The Recall Desk

State

Oklahoma product recalls

73,741 recalls have nationwide distribution and so reach Oklahoma. 5,822 additional recalls listed Oklahoma specifically in their distribution scope.

What the numbers show

Total
5,822
Critical
1,040
Severe
1,493
Most recent
2026-10-28

Of the 5,822 recalls naming Oklahoma we have scored against our rubric, 1,040 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,493 (26%) are Severe.

These figures cover only the 5,822 recalls whose distribution notice names Oklahoma specifically. The 73,741 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

37051–37075 of 79563

  • HighNHTSA·19V276000·2019-04-09

    AEV TraumaHawk Ambulances Recalled for Reversed Backup Camera Image

    Halcore Group is recalling 2016-2019 AEV TraumaHawk ambulances because backup camera displays may revert to factory settings, causing the image to reverse and increasing crash risk.

    Product
    AEV — AEV TRAUMAHAWK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V280000·2019-04-09

    Pierce Frontline Vehicles Recalled for Brake Light Wiring Defect

    Pierce is recalling 2018-2019 Frontline C-35X, C-25, C-45X-3, and Encore Rescue vehicles because brake lights may illuminate without the pedal being pressed.

    Product
    FRONTLINE — FRONTLINE C-25, C-35X, ENCORE RESCUE, C-45X-3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·19102·2019-04-09

    Marpac Recalls GO Travel Sleep Sound Machines Due to Burn Hazard

    Marpac is recalling GO travel sleep sound machines because the internal battery can leak and cause an electrical short, posing a burn hazard.

    Product
    GO travel sleep sound machines
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V279000·2019-04-08

    Load Trail Recalls 2018-2019 Dump Trailers Due to Bolt Failure Risk

    Load Trail is recalling 2018-2019 dump trailers because bolts on the hydraulic cylinder can break under heavy loads, causing the dump box to lower rapidly.

    Product
    LOAD TRAIL — LOAD TRAIL TANDEM AXLE DUMP, TRIPLE AXLE DUMP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V278000·2019-04-08

    Ford Recalls F-Series Trucks Due to Block Heater Fire Risk

    Ford is recalling 2015-2019 F-150 and 2017-2019 Super Duty trucks because a damaged block heater cable could cause a fire.

    Product
    FORD — FORD F-250 SD, F-350 SD, F-150, F-550 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V274000·2019-04-05

    Nova Bus Recalls 2011-2019 LFS City Buses for Fire Risk

    Nova Bus is recalling 2011-2019 LFS city buses because an engine door fan electrical connector may overheat and cause a fire.

    Product
    NOVA BUS — NOVA BUS LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·042-2019·2019-04-05

    J&J Snack Foods Recalls Stuffed Sandwiches Due to Plastic Contamination

    J&J Snack Foods Handhelds Corp. is recalling Bremer hot stuffed sandwiches due to possible semi-transparent plastic contamination. No illnesses have been reported.

    Product
    J&J Snack Foods Handhelds Corp. — J&J Snack Foods Handhelds Corp. Recalls Stuffed Sandwich Products due to Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·19V275000·2019-04-05

    Kenworth T680 and T880 Recalled for Parking Brake Signal Delay

    PACCAR is recalling 2018-2020 Kenworth T680 and T880 trucks because a parking brake signal delay in cold weather may cause unexpected vehicle movement.

    Product
    KENWORTH — KENWORTH T680, T880
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V273000·2019-04-04

    BMW Recalls 2006 Models Due to PCV Valve Fire Risk

    BMW is recalling 2006 3, 5, and Z4 series vehicles because a heater in the PCV valve may short circuit, increasing the risk of a fire.

    Product
    BMW — BMW Z4, 530XI, 525I, 325XI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·041-2019·2019-04-04

    Blount Fine Foods Recalls Chicken Soup for Undeclared Milk Allergen

    Blount Fine Foods is recalling frozen chicken soup products due to misbranding and an undeclared milk allergen. No adverse reactions have been reported.

    Product
    Blount Fine Foods — Blount Fine Foods Recalls Ready-To-Eat Chicken Soup Product due to Misbranding and an Undeclared Allergen
    Category
    Food
    Distribution
    Distributed nationwide
  • HighCPSC·19099·2019-04-04

    Vivitar Recalls Hot/Cold Massage Balls Due to Burn Hazard

    Vivitar is recalling hot/cold massage balls sold at Target because they can leak or rupture during microwaving, posing a burn hazard.

    Product
    Hot/cold massage balls
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1085-2019·2019-04-03

    Blue Fusion Capsules Recalled for Undeclared Prescription Ingredients

    Ata International Inc is recalling Blue Fusion Capsules because FDA analysis found undeclared prescription ingredients, including Sildenafil and Tadalafil.

    Product
    Blue Fusion Capsules, 1- count blister pack, Distributed by: DNS Distribution 5225 Canyon Crest Dr. Ste 71-640, Riverside, CA 92507, UPC 7 48252 66460 0
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1203-2019·2019-04-03

    Bauer's Candies Recalls QVC Christmas Bags Due to Hepatitis A Risk

    Bauer's Candies is recalling QVC 3/8 oz Christmas bags due to a risk of Hepatitis A exposure. The product was distributed to retail locations and private individuals in multiple states.

    Product
    QVC 3/8 oz bags for Christmas
    Category
    Food
    Distribution
    26 states
  • SevereFDA (Food)·F-1206-2019·2019-04-03

    Bauer's Candies Recalls 8 oz Modjeskas Due to Hepatitis A Risk

    Bauer's Candies is recalling 8 oz assorted modjeskas and chocolate modjeskas due to a risk of Hepatitis A exposure. The products were distributed to retail locations in Kentucky and Illinois and to private individuals in 27 states and Iceland.

    Product
    8 oz assorted modjeska/chocolate modjeskas
    Category
    Food
    Distribution
    26 states
  • SevereFDA (Devices)·Z-0986-2019·2019-04-03

    Maquet Cardiohelp Emergency Drive Recalled for Gearwheel Assembly Defect

    Maquet Cardiovascular is recalling 10 units of the Cardiohelp Emergency Drive because the gearwheel may have been incorrectly reassembled, leading to inadequate operation.

    Product
    Cardiohelp Emergency Drive, Part No. 70104.8002 Product Usage: The Cardiohelp Emergency Drive is used in emergencies to manually drive the disposable if the Cardiohelp-i fails.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1204-2019·2019-04-03

    Bauer's Candies Recalls Salted Combo Modjeskas Due to Hepatitis A Risk

    Bauer's Candies, Inc. is recalling 1 lb salted combo modjeskas due to a risk of Hepatitis A exposure. The product was distributed to retail locations in Kentucky and Illinois, and to private individuals in multiple states and Iceland.

    Product
    1 lb salted combo modjeskas
    Category
    Food
    Distribution
    26 states
  • SevereFDA (Food)·F-1202-2019·2019-04-03

    Bauer's Candies Recalls Salted Combo Modjeskas Due to Hepatitis A Risk

    Bauer's Candies, Inc. is recalling 1 lb salted combo modjeskas due to a risk of Hepatitis A exposure. The product was distributed to retail locations and private individuals in multiple states.

    Product
    1 lb salted combo modjeskas
    Category
    Food
    Distribution
    26 states
  • SevereFDA (Food)·F-1195-2019·2019-04-03

    Bauer's Candies Recalls Sea Salt Modjeskas Due to Hepatitis A Risk

    Bauer's Candies, Inc. is recalling Sea Salt Modjeskas due to a risk of Hepatitis A exposure. The candy was distributed to retail locations and private individuals in multiple states.

    Product
    Sea Salt Bauer's Candies Modjeskas NET WT 8 oz bag, bulk, 4 oz bag, 1 lb, 2 lb, 8 oz box
    Category
    Food
    Distribution
    26 states
  • SevereFDA (Food)·F-1201-2019·2019-04-03

    Bauer's Candies Recalls Candy Combos Due to Hepatitis A Exposure Risk

    Bauer's Candies, Inc. is recalling various candy combos due to a risk of Hepatitis A exposure. The products were distributed to retail locations and private individuals in multiple states.

    Product
    1 lb QVC combo, 1 lb combo, 2 lb combo, 12 oz combo, 8 oz combo, holiday combo
    Category
    Food
    Distribution
    26 states
  • SevereFDA (Food)·F-1199-2019·2019-04-03

    Bauer's Candies Recalls Bulk Chocolate Caramels Due to Hepatitis A Risk

    Bauer's Candies, Inc. is recalling bulk chocolate caramels due to a risk of Hepatitis A exposure. The product was distributed to retail locations and private individuals in multiple states.

    Product
    bulk chocolate caramels
    Category
    Food
    Distribution
    26 states
  • SevereFDA (Food)·F-1194-2019·2019-04-03

    Bauer's Chocolate Modjeskas Recalled for Hepatitis A Exposure Risk

    Bauer's Candies is recalling Chocolate Modjeskas due to a risk of Hepatitis A exposure. The products were distributed to retail locations and private individuals in multiple states.

    Product
    Bauer's Candies Chocolate Modjeskas NET WT 4 oz & 8 oz bags, 8 oz box, bulk, & 1 lb box
    Category
    Food
    Distribution
    26 states
  • SevereFDA (Food)·F-1198-2019·2019-04-03

    Bauer's Candies Recalls Bulk Assorted Candy Due to Hepatitis A Risk

    Bauer's Candies, Inc. is recalling 2 cases of bulk assorted candy due to a risk of Hepatitis A exposure. The product was distributed to retail locations and private individuals in multiple states.

    Product
    Bulk assorted
    Category
    Food
    Distribution
    26 states