The Recall Desk

State

Arkansas product recalls

72,940 recalls have nationwide distribution and so reach Arkansas. 5,513 additional recalls listed Arkansas specifically in their distribution scope.

What the numbers show

Total
5,513
Critical
1,018
Severe
1,210
Most recent
2026-09-09

Of the 5,513 recalls naming Arkansas we have scored against our rubric, 1,018 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,210 (22%) are Severe.

These figures cover only the 5,513 recalls whose distribution notice names Arkansas specifically. The 72,940 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

4051–4075 of 78453

  • HighNHTSA·25V862000·2025-12-12

    Ford Recalls 2025-2026 Corsair and Escape for Seat Belt Defect

    Ford is recalling 2025-2026 Corsair and Escape vehicles because rear seat belt retractors may not be securely fastened, increasing injury risk in crashes.

    Product
    FORD — FORD, LINCOLN ESCAPE, CORSAIR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V859000·2025-12-11

    Honda Recalls 2016-2020 Acura ILX for Brake Master Cylinder Defect

    Honda is recalling 2016-2020 Acura ILX vehicles because contaminated brake fluid may deform a seal, causing an internal leak and reduced brake function.

    Product
    ACURA — ACURA ILX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereCPSC·26142·2025-12-11

    Garment steamers recalled after hot water leaks caused burn injuries

    About 2,840 VEVOR Garment Steamers are being recalled because they can leak or spit hot water. Reported cap failures resulted in two burn injuries, including a second-degree burn with permanent scarring.

    Product
    VEVOR Garment Steamers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • SevereNHTSA·25V858000·2025-12-11

    Honda Recalls 2025 CR-V Fuel Cell EVs for Fuel Cell Leak Risk

    Honda is recalling 2025 CR-V Fuel Cell EVs because coolant may leak into the fuel cell stack, causing an internal short circuit and loss of drive power.

    Product
    HONDA — HONDA CR-V FUEL CELL EV
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighNHTSA·25E087000·2025-12-11

    Lippert Recalls Q'Straint QRT-Max Wheelchair Restraints Due to Locking Defect

    Lippert is recalling Q'Straint QRT-Max wheelchair restraints because the retractors may not lock, preventing proper securing of the wheelchair.

    Product
    EQUIPMENT ADAPTIVE/MOBILITY:WHEELCHAIR RESTRAINTS/SECUREMENT:LATCH/ANCHOR: recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26146·2025-12-11

    Baby bath seats recalled because they are unstable and can tip over

    About 8,960 YCXXKJ baby bath seats are being recalled because they are unstable and can tip over while in use, posing a risk of serious injury or death due to drowning.

    Product
    YCXXKJ Baby Bath Seats
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighNHTSA·25V856000·2025-12-11

    GMC Canyon pickups recalled over air bag software that may deploy improperly

    General Motors is recalling 1,120 GMC Canyon AT4X AEV vehicles because incorrect sensing and diagnostic module software may cause a second stage passenger air bag deployment when only a first stage is intended.

    Product
    GMC — GMC CANYON
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·26141·2025-12-11

    Infant walkers recalled over fall and head entrapment hazards

    About 2,650 Uuoeebb infant walkers are being recalled because they can fit through a standard doorway and fail to stop at the edge of a step, and their leg openings can entrap a child's head.

    Product
    Uuoeebb Infant Walkers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26138·2025-12-11

    Electric bicycles recalled because chainring bolts can come loose

    About 700 model year 2026 Trek Domane+ and Checkpoint+ electric bicycles are being recalled because the chainring bolts can come loose, causing the chainring to separate from the bike.

    Product
    Model Year 2026 Trek-branded Domane+ ALR 5, Domane+ ALR 6 AXS, Checkpoint+ SL 6 and Checkpoint+ SL 7 Electric Bicycles
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • HighCPSC·26148·2025-12-11

    Youth ATVs recalled for failing the mandatory ATV safety standard

    About 2,290 X-Pro Eagle and FRP Sahara 40cc youth ATVs are being recalled because their mechanical suspension fails safety requirements and the handlebars pose a laceration hazard.

    Product
    X-Pro Eagle 40cc Youth ATVs and FRP Sahara 40cc Youth ATVs
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-0586-2026·2025-12-10

    Infusion pump administration sets recalled over incorrect assembly of one lot

    Fresenius Kabi USA is recalling 483 cases of Ivenix LVP Primary Administration Sets after incorrect assembly of a specific lot that the firm states could result in serious patient injury.

    Product
    IVENIX INFUSION SYSTEM, LVP Primary Administration Set, Dual-Inlet, Low-Sorbing, Needle-Free Port, Dual Y-Site (Qty 25). Large Volume Infusion Pump Administration Set.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·H-0302-2026·2025-12-10

    Protein powder recalled because the label omits milk and claims allergen free

    Genepro Protein is recalling 250 bags of Genepro Whey 4th Generation protein because the labeling contains incorrect ingredient information and fails to declare milk as an allergen.

    Product
    Genepro Whey 4th Generation Plasma Treated Protein, unflavored, Net Wt. 225g, 30 servings, packaged in a resealable mylar bag, UPC 850053365126, Manufactured For: Genepro Protein, Inc. 15000 Weston Parkway, Cary NC 27513 Front label reads, in part: "* LACTOSE FREE * DAIRY FREE *
    Category
    Food
    Distribution
    37 states
  • HighNHTSA·25V851000·2025-12-10

    Blue Bird Recalls School Buses With Defective Wheelchair Restraints

    Blue Bird is recalling 2026-2027 Vision and All American school buses because wheelchair restraints may fail to lock, increasing injury risk.

    Product
    BLUE BIRD — BLUE BIRD VISION SCHOOL BUS (ELECTRIC), ALL AMERICAN SCHOOL BUS, VISION SCHOOL BUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0220-2026·2025-12-10

    Mozzarella and provolone cheese blend recalled over potential metal fragments from supplier

    Great Lakes Cheese is recalling 4,131 cases of mozzarella and provolone shredded cheese blend, sold under four brands, over potential metal fragments from a supplier raw material.

    Product
    Mozzarella and provolone shredded cheese blend (containing low-moisture part-skim mozzarella and not-smoked provolone cheeses), individually packaged in a plastic bag, as: 1) Freedom's Choice Pizza Blend - Fine-Cut, 32 oz., UPC 4279810410, 6/case 2) Good & Gather Mozzarella & P
    Category
    Food
    Distribution
    32 states