The Recall Desk

State

Kansas product recalls

73,809 recalls have nationwide distribution and so reach Kansas. 5,822 additional recalls listed Kansas specifically in their distribution scope.

What the numbers show

Total
5,822
Critical
1,053
Severe
1,486
Most recent
2026-11-04

Of the 5,822 recalls naming Kansas we have scored against our rubric, 1,053 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,486 (26%) are Severe.

These figures cover only the 5,822 recalls whose distribution notice names Kansas specifically. The 73,809 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

43076–43100 of 79631

  • SevereFDA (Drugs)·D-0381-2018·2018-02-21

    Sage Products Recalls Toothette Oral Care Suction Swab System

    Sage Products Inc. is recalling Toothette Oral Care Suction Swab Systems due to cross-contamination with non-pharmaceutical products during manufacturing.

    Product
    Toothette Oral Care Suction Swab System with Perox-A-Mint Solution, Contains 6 Packages of 2 Suction Swabs with sodium, bicarbonate and a .25 fl oz/7ml pouch of Perox-A-Mint solution, 2 Packages of 1 Suction Toothbrush with sodium bicarbonate and a .25 fl oz/7ml pouch of…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0364-2018·2018-02-21

    Sage Products Recalls Toothette Oral Care Systems Due to Cross-Contamination

    Sage Products is recalling Toothette Oral Care Single Use Systems because they were manufactured on equipment shared with non-pharmaceutical products.

    Product
    Toothette Oral Care Single Use System With Perox-A-Mint solution. Contains: 2 Toothette Plus swabs with sodium bicarbonate, .25 fl oz/7ml tube of Perox-A-Mint solution. Sage Products, Inc., 3909 Three Oaks Road, Cary, IL 60013. Product Code 6012 UPC (01)00618029800077
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0368-2018·2018-02-21

    Sage Products Recalls Toothette Oral Care Suction Swab System

    Sage Products Inc. is recalling the Toothette Oral Care Suction Swab System due to cross-contamination with non-pharmaceutical products during manufacturing.

    Product
    Toothette Oral Care Suction Swab System With Antiseptic Oral Rinse and Mouth Moisturizer. Contains 2 Suction Swabs with sodium bicarbonate 0.25 fl oz/7ml Antiseptic Oral Rinse 0.7 oz/2g Mouth Moisturizer, Sage Products, Inc., 3909 Three Oaks Roarald, Cary, IL 60013. Product Code…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0344-2018·2018-02-21

    FDA Recalls Unapproved Limbrel Flavocoxid Capsules Nationwide

    Primus Pharmaceuticals is recalling 7,826 bottles of Limbrel (flavocoxid 250 mg) capsules because the product was marketed without an approved NDA or ANDA.

    Product
    Limbrel (flavocoxid 250 mg) capsules, 60-count bottle, Rx only, Manufactured for: Primus Pharmaceuticals, Inc., Scottsdale, AZ 85253; Manufactured by: Cornerstone Research and Development, Ogden, UT 84404, NDC 68040-601-16.
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0365-2018·2018-02-21

    Sage Products Recalls Toothette Oral Care Systems Due to Cross-Contamination

    Sage Products Inc. is recalling Toothette Oral Care Single Use Systems because they were manufactured on equipment shared with non-pharmaceutical products, posing a cross-contamination risk.

    Product
    Toothette Oral Care Single Use System with Perox-A-Mint solution and Mouth Moisturizer. Contains 2 Toothette Plus Swabs with sodium bicarbonate, .25 fl oz/7ml Perox-A-Mint solution and .07 oz/2g Mouth Moisturizer, Sage Products, Inc., 3909 Three Oaks Road, Cary, IL 60013.…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0377-2018·2018-02-21

    Sage Products Recalls Q CARE Oral Cleansing Systems Due to Cross-Contamination

    Sage Products Inc. is recalling Q CARE q4 Oral Cleansing & Suctioning Systems because oral care solutions were manufactured on equipment shared with non-pharmaceutical products.

    Product
    Q CARE q4 Oral Cleansing & Suctioning System, Contains 1 Covered Yankauer and Y-Connector, 2 Suction Toothbrush packages with Antiplaque solution, 4 Suction Oral Swab packages with Perox-A-Mint solution, 2 Oropharyngeal Suction Catheter packages, Sage Products, Inc., 3909…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0378-2018·2018-02-21

    Sage Products Recalls Oral Cleaning Systems Due to Cross-Contamination

    Sage Products Inc. is recalling 852 cases of Oral Cleaning and Suctioning System q2 because oral care solutions were manufactured on equipment shared with non-pharmaceutical products.

    Product
    Oral Cleaning and Suctioning System q2. Contains 1 Covered Yankauer, 2 Untreated Suction Toothbrush packages with Antiplaque solution, 4 Suction Oral Swab packages with Perox-A-Mint- solution, 6 Suction Oral Swab packages with Alcohol-Free Mouthwash solution, 2 Oropharyngeal…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0393-2018·2018-02-21

    Sage Q.Care Oral System Recalled for Cross-Contamination Risk

    Sage Products Inc. is recalling Q.Care Oral Cleansing & Suctioning Systems because oral care solutions were manufactured on equipment shared with non-pharmaceutical products.

    Product
    Q.Care Petite Size Oral Cleansing & Suctioning System. Contains 1 Covered Yankauer, Suction Handle and Y-Connector, 2 Petit Size Suction Toothbrush packages with Antiseptic Oral Rinse, 4 Petit Size Untreated Suction Oral Swab packages with Antiseptic Oral Rinse, 2 8 French…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0405-2018·2018-02-21

    Sage Q.Care Oral Cleansing System Recalled for Cross-Contamination Risk

    Sage Products Inc. is recalling Q.Care Oral Cleansing & Suctioning Systems because oral care solutions were manufactured on equipment shared with non-pharmaceutical products.

    Product
    Q.Care Oral Cleansing & Suctioning System Suction Toothbrush Compatible with Chlorhexidine Gluconate (CHG) Oral Rinse q4. Contains 1 Covered Yankauer and Y-Connector, 1 Untreated Suction Toothbrush packages, 2 Single dose bottles of 0.12% CHG Oral Rinse, 4 Suction Oral Swab…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0356-2018·2018-02-21

    Sage Products Recalls Oral Cleansing Systems Due to Cross-Contamination Risk

    Sage Products Inc. is recalling 2,199 cases of Oral Cleansing & Suctioning System q4 because oral care solutions were manufactured on equipment shared with non-pharmaceutical products.

    Product
    Oral Cleansing & Suctioning System q4. Contains 1 Covered Yankauer, 2 Untreated Suctino Toothbrush packages with Antiplaque solution, 4)Suction Oral Swab packages with Perox-A-Mint solution, 2 Oropharyngeal Suction Catheter packages, Sage Products, Inc., 3909 Three Oaks Road…
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0596-2018·2018-02-21

    Zimmer Biomet Recalls Persona Partial Knee System Impactor Pads

    Zimmer Biomet is recalling 1,275 Persona Partial Knee System instruments because the impactor pad may fracture during use.

    Product
    Persona Partial Knee System Product Usage: The Persona Partial Knee System instruments are used by a surgeon to facilitate the implantation of PPK implantable components into the medical knee compartment during unicondylar knee replacement.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0568-2018·2018-02-21

    B. Braun Recalls Perifix Anesthesia Trays Due to Foreign Matter

    B. Braun Medical is recalling 700 Perifix Single Dose Epidural Anesthesia Trays because they contain loose polypropylene foreign matter above release specifications.

    Product
    Perifix Single Dose Epidural Anesthesia Tray. Product Catalog Number: 332252. Local anesthesia of the skin prior to insertion of the regional anesthesia needle.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0348-2018·2018-02-21

    Sage Products Recalls Q.Care Oral Cleansing Kits Due to Cross-Contamination

    Sage Products is recalling 1,182 Q.Care Oral Cleansing & Suctioning System kits because oral care solutions were manufactured on equipment shared with non-pharmaceutical products.

    Product
    Q.Care, Oral Cleansing & Suctioning System q4. Contains: 1 Covered Yankauer and Y-Connector, 2 Suction Toothbrush packages and Antiplaque solution, 4 Suction Oral Swab packages with Perox-A-Mint solution. Manufactured by: Sage Products, LLC., 3909 Three Oaks Road, Cary, IL…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0626-2018·2018-02-21

    Zimmer Biomet Recalls G7 Dual Mobility Hip Liners Due to Labeling Error

    Zimmer Biomet is recalling 8 units of G7 Dual Mobility Liners because they are labeled as 44mm but may physically be 42mm liners.

    Product
    G7 DUAL MOBILITY LINER 44MM F Product Usage: Intended for use in hip arthroplasty cases which involves the removal of the damaged joint and tissues to be replaced with artificial prosthesis. The result of the procedure is to relieve pain and restore a sense of normal…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0625-2018·2018-02-21

    Roche Recalls Accu-Chek Connect App Due to Bolus Advisor Software Bug

    Roche Diabetes Care is recalling the Accu-Chek Connect app because a software bug may cause incorrect unit changes, risking inaccurate blood glucose data or carbohydrate input.

    Product
    Accu-Chek Connect Diabetes Management App, Catalog number 07562462001 / GTIN number 00365702700000 & Catalog number 07250452001 / GTIN number 00365702700017
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0591-2018·2018-02-21

    Aesculap Vega Knee Trial Plateau Recalled for Incorrect Labeling

    Aesculap is recalling 13 units of the NS357R Vega PS Tibia Trial/Preparation Plateau size T4 due to incorrect labeling. Using the wrong size could lead to implantation errors, ligament injury, pain, or revision surgery.

    Product
    NS357R Vega PS Tibia Trial/Preparation Plateau size T4 (Component of the Vega Knee System Set #ST0468) The affected part is provided in the Vega Knee System Set #ST0468. The Vega Knee System is used for reconstruction of the diseased knee joint.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0599-2018·2018-02-21

    3M Bair Hugger Underbody Blanket Recall for Airflow Occlusion Risk

    3M is recalling Bair Hugger Normothermia System blankets due to a design change that may cause unintended airflow occlusion and limited inflation.

    Product
    3M Bair Hugger(M) Normothermia System, Sterile Full Access Underbody, Model 63700 The 3M Bair Hugger Temperature Management System is intended to prevent and treat hypothermia. In addition, the temperature management system can be used to provide patient thermal comfort when…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighCPSC·18104·2018-02-21

    Yayi Outdoor Gas Fire Pit Tables Recalled for Burn Hazard

    Yayi is recalling Hampton Bay outdoor gas fire pit tables sold at Home Depot because the bowl base lacks a heat shield, posing a burn risk.

    Product
    Outdoor Gas Fire Pit Table Patio Heaters
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0628-2018·2018-02-21

    Zimmer Biomet Recalls AGC 2000 LP Patella Knee Implants

    Zimmer Biomet is recalling 11 AGC 2000 LP Patella knee implants because they were over-molded, causing the outside diameter to not match the required specifications.

    Product
    AGC 2000 LP Patella, labeled as AGC Porous Patellar Med, Model Number 150804. Product Usage: For use in Total Knee Arthroplasty.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0627-2018·2018-02-21

    Zimmer Biomet Recalls AGC 2000 LP Patella Knee Implant Devices

    Zimmer Biomet is recalling 28 AGC 2000 LP Patella knee implants because they were over-molded, leaving the outside diameter nonconforming to the print dimension.

    Product
    AGC 2000 LP Patella, labeled as AGC Porous Patellar SM, Model Number 150802. Product Usage: For use in Total Knee Arthroplasty.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0598-2018·2018-02-21

    3M Bair Hugger Warming Blanket Recall for Airflow Occlusion Risk

    3M is recalling Bair Hugger warming blankets because a design change may cause airflow blockage, leading to limited inflation during use.

    Product
    3M Bair Hugger(M) Normothermia System, Full Access Underbody Warming Blanket, REF 63500 The 3M Bair Hugger Temperature Management System is intended to prevent and treat hypothermia. In addition, the temperature management system can be used to provide patient thermal…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0629-2018·2018-02-21

    Hemotherm Dual Reservoir Cooler/Heater System Recall for Updated Cleaning Instructions

    Cincinnati Sub-Zero is recalling 1,355 Hemotherm units to provide updated instructions for cleaning and disinfection to address NTM infection risks.

    Product
    Hemotherm¿ Dual Reservoir Cooler/Heater System Models 400CE and 400MR Product Usage: A dual reservoir, water re-circulating device that supplies temperature controlled water to a heat exchanger. The device, in conjunction with a heat exchanger, is used to warm or cool the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0396-2018·2018-02-21

    Sage Products Recalls Q.CARE Oral Cleansing System Due to Cross-Contamination

    Sage Products Inc is recalling Q.CARE Oral Cleansing & Suctioning Systems because oral care solutions were manufactured on equipment shared with non-pharmaceutical products.

    Product
    Q.CARE Oral Cleansing & Suctioning System q4. Contains 1 Covered Yankauer, Suction Handle and Y-Connector, 2 Toothbrush packages with Antiplaque solution. 4 Suction Oral Swab packages with Perox-A-Mint solution. 2 Oropharyngeal Suction Catheter packages, Sage Products, Inc.…
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0351-2018·2018-02-21

    Sage QCare Oral Cleansing System Recalled for Cross-Contamination Risk

    Sage Products Inc. is recalling QCare Oral Cleansing and Suctioning Systems with Corinz due to cross-contamination with non-pharmaceutical products during manufacturing.

    Product
    QCare Oral Cleansing and Suctioning System with Corinz. Includes: Two (2) Suction Toothbrush packages with 0.25fl.oz/7mL Corinz Antiseptic Cleansing and Moisturizing Oral Rinse and Four (4) Suction Oral Swab packages with 0.25 fl.oz/7mL Corinze Antiseptic Cleansing and…
    Category
    Drug
    Distribution
    Distributed nationwide