The Recall Desk

State

New Jersey product recalls

73,809 recalls have nationwide distribution and so reach New Jersey. 9,782 additional recalls listed New Jersey specifically in their distribution scope.

What the numbers show

Total
9,782
Critical
1,246
Severe
2,944
Most recent
2026-11-04

Of the 9,782 recalls naming New Jersey we have scored against our rubric, 1,246 (13%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,944 (30%) are Severe.

These figures cover only the 9,782 recalls whose distribution notice names New Jersey specifically. The 73,809 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

39126–39150 of 83591

  • LowFDA (Drugs)·D-1067-2019·2019-04-10

    Pfizer Recalls Cleocin Phosphate Injection Due to Impurity Failures

    Pfizer is recalling specific lots of Cleocin Phosphate injection because high out-of-specification impurities were detected at the 24-month time point.

    Product
    CLEOCIN PHOSPHATE — CLEOCIN PHOSPHATE (CLINDAMYCIN PHOSPHATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V283000·2019-04-09

    Proterra Recalls 2015-2018 Catalyst Buses Due to Brake Fire Risk

    Proterra is recalling 2015-2018 Catalyst 40 buses because a clogged tow fitting cap can cause rear brakes to overheat and catch fire.

    Product
    PROTERRA — PROTERRA CATALYST
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V282000·2019-04-09

    Peterbilt 520 Recall: Undersized Wires May Cause Engine Shutdown

    PACCAR is recalling 2017-2020 Peterbilt 520 trucks because undersized wires may overheat and melt, potentially causing an unexpected engine shutdown and increasing crash risk.

    Product
    PETERBILT — PETERBILT 520
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V281000·2019-04-09

    Horton Ambulances Recalled for Reversed Backup Camera Image

    Halcore Group is recalling 2016-2019 Horton ambulances because backup camera displays may revert to factory settings, causing the image to reverse and increasing crash risk.

    Product
    HORTON — HORTON TYPE I, TYPE III
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V284000·2019-04-09

    Daimler Recalls 2019 Sprinter Vans for Headlight Sensor Calibration Issues

    Daimler Vans USA is recalling 2019 Freightliner and Mercedes-Benz Sprinter vans because the headlamp range adjustment sensor may not be calibrated, potentially affecting driver visibility.

    Product
    FREIGHTLINER — FREIGHTLINER, MERCEDES-BENZ SPRINTER 3500, SPRINTER 2500
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V276000·2019-04-09

    AEV TraumaHawk Ambulances Recalled for Reversed Backup Camera Image

    Halcore Group is recalling 2016-2019 AEV TraumaHawk ambulances because backup camera displays may revert to factory settings, causing the image to reverse and increasing crash risk.

    Product
    AEV — AEV TRAUMAHAWK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·19V280000·2019-04-09

    Pierce Frontline Vehicles Recalled for Brake Light Wiring Defect

    Pierce is recalling 2018-2019 Frontline C-35X, C-25, C-45X-3, and Encore Rescue vehicles because brake lights may illuminate without the pedal being pressed.

    Product
    FRONTLINE — FRONTLINE C-35X, C-25, ENCORE RESCUE, C-45X-3
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·19102·2019-04-09

    Marpac Recalls GO Travel Sleep Sound Machines Due to Burn Hazard

    Marpac is recalling GO travel sleep sound machines because the internal battery can leak and cause an electrical short, posing a burn hazard.

    Product
    GO travel sleep sound machines
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V279000·2019-04-08

    Load Trail Recalls 2018-2019 Dump Trailers Due to Bolt Failure Risk

    Load Trail is recalling 2018-2019 dump trailers because bolts on the hydraulic cylinder can break under heavy loads, causing the dump box to lower rapidly.

    Product
    LOAD TRAIL — LOAD TRAIL TANDEM AXLE DUMP, TRIPLE AXLE DUMP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V278000·2019-04-08

    Ford Recalls F-Series Trucks Due to Block Heater Fire Risk

    Ford is recalling 2015-2019 F-150 and 2017-2019 Super Duty trucks because a damaged block heater cable could cause a fire.

    Product
    FORD — FORD F-250 SD, F-350 SD, F-150, F-550 SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V274000·2019-04-05

    Nova Bus Recalls 2011-2019 LFS City Buses for Fire Risk

    Nova Bus is recalling 2011-2019 LFS city buses because an engine door fan electrical connector may overheat and cause a fire.

    Product
    NOVA BUS — NOVA BUS LFS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·042-2019·2019-04-05

    J&J Snack Foods Recalls Stuffed Sandwiches Due to Plastic Contamination

    J&J Snack Foods Handhelds Corp. is recalling Bremer hot stuffed sandwiches due to possible semi-transparent plastic contamination. No illnesses have been reported.

    Product
    J&J Snack Foods Handhelds Corp. — J&J Snack Foods Handhelds Corp. Recalls Stuffed Sandwich Products due to Possible Foreign Matter Contamination
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·19V275000·2019-04-05

    Kenworth T680 and T880 Recalled for Parking Brake Signal Delay

    PACCAR is recalling 2018-2020 Kenworth T680 and T880 trucks because a parking brake signal delay in cold weather may cause unexpected vehicle movement.

    Product
    KENWORTH — KENWORTH T680, T880
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·19V273000·2019-04-04

    BMW Recalls 2006 Models Due to PCV Valve Fire Risk

    BMW is recalling 2006 3, 5, and Z4 series vehicles because a heater in the PCV valve may short circuit, increasing the risk of a fire.

    Product
    BMW — BMW Z4, 530XI, 525I, 325XI
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereUSDA FSIS·041-2019·2019-04-04

    Blount Fine Foods Recalls Chicken Soup for Undeclared Milk Allergen

    Blount Fine Foods is recalling frozen chicken soup products due to misbranding and an undeclared milk allergen. No adverse reactions have been reported.

    Product
    Blount Fine Foods — Blount Fine Foods Recalls Ready-To-Eat Chicken Soup Product due to Misbranding and an Undeclared Allergen
    Category
    Food
    Distribution
    Distributed nationwide
  • HighCPSC·19099·2019-04-04

    Vivitar Recalls Hot/Cold Massage Balls Due to Burn Hazard

    Vivitar is recalling hot/cold massage balls sold at Target because they can leak or rupture during microwaving, posing a burn hazard.

    Product
    Hot/cold massage balls
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Drugs)·D-1085-2019·2019-04-03

    Blue Fusion Capsules Recalled for Undeclared Prescription Ingredients

    Ata International Inc is recalling Blue Fusion Capsules because FDA analysis found undeclared prescription ingredients, including Sildenafil and Tadalafil.

    Product
    Blue Fusion Capsules, 1- count blister pack, Distributed by: DNS Distribution 5225 Canyon Crest Dr. Ste 71-640, Riverside, CA 92507, UPC 7 48252 66460 0
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1185-2019·2019-04-03

    Utz Recalls Bachman Pretzels Due to Undeclared Milk Allergen

    Utz Quality Food is recalling Bachman Original Twist Pretzels because butter pretzels were mistakenly packaged in regular pretzel bags, creating an undeclared milk allergen hazard.

    Product
    Bachman Original Twist Pretzels,10 oz.Bag (flexible film) UPC: 0-77817-10580-8
    Category
    Food
    Distribution
    12 states
  • SevereFDA (Devices)·Z-0986-2019·2019-04-03

    Maquet Cardiohelp Emergency Drive Recalled for Gearwheel Assembly Defect

    Maquet Cardiovascular is recalling 10 units of the Cardiohelp Emergency Drive because the gearwheel may have been incorrectly reassembled, leading to inadequate operation.

    Product
    Cardiohelp Emergency Drive, Part No. 70104.8002 Product Usage: The Cardiohelp Emergency Drive is used in emergencies to manually drive the disposable if the Cardiohelp-i fails.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1053-2019·2019-04-03

    Philips UroDiagnost MRF Recall Due to Missing Locking Plate

    Philips is recalling UroDiagnost MRF units because a missing locking plate may cause unexpected stand or table tilt movement that users cannot stop.

    Product
    Urodiagnost, Product No. 708033 Product Usage: The Philips UroDiagnost MRF can be used to perform all urological and gynecological routine examinations including: Urograms with injection or infusion Retrograde pyelography Cystography and urethrography Micturition…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1054-2019·2019-04-03

    Philips OmniDiagnost X-ray System Recalled for Missing Locking Plate

    Philips North America is recalling 1,696 OmniDiagnost Classic X-ray systems because a missing locking plate may cause unexpected stand or table movement that users cannot stop.

    Product
    Omnidiagnost Classic, Product Codes 70859, 708023, 708024, 708025 Product Usage: The Philips OmniDiagnost is a multi-functional, universal X-ray system with remote-controlled facilities. It performs a wide range of routine examinations and interventional procedures include…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1187-2019·2019-04-03

    Jacques Big Daddy Dark Chocolate Bar Recalled for Undeclared Milk

    Jacques Torres Manufacturing is recalling Big Daddy Dark Chocolate Bars because they contain undeclared milk, posing a risk to consumers with milk allergies.

    Product
    Jacques Big Daddy Dark Chocolate Bar. The product comes in un-coded 2.2 lbs. (1kg) clear plastic package overwrapped with reddish brown paper label.
    Category
    Food
    Distribution
    17 states
  • HighNHTSA·19V269000·2019-04-03

    Weis Fire & Safety Recalls One 2018 Ford F-550 Emergency Vehicle

    Weis Fire & Safety is recalling one 2018 Ford F-550 emergency vehicle because its brake lights may illuminate without the brake pedal being pressed, potentially confusing other drivers.

    Product
    FORD — FORD F-550
    Category
    Vehicle
    Distribution
    Distributed nationwide