The Recall Desk

State

Missouri product recalls

72,986 recalls have nationwide distribution and so reach Missouri. 8,465 additional recalls listed Missouri specifically in their distribution scope.

What the numbers show

Total
8,465
Critical
1,334
Severe
1,870
Most recent
2026-09-16

Of the 8,465 recalls naming Missouri we have scored against our rubric, 1,334 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,870 (22%) are Severe.

These figures cover only the 8,465 recalls whose distribution notice names Missouri specifically. The 72,986 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

7801–7825 of 81451

  • CriticalFDA (Food)·F-0578-2025·2025-03-05

    Gerber Baby Teething Sticks Recalled Due to Choking Risk

    Nestlé-USA is recalling all lots of Gerber Snacks for Baby Soothe 'n' Chew Teething Sticks in Strawberry Apple flavor following complaints of infant choking. The product was distributed across 42 states and Puerto Rico.

    Product
    Gerber Snacks for Baby Soothe 'n' Chew TEETHING STICKS Strawberry Apple NET WT 3.2 OZ (90g) UPC 0 15000 04518 7 GERBER PRODUCTS CO., FREMONT, MI 49413
    Category
    Food
    Distribution
    46 states
  • SevereFDA (Devices)·Z-1196-2025·2025-03-05

    Ventec VOCSN Ventilators Recalled Due to Incorrect Service Parts

    Ventec Life Systems recalled VOCSN Multi-Function Ventilators (30 units in CA, NY, MO) due to incorrect parts used during service. Defects may cause unexpected shutdown or impaired respiratory monitoring and support.

    Product
    VOCSN Multi-Function Ventilators: VOCSN+Pro (V+O+C+S+N+Pro, English), REF: PRT-00490-001; V+Pro (V+Pro, English), REF: PRT-01185-000, PRT-01185-002
    Category
    Medical Device
    Distribution
    3 states
  • SevereNHTSA·25V143000·2025-03-05

    Airstream Recalls Classic Travel Trailers Due to Fire Risk

    Airstream is recalling certain Classic travel trailers because the sofa footrest switch wiring may overheat, increasing the risk of a fire.

    Product
    AIRSTREAM — AIRSTREAM CLASSIC
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0579-2025·2025-03-05

    Gerber Baby Soothe 'n' Chew Teething Sticks Recalled for Choking Risk

    Gerber Snacks for Baby Soothe 'n' Chew Teething Sticks in Banana flavor are recalled nationwide due to complaints of infant choking. All lots in both 1.59 oz and 3.2 oz packages are affected.

    Product
    Gerber Snacks for Baby Soothe 'n' Chew TEETHING STICKS Banana NET WT 3.2 OZ (90g) box UPC 0 15000 04608 8 and NET WT 1.59 oz box UPC 0 15000 01015 7 GERBER PRODUCTS CO., FREMONT, MI 49413
    Category
    Food
    Distribution
    46 states
  • HighFDA (Devices)·Z-1240-2025·2025-03-05

    MRI System May Resume Scanning Above Safe Thermal Limits

    GE Healthcare's Brivo MR355 MRI system can incorrectly resume scans when tissue heating limits are exceeded, potentially causing thermal burns if patients contact conductive materials. The recall affects 22 systems distributed nationwide and internationally.

    Product
    Brivo MR355, NMRI system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0248-2025·2025-03-05

    Avastin intravitreal injection syringes recalled for sterility assurance failure

    Turbare Manufacturing recalls 1,147 syringes of Avastin 1.25 mg intravitreal injection nationwide due to a quality control process deviation affecting sterility assurance.

    Product
    Avastin 1.25 mg/0.05 mL in 0.25 mL Syringe, For Intravitreal Injection Only, Office Use Only - Not for Resale - Single Use, This drug product was repackaged by Turbare Manufacturing, 925 Jeanette Drive, Conway, AR 72032, NDC: 83556-0101-01.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1224-2025·2025-03-05

    A.L.P.S. mvX Medial Tibia Plate Locking Screw Malfunction Recall

    Tyber Medical recalls 208 units of A.L.P.S. mvX Medial Tibia Plates due to locking screws that can pass through the locking hole during surgery, causing surgical delays. No patient injuries have been reported.

    Product
    A.L.P.S. mvX--MEDIAL TIBIA PLATE 12H RT-Medial Tibia Plate, 12-Hole, Right Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770715122
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1226-2025·2025-03-05

    Medial Tibia Plate Recall Due to Locking Screw Malfunction During Surgery

    Tyber Medical recalls 109 units of the A.L.P.S. mvX Medial Tibia Plate nationwide due to reports of the locking screw passing through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- MEDIAL TIBIA PLATE 16H RT -Medial Tibia Plate, 16-Hole, Right Intended Fixation of fractures of the distal tibia Model/Catalog Number: 770715162
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1212-2025·2025-03-05

    A.L.P.S. mvX Fibula Plate Recall: Locking Screw Malfunction During Surgery

    Tyber Medical is recalling 408 units of the A.L.P.S. mvX Anatomic Lateral Fibula Plate because the locking screw can pass through the locking hole during surgery, causing surgical delays. No injuries have been reported.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 6H RT: Anatomic Lateral Fibula Plate, 6-hole, Right Model/Catalog Number: 770708062
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1215-2025·2025-03-05

    Anatomic Lateral Fibula Plate locking screw malfunction during surgery

    Tyber Medical is recalling 220 A.L.P.S. mvX Anatomic Lateral Fibula Plates due to complaints that the locking screw passes through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- Product Name: ANATOMIC LAT FIB PLATE 10H LT Anatomic Lateral Fibula Plate, 10-Hole, Left. Intended Fixation of fractures of the distal tibia Model/Catalog Number: 770708101
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1247-2025·2025-03-05

    Leica Biosystems Cryostat CM1950 Firmware Update May Cause Tissue Loss

    A software issue in the Leica Biosystems CM1950 cryostat firmware update could result in loss of patient tissue. Serial numbers 12835 and 12854 are affected.

    Product
    Brand Name: Leica Biosystems Cryostats Product Name: CM1950 Model/Catalog Number: 1491950C4US Software Version: firmware V3.01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1214-2025·2025-03-05

    Orthopedic Surgical Plates Recalled Due to Intra-Operative Locking Screw Malfunction

    Tyber Medical is recalling A.L.P.S. mvX Anatomic Lateral Fibula Plates nationwide due to reports that locking screws may pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 8H RT: Anatomic Lateral Fibula Plate, 8-hole, Right Indicated for use in Fixation of fractures of the distal tibia Model/Catalog Number: 77070802
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1216-2025·2025-03-05

    Anatomic lateral fibula plate locking screw failure during surgery

    Tyber Medical A.L.P.S. mvX anatomic lateral fibula plates (219 units nationwide) have a defect where the locking screw can pass through its locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 10H RT- Anatomic Lateral Fibula Plate, 10-Hole, Right. Intended forFixation of fractures of the distal tibia Model/Catalog Number: 770708102 Product Description:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1218-2025·2025-03-05

    Orthopedic Fixation Plates Recalled for Screw Locking Failure During Surgery

    Tyber Medical is recalling 115 A.L.P.S. mvX orthopedic plates because the locking screw can pass through the locking hole during surgery, causing surgical delays and inadequate fracture fixation.

    Product
    A.L.P.S. mvX- ANATOMIC LAT FIB PLATE 12H RT- Anatomic Lateral Fibula Plate, 12-Hole, Right. Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770708122 Product Description:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1207-2025·2025-03-05

    Automated Medication Cabinet Recalled Due to Fingerprint Scanner Overheating Risk

    CareFusion's BD Pyxis MedFlex automated medication cabinet is being recalled due to fingerprint scanner failure and overheating, posing a potential fire hazard in clinical settings.

    Product
    BD Pyxis MedFlex 2.0 REF 1139-00 Bio-ID Spare Parts REF 353200-01 The BD Pyxis" MedFlex is an Automated Dispensing Cabinet (ADC) intended to securely store and dispense medications and supplies to a qualified and authorized user in a clinical setting.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·25V144000·2025-03-05

    Mercedes-Benz Tourrider Buses Recalled for Missing Driver Seat Bracket

    Daimler Coaches is recalling 2022-2025 Mercedes-Benz Tourrider buses because a missing driver's seat bracket may allow the backrest to fold forward in a crash.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ TOURRIDER PREMIUM, TOURRIDER BUSINESS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25T002000·2025-03-05

    Sumitomo Recalls Dunlop GPR-300F Tires Due to Inner Liner Defect

    Sumitomo is recalling specific Dunlop GPR-300F tires due to a defect causing inner liner bulging. The defect may lead to sudden air loss and vehicle control issues.

    Product
    TIRES recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1211-2025·2025-03-05

    Tyber Medical recalls A.L.P.S. mvX Anatomic Lateral Fibula Plates due to screw malposition

    Tyber Medical is recalling A.L.P.S. mvX Anatomic Lateral Fibula Plates (418 units, nationwide) because the locking screw may pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX -ANATOMIC LAT FIB PLATE 6H LT- Anatomic Lateral Fibula Plate, 6-hole, Left Intended for Fixation of fractures of the distal tibia Model/Catalog Number: 770708061
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1217-2025·2025-03-05

    Orthopedic Plate Locking Screw May Pass Through Hole During Surgery

    Tyber Medical is recalling A.L.P.S. mvX-P Anatomic Lateral Fibula Plates because the locking screw may pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX-P: ANATOMIC LAT FIB PLATE 12H LT- Anatomic Lateral Fibula Plate, 12-Hole, Left. Inended for Fixation of fractures of the distal tibia Model/Catalog Number: 770708121
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1234-2025·2025-03-05

    Socrates 38 Aspiration Catheter Recall Due to Sterile Barrier Defect

    Scientia Vascular is recalling 120 Socrates 38 Aspiration Catheters due to manufacturing defects that created channels in the packaging seal. The defect could potentially compromise the sterile barrier on devices used for acute stroke treatment.

    Product
    Socrates 38 Aspiration Catheter 127 cm length REF SC038-127-001 The Socrates Aspiration System with a compatible suction pump is intended for use in the revascularization of patients with acute ischemic stroke
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0246-2025·2025-03-05

    Estradiol Gel Recalled Nationwide for Defective Packet Sealing

    Padagis US LLC recalls Estradiol Gel 0.1% nationwide due to defective packets that may not be fully sealed, potentially allowing ethanol loss.

    Product
    Estradiol Gel, 0.1%, 0.25 mg/g, 30 packets per carton, Rx Only, For Topical Use Only, Manufactured by Padagis, Yeruham, Israel, NDC: 45802-0134-30
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1223-2025·2025-03-05

    FDA Recalls Medial Tibia Plates for Intra-operative Screw Failure

    Tyber Medical is recalling A.L.P.S. mvX Medial Tibia Plates due to reports that the locking screw can pass through the locking hole during surgery, causing surgical delays.

    Product
    A.L.P.S. mvX-MEDIAL TIBIA PLATE 12H LT-Medial Tibia Plate, 12-Hole, Left Intended forFixation of fractures of the distal tibia Model/Catalog Number: 770715121
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1242-2025·2025-03-05

    MRI Systems May Resume Scans When SAR Exceeds Safe Limits

    Certain GE Healthcare MRI systems may incorrectly enable scan resumption when radiofrequency energy absorption exceeds FDA-set limits, potentially causing tissue heating. Risk is higher for patients with implants or touching conductive materials.

    Product
    SIGNA MR355, SIGNA MR360, NMRI system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1236-2025·2025-03-05

    Video Colonoscope May Cause Thermal Burns to Tissue During Use

    The PENTAX Medical Video Colonoscope (Model EC38-i20cL) can develop excessive heat at the tip during procedures, potentially causing thermal burns to patient tissue. Users reported dark images and steam-like smoke from the device.

    Product
    PENTAX Medical Video Colonoscope- Intended to provide optical visualization of (via a video monitor), and therapeutic access to the lower gastrointestinal tract Model: EC38-i20cL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1221-2025·2025-03-05

    Medial Tibia Plate Recall: Locking Screw Defect During Surgery

    Tyber Medical is recalling A.L.P.S. mvX Medial Tibia Plates because the locking screw may not properly secure during surgery, causing surgical delays. No injuries have been reported.

    Product
    A.L.P.S. mvX- MEDIAL TIBIA PLATE 10H LT- Medial Tibia Plate, 10-Hole, Left. Intended Fixation of fractures of the distal tibia Model/Catalog Number: 770715101
    Category
    Medical Device
    Distribution
    Distributed nationwide