The Recall Desk

State

Idaho product recalls

73,092 recalls have nationwide distribution and so reach Idaho. 3,520 additional recalls listed Idaho specifically in their distribution scope.

What the numbers show

Total
3,520
Critical
364
Severe
1,025
Most recent
2026-09-23

Of the 3,520 recalls naming Idaho we have scored against our rubric, 364 (10%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,025 (29%) are Severe.

These figures cover only the 3,520 recalls whose distribution notice names Idaho specifically. The 73,092 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

7901–7925 of 76612

  • SevereFDA (Devices)·Z-1117-2025·2025-02-19

    Wheelchair Power Assist Speed Control Dial Recalled for Loss of Control Risk

    Max Mobility Smart Drive MX2+ SpeedControl Dial wheelchairs are being recalled due to faulty circuit boards that may cause loss of device control, potentially resulting in injury to users.

    Product
    Max Mobility/Permobil Smart Drive MX2+ SpeedControl Dial Ref: MX2-3DCK use in conjunction with the SmartDrive MX2+ Wheelchair Power Assist component.
    Category
    Medical Device
    Distribution
    52 states
  • SevereFDA (Devices)·Z-1071-2025·2025-02-19

    Olympus Guide Sheath Kits recalled for potential radiopaque tip detachment

    Olympus Single Use Guide Sheath Kits (models K-201 through K-204) are recalled because the radiopaque tip of the guide sheath may detach and fall into the patient during respiratory procedures.

    Product
    Olympus Single Use Guide Sheath Kits with the following product descriptions and model numbers: 1. Single Use Guide Sheath Kit K-201 2.0MM Channel Set: Guide Sheath, Biopsy Forceps, Cytology Brush; Model Number: K-201 2. Single Use Guide Sheath Kit K-202 2.0MM Channel Set:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0550-2025·2025-02-19

    Shirakiku Curvee Puffs Corn Snack Recalled for Undeclared Milk Allergen

    Wismettac Asian Foods is recalling Shirakiku brand Curvee Puffs Corn Puff Snacks due to undeclared milk. The product poses a serious risk to consumers with milk allergies. All lots distributed nationwide are affected.

    Product
    Front Panel: Shirakiku brand, CURVEE PUFFS CORN PUFF SNACK, Corn Potage Flavor, NET WT 2.46 oz (70 g); Rear panel:Best Before YYYY.MM.DD; Nutritional Facts: 2.5 servings per container; Distributed by Wismettac Asian Foods, Inc.; 13409 Orden Drive, Santa Fe Spring, CA 90670; Produ
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1116-2025·2025-02-19

    Wheelchair Speed Control Remote Recalled Due to Loss-of-Control Risk

    The Smart Drive MX2+ SpeedControl Dial remote is being recalled due to a faulty circuit board that could cause loss of control of the wheelchair power assist, potentially resulting in injury.

    Product
    Max Mobility/Permobil Smart Drive MX2+ SpeedControl Dial Ref: MX2-3DC use in conjunction with the SmartDrive MX2+ Wheelchair Power Assist component.
    Category
    Medical Device
    Distribution
    52 states
  • SevereFDA (Food)·F-0548-2025·2025-02-19

    Shirakiku Curvee Puffs Corn Puff Snack Recalled for Undeclared Milk Allergen

    Wismettac Asian Foods is recalling Shirakiku brand Curvee Puffs Corn Puff Snack because the product contains undeclared milk allergen. The affected product was distributed nationwide to approximately 471 consignees.

    Product
    Front Panel: Shirakiku brand, CURVEE PUFFS CORN PUFF SNACK, Curry Flavor, NET WT 2.46 oz (70 g); Rear panel:Best Before YYYY.MM.DD; Nutritional Facts: 2.5 servings per container; Distributed by Wismettac Asian Foods, Inc.; 13409 Orden Drive, Santa Fe Spring, CA 90670; Product of
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-0549-2025·2025-02-19

    Shirakiku Curvee Puffs Corn Puff Snack Recalled for Undeclared Milk Allergen

    Wismettac Asian Foods, Inc. is recalling Shirakiku brand Curvee Puffs Corn Puff Snack due to undeclared milk on the label. Consumers with dairy allergies should not consume this product.

    Product
    Front Panel: Shirakiku brand, CURVEE PUFFS CORN PUFF SNACK, Sea Salt & Umami Flavor, NET WT 2.46 oz (70 g); Rear panel:Best Before YYYY.MM.DD; Nutritional Facts: 2.5 servings per container; Distributed by Wismettac Asian Foods, Inc.; 13409 Orden Drive, Santa Fe Spring, CA 90670;
    Category
    Food
    Distribution
    Distributed nationwide
  • HighNHTSA·25E012000·2025-02-19

    Nova Bus Recalls Casco Engine Coolant Level Sensors

    Nova Bus is recalling 223 Casco engine coolant level sensors that may send false signals, causing unexpected engine shutdowns and increasing crash risk.

    Product
    ENGINE AND ENGINE COOLING:COOLING SYSTEM recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1136-2025·2025-02-19

    Cardinal Health Presource Surgical Kits Recalled for Potential Endotoxin Contamination

    Cardinal Health is recalling Presource Kits (surgical strips and patties used in ophthalmic procedures) due to potential endotoxin contamination in non-sterile components.

    Product
    Cardinal Health Presource Kits: 1) OPHTHALMOLOGY ENDO DCR XTRS PK, Catalog Number:SEY30EYRVA; 2) OPHTHALMOLOGY ENDO DCR XTRS PK, Catalog Number:SEY30EYRVB 3) OPHTHALMOLOGY ENDO DCR XTRS PK, Catalog Number:SEY30EYRVC 4) OCULAR PLASTIC PACK, Catalog Number:SEY35OP961 5) OCULAR
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1134-2025·2025-02-19

    Cardinal Health Presource Surgical Kits Recalled for Potential Endotoxin Contamination

    Cardinal Health Presource surgical kits containing non-sterile strips and patties may be contaminated with endotoxins, posing potential risk to patients during surgical procedures.

    Product
    Cardinal Health Presource Kits: 1) CHI STD NEURO CRANI OPT 1, Catalog Number:CHIP99NC12; 2) CHI STD NEURO CRANI OPT 1, Catalog Number:CHIP99NC13 3) CHI STD NEURO CRANI OPT 1, Catalog Number:CHIP99NC14 4) CHI STD NEURO CRANI OPT 1, Catalog Number:CHIP99NC15 5) CHI STD NEURO CRANI
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1129-2025·2025-02-19

    Cardinal Health Presource Surgical Kits Recalled for Endotoxin Contamination

    Cardinal Health Presource Kits may contain endotoxin-contaminated non-sterile surgical strips and patties. These kits are used in surgical procedures and have been distributed worldwide including the US, Canada, and Saudi Arabia. Affected facilities should verify lot numbers against the recall list.

    Product
    Cardinal Health Presource Kits: 1) KIT, CAROTID ENDARTERECTOMY, Catalog Number:PVV20110B; 2) KIT, CAROTID ENDARTERECTOMY, Catalog Number:PVV20110D 3) KIT,CAROTID ENDARTERECTOMY, Catalog Number:PVV2CA103 4) KIT,CAROTID ENDARTERECTOMY, Catalog Number:PVV2CA10T 5) KIT,CAROTID E
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1131-2025·2025-02-19

    Cardinal Health Laryngoscopy Packs Recalled for Potential Endotoxin Contamination

    Cardinal Health Presource Kits containing laryngoscopy packs are being recalled due to potential endotoxin contamination in non-sterile surgical strips and patties.

    Product
    Cardinal Health Presource Kits: 1) LARYNGOSCOPY PACK, Catalog Number:SRIET0979N;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1163-2025·2025-02-19

    HPV Diagnostic Control Panel Recall Due to Quality Control Failures

    Microbiologics is recalling a lot of HPV diagnostic control materials due to inadequate quality control during release. The control's HPV 16 L1 concentration is too low, potentially causing test failures and invalid results in clinical laboratories.

    Product
    Microbiologics Multi-Strain Human Papillomavirus (HPV) Control Panel (Inactivated Pellet), REF 8234; in-vitro diagnostic test
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1164-2025·2025-02-19

    Diagnostic HPV Verification Panel Recalled Due to Quality Control Failures

    Microbiologics Inc is recalling HPV verification test panels (REF 8235) due to quality control failures that allowed defective units to be released. The panels may produce invalid test results or fail to detect HPV.

    Product
    Microbiologics Multi-Strain Human Papillomavirus (HPV) Verification Panel (Inactivated Pellet), REF 8235; in-vitro diagnostic test
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1130-2025·2025-02-19

    Cardinal Health Maxillofacial Surgical Kits Recalled for Potential Endotoxin Contamination

    Cardinal Health Presource maxillofacial surgical kits containing non-sterile strips and patties may have endotoxin contamination. 973,785 units distributed in the US, Canada, and Saudi Arabia are affected; users should stop using and contact the manufacturer.

    Product
    Cardinal Health Presource Kits: 1) KIT,MAXILLOFACIAL,PRESBYTERIAN, Catalog Number:PWV2MF104; 2) KIT,MAXILLOFACIAL,PRESBYTERIAN, Catalog Number:PWV2MF105 3) KIT,MAXILLOFACIAL,PRESBYTERIAN, Catalog Number:PWV2MF106 4) KIT,MAXILLOFACIAL,PRESBYTERIAN, Catalog Number:PWV2MF107 5)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0539-2025·2025-02-19

    Mixed Berry Granola Bars Recalled for Possible Metal Contamination

    Riverside Natural Foods is recalling Mixed Berry Granola Bars nationwide (2.4 million cases) because they may contain metal pieces. Affected consumers should not eat the product and should contact the manufacturer for a refund.

    Product
    1. Mixed Berry Granola Bars; 34oz (40 bars) 2. Mixed Berry Granola Bars; 5.1oz (6 bars) 3.
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1170-2025·2025-02-19

    Hologic Sertera-14 Biopsy Device Recalled for Inner Needle Separation Risk

    Hologic is recalling 55,335 Sertera-14 biopsy devices nationwide because the inner needle can separate from the hub, creating a risk of needle dislodgement during use.

    Product
    Brand Name: Sertera Biopsy Device Product Name: Sertera Biopsy Device Model/Catalog Number: Sertera-14 Software Version: N/A Product Description: Instrument, Biopsy Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1135-2025·2025-02-19

    Cardinal Health Presource surgical kits recalled for endotoxin contamination risk

    Cardinal Health is recalling Presource Kits for potential endotoxin contamination in non-sterile surgical strips and patties. These surgical components could pose infection risks if used in procedures.

    Product
    Cardinal Health Presource Kits: 1) CHI STD SPINE OPTION 1, Catalog Number:CHIP99SP11; 2) CHI STD SPINE OPTION 1, Catalog Number:CHIP99SP12 3) CHI STD SPINE OPTION 1, Catalog Number:CHIP99SP13 4) CHI STD SPINE OPTION 1, Catalog Number:CHIP99SP1E 5) CHI STD SPINE OPTION 2, Catalog
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1128-2025·2025-02-19

    Cardinal Health Urology Robotic Packs recalled for potential endotoxin contamination

    Cardinal Health Presource Kits for robotic urology surgery are being recalled due to potential endotoxin contamination in surgical strips and patties. No adverse events have been reported.

    Product
    Cardinal Health Presource Kits: 1) UROLOGY ROBOTIC PACK, Catalog Number:SOT4FRUWFA; 2) UROLOGY ROBOTIC PACK, Catalog Number:SOT4FRUWFB; 3) UROLOGY ROBOTIC PACK, Catalog Number:SOT4FRUWFC
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1169-2025·2025-02-19

    Vios Bedside Monitor Pulse Oximeter Sensor Premature Failure and Incorrect Warnings

    Murata Vios, Inc. is recalling the Vios Monitoring System Bedside Monitor, Model BSM2050, due to premature failure of the pulse oximeter SpO2 sensor. When the sensor fails, the system displays an incorrect warning that may mask the actual monitoring problem.

    Product
    Vios Monitoring System Bedside Monitor, Model BSM2050, Software Version Numbers 1.54.20 and 1.56.00
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1119-2025·2025-02-19

    Pyxis Medication and Anesthesia Dispensing Systems Recalled for Software Vulnerabilities

    CareFusion recalls Pyxis medication dispensing systems due to software issues that could delay access to medications, result in incorrect doses, or allow unauthorized access.

    Product
    (1) Pyxis MedStation ES, Catalog No. 323; (2) Pyxis Anesthesia Station (PAS), Catalog No. 327; (3) Pyxis MedStation ES Tower, Catalog No. 352; (4) BD Pyxis CII Safe ES, Catalog No. 1116-00
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1168-2025·2025-02-19

    MediHoney Gel Wound Dressing Recall: Potential Induction Seal Defect

    Integra LifeSciences is recalling MediHoney Gel Wound & Burn Dressing Gel (Model 31815) due to potential induction seal defects in the tube packaging. Approximately 12,166 units were distributed worldwide, including throughout the United States and Malaysia.

    Product
    Brand Name: MediHoney¿ Gel Product Name: MediHoney¿ Wound & Burn Dressing Gel Model/Catalog Number: 31815 Software Version: N/A Product Description: MediHoney¿ Gel with Active Leptospermum Honey is a moist dressing made of Active Leptospermum Honey in combination with gelling
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0546-2025·2025-02-19

    Chocolate Drizzled Vanilla Granola Bars Recalled for Potential Metal Contamination

    Riverside Natural Foods is recalling Chocolate Drizzled Vanilla Granola Bars nationwide due to potential metal piece contamination. Affected products should not be consumed.

    Product
    1.Chocolate Drizzled Vanilla Granola Bars 25.5oz (30 bars) 2. Chocolate Drizzled Vanilla Granola Bars 4.2oz (5 bars) 3. Chocolate Drizzled Vanilla Granola Bars 0.85oz
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-0538-2025·2025-02-19

    Chocolate Banana Granola Bars Recalled for Potential Metal Contamination

    Riverside Natural Foods is recalling Chocolate Banana Granola Bars sold nationwide due to potential metal contamination. Consumers should not eat affected products and should consult a healthcare provider if consumed.

    Product
    1. Chocolate Banana Granola Bars; 5.1oz (6 bars) 2. Chocolate Banana Granola Bars; 0.85oz
    Category
    Food
    Distribution
    Distributed nationwide