The Recall Desk

State

Alabama product recalls

73,912 recalls have nationwide distribution and so reach Alabama. 6,379 additional recalls listed Alabama specifically in their distribution scope.

What the numbers show

Total
6,379
Critical
1,129
Severe
1,605
Most recent
2026-11-11

Of the 6,379 recalls naming Alabama we have scored against our rubric, 1,129 (18%) are Critical — deaths or serious injuries reported, or the agency’s own highest classification — and 1,605 (25%) are Severe.

These figures cover only the 6,379 recalls whose distribution notice names Alabama specifically. The 73,912 nationwide recalls listed below reach every state, so counting them here would make every state page show the same numbers.

69451–69475 of 80291

  • SevereNHTSA·13V187000·2013-05-09

    KME Emergency Vehicles Recalled for Steering Column Grease Fitting Defect

    Kovatch is recalling specific KME emergency vehicles because a grease fitting in the steering column may tear the cover, potentially causing a loss of steering control.

    Product
    KME — KME PREDATOR SS, ARFF, PREDATOR, PANTHER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V188000·2013-05-09

    Magic Tilt Boat Trailer Hydraulic Brake Actuator Recall

    Magic Tilt is recalling boat trailers with defective hydraulic brake actuators that may fail, causing loss of braking ability and increasing crash risk.

    Product
    SERVICE BRAKES, HYDRAULIC recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighCPSC·13187·2013-05-09

    Toro Recalls Z Master Riding Mowers Due to Fire Hazard

    Toro is recalling specific 2012 and 2013 Z Master Commercial riding mowers because the idler pulley can rub against the fuel tank, posing a fire hazard.

    Product
    Toro® Z Master® Riding Mowers
    Category
    Consumer Product
    Distribution
    Distributed nationwide
  • CriticalFDA (Food)·F-1369-2013·2013-05-08

    Farm Rich Pizza Dippers Recalled Due to E. coli O121 Contamination

    Rich Products Corp is recalling Farm Rich Better For You Pizza Dippers nationwide due to potential E. coli O121 contamination.

    Product
    Farm Rich Better For You Pizza Dippers-Pizza Dough made with Whole Wheat Flour and Stuffed with Mozzarella Cheese and Reduced Fat Mozzarella Cheese, Net Wt. 27-LBS (10 X 2.7-LB), UPC Code 00041322652782, Product Code 65278.
    Category
    Food
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1170-2013·2013-05-08

    Hospira Recalls GemStar Infusion Pumps Due to Unexpected Shutdowns

    Hospira Inc. is recalling GemStar infusion pumps because they may shut off during use without warning, potentially interrupting patient medication delivery.

    Product
    The GemStar Pump is a small and lightweight, single channel infusion device designed for use in the home, in the hospital, or anywhere electronic infusion is required. The GemStar Pump can be powered by AC mains adaptor, rechargeable battery pack, docking station, or two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1189-2013·2013-05-08

    Philips HeartStart MRx Monitor/Defibrillator Recalled for Therapy Failure Risk

    Philips is recalling HeartStart MRx Monitor/Defibrillators because they may fail to deliver defibrillation therapy in Manual Defib or AED mode.

    Product
    HeartStart MRx Monitor/Defribillator; Product Codes: M3536A, M3536J, M3536M, M3536MC, M3536M2, M3536M4, M3536M5, M3536M6. The HeartStart MRx is for use for the termination of ventricular tachycardia and ventricular fibrillation.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1373-2013·2013-05-08

    Buffalo Trace Bourbon Fudge Sauce Recalled for Missing Allergen Labeling

    Buffalo Trace Distillery is recalling 1,686 jars of Bourbon Fudge Sauce because the label failed to list milk and soy allergens.

    Product
    BUFFALO TRACE BOURBON FUDGE SAUCE 8 oz glass jars Net Wt. 8 fl. oz./227 g, PRODUCED BY: APPLECREEK ORCHARDS LLC P.O. Box 8383 Lexington, KY 40533 BUFFALO TRACE DISTILLERY 113 Great Buffalo Trace Franklin County Frankfort, KY 40601 800-654-8471 e-mail…
    Category
    Food
    Distribution
    27 states
  • SevereFDA (Food)·F-1375-2013·2013-05-08

    Buffalo Trace Barbecue Sauce Recalled for Missing Soy and Anchovy Allergens

    Buffalo Trace Distillery is recalling 16 fl. oz. jars of Original Flavor Barbecue Sauce because the label failed to list soy and anchovy allergens.

    Product
    BUFFALO TRACE ORIGINAL FLAVOR BARBEQUE SAUCE Net Wt. 16 fl. oz./532 ml PRODUCED BY: APPLECREEK ORCHARDS LLC P.O. Box 8383 Lexington, KY 40533 BUFFALO TRACE DISTILLERY 113 Great Buffalo Trace Franklin County Frankfort, KY 40601 800-654-8471 e-mail: [email protected]…
    Category
    Food
    Distribution
    27 states
  • SevereNHTSA·13V182000·2013-05-08

    Spartan Motorhome Chassis Recall for Steering Bracket Cracking

    Spartan Motors is recalling 2006-2011 K2, K3, and MM motorhome chassis because steering brackets may crack and detach, causing loss of steering.

    Product
    SPARTAN — SPARTAN K3, MM, K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1191-2013·2013-05-08

    Medtronic Recalls DBS Therapy Kits Due to Potential Lead Damage

    Medtronic is recalling DBS Therapy for Dystonia Kits because the provided lead cap may damage the lead connector, potentially compromising the device.

    Product
    Medtronic DBS Therapy for Dystonia Kit, models 3317, 3319, 3337 and 3339. Sterile and Non-Pyrogenic. Product Usage: Dystonia Therapy Kit is indicated for unilateral or bilateral stimulation of the internal globus pallidus (GPi) or the subthalamic nucleus (STN) to aid in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1169-2013·2013-05-08

    Hospira GemStar Infusion Pumps Recalled for Unintended Shutdowns

    Hospira Inc. is recalling GemStar infusion pumps because they may shut off during use without warning. The recall affects pumps distributed worldwide.

    Product
    The GemStar Pump is a small and lightweight, single channel infusion device designed for use in the home, in the hospital, or anywhere electronic infusion is required. The GemStar Pump can be powered by AC mains adaptor, rechargeable battery pack, docking station, or two…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Drugs)·D-308-2013·2013-05-08

    Hospira Recalls Morphine Sulfate Injection Due to Sterility Concerns

    Hospira Inc. is recalling 26,100 vials of Morphine Sulfate Injection because a loose crimp on the vial cap may compromise sterility.

    Product
    MORPHINE SULFATE — MORPHINE SULFATE (MORPHINE SULFATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • SevereNHTSA·13V185000·2013-05-08

    Temsa Recalls TS35C Coach Buses Due to Fuel Tank Leak Risk

    Temsa is recalling 172 model year 2011-2013 TS35C coach buses because a production error may cause the fuel tank to leak, posing a fire risk.

    Product
    TEMSA — TEMSA TS35C
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1159-2013·2013-05-08

    Hospira Recalls GemStar Infusion Pumps Due to Battery Data Loss

    Hospira Inc. is recalling GemStar infusion pumps because low battery levels can corrupt history logs and cause an error that prevents the device from being used.

    Product
    GemStar Pump - Battery Product Usage: The GemStar Pump is a small and lightweight, single channel infusion device designed for use in the home, in the hospital, or anywhere electronic infusion is required. The GemStar Pump can be powered by AC mains adaptor, rechargeable…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1368-2013·2013-05-08

    Rich Products Recalls Farm Rich Pizza Dough Stuffed with Mozzarella

    Rich Products Corp is recalling Farm Rich Stuffed Crust Pizza Dippers potentially contaminated with E. coli O121. The recall covers nationwide distribution.

    Product
    Farm Rich Stuffed Crust Pizza Dippers-Pizza Dough Stuffed with Mozzarella Cheese, Net Wt. 27-LBS (10 X 2.7-LB), UPC Code 10041322652659, Product Code 65265; Net Wt. 25-LB (1 X 25-LB) UPC Code 10041322652680, Product Code 65268.
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1177-2013·2013-05-08

    Maquet SERVO-i Ventilator Battery Modules Recalled for Shorter Run Time

    Maquet is recalling SERVO-i ventilator battery modules because some units have shorter battery run times than expected.

    Product
    Maquet Getinge Group battery modules for use with Maquet SERVO-i ventilator systems (Part #6487180). Battery for use with the SERVO-i Ventilator System. The SERVO-i Ventilator System is intended for treating and monitoring patients ranging from neonates to adults with…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1190-2013·2013-05-08

    Medtronic Recalls Deep Brain Stimulation Lead Kits Due to Damage Risk

    Medtronic is recalling 30,000 Deep Brain Stimulation lead kits worldwide because the provided lead cap may damage the lead connector during use.

    Product
    Medtronic DBS Lead Kit for Deep Brain Stimulation, models 3387, 3387S, 3389, 3389S, 3391, 3391S. Sterile and Non-Pyrogenic. Product Usage: The deep brain stimulation system delivers electrical stimulation to selected targets in the brain. DBS Leads are indicated for…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1367-2013·2013-05-08

    Rich Products Recalls Mozzarella Bites for E. coli O121 Contamination

    Rich Products Corp is recalling Mozzarella Bites potentially contaminated with E. coli O121. The recall covers 820,577 cases distributed nationwide.

    Product
    Mozzarella Bites distributed under the following labels: Farm Rich Cheese In a Pizzeria Style Crust, Product Code 36450 Net Wt. 22-oz bag-UPC Code 0 41322 37443 1; Product Code 37443 Net Wt. 22-oz bag-UPC Code 0 41322 37443 1; Product Code 37433 Net Wt. 22-oz bag-UPC Code 0…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1376-2013·2013-05-08

    Buffalo Trace Hot Barbeque Sauce Recalled for Missing Allergen Labels

    Buffalo Trace Distillery is recalling 16 fl. oz. jars of Hot Barbeque Sauce because the labels failed to list soy and anchovy allergens.

    Product
    BUFFALO TRACE HOT BARBEQUE SAUCE Net Wt. 16 fl. oz./532 ml PRODUCED BY: APPLECREEK ORCHARDS LLC P.O. Box 8383 Lexington, KY 40533 BUFFALO TRACE DISTILLERY 113 Great Buffalo Trace Franklin County Frankfort, KY 40601 800-654-8471 e-mail: [email protected] website…
    Category
    Food
    Distribution
    27 states
  • SevereFDA (Food)·F-1374-2013·2013-05-08

    Buffalo Trace Meat Marinade Recalled for Missing Wheat and Anchovy Allergens

    Buffalo Trace Distillery is recalling 12 fl. oz. meat marinade bottles because the label failed to list wheat and anchovy allergens.

    Product
    BUFFALO TRACE MARINADE FOR MEAT Net Wt. 12 fl. oz. PRODUCED BY: APPLECREEK ORCHARDS LLC P.O. Box 8383 Lexington, KY 40533 BUFFALO TRACE DISTILLERY 113 Great Buffalo Trace Franklin County Frankfort, KY 40601 800-654-8471 e-mail: [email protected] website…
    Category
    Food
    Distribution
    27 states
  • SevereFDA (Food)·F-1370-2013·2013-05-08

    Farm Rich Pizza Dippers Recalled for Potential E. coli O121 Contamination

    Rich Products Corp is recalling Farm Rich Better For You Pizza Dippers nationwide due to potential E. coli O121 contamination.

    Product
    Farm Rich Better For You Pizza Dippers-Pizza Dough Stuffed with Reduced Fat Mozzarella Cheese, Net Wt 25-LBS (5 X 5-LB), UPC Code 10041322652338, Product Code 65233.
    Category
    Food
    Distribution
    Distributed nationwide