Severity 3 (High) recalls have a known hazard but no confirmed illness, injury, or property damage in the source text. The risk is theoretical-but-real: a pathogen pre-emptively pulled from shelves before anyone got sick, an allergen mislabeling on an uncommon allergen, a precautionary correction on a device that hasn't yet malfunctioned in the field. Most allergen recalls land here, as do most preventive food recalls based on routine sampling. You should still stop using the product, but you don't need to panic.

The full rubric is on the methodology page. Severity is computed deterministically from the agency’s own classification plus the source text — no editorial vibes.

1251–1275 of 52929

  • HighFDA (Devices)·Z-1870-2026·2026-04-29

    Soft-Vu Angiographic Catheter Omni Flush Non-Braided Defect Recall

    Angiodynamics is recalling Soft-Vu Angiographic Catheters (Omni Flush, Non-Braided) due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Omni Flush, Non-Braided; SOFT-VU OF 4F X 65CM 035 NB 6SH; Catalog No.: 10732301; Product/UPN No.: H787107323015 (Box), H787107323010 (Pouch); Box Quantity: 10 units;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1933-2026·2026-04-29

    LSL Healthcare Wound Closure Tray Model 7554 Recalled for Non-Sterility

    LSL Healthcare is recalling its Wound Closure Tray (Model 7554) distributed nationwide to Maryland, Illinois, and Minnesota because the kits contained non-sterile Webcol Large Alcohol Prep Pads.

    Product
    LSL Healthcare Wound Closure Tray, Model/Catalog Number: 7554
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1941-2026·2026-04-29

    Diversatek Viper Wire Guided Balloon Dilator Inflation Tag Incorrect

    Diversatek Healthcare is recalling Viper 3-Stage Wire Guided Balloon Dilators because the attached inflation tag may contain an incorrect part number with wrong balloon diameter sizes and inflation pressures.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 18mm-19mm-20mm, REF 1205-20
    Category
    Medical Device
    Distribution
    19 states
  • HighNHTSA·26V273000·2026-04-29

    Newmar Recalls 2026 Freedom Aire Motorhomes for Incorrect Weight Labels

    Newmar is recalling 2026 Freedom Aire motorhomes because the Cargo Carrying Capacity label may display an incorrect weight value, potentially allowing the vehicle to be overloaded.

    Product
    NEWMAR — NEWMAR FREEDOM AIRE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1874-2026·2026-04-29

    AccuVu Angiographic Catheter, Omni Flush, Non-Braided Defect Recall

    Angiodynamics recalls AccuVu Angiographic Catheters due to a manufacturing defect that may prevent guidewires from passing through the catheter hub. The affected devices were distributed worldwide.

    Product
    AccuVu Angiographic Catheter, Omni Flush, Non-Braided, With 21 R/O Markers; ACCU-VU OF 4F X 70CM 035 NB 6SH 21 R/O 1CM; Catalog No.: 13709704; Product/UPN No.: H787137097045 (Box), H787137097040 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1922-2026·2026-04-29

    Beckman Coulter Access Total T4 Calibrator Recalled for Inaccurate Results

    Beckman Coulter is recalling Access Total T4 Calibrator lots because they produce falsely low patient results on DxI 600/800 instruments, potentially leading to unnecessary testing, delayed treatment for thyroid disorders, and incorrect dosing in pregnant patients.

    Product
    Access Total T4 Calibrator, Catalog No. 33805
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1940-2026·2026-04-29

    Diversatek Viper balloon dilator tags may show incorrect inflation parameters

    Diversatek Viper 3-Stage Wire Guided Balloon Dilators are being recalled because the catheter inflation tag may show an incorrect part number with wrong balloon diameters and pressures.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Wire Guided Balloon Dilator, 15mm-16.5mm-18mm, REF 1205-18
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-1904-2026·2026-04-29

    Olympus OER-ELITE Endoscope Reprocessor Connecting Tubes Recall

    Olympus Corporation of the Americas is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2116) because the Version 2 reprocessor connecting tube lock levers may fail prematurely.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2116.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1896-2026·2026-04-29

    Avitene Ultrafoam Microfibrillar Collagen Hemostat Recalled for Foreign Matter

    Davol, Inc. is recalling Avitene Ultrafoam Microfibrillar Collagen Hemostat (Catalog Number 1050030) because the product may contain foreign matter, confirmed to be inspect fragments.

    Product
    Avitene Ultrafoam Microfibrillar Collagen Hemostat - 8cm x 6.25cm x 1cm. Catalog Number: 1050030.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighNHTSA·26V271000·2026-04-29

    Roadtrek recreational vehicle pop-top latches may disengage during transit

    Roadtrek is recalling certain recreational vehicles because the pop-top latch may disengage during transit, causing the pop-top to lift. 312 vehicles are affected.

    Product
    ROADTREK — ROADTREK ZION SLUMBER, WESTFALIA WAVE SL, PLAY+SLUMBER, PLAY SLUMBER
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1929-2026·2026-04-29

    LSL Healthcare Central Line Dressing Change Kit Recalled for Non-Sterility

    LSL Healthcare is recalling its Standard Central Line Dressing Change Kit (Model 2717J) because the included Webcol Large Alcohol Prep Pads were found to be non-sterile.

    Product
    LSL Healthcare, Standard Central Line Dressing Change Kit, Model/Catalog Number: 2717J
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0674-2026·2026-04-29

    El Mexicano agua fresca de horchata contains undeclared milk

    EL MEXICANO agua fresca de horchata Instant Horchata Drink is being recalled because of undeclared milk. The action covers 405,136 packages distributed across a large number of states.

    Product
    EL MEXICANO agua fresca de horchata Instant Horchata Drink NET WT 12oz (340g) INGREDIENTS: *** MILK SUBSTITUTE (WHEY *** LACTOSE *** DISTRIBUTED BY MARQUEZ BROTHERS INTERNATIONAL, INC. San Jose CA 95138 UPC: 042743190204 Item: 102279
    Category
    Food
    Distribution
    29 states
  • HighFDA (Devices)·Z-1872-2026·2026-04-29

    AccuVu Angiographic Catheter recall due to manufacturing defect

    Angiodynamics is recalling AccuVu Angiographic Catheters due to a manufacturing defect that may prevent a guidewire from passing through the catheter hub. The defect could interfere with proper device function during medical procedures.

    Product
    AccuVu Angiographic Catheter, Omni Flush, Non-Braided, With 2 R/O Markers; ACCU-VU OF 4F X 70CM 035 NB 6SH 2 R/O 2CM; Catalog No.: 13709005; Product/UPN No.: H787137090055 (Box), H787137090050 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1866-2026·2026-04-29

    Angiodynamics Soft-Vu Angiographic Catheter Guidewire Blockage Risk

    Angiodynamics is recalling the Soft-Vu Angiographic Catheter, Kumpe, Non-Braided due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft-Vu Angiographic Catheter, Kumpe, Non-Braided; SOFT-VU KMP 4F X 100CM 038 NB 0SH; Catalog No.: 10714021; Product/UPN No.: H787107140215 (Box), H787107140210 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1907-2026·2026-04-29

    OER-ELITE Endoscope Reprocessor Connecting Tubes Lock Failure Recall

    Olympus Corporation of the Americas is recalling OER-ELITE Endoscope Reprocessor Connecting Tubes (Model MAJ-2119) due to potential premature failure of the Version 2 reprocessor connecting tube lock levers.

    Product
    OER-ELITE Endoscope Reprocessor Connecting Tubes. Model/Catalog Number: MAJ-2119.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1853-2026·2026-04-29

    Olympus Thunderbeat II shears 35 cm may shed a distal tip component

    Olympus is recalling Thunderbeat II Shears with Ultrasonic Mode, 5 mm and 35 cm, because a distal tip component may detach during use. 3,360 units are affected.

    Product
    Olympus Thunderbeat II Shears w/Ultrasonic Mode, 5mm, 35cm. Model Number: TB2-0535FC.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1857-2026·2026-04-29

    Soft-Vu Angiographic Catheter Kumpe Non-Braided manufacturing defect recall

    Angiodynamics is recalling Soft-Vu Angiographic Catheter Kumpe units due to a manufacturing defect that may prevent guidewires from passing through the catheter hub.

    Product
    Soft -Vu Angiographic Catheter, Kumpe, Non-Braided; SOFT-VU KMP 4F X 40CM 038 NB 0SH; Catalog No.: 10710013; Product/UPN No.: H787107100135 (Box), H787107100130 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1863-2026·2026-04-29

    Soft-Vu Angiographic Catheter Berenstein Non-Braided Device Recall

    Angiodynamics is recalling Soft-Vu Angiographic Catheters (Berenstein, Non-Braided) due to a manufacturing defect that may prevent the guidewire from passing through the catheter hub. The defect affects 1,030 units distributed worldwide.

    Product
    Soft-Vu Angiographic Catheter, Berenstein, Non-Braided; SOFT-VU BER 4F X 100CM 038 NB 0SH; Catalog No.: 10714016; Product/UPN No.: H787107140165 (Box), H787107140160 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1877-2026·2026-04-29

    Medline Convenience Kits With Syringes Recalled for Unapproved Design Changes

    Medline Industries is recalling Convenience Kits containing 10mL polycarbonate colored syringes due to unapproved design changes made outside of FDA 510(k) clearance. The recall affects 270,311 units distributed nationwide and internationally.

    Product
    Medline Convenience Kits containing select SKUs of 10mL Polycarbonate Colored Syringes ADULT CATH PACK-LF DYNJ38395G ANGIO DRAPE PACK (ADLUG)642-LF DYNJ47665F DYNJ47665G ANGIO KIT PACK DYNJ83746 DYNJ83746A ANGIO PACK DYNJ30565G DYNJ51239C DYNJ66631A DYNJ6920
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1875-2026·2026-04-29

    AccuVu Angiographic Catheter recalled for guidewire passage defect

    Angiodynamics is recalling the AccuVu Angiographic Catheter (Pigtail, Non-Braided) due to a manufacturing defect that may prevent a properly sized guidewire from passing through the catheter hub's inner diameter.

    Product
    AccuVu Angiographic Catheter, Pigtail, Non-Braided, With 21 R/O Markers; ACCU-VU PT 4F X 70CM 035 NB 10SH 21 R/O 1CM; Catalog No.: 13709804; Product/UPN No.: H787137098045 (Box), H787137098040 (Pouch); Box Quantity: 5 pouches;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0671-2026·2026-04-29

    Spice powder recalled after lead level exceeded the New York standard

    A 4 oz spice powder is being recalled because its lead level was higher than the New York State Department of Agriculture and Markets standard. 20 cases are affected.

    Product
    Spice Powder, 4 oz, Plastic Bag
    Category
    Food
    Distribution
    8 states
  • HighFDA (Devices)·Z-1854-2026·2026-04-29

    Olympus Thunderbeat II Shears Ultrasonic Mode distal tip detachment risk

    Olympus is recalling Thunderbeat II Shears (5mm, 45cm) because the distal tip component may detach during use, potentially causing patient harm.

    Product
    Olympus Thunderbeat II Shears w/Ultrasonic Mode, 5mm, 45cm. Model Number: TB2-0545FC.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1851-2026·2026-04-29

    Olympus Thunderbeat II Shears recall due to distal tip detachment

    Olympus Corporation of the Americas is recalling Olympus Thunderbeat II Shears (Model TB2-0520FC) because the distal tip component may detach during use.

    Product
    Olympus Thunderbeat II Shears w/Ultrasonic Mode, 5mm, 20cm. Model Number: TB2-0520FC.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1894-2026·2026-04-29

    LeadCare Plus Blood Lead Test Kit Recalled for Unexpectedly Elevated Results

    Magellan Diagnostics is recalling LeadCare Plus Blood Lead Test Kits (Catalog Number 82-0004) because they may produce falsely elevated lead results when used with certain third-party micro-collection devices, potentially causing delayed testing and unnecessary follow-up testing.

    Product
    LeadCare¿ Plus Blood Lead Test Kit; Catalog Number: 82-0004; The LeadCare¿ Plus kit is provided with the following materials: " Sensors (4 containers of 24 each; 96 tests) " Treatment Reagent Tubes (4 packages of 24 each; 96 tests) " Calibration Button (1 @) " Lead Contro
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1938-2026·2026-04-29

    Diversatek Healthcare Viper Balloon Dilator Inflation Tag Labeling Error

    Diversatek Healthcare is recalling Viper 3-Stage Fixed Wire Balloon Dilators because the catheter inflation tag may contain incorrect part numbers and balloon diameter and pressure specifications.

    Product
    Diversatek Healthcare Viper¿ 3-Stage Fixed Wire Balloon Dilator, 6mm-7mm-8mm, REF 1204-08
    Category
    Medical Device
    Distribution
    19 states