  • HighFDA (Devices)·Z-1179-2023·2023-03-08

    Surgipro Monofilament Polypropylene Sutures Recalled for Sterile Barrier Breach

    Surgipro Monofilament Polypropylene Sutures are recalled due to a sterile barrier breach in the breather pouch, which may cause infection or vision loss during ophthalmic procedures.

    Product
    Surgipro Monofilament Polypropylene Sutures Product Description CP-535 SURGIPRO* 1 BLU 100CM GS24 X36 CP-824 SURGIPRO* 1 BLU 150CM GS26 X24 CP-825 SURGIPRO* 2 BLU 150CM GS26 X24 VP-543 SURGIPRO* 2-0 BLU 120CM V20 DA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1170-2023·2023-03-08

    Bone fixation plates recalled due to product packaging mix-up

    Wright Medical Technology is recalling ORTHOLOC 3DSi CLAW II bone fixation plates due to packaging mix-up in specific lots. Packages contained incorrect product codes.

    Product
    ORTHOLOC 3DSi CLAW II 4 HOLE Plate, Size 25MM, REF 40241425, Bone fixation device
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·23V153000·2023-03-08

    2023 International MV and HV Vehicles Recalled for Driveshaft Separation Risk

    Navistar is recalling certain 2023 International HV and 2023-2024 International MV vehicles due to incorrectly installed rear axle wedge shims that can cause driveshaft separation and loss of drive power. This increases the risk of a crash.

    Product
    INTERNATIONAL — INTERNATIONAL MV, HV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0362-2023·2023-03-08

    Phenylephrine injection recalled due to lack of sterility assurance

    Nephron Sterile Compounding Center is recalling Phenylephrine HCl injection nationwide due to lack of assurance of sterility. Lot PS2008A with expiration 03/07/2023 is affected.

    Product
    Phenylephrine HCl in 0.9% Sodium Chloride Injection, USP, 50 mg/250 mL (200 mcg/mL), 250 mL Single-Dose Container bottle, packaged in 15 x 1 IV Bottles per carton, Rx Only, Nephron 503B Outsourcing Facility, 4500 12th St. Extension, West Columbia, SC 29172, NDC 69374-321-25.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0361-2023·2023-03-08

    Phenylephrine HCl Injection Recalled for Sterility Assurance Deficiency

    Nephron is recalling 24,870 Phenylephrine HCl Injection vials nationwide due to lack of sterility assurance. No illnesses have been reported.

    Product
    Phenylephrine HCl Injection, USP, 0.8 mg/10 mL (80 mcg/mL), 10 mL Single-Dose Vial, packaged in 30 x 10 mL Single-Dose Vials per carton, 12 x 30 Vials Carton per case, Rx Only, Nephron 503B Outsourcing Facility, 4500 12th St. Extension, West Columbia, SC 29172, NDC 69374-301-10.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1180-2023·2023-03-08

    Surgipro II Surgical Sutures recalled for sterile barrier breach

    Covidien is recalling Surgipro II Monofilament Polypropylene Sutures due to a sterile barrier breach in the breather pouch that may cause infection or vision loss in ophthalmic procedures with direct patient contact.

    Product
    Surgipro II Monofilament Polypropylene Sutures Product Description Model Number VP-421X SURGIPRO*II 4-0 90CM V20 DA7P VP421X VP-435-X SURGIPRO II 4-0 90CM KV5 DA7P VP435X VP-541X SURGIPRO*II 4-0 BLU 120CM V20DA VP541X VP-542-X SURGIPRO II 3-0 BLU 120CM V20DA VP542X…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1197-2023·2023-03-08

    Contact Lenses Recalled for Misaligned Axis Causing Poor Vision

    CooperVision is recalling Biofinity XR Toric contact lenses due to misaligned axis in manufacturing that results in incorrect lens power. Users may experience poor visual acuity.

    Product
    Biofinity XR Toric 6-pack- Soft (hydrophilic) Contact Lens (extended wear)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1194-2023·2023-03-08

    Vascular diagnostic devices recalled due to air embolism misconnection risk

    Unetixs Vascular recalls MultiLab Series II vascular diagnostic devices worldwide due to a design flaw where air lines can be misconnected to IV lines, potentially causing air embolism.

    Product
    MultiLab Series II LHS TI & ERGO non-invasive vascular diagnostic device, Model Number 11949-0000-01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1195-2023·2023-03-08

    Vascular Diagnostic Device Recalled for Risk of Air Line Misconnection

    Unetixs Vascular recalls MultiLab Series II ROODRA vascular diagnostic devices due to luer fittings that may allow air line misconnection to intravenous lines, potentially causing air embolism.

    Product
    MultiLab Series II ROODRA non-invasive vascular diagnostic device, Model Number 11986-0000-01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1201-2023·2023-03-08

    Medical Device Middleware: MYLA Software Fails to Apply AST Filter Rules

    Biomerieux MYLA laboratory middleware may fail to apply activated antibiotic susceptibility test (AST) filter rules when sending results to clinicians. The defect affects VITEK MS users with versions 4.8.x and 4.9.

    Product
    MYLA comprises AST Filters in conjunction with VITEK MS; middleware which connects microbiology laboratory instruments for ID/AST and blood culture activities and the laboratory information system (LIS).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1181-2023·2023-03-08

    Ti-Cron Surgical Sutures Recalled Due to Sterile Barrier Breach

    Covidien is recalling Ti-Cron Coated Braided Polyester Sutures due to a sterile barrier breach in the breather pouch. The defect could allow bacterial contamination, posing a risk of infection or vision loss during ophthalmic procedures.

    Product
    Ti-Cron Coated Braided Polyester Suture Product Description 88862775-31 TICRON* 4-0 BLU 75CM CV327DA 88862880-41 TICRON* 3-0 WHI 75CM Y31DA 88863012-61 TICRON* 0 BLU 90CM C16 X36 88863015-61 TICRON* 0 BLU 120CM V20X36 88863017-51 TICRON* 2-0 BLU 120CM SKX36 88863026-71…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1176-2023·2023-03-08

    Sofsilk Coated Braided Silk Sutures recalled for sterile barrier breach

    Covidien is recalling Sofsilk Coated Braided Silk Sutures due to a sterile barrier breach in the breather pouch. The breach may cause infection or vision loss during ophthalmic procedures involving direct patient contact.

    Product
    Sofsilk Coated Braided Silk Suture Product Description CS-211 SOFSILK* 4-0 BLK 45CM CVF21 X36 CS211 CS-490 SOFSILK* 2-0 BLK 75CM GS11 X36 CS490 CS-562 SOFSILK* 2-0 BLK 75CM GS23 X36 CS562 GS-823 SOFSILK* 2-0 BLK 75CM V30 X36 GS823 GS-835 SOFSILK* 1 BLK 75CM V20 X36…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1186-2023·2023-03-08

    Triton Canister Software Labeling May Cause Inaccurate Blood Loss Estimates

    Stryker is recalling Triton Canister Software due to labeling issues that may cause inaccurate blood loss estimates. This could delay recognition of or prolong postpartum hemorrhage, potentially requiring more aggressive treatment.

    Product
    Triton Canister Software Catalog Number: GAUS-2. Intended adjunct in the estimation of blood loss.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0359-2023·2023-03-08

    Nephron Phenylephrine HCl Injection Recalled for Sterility Assurance

    Nephron Sterile Compounding Center LLC is recalling Phenylephrine HCl Injection due to lack of assurance of sterility. The recall affects 546,450 vials distributed nationwide.

    Product
    Phenylephrine HCl Injection, USP, 1 mg/10 mL (100 mcg/mL), 10 mL Single-Dose Vial, packaged in 30 x 10 mL Sterile Single-Dose Vials per carton, 12 x 30 Vials Carton per case, Rx Only, Nephron 503B Outsourcing Facility, 4500 12th St. Extension, West Columbia, SC 29172, NDC…
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1184-2023·2023-03-08

    Stryker Blood Loss Estimator Inserts Recalled for Inaccurate Measurement

    Stryker is recalling Medivac Guardian 2L blood loss estimator inserts and labels for measurement inaccuracy. The device may output incorrect estimates, potentially delaying postpartum hemorrhage treatment.

    Product
    Finished Goods Box of 50 Inserts and Scanning Labels for Medivac Guardian 2L Catalog Number: FG 12010. Intended adjunct in the estimation of blood loss.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1208-2023·2023-03-08

    Dental Handpieces Recalled Due to Detachable Screw Component Risk

    Coltene Whaledent Inc is recalling SciCan STATIS SL S10001 dental handpieces because the screw connection between the turbine head and push button may loosen and fall off, creating a risk of swallowing or inhaling these parts.

    Product
    SciCan STATIS SL S10001 Dental Handpieces-Intended for the removal of carious material, reducing hard tooth structure, cavity preparation, finishing tooth preparations, restorations and for polishing teeth. Model Number: S10001
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1172-2023·2023-03-08

    Dermalon Surgical Sutures recalled for sterile barrier breach

    Covidien is recalling Dermalon monofilament nylon sutures due to a breach in the sterile barrier of the breather pouch. Affected units may cause infection or vision loss if used in ophthalmic procedures involving direct patient contact.

    Product
    Dermalon Monofilament Nylon Suture: (1) 88861741-11 DERMALON* 6-0 BLU 45CM C1 (2) 88861747-11 DERMALON* 6-0 BLU 45CM C12 (3) 88861749-24 DERMALON* 5-0 BLU 45CM P13 (4) 88861756-11 DERMALON* 6-0 BLU 45CM C13 (5) 88861757-41 DERMALON* 3-0 BLU 75CM C13
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0357-2023·2023-03-08

    FDA Recalls Norepinephrine Injection Due to Sterility Concerns

    Nephron Sterile Compounding Center is recalling Norepinephrine Bitartrate injection nationwide due to lack of sterility assurance. The recall affects 305,895 bottles across 13 lots.

    Product
    Norepinephrine Bitartrate in 0.9% Sodium Chloride Injection, USP, 4 mg/250 mL (16 mcg/mL*), 250 mL Single-Dose Container bottle, packaged in 15 IV Bottles per carton, Rx Only, Nephron 503B Outsourcing Facility, 4500 12th St. Extension, West Columbia, SC 29172, NDC 69374-319-25.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1174-2023·2023-03-08

    Monosof nylon sutures recalled for sterile barrier breach

    Covidien is recalling Monosof nylon sutures due to sterile barrier breach in the breather pouch, which may cause infection or vision loss in ophthalmic procedures. The recall affects 54,288 units distributed nationwide and globally.

    Product
    Monosof Monofilament Nylon sutures: Product Description CN-724 MONOSOF* 1 BLK 100CM GS25 X36 CN-791 MONOSOF* 2-0 BLK 100CM GCC90X36 CN-791-12 MONOSOF* 2-0 BLK 100CM GCC90 CN-793 MONOSOF* 1 BLK 100CM GCC90 X36 CN-793-12…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1178-2023·2023-03-08

    Surgilon Braided Nylon sutures recalled due to sterile barrier defect

    Covidien is recalling Surgilon Braided Nylon sutures due to a sterile barrier breach in the breather pouch that could allow bacterial contamination, potentially causing infection or vision loss in ophthalmic procedures.

    Product
    Surgilon Braided Nylon suture Product Description: 88861883-51 SURGILON* 2-0 BLK 75CM C16 88861915-71 SURGILON* 1 BLK 75CM GS11 88861919-31 SURGILON* 4-0 BLK 7X75CMPCT 88861919-41 SURGILON* 3-0 BLK 7X75CMPCT 88861919-51 SURGILON* 2-0 BLK 7X75CMPCT 88861919-61 SURGILON* 0…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1206-2023·2023-03-08

    X-ray System Overhead Crane May Continue Moving Unexpectedly

    Carestream Health is recalling certain DRX-Compass/DR-FIT X-ray systems because the overhead tube crane may unexpectedly continue moving after Z-axis motorized buttons are pressed and released, potentially causing injury.

    Product
    DRX-Compass/DR-FIT X-ray Systems with Firmware version 2.3.2.0/2.3.2.4. For use in obtaining diagnostic quality radiographic images to aid the physician with diagnosis. CATALOG #(s): 8624181 X-RAY SYSTEM CONSOLE PDU 3P 380-480 C/F 8624199 X-RAY SYSTEM CONSOLE PDU 3P 208-240…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0355-2023·2023-03-08

    Diltiazem HCl Injectable Drug Recalled for Sterility Assurance Failure

    Nephron Sterile Compounding Center is recalling Diltiazem HCl injectable due to lack of sterility assurance. The FDA Class II recall affects 4,743 bottles distributed nationwide.

    Product
    Diltiazem HCl in 0.7% Sodium Chloride Injection, 125 mg/125 mL (1 mg/mL), 125 mL Single-Dose Container bottle, packaged in 15 x 1 IV Bottles per carton, Rx Only, Nephron 503B Outsourcing Facility, 4500 12th St. Extension, West Columbia, SC 29172, NDC 69374-997-15.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighNHTSA·23V157000·2023-03-08

    Eveland Scamp Travel Trailer Recall for Gas Leak Risk

    Eveland's Inc. is recalling 2022 Scamp travel trailers because damaged burner control valves may cause a gas leak, increasing fire risk.

    Product
    EVELAND — EVELAND SCAMP
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0358-2023·2023-03-08

    Injectable Norepinephrine Recalled Nationwide for Sterility Assurance Failure

    FDA recalls norepinephrine bitartrate injection (270,291 bottles nationwide) due to lack of sterility assurance. The injectable medication from Nephron Sterile Compounding Center poses infection risk if used.

    Product
    Norepinephrine Bitartrate in 0.9% Sodium Chloride Injection, USP, 16 mg/250 mL (64 mcg/mL*), 250 mL Single-Dose Container bottle, packaged in 15 IV Bottles per carton, Rx Only, Nephron 503B Outsourcing Facility, 4500 12th St. Extension, West Columbia, SC 29172, NDC 69374-315-25.
    Category
    Drug
    Distribution
    Distributed nationwide
  • ModerateFDA (Drugs)·D-0363-2023·2023-03-08

    Fentanyl Injection Syringes Recalled for Subpotent Active Ingredient

    SCA Pharmaceuticals is recalling 2,125 fentanyl injection syringes nationwide due to subpotency—the product contains less active ingredient than labeled. The firm voluntarily initiated this Class III recall in February 2023.

    Product
    Fentanyl 1,500 mcg/30 mL syringe, Injection for Intravenous Use, Concentration = 50 mcg/mL, Preservative Free, Rx Only, Single Dose Container, SCA Pharmaceuticals, Windsor CT 06095, NDC# 70004-0200-16.
    Category
    Drug
    Distribution
    Distributed nationwide