male Connecting Tubing & Latex Bulb. Model Number: 194.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2724-2026·2026-07-22

    ICU Medical Plum Solo Precision IV Pump May Deliver Excess Medication

    ICU Medical is recalling the Plum Solo Precision IV Pump (v1.0.3) because in specific scenarios, the pump may fail to decrease the displayed volume and could deliver up to twice the programmed medication amount.

    Product
    ICU Medical Plum Solo Precision IV Pump, v1.0.3, Item Number 400010401; infusion pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2685-2026·2026-07-22

    Abiomed Impella CP Introducer Kit heart pump accessory recall

    Abiomed is recalling Impella CP Introducer Kits worldwide due to potential leakage from the introducer sheath that cannot be visually detected by users. The manufacturing defect affects 1,540 units across multiple countries.

    Product
    ABIOMED Impella CP Introducer Kit 14 Fr, 13 cm, Pump Set Code 0052-0038, containing Kit, 14Fr Introducer, 13cm, Long Taper, Introducer Product Code 0052-3052. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2687-2026·2026-07-22

    ABIOMED Impella 5.5 Heart Pump Introducer Sheath Leakage Risk Recall

    Abiomed is recalling the Impella 5.5 Smart Assist Set heart pump due to potential leakage from introducer sheaths. The defect is not visually detectable and affects all affected pump sets worldwide.

    Product
    ABIOMED Impella 5.5 Smart Assist Set, JP, Pump Set Codes 1000211, 1000212; containing Introducer Product Code 0052-3006-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2705-2026·2026-07-22

    One-Piece Introducer Tray kits recalled for sterility failure

    Argon Medical Devices is recalling One-Piece Introducer Tray kits containing Lidocaine HCL Injection because they do not meet sterility release criteria. The kits were distributed nationwide and internationally.

    Product
    One-Piece Introducer Tray, REF: 497455, 497434 cardiovascular
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2723-2026·2026-07-22

    ICU Medical Plum Duo Infusion Pump Software Defect Affecting Drug Delivery

    ICU Medical is recalling Plum Duo Infusion Pump v1.2.3 units due to a software defect that may cause the pump to deliver up to twice the programmed volume without decrementing the display, risking patient overdose.

    Product
    ICU Medical Plum Duo Infusion Pump, v1.2.3: 1) Item Number 400020401 and 2) Item Number 400020403; infusion pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2692-2026·2026-07-22

    ABIOMED Insertion Kit heart pump accessories introducer sheath leakage

    Abiomed is recalling ABIOMED Insertion Kits due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines. The manufacturing defect is not visually detectable by users.

    Product
    ABIOMED Insertion Kit, Pkgd, JP, Pump Set Code 0052-0011-JP; containing Introducer Product Code 0052-3006-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0690-2026·2026-07-22

    ChloraPrep One-Step Applicators Recalled for Potential Packaging Seal Defects

    CareFusion 213, LLC is recalling ChloraPrep One-Step (chlorhexidine gluconate and isopropyl alcohol) applicators nationwide because affected units may have open or incomplete seals on the packaging, which could compromise sterility assurance.

    Product
    CHLORAPREP ONE-STEP — CHLORAPREP ONE-STEP (CHLORHEXIDINE GLUCONATE AND ISOPROPYL ALCOHOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2681-2026·2026-07-22

    ABIOMED Impella RP Flex heart pump introducer sheath leakage risk

    Abiomed is recalling the Impella RP Flex heart pump due to potential introducer sheath leakage from the sheath cap and hub score lines. The manufacturing defect is not visually detectable.

    Product
    ABIOMED Impella RP Flex with SmartAssist Set, Pump Set Code 1000323, containing Kit, 23Fr Introducer, 11cm, Sterile, 23 Fr, 11 cm, Product Code 2000342. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2739-2026·2026-07-22

    Medtronic Bio-Medicus Adult Cannula Kit Recalled for Foreign Material

    Medtronic is recalling its Bio-Medicus Adult Cannula Kit (Product Number 96530-115) used in cardiopulmonary bypass procedures due to the discovery of loose foreign material containing trace levels of blood in two units.

    Product
    Medtronic Bio-Medicus Adult Cannula Kit, Product Number/CFN 96530-115; Cardiopulmonary bypass vascular cannula
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2688-2026·2026-07-22

    Abiomed Impella 5.5 SmartAssist S2 heart pump introducer sheath leakage risk

    Abiomed is recalling Impella 5.5 SmartAssist S2 heart pump sets worldwide due to a potential for introducer sheath leakage from under the sheath cap and along hub score lines that may not be visible to users.

    Product
    ABIOMED Impella 5.5 SmartAssist S2 Set, JP, Pump Set Codes 1000459, 1000460; containing Introducer Product Code 0052-3006-JP. heart pump and accessories
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2709-2026·2026-07-22

    Bone Marrow Tray kits recalled due to sterility failure

    Argon Medical Devices is recalling Bone Marrow Tray kits containing Lidocaine HCL Injection because they do not meet sterility release criteria.

    Product
    Bone Marrow Tray, REF: CB0033TL; CB0355TLA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2719-2026·2026-07-22

    Olympus Toomey Evacuator 50cc with Adaptor sterilization recall

    Olympus is recalling the Toomey Evacuator 50cc with Adaptor (Model 188A) because some sterilization parameters in the instructions may not reliably render the devices sterile.

    Product
    Olympus Toomey Evacuator 50cc with Adaptor. Model Number: 188A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2721-2026·2026-07-22

    Olympus Glass Body for 194 Ellik Evacuator Model 190A Sterilization Recall

    Olympus Corporation is recalling the Glass Body for 194 Ellik Evacuator (Model 190A) because certain sterilization parameters in the instructions may not consistently render the devices adequately sterile.

    Product
    Olympus Glass Body for 194 Ellik Evacuator. Model Number: 190A.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2727-2026·2026-07-22

    GE Optima XR200/220/240amx Radiographic System Column Safety Mechanism

    GE Medical Systems is recalling certain Optima XR200/220/240amx mobile radiographic systems after column replacements because functional testing of the safety pawl may not have been performed, which could allow the X-ray arm to drop and injure patients.

    Product
    Optima XR220amx, Mobile Digital-Ready Radiographic System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26V473000·2026-07-22

    2024–2026 Volkswagen Atlas and Atlas Cross Sport Rearview Camera Software

    Volkswagen is recalling 2024–2026 Atlas and Atlas Cross Sport vehicles due to a low-voltage electrical event that may cause the rearview camera display to fail, reducing rear visibility.

    Product
    VOLKSWAGEN — VOLKSWAGEN ATLAS, ATLAS CROSS SPORT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2718-2026·2026-07-22

    Olympus Toomey Evacuator 30cc medical device sterilization parameters recalled

    Olympus Corporation recalled the Toomey Evacuator 30cc with Adaptor (Model 188) because certain sterilization parameters in the instructions may not consistently render the devices adequately sterile.

    Product
    Olympus Toomey Evacuator 30cc with Adaptor. Model Number: 188.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2741-2026·2026-07-22

    Vasoview Hemopro 2 Endoscopic Vessel Harvesting System Recall

    Maquet Cardiovascular is recalling Vasoview Hemopro 2 devices from Lot 3000547797 due to exposure to out-of-specification sterilization during gamma sterilization. The affected devices may not be properly sterilized.

    Product
    The Vasoview Hemopro 2 Endoscopic Vessel Harvesting System (Model VH-4000; UDI 00607567700406) is a sterile, single-use Class II device that was cleared for marketing by FDA under 510(k) number K101274.
    Category
    Medical Device
    Distribution