  • HighFDA (Devices)·Z-3278-2024·2024-10-02

    FDA Recalls Esophageal Stent Systems Due to Delivery Catheter Tip Detachment Risk

    Boston Scientific recalled 364 esophageal stent systems due to potential delivery catheter tip detachment during placement procedures. No injuries have been reported. Affected patients and providers should contact the manufacturer.

    Product
    WALLFLEX ESOPHAGEAL FC 23/28MMX10CM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophageal
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3249-2024·2024-10-02

    IntelliVue Patient Monitors recalled for electrical grounding defect

    Philips is recalling approximately 545 IntelliVue Patient Monitor units with a broken ground bolt that may cause loss of electrical grounding, potentially affecting the device's electromagnetic immunity and emission.

    Product
    IntelliVue Patient Monitor MX400 (Model Number 866060), MX430 (Model Number 866061), MX450 (Model Number 866062), MX500 (Model Number 866064), and MX550 (Model Number 866066)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0663-2024·2024-10-02

    Pyridoxine Injection Solution Recalled Due to Lack of Sterility Assurance

    Empower Pharmacy is recalling a pyridoxine (B6) injection solution because sterility assurance could not be confirmed. The recalled product is lot 609763 with a beyond-use date of 04/18/2025.

    Product
    Pyridoxine HCL (B6) Injection Solution, 100mg/mL, 30 mL Sterile Multiple-Dose Vial, For IM or IV use only, RX Only, Compounded by: Empower Pharmacy 5980 W Sam Houston Pkwy N Ste 300, Houston, TX 77041 NDC 72627-2424-1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3209-2024·2024-10-02

    Ultrasonic Cleaner Solution Recalled for Bacterial Contamination and Infection Risk

    Ultrasonic cleaner solutions contaminated with pathogenic bacteria may cause serious infections if used in medical or dental procedures, and may leak or become bloated. Patients and healthcare workers handling the products are at risk.

    Product
    Good Vibrations Ultrasonic Cleaner Solution, JorVet J0382G Ultrasonic Instrument Cleaning Solution, SpecClean Ultrasonic Cleaner Solution, Models: GVUS128-1, GVUS128-1EA, GVUS550-1, GVUS24-1, GVUS24-1EA, JGVUS128-1, VGVUSNP128-1, VGVUSNP128-1EA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3226-2024·2024-10-02

    Medical Pacemaker Pack Recalled Due to Sterilization Assurance Failure

    American Contract Systems is recalling the PACEMAKER PACK (Lot 2405112) due to an inoperable chart recorder that prevented confirmation of sterilization requirements. Affected units were distributed in MO, MN, MA, OH, and NE.

    Product
    PACEMAKER PACK, SLCV01J; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3290-2024·2024-10-02

    Esophageal stent systems recalled due to delivery catheter defect

    Boston Scientific has recalled AGILE and WallFlex esophageal stent systems due to potential delivery catheter tip detachment. This defect could occur during stent deployment and affect proper stent placement.

    Product
    AGILE ESO OTW PC 23MM X 15.0CM IN 18.5 F-Agile Esophageal Partially Covered (PC) and Fully Covered (FC) OTW Stent System is intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concu
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3213-2024·2024-10-02

    Cervical disc implant recalled due to foreign contamination during assembly

    Centinel Spine is recalling the Prodisc C SK cervical disc implant due to blue discoloration identified as foreign contamination on the inlay during assembly. The contamination was not fully evaluated in manufacturing validations.

    Product
    prodisc C SK, Total cervical disc replacement, Model/Catalog Number: PDSM5
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3237-2024·2024-10-02

    Medical Convenience Kit Recalled for Failed Sterilization Assurance Validation

    American Contract Systems, Inc. is recalling the Hand Pack AKHD97C medical convenience kit because an inoperable chart recorder caused humidity readings to fall outside specifications, preventing confirmation of sterilization assurance.

    Product
    Hand Pack, AKHD97C; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3286-2024·2024-10-02

    WallFlex and Agile esophageal stent systems recalled for delivery catheter tip detachment

    Boston Scientific is recalling WallFlex and Agile esophageal stent systems due to potential for delivery catheter tip detachment during insertion.

    Product
    WALLFLEX PC ESOPH STENT 23/28MM X 155MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3283-2024·2024-10-02

    Wallflex and Agile Esophageal Stent Systems Recalled for Potential Catheter Tip Detachment

    Boston Scientific is recalling WallFlex and Agile Esophageal Stent Systems due to the potential for delivery catheter tip detachment. The recall affects 39 units distributed worldwide.

    Product
    WALLFLEX PC ESOPH STENT 18/23MM X 153MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3298-2024·2024-10-02

    Origio Sperm Wash Medium Recalled for Low Sodium Pyruvate Concentration

    CooperSurgical is recalling Origio Sperm Wash Medium due to low sodium pyruvate concentration. The deficiency could compromise gamete development in assisted reproductive procedures.

    Product
    Origio Sperm Wash Medium Pack of Five 60ml bottles - Intended for washing of spermatozoa. Part Number: 84055060D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3206-2024·2024-10-02

    BARD MAGNUM Biopsy Needles Recalled Due to Packaging Damage Risk

    Bard Peripheral Vascular is recalling BARD MAGNUM Disposable Core Tissue Biopsy Needles due to possible packaging damage from manufacturing that may compromise sterility.

    Product
    BARD MAGNUM Disposable Core Tissue Biopsy Needle REF: MN1410 MN 1420 MN1610 MN1616 MN1820 MN2010 The Magnum Biopsy System (instrument and needles) is intended for use in obtaining biopsies from soft tissues such as liver, kidney, prostate, breast, spleen, lymph nodes and
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3284-2024·2024-10-02

    Esophageal Stent Systems Recalled Due to Catheter Detachment Risk

    Boston Scientific is recalling Wallflex and Agile esophageal stent systems worldwide due to the potential for delivery catheter tip detachment during placement. The recall affects 133 units distributed globally.

    Product
    WALLFLEX PC ESOPH STENT 23/28MM X 105MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3192-2024·2024-10-02

    Biopsy instrument packaging holes compromise sterile barrier integrity

    Argon Medical Devices recalls BioPince Ultra and Tru-Core II biopsy instruments due to holes in packaging trays compromising the sterile barrier, which may allow microorganism introduction and infection risk.

    Product
    BioPince Ultra Full Core Biopsy Instrument: REF: REF: 360-1080-01, 360-1080-02, 360-1080-03, 360-1580-01, 360-1580-02, 360-1580-03, 360-2080-01, 360-2080-02, 360-2080-03, 370-1080-01, 370-1080-02, 370-1080-03, 370-1580-01, 370-1580-02, 370-1580-03; Tru-Core II Biopsy Instrument,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3244-2024·2024-10-02

    Pacemaker COPM11B Medical Kits Recalled for Sterilization Verification Issue

    American Contract Systems is recalling 3 units of the COPM11B pacemaker medical kits due to inability to confirm sterilization requirements were met. An inoperable chart recorder caused humidity readings to exceed specifications during manufacturing.

    Product
    Pacemaker, COPM11B; Medical convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3197-2024·2024-10-02

    MRI Device Ingenia Ambition S Screws May Loosen and Block Tabletop

    Assembly screws in Philips Ingenia Ambition S MRI systems may loosen and protrude, potentially blocking the patient tabletop and delaying diagnosis. Philips is recalling 64 affected units worldwide.

    Product
    Ingenia Ambition S - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782108 2) 781359 3) 782133
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3247-2024·2024-10-02

    BD Phoenix diagnostic systems may misidentify E. coli in clinical samples

    The BD Phoenix 100 system may misidentify Escherichia coli in clinical samples, potentially leading to misdiagnosis and inappropriate patient treatment. Becton Dickinson is recalling 764 units distributed worldwide.

    Product
    BD Phoenix 100-Intended for the rapid identification (ID) and antimicrobial susceptibility testing (AST) of clinically significant bacteria. The BD Phoenix System provides rapid results for most aerobic and facultative anaerobic Grampositive bacteria. Catalog Number: 448100
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3275-2024·2024-10-02

    Boston Scientific Esophageal Stents Recalled for Catheter Tip Detachment Risk

    Boston Scientific is recalling WallFlex and Agile Esophageal Stent Systems due to potential delivery catheter tip detachment. The recall affects 231 units distributed worldwide.

    Product
    WALLFLEX ESOPHAGEAL FC 18/23-25MMX10CM- Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent e
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3262-2024·2024-10-02

    Airvo 3 Respiratory Device Recalled for Software Issue Affecting Oxygen Delivery

    Fisher & Paykel's Airvo 3 respiratory device has a software defect that may cause it to deliver only room air instead of oxygen during certain alarm conditions, potentially causing oxygen desaturation and hypoxia in patients.

    Product
    PT301US Airvo 3 Respiratory Support Device with software version 1.2.0 and/or 1.5.1 The Airvo 3 is intended to provide high flow warmed and humidified respiratory gases for administration to spontaneously breathing infant, child, adolescent and adult patients in hospitals and
    Category
    Medical Device
    Distribution
    29 states
  • HighFDA (Devices)·Z-3266-2024·2024-10-02

    WallFlex and Agile Esophageal Stent Systems Recalled for Catheter Tip Detachment

    Boston Scientific recalls WallFlex and Agile Esophageal Stent Systems due to potential delivery catheter tip detachment. The affected stents treat esophageal strictures and may cause procedural complications if detachment occurs.

    Product
    WALLFLEX FC ESO STENT RMV 18X123MM-Wallflex Esophageal Partially Covered (PC) and Fully Covered (FC) Stent System Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esopha
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3203-2024·2024-10-02

    MRI Diagnostic Device Screws May Loosen, Block Tabletop

    Philips SmartPath to dStream 1.5T MRI devices may have loose assembly screws that could block the diagnostic tabletop and delay imaging. 32 units distributed worldwide.

    Product
    SmartPath to dStream for 1.5T - For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782112; 2) 781260
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3204-2024·2024-10-02

    MRI Diagnostic Device Loose Screws May Block Patient Tabletop

    Philips SmartPath dStream MRI devices have loose screws in the RF carrier assembly that may interfere with the moving tabletop, potentially delaying diagnosis. Affected units should be inspected and repaired immediately.

    Product
    SmartPath to dStream for XR and 3.0T- For use as a diagnostic device to obtain cross-sectional images, spectroscopic images and/or spectra of the internal structure of the head, body or extremities, in any orientation. (REF) Numbers: 1) 782113; 2) 781270; 3) 782129
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3248-2024·2024-10-02

    Hologic Recalls Selenia Dimensions and 3Dimensions Breast Imaging Software

    Hologic is recalling Selenia Dimensions and 3Dimensions software due to a defect that may cause blurry images and potential misdiagnosis.

    Product
    Selenia Dimensions/ 3Dimensions-Digital breast tomosynthesis Software Version Dimensions 1.12.0 and 3Dimensions 2.3.0 system software as follows Model/Catalog Number: 1. ASY-16824 FMI UPGRADE KIT, DIMENSIONS 1.12.0.3 SYSTEM SOFTWARE UPGRADE FOR 1.11.1 SYSTEMS 2. ASY-16825 FMI
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3277-2024·2024-10-02

    Boston Scientific Esophageal Stent Systems Recalled for Catheter Detachment Risk

    Boston Scientific is recalling WallFlex and Agile esophageal stent systems due to potential delivery catheter tip detachment. The recall affects 79 units distributed worldwide.

    Product
    WALLFLEX ESOPHAGEAL FC 18/23-25MMX15CM- Agile Esophageal Partially Covered and Fully Covered OTW Stent System is intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-3282-2024·2024-10-02

    Boston Scientific recalls WallFlex and Agile esophageal stents for delivery catheter detachment

    Boston Scientific has recalled 308 units of WallFlex and Agile esophageal stent systems due to the potential for delivery catheter tip detachment during stent placement. The affected devices are distributed worldwide.

    Product
    WALLFLEX PC ESOPH STENT 18/23MM X 123MM- Wallflex Esophageal Partially Covered and Fully Covered Stent System is Intended for maintaining esophageal luminal patency in esophageal strictures caused by intrinsic and/or extrinsic malignant tumors, and occlusion of concurrent esophag
    Category
    Medical Device
    Distribution
    Distributed nationwide