18526–18550 of 78956

  • CriticalFDA (Drugs)·D-0244-2023·2023-02-08

    Easy Care first aid burn cream recalled for microbial contamination

    Easy Care first aid burn cream distributed nationwide and in Canada is recalled due to FDA-detected contamination with Bacillus lichenformis and Bacillus sonorensis. The product should not be used.

    Product
    Easy Care first aid Burn Cream (benzalkonium chloride 0.13% and lidocaine hydrochloride 0.5%), 0.9 g (0.03 oz) packets packaged in boxes of 10, Treatment for Burns, Made in China for Adventure Ready Brands, 944 Industrial Park Rd., Littleton, NH 03561, NDC 90107-0210, Product #…
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0965-2023·2023-02-08

    CADD Infusion Administration Set Recalled for Delivery Failure and False Alarms

    Smiths Medical is recalling CADD Administration Sets due to tubing occlusion that can prevent medication delivery and false pump alarms. This FDA Class I recall affects 214,668 units worldwide.

    Product
    CADD Administration Set, List Numbers: a) REF 21-7600-24, b) REF 21-7609-24, c) REF 21-7624-24, d) REF 21-7649-24, e) REF 21-7600-24JP, f) REF 21-7609-24JP, g) REF 21-7624-24JP, h) REF 21-7649-24JP Computerized Ambulatory Delivery Device
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0964-2023·2023-02-08

    CADD Infusion Administration Sets Recalled for Delivery Failure and Alarms

    FDA recalls 726,878 CADD Infusion Administration Sets due to potential tubing occlusion causing delivery failure and false alarm warnings.

    Product
    CADD Administration Set, List Numbers: a) REF 21-7308-24, b) REF 21-7309-24, c) REF 21-7310-24, d) REF 21-7308-24JP, e) REF 21-7309-24JP. Computerized Ambulatory Delivery Device
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0963-2023·2023-02-08

    CADD Infusion Administration Sets Recalled for Tubing Occlusion and False Alarms

    Smiths Medical is recalling CADD Administration Sets for two issues: tubing may become blocked, preventing medication delivery, and devices may show false alerts about disposable attachment status.

    Product
    CADD Administration Set, List Numbers: 1) REF 21-7300-24, 2) REF 21-7301-24 3) REF 21-7302-24, 4) REF 21-7321-24, 5) REF 21-7322-24, 6) REF 21-7323-24, 7) REF 21-7324-24, 8) REF 21-7333-24, 9) REF 21-7336-24, 10) REF 21-7339-24, 11) REF 21-7343-24, 12) REF 21-7349-24…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0248-2023·2023-02-08

    FDA Recalls Easy Care First Aid Kits for Bacterial Contamination

    GFA Production's Easy Care First Aid 25 Person kits are being recalled nationwide due to contamination with Bacillus bacteria. The affected first aid cream packets could pose a risk if applied to open wounds.

    Product
    Easy Care First Aid 25 Person 2009 ANSI, First Aid Kit, containing Easy Care first aid After Burn Cream 0.9 g packets, Product # 9999-2129
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0253-2023·2023-02-08

    Easy Care First Aid Kit Recalled for Microbial Contamination

    The FDA is recalling Easy Care First Aid kits containing After Burn Cream due to microbial contamination. The affected product was distributed nationwide and in Canada with lot number W06H15 (expiration August 15, 2024).

    Product
    Easy Care First Aid 10 Person 2009 ANSI, First Aid Kit, containing Easy Care first aid After Burn Cream 0.9 g packets, Product # 9999-2131
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0252-2023·2023-02-08

    CVS First Aid Home Burn Cream Packets Recalled for Bacterial Contamination

    CVS First Aid Home, First Aid Kit burn cream packets have been recalled due to bacterial contamination. The product contains Bacillus lichenformis and Bacillus sonorensis bacteria, creating a risk when applied to wounds or burns.

    Product
    CVS First Aid Home, First Aid Kit, containing Easy Care first aid After Burn Cream 0.9 g packets, Product # 2980-0700
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0249-2023·2023-02-08

    Easy Care First Aid Kits Recalled for Bacterial Contamination

    GFA Production is recalling Easy Care First Aid 10 Person First Aid Kits because the included After Burn Cream packets are contaminated with Bacillus bacteria. Contamination was identified through FDA laboratory testing.

    Product
    Easy Care First Aid 10 Person 2009 ANSI, First Aid Kit, containing Easy Care first aid After Burn Cream 0.9 g packets, Product # 9999-2128
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0245-2023·2023-02-08

    First Aid Kit Product Recalled Due to Bacterial Contamination

    A first aid kit containing topical burn cream has been recalled due to bacterial contamination with Bacillus species. The product (Lot W06I20) was distributed nationwide and in Canada.

    Product
    Adventure Marine 150, First Aid Kit, containing Easy Care first aid After Burn Cream 0.9 g packets, Product # 1015-0150
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0966-2023·2023-02-08

    CADD Administration Sets recall for delivery failure and false alarms

    Smiths Medical is recalling CADD Administration Sets due to potential tubing occlusion causing medication underdelivery and false alarm errors. The FDA classified this as a Class I recall affecting nearly 48 million units worldwide.

    Product
    CADD Administration Set, List Numbers: 1) REF 21-7300-24, 2) REF 21-7301-24, 3) REF 21-7302-24, 4) REF 21-7308-24, 5) REF 21-7309-24, 6) REF 21-7310-24, 7) REF 21-7322-24, 8) REF 21-7323-24, 9) REF 21-7324-24, 10) REF 21-7333-24, 11) REF 21-7343-24, 12) REF…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0962-2023·2023-02-08

    CADD Administration Set recall: medication underdelivery and false alarms

    Smiths Medical is recalling 1.6 million CADD Infusion System Administration Sets due to tubing occlusion causing medication underdelivery and false alarm conditions affecting patients worldwide.

    Product
    CADD Administration Set, List Numbers: a) REF 21-7346-24; b) REF 21-7363-24
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0929-2023·2023-02-08

    SARS-CoV-2 Antigen Rapid Test Kits Recalled for Lack of FDA Authorization

    Universal Meditech Inc. is recalling approximately 56,300 SARS-CoV-2 Antigen Rapid Test Kits distributed without FDA approval, clearance, or Emergency Use Authorization. Products were distributed nationwide in California and Texas.

    Product
    Products are labeled as: Skippack Medical Lab SARS-CoV-2 Antigen Rapid Test Kit (Colloidal Gold) 20 TESTS/1 KIT Green and white box under the brand DiagnosUS, and, White box without brand name labeled as "SARS -COV-2 ANTIGEN DEVELOPMENT MADE IN USA ORAL SWAB…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0247-2023·2023-02-08

    FDA Recalls First Aid Cream Packets Over Bacterial Contamination

    The FDA is recalling Adventure First Aid 1.5 first aid kits due to bacterial contamination found in the included burn cream packets. The contamination was identified through FDA laboratory testing.

    Product
    Adventure First Aid 1.5, First Aid Kit, containing Easy Care first aid After Burn Cream 0.9 g packets, Product # 0120-0212
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-0251-2023·2023-02-08

    FDA Recalls Easy Care First Aid Kit for Bacterial Contamination

    The FDA is recalling Easy Care First Aid Kits with contaminated After Burn Cream packets distributed nationwide and in Canada. Lab testing identified Bacillus lichenformis and Bacillus sonorensis contamination.

    Product
    Easy Care First Aid 25 Person 2009 ANSI, First Aid Kit, containing Easy Care first aid After Burn Cream 0.9 g packets, Product # 9999-2132
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1031-2023·2023-02-08

    Procedural trays recalled for potential sterile packaging breach

    Medline Industries recalls non-sterile procedural trays (LAPAROTOMY CDS) because sterile blades within the kits may puncture the outer foil packaging, compromising sterility.

    Product
    Non-sterile procedural trays labeled as LAPAROTOMY CDS, 2 per case
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1040-2023·2023-02-08

    Siemens Fluoroscopic X-ray Systems Risk of Boot Failure After Shutdown

    Certain Siemens fluoroscopic X-ray systems may only boot into backup mode after an abrupt shutdown, preventing full operation. This could necessitate cancelling or switching to alternative treatment systems.

    Product
    System Material # Artis zee floor 10094135 Artis zee ceiling 10094137 Artis zee multi-purpose 10094139 Artis zee biplane 10094141 Artis zeego 10280959 Artis Q floor 10848280 Artis Q ceiling 10848281 Artis Q biplane 10848282 Artis Q.zeego 10848283 Artis Q.zen floor…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1046-2023·2023-02-08

    Medline UNITE Foot & Ankle Screw Recalled for Intra-Operative Failure

    Medline Industries is recalling 420 units of UNITE FOOT & ANKLE Screws nationwide due to observed intra-operative screw failure when used with specific drill bit sizes. The failure occurs due to excessive torque during surgical insertion.

    Product
    MEDLINE UNITE FOOT & ANKLE Screw, Polyaxial Locking, Mini T8 (2.0x8mm), REF MMSL2008
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1035-2023·2023-02-08

    Non-sterile procedural knee trays recalled for potential packaging breach

    Medline Industries recalls non-sterile Total Knee procedural trays because sterile blades inside can puncture the outer foil packaging. This could compromise sterile blade integrity.

    Product
    Non-sterile procedural trays labeled as TOTAL KNEE KIT, 1 per case
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1025-2023·2023-02-08

    Cardiopulmonary Bypass Oxygenator Recalled for Loose Temperature Monitoring Adapter

    Medtronic Perfusion Systems is recalling 1,340 units of the Affinity Fusion Oxygenator due to reports that the Temperature Monitoring Adapter can come loose during or after use in cardiopulmonary bypass procedures.

    Product
    Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface, Custom Packs, REF CB811. Used in Cardiopulmonary bypass.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1034-2023·2023-02-08

    Procedural Trays with Sterile Blades May Have Damaged Packaging

    Medline Industries is recalling 45 units of procedural trays containing sterile surgical blades. The sharp blades may puncture the outer sterile packaging, potentially compromising sterility and increasing infection risk.

    Product
    Non-sterile procedural trays labeled as THEDA CLARK TOTAL KNEE CDS, 1 per case
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1033-2023·2023-02-08

    Non-sterile orthopedic procedural trays recalled for potential sterile packaging breach

    Medline Industries recalls non-sterile orthopedic procedural trays that may contain sterile blades capable of puncturing the protective foil packaging, compromising sterile barriers.

    Product
    Non-sterile procedural trays labeled as ORTHO TRAUMA, 1 per case
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1026-2023·2023-02-08

    Affinity Fusion Oxygenator adapter may loosen during cardiac surgery

    Medtronic is recalling Affinity Fusion Oxygenators because the Temperature Monitoring Adapter may come loose during setup or disassembly of the heart-lung machine used in cardiac surgery. No injuries have been reported.

    Product
    Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface, Custom Packs, REF CB841. Used in Cardiopulmonary bypass.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1036-2023·2023-02-08

    OSS Modular Arthrodesis Nail Recalled for Missing Locking Bolts

    Biomet is recalling certain OSS Modular Arthrodesis Nails due to missing locking bolts that could require extended surgery. Affected units are Lot 136620.

    Product
    OSS Modular Arthrodesis Nail, 7 Degree Collar Assembly with Locking Bolts-For use in the replacement of segmental defects of long bone, including midshaft replacement, and arthrodesis of the knee Item Number: CP260602
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1024-2023·2023-02-08

    Affinity Fusion Oxygenator temperature monitoring adapter may loosen during cardiac surgery

    The temperature monitoring adapter on Medtronic's Affinity Fusion Oxygenator may come loose during cardiopulmonary bypass procedures. The manufacturer has received multiple complaints about this issue.

    Product
    Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface, OXY/CVR COMBO BB841 FUSION W/BALANCE 26L, REF BB841. Used in Cardiopulmonary bypass.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1051-2023·2023-02-08

    Bard Catheter Repair Kits Recalled for Hardened, Unusable Adhesive

    Bard Peripheral Vascular is recalling multiple catheter repair kits because the adhesive may be hardened or coagulated, rendering the kits unusable. Approximately 7,520 units were distributed worldwide.

    Product
    Catalog Number / Product Description 0601600 2.7F Broviac CV Catheter Repair Kit 0601610 4.2 Fr Broviac CV Catheter Repair Kit 0601620 6.6F Broviac CV Catheter Repair Kit 0601630 9.6F Hickman CV Catheter Repair Kit 0601680 Hickman / Leonard CV Catheter Repair Kit (all…
    Category
    Medical Device
    Distribution
    Distributed nationwide