The Recall Desk

State

Rhode Island product recalls

72,913 recalls have nationwide distribution and so reach Rhode Island. 3,043 additional recalls listed Rhode Island specifically in their distribution scope.

What the numbers show

Total
3,043
Critical
221
Severe
570
Most recent
2026-09-09

Of the 3,043 recalls naming Rhode Island we have scored against our rubric, 221 (7%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 570 (19%) are Severe.

These figures cover only the 3,043 recalls whose distribution notice names Rhode Island specifically. The 72,913 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

2201–2225 of 75956

  • ModerateFDA (Devices)·Z-1918-2026·2026-04-29

    Rover Mobile X-ray System may malfunction and become inoperable

    Micro-X Ltd. is recalling certain Rover Mobile X-ray Systems (models MXU-RV35 and MXU-RV71) because the X-ray generator may malfunction, rendering the device inoperable.

    Product
    Rover Mobile X-ray System Model/Catalog Number: MXU-RV35 and MXU-RV71
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1830-2026·2026-04-29

    Medline Namic Control Syringes recalled due to rescinded FDA clearance

    Medline Industries is recalling Medline Namic Control Syringes (Model DYNJSYR10CWRB) because the FDA has rescinded their 510(k) regulatory clearance. The recall affects 24,170 units distributed nationwide.

    Product
    Medline Namic Syringes: 1) SYR CNTRL 10ML RING W/ROT NB, Model Number: DYNJSYR10CWRB;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0493-2026·2026-04-29

    Omega-3-Acid Ethyl Esters capsules recalled for failed capsule specifications

    The Harvard Drug Group LLC is recalling Omega-3-Acid Ethyl Esters capsules (1 gram, 50-count cartons) due to failed capsule specifications discovered during routine stability testing.

    Product
    OMEGA-3-ACID ETHYL ESTERS — OMEGA-3-ACID ETHYL ESTERS (OMEGA-3-ACID ETHYL ESTERS)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1895-2026·2026-04-29

    LeadCare Ultra Blood Lead Test Kit Recalled for False Positive Results

    Magellan Diagnostics is recalling the LeadCare Ultra Blood Lead Test Kit (Catalog Number 70-8098) because use with certain third-party micro-collection devices may produce unexpectedly elevated and false positive results, potentially causing delayed diagnosis and unnecessary additional testing.

    Product
    LeadCare Ultra Blood Lead Test Kit; Catalog Number: 70-8098; The LeadCare Ultra kit is provided with the following materials: " Sensors (8 containers of 24 each; 192 tests) " Treatment Reagent Tubes (8 containers of 24 each; 192 tests) " Calibration Button (1 @) " Lead Co
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1911-2026·2026-04-29

    Arrow Radial Artery Catheterization Kit recalled for incorrect adhesive

    Arrow International is recalling Arrow Radial Artery Catheterization Kits due to incorrect manufacturing of the liquid adhesive by a supplier. The recall affects 675 units distributed nationwide.

    Product
    ARROW RADIAL ARTERY CATHETERIZATION KIT REF ASK-04220-UCL1 UDI code: (01)10801902159127(17)270331(11)251203(10)33F25J0352 REF ASK-04020-EUH2 UDI code: (01)10801902213379(17)270731(11)251218(10)33F25J0869 REF ASK-04020-FMC UDI code: (01)10801902212099(17)270731(11)25121
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1893-2026·2026-04-29

    LeadCare II Blood Lead Test Kit Recall for Inaccurate Results

    Magellan Diagnostics is recalling LeadCare II Blood Lead Test Kits because certain third-party micro-collection devices may produce falsely elevated lead results, potentially causing unnecessary testing and delayed results.

    Product
    (1)(2) LeadCare¿ II Blood Lead Test Kit, (3)LeadCare¿ II 5X Blood Lead Test Kit, (4)LeadCare¿ II 9X Blood Lead Test Kit ; Catalog Number(s): (1) 70-6762, (2) 70-6762RUO, (3) 70-8404 (Box containing 5 Test Kits), (4) 70-9000 (Box containing 9 test kits); The LeadCare II kit is p
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1849-2026·2026-04-29

    Medline Medical Device Kits Recall for Loss of 510(k) Clearance

    Medline Industries is recalling certain surgical and medical kits because their 510(k) regulatory clearances for Control Syringes, Guidewires, and/or High-Pressure Tubing have been rescinded. About 2,609 units were distributed nationwide.

    Product
    Medline Kits: 1) BWNBORO CRANIOTOMY PACK-LF, Model Number: DYNJ32841F; 2) CRANIOTOMY PACK-LF, Model Number: DYNJ46069D 3) CAMPUS EXTREMITY PK, Model Number: DYNJ51935A 4) FOOT -XRAY BOWL MEDCUP SPECCUP, Model Number: DYNJ68902A 5) RADIOLOGY SPINE PACK, Model Number: DYNJ806
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1902-2026·2026-04-29

    OER-ELITE Endoscope Reprocessor Connecting Tubes Lock Lever Failure Risk

    Olympus is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2114) because the Version 2 reprocessor connecting tube lock levers may fail prematurely, potentially affecting equipment operation and patient safety during endoscope reprocessing.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2114.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1910-2026·2026-04-29

    Arrow Echogenic Introducer Needle REF ASK-04001-BWK2 Medical Device Recall

    Arrow International is recalling 85 units of the Arrow Echogenic Introducer Needle due to incorrect manufacturing of the liquid adhesive used in the device.

    Product
    Arrow Echogenic Introducer Needle REF ASK-04001-BWK2 UDI code: (01)10801902220315(17)261231(11)251210(10)33F25J0347 This device is intended for injection or aspiration of fluids. The needle protection device covers the needle after use to help prevent needle sticks.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1888-2026·2026-04-29

    Medline Convenience Kits with Polycarbonate Syringes recalled for unapproved design changes

    Medline Industries is recalling Convenience Kits containing 10mL Polycarbonate Colored Syringes due to unapproved design changes made outside of FDA 510(k) clearance.

    Product
    Medline Convenience Kits containing select SKUs of 10mL Polycarbonate Colored Syringes ARTHROSCOPY PACK DYNJ45173D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1850-2026·2026-04-29

    Medline Arthroscopy Pack regulatory clearance rescinded

    The FDA has rescinded regulatory clearances for certain Control Syringes, Guidewires, and High-Pressure Tubing included in Medline's Arthroscopy Pack (Model DYNJ82440). Affected units should not be used.

    Product
    Medline Kits: 1) ARTHROSCOPY PACK, Model Number: DYNJ82440
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1882-2026·2026-04-29

    Medline Polycarbonate Colored Syringes Kits Recalled for Unapproved Design Changes

    Medline Industries is recalling Convenience Kits containing 10mL Polycarbonate Colored Syringes due to unapproved design changes made outside of FDA clearance. The recall affects 270,311 units distributed nationwide and internationally.

    Product
    Medline Convenience Kits containing select SKUs of 10mL Polycarbonate Colored Syringes FACE/RHINOPLASTY PACK DYNJ80343C PLASTIC HEAD-NECK PACK DYNJ86639
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1839-2026·2026-04-29

    Medline ENT and Vascular Kits with Rescinded Regulatory Clearances

    Medline Industries is recalling three ENT and vascular kits (513 units nationwide) because their regulatory clearances for certain components—Control Syringes, Guidewires, and/or High-Pressure Tubing—have been rescinded.

    Product
    Medline Kits: 1) ENT PACK, Model Number: DYNJ59030B; 2) ENT, Model Number: DYNJ908586C; 3) LH 3 PORT W/O WASTEBAG, Model Number: VASC1081C
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0486-2026·2026-04-29

    Furosemide tablets recalled for presence of N-nitroso impurity

    Leading Pharma, LLC is recalling Furosemide 80 mg tablets due to the presence of N-nitroso-Furosemide (NNF) above the recommended intake limit, caused by manufacturing deviations.

    Product
    FUROSEMIDE — FUROSEMIDE (FUROSEMIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1841-2026·2026-04-29

    Medline Breast Pack Kit regulatory clearance rescinded by FDA

    The FDA has rescinded the regulatory clearance for Medline's Breast Pack Kit (Model DYNJ66777D) because certain Control Syringes, Guidewires, and High-Pressure Tubing components no longer meet regulatory standards.

    Product
    Medline Kits: 1) BREAST PACK, Model Number: DYNJ66777D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1846-2026·2026-04-29

    Medline GYN Laparoscopy Pack regulatory clearance rescinded

    Medline Industries has recalled the GYN Laparoscopy Pack (Model DYNJ41257F, Lot 25GBL423) because its regulatory clearances for certain components—including Control Syringes, Guidewires, and High-Pressure Tubing—have been rescinded.

    Product
    Medline Kits: 1) GYN LAPAROSCOPY PACK, Model Number: DYNJ41257F
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1881-2026·2026-04-29

    Medline Convenience Kits with Polycarbonate Syringes Unapproved Design Changes

    Medline Industries is recalling select Convenience Kits containing 10mL polycarbonate colored syringes due to unapproved design changes made outside of FDA 510(k) clearance.

    Product
    Medline Convenience Kits containing select SKUs of 10mL Polycarbonate Colored Syringes BARIATRIC DYNJ905153M, DYNJ905153N GENERAL LAPAROSCOPY PACK DYNJ81602 LAPAROSCOPY DYNJ905157K, DYNJ905157L LAPAROTOMY PACK DYNJ46675G MAJOR LITHOTOMY PACK DYNJ81607 MAJ
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1889-2026·2026-04-29

    Medline Convenience Kits with Polycarbonate Syringes Recalled

    Medline Industries is recalling Medline Convenience Kits containing 10mL polycarbonate colored syringes due to unapproved design changes made outside of FDA clearance.

    Product
    Medline Convenience Kits containing select SKUs of 10mL Polycarbonate Colored Syringes E P DRAPE PACK-LF DYNJ0373061J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1887-2026·2026-04-29

    Medline Convenience Kits with 10mL Syringes recalled for unapproved design changes

    Medline Industries is recalling Convenience Kits containing 10mL Polycarbonate Colored Syringes due to unapproved design changes made outside of FDA 510(k) clearance. The recall affects approximately 270,311 units distributed nationwide and internationally.

    Product
    Medline Convenience Kits containing select SKUs of 10mL Polycarbonate Colored Syringes EXTREMITY PACK DYNJ34846C HAND PACK DYNJ83218A, DYNJ85396 LAMINECTOMY DYNJ905156R MAJOR EXTREMITY DYNJ905159L, DYNJ905159M MAJOR EXTREMITY PACK DYNJ69926A PODIATRY PACK D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1840-2026·2026-04-29

    Medline General Laparoscopy Kit regulatory clearance rescinded

    The FDA has rescinded the 510(k) regulatory clearances for certain Control Syringes, Guidewires, and High-Pressure Tubing components in Medline's General Laparoscopy Kit (Model CDS930027Y). Affected units should not be used.

    Product
    Medline Kits: 1) GENERAL LAPAROSCOPY, Model Number: CDS930027Y
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1909-2026·2026-04-29

    OER-ELITE Endoscope Reprocessor Connecting Tubes Lock Levers Failure Risk

    Olympus Corporation is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2330) because the Version 2 reprocessor connecting tube lock levers may fail prematurely.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2330.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1908-2026·2026-04-29

    Olympus OER-ELITE Endoscope Reprocessor Connecting Tubes Recall

    Olympus is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2138) due to potential premature failure of the Version 2 reprocessor connecting tube lock levers. The defect could affect proper tube attachment during endoscope reprocessing.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2138.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1925-2026·2026-04-29

    Flamingo Funnel Medium surgical device recall due to sterilization incompatibility

    SurgiSmoke Solutions is recalling certain lots of Flamingo Funnel Medium (Model SQ20012-02) because a non-gamma sterilization compatible drape was used during manufacturing, which could affect device safety.

    Product
    Flamingo Funnel Medium, Model Number SQ20012-02
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Drugs)·D-0490-2026·2026-04-29

    Monsel's Solution ferric subsulfate vials recalled for incorrect expiration date printing

    Premier Dental Products is recalling Monsel's Solution (ferric subsulfate) 8 mL vials because the expiration date on the vial itself is printed with an extra digit (2709114 instead of 270914). The carton expiration date is correct.

    Product
    MONSELS SOLUTION — MONSELS SOLUTION (FERRIC SUBSULFATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·26V268000·2026-04-28

    Ford Ranger and Bronco front seat pivot bolts may dislodge

    Ford is recalling certain 2024-2026 Ranger and Bronco vehicles because the front seat frame height-adjust pivot bolt may be loose or dislodged. 179,698 vehicles are affected.

    Product
    FORD — FORD BRONCO, RANGER
    Category
    Vehicle
    Distribution