The Recall Desk

State

Nebraska product recalls

73,741 recalls have nationwide distribution and so reach Nebraska. 4,580 additional recalls listed Nebraska specifically in their distribution scope.

What the numbers show

Total
4,580
Critical
713
Severe
1,345
Most recent
2026-10-28

Of the 4,580 recalls naming Nebraska we have scored against our rubric, 713 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,345 (29%) are Severe.

These figures cover only the 4,580 recalls whose distribution notice names Nebraska specifically. The 73,741 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

37576–37600 of 78321

  • HighFDA (Devices)·Z-0871-2019·2019-03-06

    Philips Multiva MRI System Recalled for Falling Ceiling Speaker Hazard

    Philips is recalling Multiva 1.5T MRI systems because ceiling speakers may fall and be pulled by the magnetic field.

    Product
    Multiva 1.5T 8 R5 (ZBO), Model Number 781072. Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0883-2019·2019-03-06

    Philips Intera 3.0T MRI System Recalled for Ceiling Speaker Hazard

    Philips is recalling Intera 3.0T MRI systems because ceiling speakers may fall due to magnetic attraction.

    Product
    Intera 3.0T Master/Quasar Dual, Model Number 781150. Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0941-2019·2019-03-06

    Arrow AutoFuser Disposable Pain Control Pump Recalled for Potential Cracks

    Arrow International Inc. is recalling Arrow AutoFuser Disposable Pain Control Pumps due to possible cracks on the fill port connector that may cause leaks and reduced drug delivery.

    Product
    AF w/AS 550x 0.5 7 ml/hr, 5ml 30 LO CPNB, Product code MVAX30XL CPNB, Arrow AutoFuser Disposable Pain Control Pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0956-2019·2019-03-06

    Arrow AutoFuser Disposable Pain Control Pump Recalled for Potential Leaks

    Arrow International Inc. is recalling Arrow AutoFuser Disposable Pain Control Pumps due to possible cracks on the fill port connector that may cause leaks and reduced drug delivery.

    Product
    AF w/AS 550 x 1-14ML/HR 5ML-60LO CPNB, Product code MVBX60XL CPNB, Arrow AutoFuser Disposable Pain Control Pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0898-2019·2019-03-06

    Philips Panorama 1.0T MRI System Recalled for Ceiling Speaker Hazard

    Philips is recalling Panorama 1.0T MRI systems because ceiling speakers may fall and be pulled by the magnetic field.

    Product
    Panorama 1.0T, Model Number 781250. Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0942-2019·2019-03-06

    Arrow AutoFuser Disposable Pain Control Pump Recalled for Potential Cracks

    Arrow International Inc. is recalling 8 units of the Arrow AutoFuser Disposable Pain Control Pump due to possible cracks on the fill port connector that may cause leaks.

    Product
    AF550x5ML/H 2ML 60LO 6" CATH, 4.5" IN, Product code MT5060XLSK5 CP, Arrow AutoFuser Disposable Pain Control Pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0939-2019·2019-03-06

    Merge Eye Station Retinal Imager Recalled for Electrical Safety Defects

    Merge Healthcare is recalling 1,252 WinStation Retinal Imagers because certain configurations may produce electrical output exceeding allowable medical device limits.

    Product
    The WinStation Retinal Imager, also known as Merge Eye Station. DCF-1024 & DCF-512 Digital Imaging System Product Usage: The WinStation Retinal Imager has the same intended use as other fundus cameras. It is specifically used to produce color or black and white images of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0949-2019·2019-03-06

    Arrow AutoFuser Disposable Pain Control Pump Recalled for Potential Cracks

    Arrow International Inc. is recalling 9 units of the Arrow AutoFuser Disposable Pain Control Pump due to possible cracks on the fill port connector that may cause leaks.

    Product
    AF 550 x 5ML/HR CPNB, Product code MC0050XL CPNB, Arrow AutoFuser Disposable Pain Control Pump
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0872-2019·2019-03-06

    Philips Multiva MRI System Recalled for Ceiling Speaker Hazard

    Philips is recalling Multiva 1.5T MRI systems because ceiling speakers may fall due to magnetic attraction.

    Product
    Multiva 1.5T 16 R5 (ZBO), Model Number 781073. Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0887-2019·2019-03-06

    Philips MRI System Recall for Falling Ceiling Speaker Hazard

    Philips is recalling Intera Achieva 1.5T Pulsar MRI systems because ceiling speakers may fall due to magnetic attraction.

    Product
    Intera Achieva 1.5T Pulsar, Model Number 781171. Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0961-2019·2019-03-06

    Alcon Ophthalmic Microscope Recalled for Potential Optical Head Detachment

    Alcon is recalling LuxOr E71 and E71 Q-Vue ophthalmic microscopes because the optical head may detach from the stand due to missing thread adhesive.

    Product
    Alcon or Endure Ophthalmic Microscope Product Usage: Used for low magnification visualization during ophthalmic surgical procedures for cataract, retina and cornea.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0925-2019·2019-03-06

    Philips MR-OR 3.0T MRI Systems Recalled for Falling Speaker Hazard

    Philips is recalling 11,226 MR-OR 3.0T MRI systems because ceiling speakers may fall and be pulled by the magnetic field.

    Product
    MR-OR 3.0T, Model Number 781438. Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0899-2019·2019-03-06

    Philips Achieva XR MRI Systems Recalled for Falling Speaker Hazard

    Philips is recalling Achieva XR MRI systems because ceiling speakers may fall and be pulled by the magnetic field.

    Product
    Achieva XR 1.5T/3.0T , Model Number 781253. Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0909-2019·2019-03-06

    Philips Achieva MRI Systems Recalled Due to Ceiling Speaker Hazard

    Philips is recalling 11,226 Achieva 1.5T MRI systems because ceiling speakers may fall and be pulled by the magnetic field.

    Product
    Achieva 1.5T, Model Number 781296. Nuclear Magnetic Resonance Imaging System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-1097-2019·2019-03-06

    Planetary Herbals Mullein Lung Complex Recalled for Labeling Error

    Planetary Herbals is recalling Mullein Lung Complex capsules due to a labeling error regarding inactive ingredients.

    Product
    Planetary Herbals Mullein Lung Complex; 1000 mg; 15 count, item number PF0003; 90 count - Item number PF0002; 180 count, Item number PF0106 and 90 + 90 count, PF 7013 white plastic bottles. Proprietary Blend: Platycodon root, Ophiopagon Rhizome, Long Pepper Fruit, Black…
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-1054-2019·2019-03-06

    King Orchards Tart Cherry Concentrate Recalled for Incorrect Sugar Labeling

    King Orchards is recalling Montmorency Tart Cherry Concentrate because the nutrition label lists 1g of sugar per serving instead of the actual 15g.

    Product
    Montmorency Tart Cherry Concentrate 100% Juice 32-oz bottle (sold individual and 12 per case), 16-oz bottle (sold individual and 12 per case), and 1-oz packet (sold individual and per 25, 50, 100, 250, 300, and 1000)
    Category
    Food
    Distribution
    20 states
  • ModerateFDA (Devices)·Z-0933-2019·2019-03-06

    Becton Dickinson Recalls Phoenix AST-s Indicator Due to Test Aborts

    Becton Dickinson is recalling Phoenix AST-s Indicator lots because they cause increased test aborts. The products were distributed to 41 US states and 33 foreign countries.

    Product
    Phoenix AST-s Indicator, Catalog Number 246009
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-0967-2019·2019-03-06

    Cook Inc. Recalls Gastrointestinal Suture Anchor Sets Due to Retention Mechanism Issue

    Cook Inc. is recalling 797 Entuit Secure Gastrointestinal Suture Anchor Sets because a specific extension spring lot may cause difficulty sliding the retention mechanism.

    Product
    Entuit Secure Gastrointestinal Suture Anchor Set, Catalog Number GIAS-SRM-2, Order Number G35569 The Entuit Secure Gastrointestinal Suture Anchor Set is intended for anchoring the anterior wall of the stomach to the abdominal wall prior to the introduction of interventional…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0959-2019·2019-03-06

    Shimadzu BRANSIST safire Digital Angiography System Software Recall

    Shimadzu Medical Systems is recalling eight BRANSIST safire digital angiography systems due to a software error that can cause abnormal termination during initial patient registration.

    Product
    BRANSIST safire Product Usage: DIGITAL ANGIOGRAPHY SYSTEM This system is intended to be used for radiologic visualization of the heart, blood vessels or lymphatic system during or after injection of a contrast medium. It is to be used in the diagnosis of the circulatory…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0968-2019·2019-03-06

    Cook Inc. Recalls Gastrointestinal Suture Anchor Sets Due to Retention Mechanism Issue

    Cook Inc. is recalling 975 Entuit Secure Gastrointestinal Suture Anchor Sets because a specific extension spring lot may cause difficulty sliding down the retention mechanism.

    Product
    Entuit Secure Gastrointestinal Suture Anchor Set, Catalog Number GIAS-SRM-3, Order Number G35570 The Entuit Secure Gastrointestinal Suture Anchor Set is intended for anchoring the anterior wall of the stomach to the abdominal wall prior to the introduction of interventional…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0935-2019·2019-03-06

    Becton Dickinson Recalls Phoenix AP AST Indicator Bags Due to Test Aborts

    Becton Dickinson is recalling Phoenix AP AST Indicator Bags because certain lots cause increased test aborts. The products were distributed to 40 US states and 33 foreign countries.

    Product
    Phoenix AP AST Indicator Bag, Catalog Number 246006
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-0960-2019·2019-03-06

    Abbott Vascular Recalls PLUS 30 Priority Pack Accessory Kit Due to Expiration Error

    Abbott Vascular is recalling 26 units of the PLUS 30 Priority Pack Accessory Kit because an incorrect expiration date was entered for one lot.

    Product
    PLUS 30 PRIORITY PACK Accessory Kit Product Usage: Is recommended for use during vascular procedures in conjunction with interventional and / or diagnostic devices (e.g., balloon dilatation catheters, atherectomy devices, stent delivery systems, intravascular ultrasound…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0934-2019·2019-03-06

    Becton Dickinson Recalls Phoenix AST Indicator Due to Test Aborts

    Becton Dickinson is recalling Phoenix AST Indicator lots because panels show increased test aborts. The recall covers 62,880 units distributed in the US and 33 foreign countries.

    Product
    Phoenix AST Indicator, Catalog Number 246004
    Category
    Medical Device
    Distribution
    42 states
  • LowFDA (Drugs)·D-0517-2019·2019-03-06

    Lupin Recalls Moxifloxacin Ophthalmic Solution Due to Impurity Levels

    Lupin Pharmaceuticals is recalling Moxifloxacin Ophthalmic Solution because impurity levels exceeded specifications. The recall covers 674,628 bottles distributed nationwide and in Puerto Rico.

    Product
    MOXIFLOXACIN — MOXIFLOXACIN (MOXIFLOXACIN)
    Category
    Drug
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0958-2019·2019-03-06

    Exactech Equinoxe Humeral Stem Recalled for Incorrect Packaging Instructions

    Exactech is recalling 40 Equinoxe Preserve Humeral Stems because they may have been packaged with instructions for a different knee implant.

    Product
    Equinoxe Preserve Humeral Stem, 8mm Product Usage: The Equinoxe Preserve Stems are indicated for use in skeletally mature individuals with degenerative diseases of the glenohumeral joint where anatomic total arthroplasty,anatomic hemi-arthroplasty,or reverse total…
    Category
    Medical Device
    Distribution
    Distributed nationwide