The Recall Desk

State

Louisiana product recalls

72,919 recalls have nationwide distribution and so reach Louisiana. 6,922 additional recalls listed Louisiana specifically in their distribution scope.

What the numbers show

Total
6,922
Critical
1,094
Severe
1,483
Most recent
2026-09-09

Of the 6,922 recalls naming Louisiana we have scored against our rubric, 1,094 (16%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,483 (21%) are Severe.

These figures cover only the 6,922 recalls whose distribution notice names Louisiana specifically. The 72,919 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

2601–2625 of 79841

  • HighFDA (Devices)·Z-1741-2026·2026-04-08

    MiniMed 780G insulin pump delivery varies with pump height changes

    Medtronic is recalling MiniMed 780G insulin pumps because raising or lowering the pump relative to the infusion site can cause unintended over- or under-delivery of insulin.

    Product
    MiniMed 780G Insulin Pump (MMT-1884, MMT-1885, MMT-1886, MMT-1894, MMT-1895, MMT-1896)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1691-2026·2026-04-08

    Medline ENFit G-tube connector kits may leak from dimensional defect

    Medline is recalling kits containing ENFit G-tube connectors because the connectors were not made to required dimensional specifications and may not form a proper seal.

    Product
    Medline Kits containing ENFIT G-TUBE CONNECTOR 1. SKU DYKM2720 G/J TUBE CARE KIT 2. SKU ENFITDISCKIT ENFIT DISCHARGE KIT
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0410-2026·2026-04-08

    Quality Choice moisturizing relief eye drops recalled over sterility assurance

    Quality Choice Moisturizing Relief Eye Drops, containing dextran 70, polyethylene glycol 400, povidone and tetrahydrozoline hydrochloride, are being recalled for lack of assurance of sterility.

    Product
    QUALITY CHOICE MOISTURIZING RELIEF EYE DROPS — QUALITY CHOICE MOISTURIZING RELIEF EYE DROPS (DEXTRAN 70, POLYETHYLENE GLYCOL 400, POVIDONE, TETRAHYDROZOLINE HCL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1655-2026·2026-04-08

    Paradise renal denervation catheter distributed despite being marked for scrapping

    Recor Medical is recalling one lot of the Paradise Ultrasound Renal Denervation System Catheter because a nonconforming product that should have been scrapped was distributed instead.

    Product
    Brand Name: Paradise¿ Ultrasound Renal Denervation System Product Name: Paradise ¿ Catheter Model/Catalog Number: PRDS-068-02 Product Description: Common name: Ablation catheter renal denervation
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0638-2026·2026-04-08

    Dumpling and Loaded Dumpling Vegetable products recalled for glass contamination

    JFE Franchising Inc is recalling Dumpling Vegetable and Loaded Dumpling Vegetable products due to the presence of glass fragments. The products were distributed across multiple U.S. states.

    Product
    " Dumpling Vegetable 4.5 oz 011110658067 " Loaded Dumpling Vegetable 5.7 oz 011110696953
    Category
    Food
    Distribution
    37 states
  • HighFDA (Devices)·Z-1683-2026·2026-04-08

    CPX 4 medium height tissue expander infusion needles may be blunt

    Mentor is recalling CPX 4 US Breast Tissue Expanders with Suture Tabs in the smooth medium height range because the infusion sets may contain a dull or blunt needle tip.

    Product
    CPX 4 US Breast Tissue Expanders with Suture Tabs Reference Numbers: SCPX-107MH, SCPX-117MH,SCPX-127MH, SCPX-135MH, SCPX-146MH, SCPX-156MH Smooth Medium Height Tissue Expander, 275cc, 350cc, 450cc, 550cc, 650cc, 800cc
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0413-2026·2026-04-08

    GoodSense original formula eye drops recalled over sterility assurance

    GoodSense Eye Drops Original Formula, containing tetrahydrozoline hydrochloride, are being recalled for lack of assurance of sterility.

    Product
    GOODSENSE EYE DROPS ORIGINAL FORMULA — GOODSENSE EYE DROPS ORIGINAL FORMULA (TETRAHYDROZOLINE HCL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1684-2026·2026-04-08

    CPX 4 tall height tissue expander infusion needles may be blunt

    Mentor is recalling CPX 4 US Breast Tissue Expanders with Suture Tabs in the smooth tall height range because the infusion sets may contain a dull or blunt needle tip.

    Product
    CPX 4 US Breast Tissue Expanders with Suture Tabs Reference Numbers: SCPX-113TH, SCPX-123TH, SCPX-140TH, SCPX-146TH Smooth Tall Height Tissue Expander, 350cc, 450cc, 650cc, 750cc
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1690-2026·2026-04-08

    Medline ENFit G-tube connectors may leak from dimensional specification failure

    Medline is recalling ENFit G-tube connectors because they were not manufactured to required dimensional specifications and may not form a proper seal with ENFit-style devices.

    Product
    ENFIT G-TUBE CONNECTOR, MEDLINE Item No. ENFIT1010GC
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0409-2026·2026-04-08

    Quality Choice irritation relief eye drops recalled over sterility assurance

    Quality Choice Eye Drops Irritation Relief, containing tetrahydrozoline HCl and zinc sulfate, are being recalled for lack of assurance of sterility. 182,424 bottles are affected.

    Product
    QUALITY CHOICE EYE DROPS IRRITATION RELIEF — QUALITY CHOICE EYE DROPS IRRITATION RELIEF (TETRAHYDROZOLINE HCL, ZINC SULFATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1686-2026·2026-04-08

    Artoura breast tissue expander infusion set needles may be blunt

    Mentor Texas is recalling Artoura Breast Tissue Expanders because the infusion sets may contain a dull or blunt needle tip that may be difficult to advance or may break.

    Product
    Artoura Breast Tissue Expanders Reference Numbers: SDC-100H SDC-110H SDC-120H SDC-130H SDC-135H SDC-140H SDC-150H SDC-155H Smooth High Profile Tissue Expander, 225cc, 300cc, 375cc, 475cc, 500cc, 600cc, 750cc, 850cc
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0639-2026·2026-04-08

    Dumpling Party Tray Products Recalled for Glass Fragments

    JFE Franchising Inc is recalling three dumpling products due to possible glass fragments. Affected products include Dumpling Party Tray (20pcs and 40pcs) Vegetable varieties and Cheetos Flamin Hot Loaded Dumpling Vegetable.

    Product
    " Dumpling Party Tray (20pcs) Vegetable 13 oz 011110661173 " Dumpling Party Tray (40pcs) Vegetable 26 oz 011110661180 " Cheetos Flamin Hot Loaded Dumpling Vegetable 6oz 011110663474
    Category
    Food
    Distribution
    37 states
  • HighFDA (Devices)·Z-1710-2026·2026-04-08

    Medline bronchoscopy kits contain Olympus biopsy valves that shed fragments

    Medline is recalling six bronchoscopy and thoracic kits because they contain recalled Olympus biopsy valves, where rubber fragments may detach from the valve slit during use.

    Product
    Medline kits containing Olympus biopsy valves: 1. BRONCH PROCEDURE KIT, DYKE2091 2. BRONCHSCOPY, DYNJ900898G DYNJ901922I 3. BRONCHSCOPY PACK, DYNJ38313B 4. BRONCHOSCOPY PACK 0120367-LF, DYNJ32750G DYNJ32750I 5. KIT, WR THORACIC, DYNJ911252 6. LARYNGOSCOPY/BRON
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1766-2026·2026-04-08

    Oxoid Microbact Listeria kit may identify the incorrect organism

    Oxoid, part of Thermo Fisher Scientific, is recalling one lot of the Microbact 12L Listeria identification kit because it may identify the incorrect organism.

    Product
    OXOID MICROBACT IDENTIFICATION KITS, Listeria 12L Kit, 20 Tests; Listeria identification sysystem
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1745-2026·2026-04-08

    MiniMed 720G insulin pump delivery varies with pump height changes

    Medtronic is recalling MiniMed 720G insulin pumps because raising or lowering the pump relative to the infusion site can cause unintended over- or under-delivery of insulin.

    Product
    MiniMed 720G Insulin Pump (MMT-1809, MMT-1810, MMT-1859, MMT-1860, MMT-1867)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0415-2026·2026-04-08

    Rugby and Walgreens lubricant eye drops recalled over sterility assurance

    K.C. Pharmaceuticals is recalling Sterile Eye Drops Soothing Tears, sold as Rugby Lubricating Eye Drops and Walgreens Lubricant Eye Drops, for lack of assurance of sterility.

    Product
    STERILE EYE DROPS SOOTHING TEARS (polyethylene glycol 400 0.4% and propylene glycol 0.3%), 0.5 OZ 0.5 fl oz (15 mL) bottles; a) Rugby LUBRICATING EYE DROPS, Distributed by: Rugby Laboratories, Livonia, MI 48152, NDC 0536-1219-94; b) Walgreens, Lubricant Eye Drops, DISTRIBUTED BY
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1674-2026·2026-04-08

    Philips Azurion 3 M15 X-ray may not start from foot switch

    Philips is recalling the Azurion 3 M15 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Azurion 3 M15; System Code: (1)722064, (2)722222, (3)722230, (4)722280 (OUS Only);
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0414-2026·2026-04-08

    GNP redness and dry eye relief drops recalled over sterility assurance

    GNP Eye Drops Redness and Dry Eye Relief, containing glycerin and naphazoline hydrochloride, are being recalled for lack of assurance of sterility.

    Product
    LEADER EYE DROPS REDNESS RELIEF — LEADER EYE DROPS REDNESS RELIEF (GLYCERIN, NAPHAZOLINE HYDROCHLORIDE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1672-2026·2026-04-08

    Philips Allura Xper FD20/15 OR Table X-ray may not start

    Philips is recalling the Allura Xper FD20/15 OR Table because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD20/15 OR Table; System Code: 722059;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1701-2026·2026-04-08

    da Vinci permanent cautery hook recalled over frayed pitch cables

    Intuitive Surgical is recalling da Vinci S and Si Permanent Cautery Hook Instruments following increased complaints regarding frayed or broken pitch cables on reusable surgical instruments.

    Product
    Brand Name: da Vinci S, Si Permanent Cautery Hook Instrument Product Name: da Vinci S, Si Permanent Cautery Hook Instrument Model/Catalog Number: 420183 Software Version: NA Product Description: EndoWrist Instruments or da Vinci S/Si Reusable instruments, including blunt and
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateNHTSA·26V221000·2026-04-08

    Forest River Recalls 2026 Travel Trailers Due to Incorrect Weight Labeling

    Forest River is recalling 2026 Westbrook and Avenger travel trailers because the Federal Placard label may list an incorrect dry weight, potentially leading to vehicle overloading.

    Product
    FOREST RIVER — FOREST RIVER AVENGER, WESTBROOK
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • LowFDA (Food)·H-0636-2026·2026-04-08

    Popping Boba Ready-to-Drink Mango Passion Fruit Green Tea Recall

    Pocas International Corp. is recalling Popping Boba RTD Mango Passion Fruit Green Tea due to a packaging integrity issue that may compromise product quality.

    Product
    POPPING BOBA RTD MANGO PASSION FRUIT GREEN TEA 12 X 13.8OZ
    Category
    Food
    Distribution
    8 states
  • LowFDA (Food)·H-0633-2026·2026-04-08

    Popping Boba RTD Peach Oolong Tea recalled for packaging integrity

    Pocas International Corp. is recalling Popping Boba RTD Peach Oolong Tea due to a packaging integrity issue that may compromise product quality.

    Product
    POPPING BOBA RTD PEACH OOLONG TEA 12 X 13.8OZ
    Category
    Food
    Distribution
    8 states