The Recall Desk

State

Northern Mariana Islands product recalls

73,833 recalls have nationwide distribution and so reach Northern Mariana Islands. 23 additional recalls listed Northern Mariana Islands specifically in their distribution scope.

What the numbers show

Total
23
Critical
0
Severe
18
Most recent
2026-09-23

Of the 23 recalls naming Northern Mariana Islands we have scored against our rubric, 0 (0%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 18 (78%) are Severe.

Which agencies issued them

These figures cover only the 23 recalls whose distribution notice names Northern Mariana Islands specifically. The 73,833 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

60926–60950 of 73856

  • HighFDA (Devices)·Z-0143-2014·2013-11-13

    Baxter Recalls Dual Luer Lock Caps Due to Loose Particulate Matter

    Baxter Healthcare is recalling specific lots of Dual Luer Lock Caps because loose particulate matter was found in the packaging, posing a risk of embolic events.

    Product
    Dual Luer Lock Cap The device is intended for use as a cap for male or female Luer ports on medical devices such as manifolds, stopcocks or sets.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0149-2014·2013-11-13

    Ethicon Endo-Surgery Recalls Adjustable Gastric Bands Due to Locking Failure

    Ethicon Endo-Surgery Inc is recalling adjustable gastric bands because they failed to meet force-to-lock requirements during aging studies.

    Product
    Adjustable Gastric Band, packaged alone in transparent PETG inner and outer blisters with Tyvek lids, or in various kit configurations with one band per kit. Product Usage: Intended for use in surgical treatment of morbid obesity
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0169-2014·2013-11-13

    Vital Images Recalls VitreaCore Software Due to Image Orientation Defect

    Vital Images, Inc. is recalling VitreaCore software versions 6.0 through 6.5 due to a potential for incorrect or reversed image orientation in certain snapshots.

    Product
    VitreaCore¿ software. Versions subject to the limitation: 6.0, 6.1, 6.2, 6.3 (except 6.3.1 ), 6.4 (except 6.4.4 and 6.4.5), as well as their upgrades, and 6.5. The VitreaCore (ViTALConnect) system is a medical diagnostic software system intended to process, analyze…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·13V566000·2013-11-13

    GM Recalls 2013 Chevrolet Malibu for Power Seat Wiring Fire Risk

    General Motors is recalling 2013 Chevrolet Malibus with 8-way power seats because the wiring harness may chafe, potentially causing a short circuit or fire.

    Product
    CHEVROLET — CHEVROLET MALIBU
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0181-2014·2013-11-13

    Siemens Healthcare Recalls Emit 2000 Phenobarbital Assay Due to Imprecision

    Siemens Healthcare Diagnostics is recalling specific lots of the Emit 2000 Phenobarbital Assay because they may produce imprecise results. The recall covers units distributed in the US and Mexico.

    Product
    Emit 2000 Phenobarbital Assay and Syva Emit 2000 Phenobarbital Assay
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0175-2014·2013-11-13

    Mesa Laboratories Recalls pH 7.0 Buffer Solution Due to Mold Growth

    Mesa Laboratories is recalling specific lots of pH 7.0 Buffer Solution bottles because of mold growth. The product is used to calibrate pH meters in hemodialysis settings.

    Product
    pH 7.0 Buffer Solution Pint and Quart Bottles, Part Number 02.0030 for Pints and 02.0031 for Quarts. Packaged in Plastic Bottles. Can be sold individually or in cartons with 6 bottles per box (for quart bottles only). Used in the hemodialysis setting to calibrate pH meters.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0127-2014·2013-11-13

    Stryker Recalls Dekompressor Percutaneous Discectomy Probes Due to Fracture Risk

    Stryker is recalling Dekompressor Percutaneous Discectomy Probes because the auger or cannula may fracture if the device is manually bent, potentially requiring additional medical intervention.

    Product
    Dekompressor Percutaneous Discectomy Probe. The Dekompressor is a single use disposable discectomy probe that passes through and works in conjunction with an introducer cannula to remove intervertebral disc nucleus pulposus material.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0164-2014·2013-11-13

    Smiths Medical Recalls Portex Spinal Trays with Particulate Contamination

    Smiths Medical is recalling Portex Spinal Anaesthesia Trays because visual particulate was found in the included Lidocaine and Dextrose ampules.

    Product
    Portex¿ Saddleblock Tray with Drugs  25g Quincke; 4795-20 The Regional Anesthesia family of products is comprised of sterile (unless otherwise indicated in the product scope), single-use devices designed to perform epidural, spinal, combined epidural/spinal, nerve block…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0119-2014·2013-11-13

    Irwin Naturals Recalls Dual Action Cleanse Due to Chloramphenicol Contamination

    Irwin Naturals is recalling Dual Action Cleanse and Daily Digestive Enzymes because they may be contaminated with chloramphenicol.

    Product
    Dual Action Cleanse by Cellular Research Formulas with Green Tea Bonus 60 ct, Item AN056906E, UPC Code: 7 10363 56906 8
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0171-2014·2013-11-13

    Handicare Bath Bliss Handset Recall for Inoperable Lifts

    Handicare Accessibility is recalling 3,301 handsets for Minivator Bath Bliss Reclining Bath Lifts because two units became inoperable while users were in the tub.

    Product
    Handset component of the Handicare USA's Minivator Bath Bliss Reclining Bath Lifts (Bath Bliss), Part Number BP300-100/BP300-400RSUS (handset) - Model Numbers BBR0311USAB (blue) and BBR0311USSS (silver) Handset component devices operate the Minivator Bath Bliss Reclining Bath…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0157-2014·2013-11-13

    Portex Spinal Trays Recalled Due to Visual Particulate in Lidocaine Ampules

    Smiths Medical ASD is recalling 73 Portex Spinal Trays because visual particulate was found in the included Lidocaine HCL ampules.

    Product
    Portex¿ Spinal Tray with Drugs 22g/25g Quincke; 15249-21 The Regional Anesthesia family of products is comprised of sterile (unless otherwise indicated in the product scope), single-use devices designed to perform epidural, spinal, combined epidural/spinal, nerve block…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0147-2014·2013-11-13

    Beckman Coulter Recalls UniCel DxH 800 and DxH 600 Hematology Analyzers

    Beckman Coulter is recalling 1,025 UniCel DxH 800 and DxH 600 hematology analyzers because specific check valves may fail, potentially causing air or liquid leaks.

    Product
    UniCel DxH 800 and DxH 600 Coulter Cellular Analysis Systems The UniCel DxH 800/DxH 600 analyzers are quantitative, multiparameter, automated hematology analyzers for in vitro diagnostic use in screening patient populations found in clinical laboratories. The DxH 800 is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0016-2014·2013-11-13

    Siemens Fluoroscopic X-Ray Systems Recalled for Potential Radiation Malfunction

    Siemens is recalling 23 fluoroscopic X-ray systems due to a potential malfunction that may cause radiation to continue longer than expected, resulting in unnecessary dose.

    Product
    Siemens RAD Fluoro Uro Systems - Luminos dRF, Ysio and Uroskop Omnia with software versions VB10D, VB10F, VB10C and VB10E. Fluroscopic X-Ray Systems
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0158-2014·2013-11-13

    Smiths Medical Recalls Portex Spinal Trays with Particulate Contamination

    Smiths Medical ASD, Inc. is recalling Portex Spinal Trays because visual particulate was found in the included Lidocaine and Dextrose ampules.

    Product
    Portex¿ Spinal Tray with Drugs 25g Whitacre; 15545C-21 The Regional Anesthesia family of products is comprised of sterile (unless otherwise indicated in the product scope), single-use devices designed to perform epidural, spinal, combined epidural/spinal, nerve block, lumbar…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0150-2014·2013-11-13

    Ethicon Adjustable Gastric Band Recalled for Force to Lock Failure

    Ethicon Endo-Surgery Inc is recalling 2,475 Adjustable Gastric Bands because aging studies showed they failed to meet Force to Lock test requirements.

    Product
    Adjustable Gastric Band, packaged alone in transparent PETG inner and outer blisters with Tyvek lids. Product Usage: Intended for use in surgical treatment of morbid obesity
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0134-2014·2013-11-13

    Edwards Lifesciences Recalls Fem-Flex Femoral Arterial Cannulas Due to Cracks

    Edwards Lifesciences is recalling two lots of Fem-Flex Femoral Arterial Cannulas because cracks were found in the t-connectors during product evaluation.

    Product
    Edwards Lifesciences Fem-Flex Femoral Arterial Cannula with Duraflo Coating, DIITFA02225, Sterile, RX only For Single Use Only, Product Usage: Edwards Lifesciences femoral access cannulae are intended for use in situations which require rapid femoral venous and arterial…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0154-2014·2013-11-13

    Medtronic Resolute Integrity Coronary Stent Recall for Incorrect Compliance Chart Labeling

    Medtronic is recalling 201 units of Resolute Integrity Zotarolimus-eluting Coronary Stents because the compliance chart may incorrectly reference a 2.25 mm diameter instead of the correct 3.0 mm.

    Product
    Resolute Integrity Zotarolimus-eluting Coronary Stent: Stent ID 3.0 mm; Stent length 34 mm; Rx, Sterile. Mfg in Medtronic Ireland, Galaway, Ireland. Distributed by: Medtronic Inc. Minneapolis, MN. Indicated for improving coronary luminal diameters in patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0179-2014·2013-11-13

    Carestream DRX-Revolution Mobile X-Ray Systems Software Patch Recall

    Carestream Health is voluntarily installing a software patch on DRX-Revolution mobile X-ray systems to address reports of non-diagnostic images during normal exposure exams.

    Product
    DRX- Revolution, Catalog number: 101937, 1023415 & 1023423. Made in U.S.A. by Carestream Health, Inc. 150 Verona Street Rochester, NY 14608 to perform radiographic x-ray examinations on all pediatric and adult patients
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0132-2014·2013-11-13

    Carestream DRX Revolution Mobile X-Ray System Column Cover Recall

    Carestream Health is recalling DRX Revolution mobile x-ray systems because the column end cover may dislodge from the column.

    Product
    DRX Revolution, Catalog #'s 1)1019397, 2) 1023415 (w/ installation warranty, US-only) and 3) 1023423 (w/ parts warranty, US-only). The device is designed to perform radiographic x-ray examinations on all pediatric and adult patients, in all patient treatment areas
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0136-2014·2013-11-13

    Bayer A1CNow+ Test Kits Recalled for Potential Inaccurate Results

    Bayer is recalling A1CNow+ test kits because they may produce high-bias readings if stored at room temperature for 4 to 5 months.

    Product
    Bayer brand A1CNow+ MULTI-TEST A1C SYSTEM TEST KITS (PART NUMBER 3021/08842610); Hemoglobin A1c Monitor; Glycosylated Hemoglobin Assay; Product is manufactured and distributed by Bayer HealthCare LLC, Sunnyvale, CA The A1CNow+ test provides quantitative measurement of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-66403-001·2013-11-13

    Mylan Recalls Amlodipine Besylate Tablets Due to Manufacturing Deviations

    Mylan Pharmaceuticals is recalling Amlodipine Besylate Tablets, 2.5 mg, because they were not manufactured according to Good Manufacturing Practices.

    Product
    Amlodipine Besylate Tablets, USP, 2.5 mg, packaged in a) 90-count bottles (NDC 0378-5208-77) and b) 500-count bottles (NDC 0378-5208-05), Rx only, Mylan Pharmaceuticals Inc., Morgantown, WV 26505 U.S.A.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0137-2014·2013-11-13

    ITC Surgicutt Bleeding Time Device Recalled for Loose Blades

    ITC-Nexus Dx is recalling Surgicutt bleeding time devices because the blades may be loose. The recall affects Lot AK301M distributed nationwide.

    Product
    Surgicutt fully automated incision making device for bleeding time determination. ITC 8 Olsen Avenue, Edison, NJ 08820. 732.548.5700. www.itcmed.com. A subsidiary of Thoratec Corporation. The device is a spring loaded cam driven device that provides standardized…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0130-2014·2013-11-13

    Smith & Nephew Recalls Mispackaged Genesis II Tibial Base Components

    Smith & Nephew is recalling four units of Genesis II tibial base components due to size and side mislabeling.

    Product
    GENESIS(R) II, NON-POROUS TIBIAL BASE, SIZE 5, LEFT, QTY: (1), REF 71420168. Product Usage: orthopaedic
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0145-2014·2013-11-13

    Richard Wolf Recalls S(a)line Resectoscope Vaporization Electrodes Due to Packaging Error

    Richard Wolf Medical Instruments Corp. is recalling S(a)line resectoscope vaporization electrodes because a different model was found packaged in the wrong pouch.

    Product
    Individual units labeled in part: REF: 4630022; for S(a)line resectoscopes; Vaporization electrode, sterite; 4mm telescope 30 25 / 12: only for continuous irrigation sheath 24,5 Fr.; LOT 426111; 2011/06; 2016/06; STERILE; RICHARD WOLF; Cartons of 3 units labeled in part: REF…
    Category
    Medical Device
    Distribution
    Distributed nationwide