  • HighFDA (Devices)·Z-1672-2026·2026-04-08

    Philips Allura Xper FD20/15 OR Table X-ray may not start

    Philips is recalling the Allura Xper FD20/15 OR Table because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD20/15 OR Table; System Code: 722059;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1676-2026·2026-04-08

    Philips Azurion 7 B20 X-ray may not start from foot switch

    Philips is recalling the Azurion 7 B20 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Azurion 7 B20; System Code: (1)722068, (2)722226, (3)722236;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1699-2026·2026-04-08

    da Vinci grasping retractor instruments recalled over broken grip cables

    Intuitive Surgical is recalling da Vinci S and Si Grasping Retractor Instruments following increased complaints of broken or frayed grip cables in reusable instruments.

    Product
    Brand Name: da Vinci S, Si Grasping Retractor Instrument Product Name: da Vinci S, Si Grasping Retractor Instrument Model/Catalog Number: 420278 Software Version: NA Product Description: EndoWrist Instruments or Da Vinci S/Si Reusable instruments, including blunt and sharp en
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1659-2026·2026-04-08

    Philips Allura Xper FD10C X-ray may not start from foot switch

    Philips is recalling the Allura Xper FD10C because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD10C; System Code: 722001;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1670-2026·2026-04-08

    Philips Allura Xper FD20/20 OR Table X-ray may not start

    Philips is recalling the Allura Xper FD20/20 OR Table because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD20/20 OR Table; System Code: 722039;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1657-2026·2026-04-08

    Atellica hemoglobin A1c assay may return depressed patient results

    Siemens is recalling Atellica CH Enzymatic Hemoglobin A1c because results may be depressed when the RCRP reagent is processed on the same analyzer, with bias increasing over time.

    Product
    Atellica CH Enzymatic Hemoglobin A1c (A1c_E); Siemens Material Number (SMN): 11097536;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0409-2026·2026-04-08

    Quality Choice irritation relief eye drops recalled over sterility assurance

    Quality Choice Eye Drops Irritation Relief, containing tetrahydrozoline HCl and zinc sulfate, are being recalled for lack of assurance of sterility. 182,424 bottles are affected.

    Product
    QUALITY CHOICE EYE DROPS IRRITATION RELIEF — QUALITY CHOICE EYE DROPS IRRITATION RELIEF (TETRAHYDROZOLINE HCL, ZINC SULFATE)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1679-2026·2026-04-08

    Philips Azurion 5 M12 X-ray may not start from foot switch

    Philips is recalling the Azurion 5 M12 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Azurion 5 M12; System Code: (1)722227, (2)722231;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1688-2026·2026-04-08

    Stryker surgical light assembly may not support the ceiling cover weight

    Stryker is recalling the CHROMOPHARE Softlit Ring Surgical Light System because the light assembly may not adequately support the weight of the ceiling cover.

    Product
    Stryker CHROMOPHARE Softlit Ring Surgical Light System REF: CH00000001
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0415-2026·2026-04-08

    Rugby and Walgreens lubricant eye drops recalled over sterility assurance

    K.C. Pharmaceuticals is recalling Sterile Eye Drops Soothing Tears, sold as Rugby Lubricating Eye Drops and Walgreens Lubricant Eye Drops, for lack of assurance of sterility.

    Product
    STERILE EYE DROPS SOOTHING TEARS (polyethylene glycol 400 0.4% and propylene glycol 0.3%), 0.5 OZ 0.5 fl oz (15 mL) bottles; a) Rugby LUBRICATING EYE DROPS, Distributed by: Rugby Laboratories, Livonia, MI 48152, NDC 0536-1219-94; b) Walgreens, Lubricant Eye Drops, DISTRIBUTED BY
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1663-2026·2026-04-08

    Philips Allura Xper FD20 X-ray may not start from foot switch

    Philips is recalling the Allura Xper FD20 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    ALLURA Xper FD20; System Code: (1) 722006, (2)722012, (3)722028;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1746-2026·2026-04-08

    MiniMed 740G insulin pump delivery varies with pump height changes

    Medtronic is recalling MiniMed 740G insulin pumps because raising or lowering the pump relative to the infusion site can cause unintended over- or under-delivery of insulin.

    Product
    MiniMed 740G Insulin Pump (MMT-1811, MMT-1812, MMT-1861, MMT-1862)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1704-2026·2026-04-08

    Finesse BTK angioplasty balloon catheter may not meet burst specifications

    The Finesse BTK Multicath injectable angioplasty balloon catheter is being recalled because of the potential for the balloon not to meet burst specifications.

    Product
    Brand Name: Finesse BTK Multicath Product Name: Injectable Angioplasty Balloon Catheter Model/Catalog Number: FS252251502 Product Description: 5 French sheath, 0.014" guidewire compatible over-the-wire injectable angioplasty balloon catheter, balloon diameter 2.5mm, balloon le
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1666-2026·2026-04-08

    Philips Allura Xper FD20 Biplane OR Table X-ray may not start

    Philips is recalling the Allura Xper FD20 Biplane OR Table because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    ALLURA Xper FD20 Biplane OR Table; System Code: (1) 722020, (2)722025;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1671-2026·2026-04-08

    Philips Allura Xper FD20/15 X-ray may not start from foot switch

    Philips is recalling the Allura Xper FD20/15 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD20/15; System Code: 722058;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1748-2026·2026-04-08

    Paradigm insulin pump delivery varies with pump height changes

    Medtronic is recalling Paradigm insulin pumps models MMT-712 and MMT-715 because raising or lowering the pump relative to the infusion site can cause unintended over- or under-delivery of insulin.

    Product
    Paradigm Insulin Pump (MMT-712, MMT-715)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1662-2026·2026-04-08

    Philips Allura Xper FD10/10 X-ray may not start from foot switch

    Philips is recalling the Allura Xper FD10/10 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    ALLURA Xper FD10/10; System Code: (1) 722005, (2)722011, (3)722027;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1700-2026·2026-04-08

    da Vinci tenaculum forceps recalled over frayed or broken pitch cables

    Intuitive Surgical is recalling da Vinci S and Si Tenaculum Forceps Instruments following increased complaints regarding frayed or broken pitch cables on reusable surgical instruments.

    Product
    Brand Name: da Vinci S, Si Tenaculum Forceps Instrument Product Name: da Vinci S, Si Tenaculum Forceps Instrument Model/Catalog Number: 420207 Software Version: N/A Product Description: EndoWrist Instruments or Da Vinci S/Si Reusable instruments, including blunt and sharp end
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1661-2026·2026-04-08

    Philips Allura Xper FD10 X-ray may not start from foot switch

    Philips is recalling the Allura Xper FD10 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    ALLURA Xper FD10; System Code: (1) 722003, (2)722010, (3)722026;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1668-2026·2026-04-08

    Philips Allura Xper FD20/10 X-ray may not start from foot switch

    Philips is recalling the Allura Xper FD20/10 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD20/10; System Code: 722029;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1675-2026·2026-04-08

    Philips Azurion 7 B12 X-ray may not start from foot switch

    Philips is recalling the Azurion 7 B12 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Azurion 7 B12; System Code: (1)722067, (2)722225, (3)722235;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1673-2026·2026-04-08

    Philips Azurion 3 M12 X-ray may not start from foot switch

    Philips is recalling the Azurion 3 M12 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Azurion 3 M12; System Code: (1)722063, (2)722221, (3)722229;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0412-2026·2026-04-08

    Leader ultra lubricating eye drops recalled over sterility assurance failure

    Leader Ultra Lubricating Eye Drops, containing polyethylene glycol 400 and propylene glycol, are being recalled for lack of assurance of sterility.

    Product
    LEADER ULTRA LUBRICATING EYE DROPS — LEADER ULTRA LUBRICATING EYE DROPS (POLYETHYLENE GLYCOL 400, PROPYLENE GLYCOL)
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1669-2026·2026-04-08

    Philips Allura Xper FD20/20 X-ray may not start from foot switch

    Philips is recalling the Allura Xper FD20/20 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Allura Xper FD20/20; System Code: 722038;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1677-2026·2026-04-08

    Philips Azurion 7 M12 X-ray may not start from foot switch

    Philips is recalling the Azurion 7 M12 because X-ray imaging may not be initiated, or may occur intermittently, when using the wired foot switch.

    Product
    Azurion 7 M12; System Code: (1)722078, (2)722223, (3)722233;
    Category
    Medical Device
    Distribution
    Distributed nationwide