The Recall Desk

State

Missouri product recalls

73,905 recalls have nationwide distribution and so reach Missouri. 8,503 additional recalls listed Missouri specifically in their distribution scope.

What the numbers show

Total
8,503
Critical
1,339
Severe
2,205
Most recent
2026-11-11

Of the 8,503 recalls naming Missouri we have scored against our rubric, 1,339 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 2,205 (26%) are Severe.

These figures cover only the 8,503 recalls whose distribution notice names Missouri specifically. The 73,905 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

68526–68550 of 82408

  • HighCPSC·14037·2013-12-04

    K2 Revo Kick Kickboards Recalled for Handle Detachment Hazard

    K2 Sports is recalling K2 Revo Kick kickboards/scooters because the front assembly can break, causing the handle to detach and posing a fall hazard to riders.

    Product
    K2 Revo Kick kickboards/scooters
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0375-2014·2013-12-04

    Plum Organics Baby Food Recalled for Post-Process Contamination

    Plum Inc is recalling Kale, Apple & Greek Yogurt baby food pouches due to a manufacturing defect causing post-process contamination.

    Product
    Plum Organics Kale, Apple & Greek Yogurt Organics Baby Food- 3.5 oz. Pouch Flexible pouch with Resealable spout. Packaged for individual sale in 6 count cartons and in 4 count packages. Best By dates ranging from 08/05/14 to 12/08/14 and the letters AT. DISTRIBUTED…
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0350-2014·2013-12-04

    MRM Recalls Gluten Free 60 vcaps Due to Chloramphenicol Contamination

    Metabolic Response Modifier is recalling Gluten Free 60 vcaps because the product may contain trace amounts of the antibiotic chloramphenicol.

    Product
    Gluten Free 60 vcaps, sku#609492310194. 12 units per shipping carton/case.
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0388-2014·2013-12-04

    Synthes Tensioning Device Recalled Due to Potential Mechanical Failure

    Synthes USA HQ, Inc. is recalling 369 Tensioning Devices because the reaction fork may come loose, preventing the device from applying tension or releasing the wire.

    Product
    Synthes Tensioning Device The Synthes Osteogenesis System, MR Conditional is intended for fracture fixation (open and closed), pseudoarthrosis or non-unions of long bones, limb lengthening by epiphyseal or metaphyseal distraction, correction of bony or soft tissue…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0418-2014·2013-12-04

    DePuy Recalls HP M.B.T. Keel Punch Knee Instruments Due to Fracture Risk

    DePuy Orthopaedics is voluntarily recalling HP M.B.T. Keel Punch Knee Instruments because tabs on the connection end may fracture and remain in the patient.

    Product
    SIGMA¿ LCS¿ HIGH PERFORMANCE" MBT PUNCH CEMENTED Size 1-1.5 HP M.B.T. Keel Punch Knee Instrument is used to prepare the proximal tibial canal geometry to accept the final or definitive tibial tray used during total knee arthroplasty.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0419-2014·2013-12-04

    DePuy Recalls Knee Instruments Due to Potential Tab Fracture

    DePuy Orthopaedics is voluntarily recalling HP M.B.T. Keel Punch Knee Instruments because tabs may fracture and remain in patients.

    Product
    SIGMA¿ LCS¿ HIGH PERFORMANCE" MBT PUNCH CEMENTED Size 2-3 HP M.B.T. Keel Punch Knee Instrument is used to prepare the proximal tibial canal geometry to accept the final or definitive tibial tray used during total knee arthroplasty.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0377-2014·2013-12-04

    Plum Inc Recalls Parsnip, Blueberry & Buckwheat Pouches for Contamination

    Plum Inc is recalling Parsnip, Blueberry & Buckwheat pouches due to a manufacturing defect that led to post-process contamination.

    Product
    Parsnip, Blueberry & Buckwheat Flexible pouch with Resealable spout. Packaged for individual sale in 6 count cartons and in 4 count packages. Best By dates ranging from 08/05/14 to 12/08/14 and the letters AT. DISTRIBUTED BY: NEST COLLECTIVE, INC. EMERYVILLE, CA…
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·13V608000·2013-12-04

    Triumph Recalls 2013 Trophy SE Motorcycles Due to Center Stand Defect

    Triumph is recalling 416 model year 2013 Trophy SE motorcycles because the left-hand center stand mount may fracture, potentially causing the bike to fall over while parked.

    Product
    TRIUMPH — TRIUMPH TROPHY SE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0405-2014·2013-12-04

    Synthes Implant Holder Recalled Due to Breakage During Orthopedic Surgery

    Synthes USA HQ, Inc. is recalling 548 Synfix (TM)-LR Implant Holders because they may break at the interface between the implant and the holder.

    Product
    Synthes Implant Holder for Synfix (TM)-LR the Synthes Implant Holder for Synfix (TM)-LR is a non-powered hand-held device intended for medical purposes to manipulate tissue, or for use with other devices in orthopedic surgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0391-2014·2013-12-04

    Synthes Matrix Coronal Bender Recall Due to Tip Breakage

    Synthes USA is recalling 209 Matrix 5.5mm Coronal Benders because tips broke during use. The devices are used for spinal stabilization.

    Product
    Synthes Matrix 5.5.mm Left and Right Coronal Bender Product Usage: The Matrix 5.5.mm Left and Right Coronal Bender are used together to bend the 5.5 Matrix Rods in the coronal plane, and is intended for stabilization of the thoracic, lumbar, sacral, and/or iliac spine…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0412-2014·2013-12-04

    DePuy Recalls HP M.B.T. Keel Punch Knee Instruments Due to Fracture Risk

    DePuy Orthopaedics is voluntarily recalling HP M.B.T. Keel Punch Knee Instruments because tabs on the connection end may fracture and remain in the patient.

    Product
    SIGMA¿ LCS¿ HIGH PERFORMANCE" MBT KEEL PUNCH CEMENTED SIZE 1-1.5 HP M.B.T. Keel Punch Knee Instrument is used to prepare the proximal tibial canal geometry to accept the final or definitive tibial tray used during total knee arthroplasty.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0374-2014·2013-12-04

    Siemens Fluoroscopic X-Ray Systems Recalled for Radiation Malfunction

    Siemens is recalling specific fluoroscopic x-ray systems due to a software defect that may cause radiation to continue longer than required, resulting in overexposed images.

    Product
    (Siemens Rad Fluoro Uro Systems) Ysio, Luminos Agile, Luminos dRF, and Uroskop Omnia systems with software version VC10 Image intensified fluoroscopic x-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0361-2014·2013-12-04

    Plum Organics Baby Food Recalled for Post-Process Contamination Risk

    Plum Inc is recalling specific lots of Plum Organics Raspberry, Spinach & Greek Yogurt Organic Baby Food due to a manufacturing defect that could lead to post-process contamination.

    Product
    Plum Organics Raspberry, Spinach & Greek Yogurt Organic Baby Food, 4 oz. pouch. Flexible pouch with Resealable spout. Packaged for individual sale in 6 count cartons and in 4 count packages. Best By dates ranging from 08/05/14 to 12/08/14 and the letters AT.…
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0420-2014·2013-12-04

    DePuy Recalls HP M.B.T. Keel Punch Knee Instruments Due to Fracture Risk

    DePuy Orthopaedics is voluntarily recalling HP M.B.T. Keel Punch Knee Instruments because tabs on the connection end may fracture and remain in the patient.

    Product
    SIGMA¿ LCS¿ HIGH PERFORMANCE" MBT PUNCH CEMENTED Size 4-7 HP M.B.T. Keel Punch Knee Instrument is used to prepare the proximal tibial canal geometry to accept the final or definitive tibial tray used during total knee arthroplasty.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0363-2014·2013-12-04

    Plum Organics Baby Food Recalled for Manufacturing Defect

    Plum Inc is recalling Spinach, Peas & Pear Organic Baby Food due to a manufacturing defect that led to post-process contamination.

    Product
    Plum Organics Spinach, Peas & Pear Organic Baby Food, 4 oz. pouch.. Flexible pouch with Resealable spout. Packaged for individual sale in 6 count cartons and in 4 count packages. Best By dates ranging from 08/05/14 to 12/08/14 and the letters AT. DISTRIBUTED BY: NEST…
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0381-2014·2013-12-04

    Biomet Recalls Oversized Security Blades for Carpal Tunnel Surgery

    Biomet, Inc. is recalling 1,130 Security Blades for carpal tunnel surgery because they were manufactured oversized and may be difficult to advance through the mating clip.

    Product
    REF 200068 Security (TM) Enclosed Carpal Tunnel System Blade ( Single) ABS /Stainless Steel Sterile Device, Single Use Only. Designed to release the transverse carpal ligament.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0396-2014·2013-12-04

    Synthes Titanium Spinal Locking Caps Recalled for Post-Operative Loosening

    Synthes USA is recalling 745 Titanium Minimally Invasive Reduction Screw System Locking Caps due to a risk of post-operative loosening if the construct is mis-aligned during final tightening.

    Product
    Synthes Titanium Minimally Invasive Reduction Screw System Locking Cap, Part Number 04.631.502 Non-cervical spinal fixation devices intended for posterior pedicle screw fixation, posterior hook fixation, or anterolateral fixation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0408-2014·2013-12-04

    Synthes Slipped Capital Femoral Epiphysis System Recalled for Drill Bit Breakage

    Synthes USA is recalling 166 units of the Slipped Capital Femoral Epiphysis System because guide wires may stick and drill bits may break during surgery.

    Product
    Slipped Capital Femoral Epiphysis System Product Usage: Intended for fracture fixation of large bones and large bone fragments and for slipped capital femoral epiphysis, pediatric femoral neck fractures, intercondylar femur fractures and sacroiliac joint disruptions.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·14038·2013-12-04

    SRAM Recalls Bicycle Derailleurs Due to Fall Hazard

    SRAM is recalling specific RED WiFLi rear derailleurs because a pivot pin can loosen, causing the derailleur to jam and posing a fall hazard.

    Product
    Bicycle chain derailleurs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0422-2014·2013-12-04

    DePuy Recalls HP M.B.T. Keel Punch Knee Instruments Due to Fracture Risk

    DePuy Orthopaedics is voluntarily recalling HP M.B.T. Keel Punch Knee Instruments because tabs on the connection end may fracture and remain in the patient.

    Product
    SIGMA¿ LCS¿ HIGH PERFORMANCE" MBT PUNCH NONCEMENTED Size 2-3 HP M.B.T. Keel Punch Knee Instrument is used to prepare the proximal tibial canal geometry to accept the final or definitive tibial tray used during total knee arthroplasty.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0357-2014·2013-12-04

    Plum Organics Yogurt Mish Mash Recalled for Contamination

    Plum Inc is recalling Plum Organics Tots Purple Roots and Fruits Yogurt Mish Mash due to a manufacturing defect that led to post-process contamination.

    Product
    Plum Organics Tots Purple Roots and Fruits Yogurt Mish Mash; 3.17 oz. Pouch; Also 12.69 oz. box. Flexible pouch with Resealable spout. Packaged for individual sale in 6 count cartons and in 4 count packages. Best By dates ranging from 08/05/14 to 12/08/14 and the letters…
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0380-2014·2013-12-04

    Plum Inc Recalls Kale, Apple & Greekstyle Yogurt Pouches

    Plum Inc is recalling Kale, Apple & Greekstyle Yogurt pouches due to a manufacturing defect that led to post-process contamination.

    Product
    Kale, Apple & Greekstyle Yogurt Flexible pouch with Resealable spout. Packaged for individual sale in 6 count cartons and in 4 count packages. Best By dates ranging from 08/05/14 to 12/08/14 and the letters AT. DISTRIBUTED BY: NEST COLLECTIVE, INC. EMERYVILLE, CA 94608…
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-0401-2014·2013-12-04

    Kraft and Polly-O String Cheese Recalled for Potential Spoilage

    Kraft Foods Group is recalling specific varieties of Kraft and Polly-O String Cheese and String Cheese Twist products because they may spoil before their expiration dates, causing discoloration.

    Product
    Low-Moisture Part-Skim Mozzarella String Cheese, sold under Kraft brand or Polly-O brand and packaged with either 12, 16, 24, or 48 pieces of mozzarella cheese individually wrapped in plastic and sold in a plastic bag with a net weight respectively of 12 oz. (340g), 16 oz. (1…
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-0404-2014·2013-12-04

    Kraft and Polly-O String Cheese Recalled for Potential Spoilage

    Kraft Foods Group is recalling certain Kraft and Polly-O String Cheese products that may spoil before their expiration dates, causing discoloration.

    Product
    Low-Moisture Part-Skim Mozzarella String Cheese With Jalapeno Peppers, sold under Kraft brand or Polly-O brand and packaged with 12 pieces of mozzarella cheese with jalapeno peppers individually wrapped in plastic and sold in a plastic bag with a net weight of 10 oz. (283g).
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0410-2014·2013-12-04

    Synthes Recalls Vertebroplasty Needle Kits Due to Expiration Date Inconsistencies

    Synthes USA is recalling 40 Vertebroplasty Needle Kits because of inconsistent expiration dates on the packaging.

    Product
    Vertebroplasty Needle Kit 10g Diamond Tip Intended to be used to inject PMMA cement into vertebral bodies during Vertebroplasty procedure.
    Category
    Medical Device
    Distribution
    Distributed nationwide