The Recall Desk

Severity 3 of 5

High recalls

Real risk of harm even if no illness or injury has been reported yet. Stop using the product and follow the agency's guidance.

What “high” means here

Severity 3 (High) recalls have a known hazard but no confirmed illness, injury, or property damage in the source text. The risk is theoretical-but-real: a pathogen pre-emptively pulled from shelves before anyone got sick, an allergen mislabeling on an uncommon allergen, a precautionary correction on a device that hasn't yet malfunctioned in the field. Most allergen recalls land here, as do most preventive food recalls based on routine sampling. You should still stop using the product, but you don't need to panic.

The full rubric is on the methodology page. Severity is computed deterministically from the agency’s own classification plus the source text — no editorial vibes.

28851–28875 of 50488

  • HighFDA (Devices)·Z-1704-2018·2018-05-16

    DePuy Recalls ATTUNE Revision Knee Implant Due to Burrs

    DePuy Orthopaedics is recalling a specific femoral revision implant because burrs may be present on the extraction hole threads.

    Product
    ATTUNE Revision CRS Femoral RT SZ 5 Cemented, Catalog No. 150440205, Femoral Revision Implant, Knee
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-1775-2018·2018-05-16

    ICU Medical Recalls Hemodynamic Monitoring Systems Due to Pause Mode Defect

    ICU Medical is recalling 36 hemodynamic monitoring systems because the catheter thermal coil may continue operating while in Pause mode.

    Product
    Hemodynamic monitoring system (HMS), comprised of a Patient Interface Module (Part Number 58401-000 and a User Interface Module (Part Number 58403-000). Intended for patients for whom the monitoring of continuous cardiac output is indicated for diagnostic and prognostic…
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-1737-2018·2018-05-16

    Zimmer Biomet Recalls Gentle Threads Interference Screws Due to Sterilization Error

    Zimmer Biomet is recalling 54 Gentle Threads Interference Screws because overexposure to ethylene oxide sterilization may compromise the sterile barrier, increasing infection risk.

    Product
    Gentle Threads, Interference Screw; Model No. 905607, for soft tissue reattachment procedures in the ankle/foot and knee.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1796-2018·2018-05-16

    Siemens Recalls Dimension Lipase Flex Reagent Cartridge Lot FB8109

    Siemens Healthcare Diagnostics is recalling one lot of Dimension Lipase Flex Reagent Cartridges due to calibration failure causing positive bias in test results.

    Product
    Dimension Lipase Flex¿ Reagent Cartridge - ( Lipase-esterase, enzymatic, photometric, lipase)
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1694-2018·2018-05-16

    Straumann Emdogain Recall Due to Shelf Life Data Issue

    Straumann Manufacturing is recalling specific lots of Emdogain because a raw material shelf life change was made without data proving the product remains effective.

    Product
    Straumann¿ Emdogain 015, USA. Enamel Matrix Derivative. Article Number 075.099
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1789-2018·2018-05-16

    TP Orthodontics Recalls Jasper Vektor Class II Correction Appliances

    TP Orthodontics is recalling 7 Jasper Vektor Class II Correction Appliances because the devices may break in the patient's mouth, posing a risk of injury.

    Product
    Jasper Vektor, Class II Correction Appliance, Part No. 610-530L used for correcting class 2 malocclusions by applying light forces on the teeth using a tube, arch wire and stops.
    Category
    Medical Device
    Distribution
    20 states
  • HighFDA (Devices)·Z-1672-2018·2018-05-16

    Siemens Recalls Dimension Vista MMB Reagent Cartridges Due to Biotin Interference

    Siemens Healthcare Diagnostics is recalling specific lots of Dimension Vista Mass Creatine Kinase (MMB) Flex reagent cartridges because the instructions for use do not list the biotin concentration that causes interference.

    Product
    Dimension Vista¿ Mass Creatine Kinase (MMB) Flex¿ reagent cartridge
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1798-2018·2018-05-16

    Inpeco Laboratory Automation Systems Recalled for Module Freezing Risk

    Inpeco S.A. is recalling 18 laboratory automation systems because a module may freeze without warning, potentially delaying patient test results.

    Product
    FlexLab (FLX), Accelerator a3600 (ACP), Aptio Automation (AP2), Laboratory Automation System
    Category
    Medical Device
    Distribution
    2 states
  • HighNHTSA·18V325000·2018-05-16

    Audi Recalls S5 Cabriolet Vehicles Due to Air Bag Installation Defect

    Volkswagen Group of America is recalling 2018 Audi S5 Cabriolet vehicles because the front passenger seat-mounted air bag may have been folded incorrectly, increasing injury risk in a crash.

    Product
    AUDI — AUDI S5 CABRIOLET
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1732-2018·2018-05-16

    Datascope Recalls Custom Tubing Kits Due to Seal Separation Risk

    Datascope Corporation is recalling four custom tubing kits because a seal defect may allow air to enter the housing, potentially collapsing the balloon and reducing blood flow.

    Product
    BO-TOP 20700 SMALL PATIENT 3/8, Custom Tubing Kit, Catalog No. 701050966
    Category
    Medical Device
    Distribution
    13 states
  • HighFDA (Devices)·Z-1687-2018·2018-05-16

    Siemens Recalls ADVIA Centaur Cyclosporine Due to Labeling Error

    Siemens Healthcare Diagnostics is recalling ADVIA Centaur Cyclosporine because the instructions for use incorrectly state the biotin non-interference level.

    Product
    ADVIA Centaur¿ Cyclosporine
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0790-2018·2018-05-16

    Kroger Recalls Capecitabine Tablets Due to Lack of Processing Controls

    Kroger Specialty Pharmacy is recalling one lot of Capecitabine 150 mg tablets because the product lacks required processing controls. The recall affects units dispensed in Mississippi, Louisiana, Arkansas, Illinois, and Florida.

    Product
    Capecitabine 150 mg Tablet NDC 00378-2511-91 28 days supply
    Category
    Drug
    Distribution
    5 states
  • HighFDA (Drugs)·D-0747-2018·2018-05-16

    Kroger Recalls Botox Due to Lack of Processing Controls

    Kroger Specialty Pharmacy is recalling Botox 100 Units Vials because of a lack of processing controls. The product was distributed in MS, LA, AR, IL, and FL.

    Product
    Botox 100 Units Vial NDC 00023-1145-01 90 days supply.
    Category
    Drug
    Distribution
    5 states
  • HighFDA (Devices)·Z-1634-2018·2018-05-16

    Vygon Recalls Neonatal PICC Trays Due to Potential Sterility Issues

    Vygon U.S.A. is recalling 16,520 Neonatal PICC Trays because potential friction holes may affect the product's sterility.

    Product
    Neonatal PICC Tray, Product Code: AMS-8010CP-1 Convenience kit for the insertion of PICCs into the vascular system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighUSDA FSIS·038-2018·2018-05-16

    Kent Quality Foods Recalls Hot Dogs and Sausages for Undeclared Soy

    Kent Quality Foods is recalling approximately 308,430 pounds of hot dog and sausage products because they contain undeclared soy, a known allergen.

    Product
    Kent Quality Foods Inc. — Kent Quality Foods, Inc. Recalls Hot Dog and Sausage Products Due to Misbranding and an Undeclared Allergen
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1751-2018·2018-05-16

    Cook Inc. Recalls Connecting Tubes Due to Potential Leakage

    Cook Inc. is recalling 220 connecting tubes because the cap-adapter assembly may not be adequately tightened, potentially leading to fluid leakage or air aspiration.

    Product
    Connecting Tube - Female to Male Luer Lock, HPCT8.8-60-M-FM Product Usage: The connecting tube is intended to be a conduit between a fluid reservoir and a vascular catheter in the patient. The connecting tube may be used during angiographic procedures to connect radiographic…
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-1663-2018·2018-05-16

    Baxter Sigma Spectrum Infusion Pump Recalled for Documentation Errors

    Baxter Healthcare is recalling 444 Sigma Spectrum Infusion Pumps because technicians omitted required safety tests, potentially compromising air and occlusion detection.

    Product
    Baxter Sigma Spectrum Infusion Pump with master Drug Library (Version 6) 35700BAX Product Usage: The Baxter Sigma Spectrum Infusion Pump with master Drug Library is intended to be used for the controlled administration of fluids. These fluids may includes pharmaceutical…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1702-2018·2018-05-16

    Bard BrachySource Iodine-125 Radioactive Seeds Recalled for Dosage Mix-Up

    Bard Brachytherapy is recalling Iodine-125 radioactive seeds because incorrect dosage levels were mixed up and sent to two hospitals in California and Georgia.

    Product
    BARD¿ BrachySource¿ Iodine125 radioactive seeds consist of a welded titanium capsule containing the I125 absorbed onto a nickel / copper-coated, gold-cored aluminum wire (reference Figure 1 below). The I125 has a half-life of 59.6 days and decays by electron capture with the…
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-1762-2018·2018-05-16

    Bard Peripheral Vascular Recalls POWERPORT ClearVUE Catheters Due to Incorrect Instructions

    Bard Peripheral Vascular Inc is recalling 1551 units of the POWERPORT ClearVUE Slim catheter because the included Patient ID Card has incorrect port flushing instructions.

    Product
    POWERPORT ClearVUE Slim with Smooth Septum, 6F ChronoFlex Silk, Polyurethane Catheter, REF 1676300
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0800-2018·2018-05-16

    Kroger Recalls Lupron Depot Due to Lack of Processing Controls

    Kroger Specialty Pharmacy is recalling Lupron Depot 22.5 mg 3 month Kits due to a lack of processing controls. The recall affects lots dispensed in MS, LA, AR, IL, and FL between December 2017 and February 2018.

    Product
    Lupron Depot 22.5 mg 3 month Kit NDC 00074-3346-03 84 days supply
    Category
    Drug
    Distribution
    5 states
  • HighFDA (Drugs)·D-0733-2018·2018-05-16

    Vitalab Pharmacy Recalls Sterile Injectable Drugs Due to Sterility Concerns

    Vitalab Pharmacy is recalling specific lots of sterile injectable drugs because airflow patterns may not support aseptic production.

    Product
    Papaverine 30mg/Phentolamine 2mg/Prostaglandin 20mcg/mL, Papaverine 30mg/Phentolamine 1mg/Prostaglandin 10mcg/mL, Papaverine 30mg/Phentolamine 1mg/Prostaglandin 25mcg/mL, sterile injectables, Vitalab Pharmacy, Inc
    Category
    Drug
    Distribution
    0 states
  • HighFDA (Devices)·Z-1664-2018·2018-05-16

    Baxter Sigma Spectrum Infusion Pump Recall Due to Testing Documentation Errors

    Baxter is recalling 444 Sigma Spectrum Infusion Pumps because technicians omitted specific safety tests. The missing tests for air and occlusion detection could lead to serious health consequences.

    Product
    Baxter Sigma Spectrum Infusion Pump with master Drug Library (Version 6) 35700BAXL Product Usage: The Baxter Sigma Spectrum Infusion Pump with master Drug Library is intended to be used for the controlled administration of fluids. These fluids may includes pharmaceutical…
    Category
    Medical Device
    Distribution
    Distributed nationwide