The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

21651–21675 of 114376

  • HighFDA (Food)·F-1319-2023·2023-08-09

    Roasted Peanuts Recalled for Undeclared Tree Nuts, Peanuts, and Wheat

    Houston Pecan Company is recalling roasted peanuts purchased before May 25, 2023, for undeclared allergen cross-contamination with tree nuts, peanuts, and wheat. The products were sold in Texas and through internet sales.

    Product
    Granulated Peanuts Roasted packaged in 5 pound bags; Virginia Peanuts Roasted NO SALT packaged in 5 pound bags; Spanish Peanuts Roasted & Salted packaged in 5 pound bags;
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-1339-2023·2023-08-09

    Black Mission Figs Recalled for Undeclared Tree Nuts, Peanuts, Wheat

    Houston Pecan Company is recalling Black Mission Figs in 5-pound bags distributed in Texas and via internet due to undeclared tree nuts, peanuts, and wheat from allergen cross-contamination.

    Product
    Black Mission Figs Potassium Sorbate packaged in 5 pound bags
    Category
    Food
    Distribution
    1 state
  • HighFDA (Drugs)·D-1048-2023·2023-08-09

    Vecuronium Injection Recalled Due to Lack of Sterility Validation

    Vecuronium injection syringes were recalled nationwide due to lack of validation data for sanitization cycles, which raises sterility assurance concerns.

    Product
    vecuronium, 10 mg/10mL, (1 mg/mL), 10 mL syringe, Rx only, PARALYZING AGENT, CAPS, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC: 71286-6012-1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1076-2023·2023-08-09

    Rocuronium Syringes Recalled for Lack of Sterility Validation

    Central Admixture Pharmacy Services is recalling rocuronium syringes due to lack of validation data for sanitization cycles, which cannot assure sterility. The recall affects 10,065 syringes distributed nationwide.

    Product
    rocuronium, 50 mg /5 mL, (10 mg/mL), 5 mL Syringe, Rx only, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC: 71286-6010-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1041-2023·2023-08-09

    FDA Recalls Cardioplegia Solution for Lacking Sterility Validation Data

    Central Admixture Pharmacy Services is recalling a cardioplegia solution used during heart surgery due to insufficient validation data for sterilization cycles. The 104-bag recall covers products distributed nationwide.

    Product
    CARDIOPLEGIA SOLUTION, 24 mEq K, Maintenance 8:1 non-enriched, Low Potassium, IV Bag, Total Volume = 300 mL, RX only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC 72196-0215-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2260-2023·2023-08-09

    Philips Incisive CT Scanner Mounting Box Poses Injury Risk

    A metal mounting box in the Incisive CT Power scanner may detach and potentially injure operators or cause system failure. Philips is recalling 53 affected units distributed worldwide.

    Product
    Incisive CT Power (China)-Computed Tomography X-Ray System Model: 728148
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0951-2023·2023-08-09

    FDA recalls dilTIAZem IV bags due to sterility assurance concerns

    Central Admixture Pharmacy Services is recalling 2,260 dilTIAZem IV bags nationwide because validation data for the decontamination process is lacking. Affected lots expire between July and August 2023.

    Product
    dilTIAZem 125mg/125mL (1 mg/mL), added to dextrose 5%, IV Bag, RX only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Phoenix, AZ 85043, NDC: 72196-6054-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0983-2023·2023-08-09

    FDA Recalls Oxytocin IV Bags Due to Sterility Assurance Concerns

    Central Admixture Pharmacy Services is recalling 463 bags of oxytocin IV solution nationwide due to inadequate validation data for sterilization processes. The product may not meet FDA sterility standards required for injectable medications.

    Product
    oxyTOCIN, 20 units added to dextrose 5%/lactated ringers 1000 mL, IV Bag, Rx Only, This drug was repacked by CAPS, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-6031-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1072-2023·2023-08-09

    Fentanyl-bupivacaine injectable drug recalled due to sterility concerns

    Central Admixture Pharmacy Services is recalling 896 bags of fentanyl-bupivacaine injectable solution nationwide due to lack of sterility assurance. The FDA Class II recall affects compounded pain medication lacking adequate sterilization validation.

    Product
    fentaNYL 2 mcg/mL and bupivacaine 0.125% PF in 0.9% sodium chloride / Total Volume = 250 mL, Total fentaNYL 500 mcg/250 mL, bag, Rx only, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC 71286-2082-2
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1025-2023·2023-08-09

    Cardioplegia Solution Recalled Due to Sterility Assurance Deficiency

    Central Admixture Pharmacy Services recalls Leesburg Cardioplegia Solution due to inadequate sterilization validation. The recall affects 36 bags distributed nationwide.

    Product
    CARDIOPLEGIA SOLUTION, LEESBURG CARDIOPLEGIA, IV Bag, Total Volume = 1030.2 mL, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-0218-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2252-2023·2023-08-09

    Fusion Lithotripsy Extraction Baskets recalled for mechanical defects

    Wilson-Cook Medical's Fusion Lithotripsy Extraction Baskets are being recalled due to mechanical defects that can prevent the basket from advancing or retracting, or cause the drive wire to break or separate during use.

    Product
    Fusion Lithotripsy Extraction Basket, Model Number FS-LXB-2X4 G48277; Fusion Lithotripsy Extraction Baskets are intended to be used for endoscopic removal of biliary stones and foreign bodies.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Drugs)·D-1007-2023·2023-08-09

    Neonatal TPN Starter Bag Recalled Due to Sterility Assurance Issues

    Central Admixture Pharmacy Services is recalling a neonatal IV nutrition bag due to lack of sterility assurance. The recall affects 156 bags of the product distributed nationwide.

    Product
    Neonatal TPN Starter Bag, Amino Acids (trophamine) 3.5%/Dextrose 10% with CALCIUM, total volume = 250mL, IV Bag, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043,NDC: 72196-0407-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1069-2023·2023-08-09

    Injectable Fentanyl-Bupivacaine Mixture Recalled for Sterility Validation Failure

    Central Admixture Pharmacy Services recalls 295 bags of injectable fentanyl-bupivacaine solution nationwide because the sterilization process lacked proper validation documentation.

    Product
    fentaNYL 2 mcg/mL and bupivacaine 0.0625% PF in 0.9% sodium chloride, Total Volume = 250 mL, Total fentaNYL 500 mcg/250 mL, 250 mL bag, Rx only, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC 71286-2081-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1070-2023·2023-08-09

    Fentanyl and Bupivacaine Injectable Recalled for Sterility Concerns

    Central Admixture Pharmacy Services is recalling 1,114 bags of fentanyl and bupivacaine injectable due to lack of validation data for sterilization. The product was distributed nationwide.

    Product
    fentaNYL 2 mcg/mL and bupivacaine 0.125% PF in 0.9% sodium chloride, Total Volume = 100 mL, Total FentaNYL 200 mcg/100 mL, 100 mL bag, Rx only, CAPS, Central Admixture Pharmacy Services, Inc., 7935 Dunbrook Road, Suite C, San Diego, CA 92126, NDC 71286-2082-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0957-2023·2023-08-09

    Epinephrine IV Bags Recalled Due to Unvalidated Sterility Process

    Central Admixture Pharmacy Services is recalling 333 units of epinephrine 2 mg in dextrose 5% IV bags because validation data for sterilization procedures is lacking, raising concerns about product sterility assurance.

    Product
    EPINEPHrine, 2 mg added to dextrose 5% 250mL, Concentration = 8 mcg/mL, IV Bag, Rx Only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Phoenix, AZ 85043, NDC: 72196-6030-1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1315-2023·2023-08-09

    Walnuts Recalled for Undeclared Tree Nuts, Peanuts, and Wheat Allergens

    Houston Pecan Company is recalling 5-pound bags of walnuts that may contain undeclared tree nuts, peanuts, and wheat due to cross-contamination. Affected products were sold in Texas and through internet sales.

    Product
    Walnut Halves packaged in 5 pound bag; Walnuts Medium Pices packaged in 5 pound bags; Walnuts Halves & Large Pieces packaged in 5 pound bags
    Category
    Food
    Distribution
    1 state
  • HighFDA (Drugs)·D-0980-2023·2023-08-09

    Neonatal TPN Starter Bags Recalled Due to Sterility Validation Concerns

    Central Admixture Pharmacy Services recalled 52 neonatal TPN starter bags nationwide due to lack of validation data for sterilization processes, raising concerns about sterility assurance.

    Product
    Neonatal TPN Starter Bag, Amino Acids (trophamine) 6%/Dextrose 10% with low calcium and HEPARIN, IV Bag, Total Volume = 250mL, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-0430-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0993-2023·2023-08-09

    Neonatal IV Nutrition Bags Recalled Due to Sterility Assurance Defect

    Central Admixture Pharmacy Services is recalling 188 neonatal TPN bags nationwide because sterility assurance cannot be guaranteed. Validation data for decontamination cycles is lacking.

    Product
    Neonatal TPN Starter Bag, Amino Acids (trophamine) 2%/Dextrose 10% with CALCIUM and HEPARIN, total volume = 250mL, IV Bag, Rx only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-0416-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-1024-2023·2023-08-09

    Cardioplegia solution IV bags recalled for lack of sterility assurance

    Central Admixture Pharmacy Services is recalling 308 bags of cardioplegia solution nationwide due to lack of assurance of sterility and insufficient validation data for decontamination cycles.

    Product
    CARDIOPLEGIA SOLUTION, 48 mEq K, Induction 4:1 in Ringer's, High Potassium, IV Bag, total volume = 522.8 mL, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC: 72196-0206-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0961-2023·2023-08-09

    Phenylepherine IV bags recalled due to sterility assurance concerns

    Central Admixture Pharmacy Services is recalling over 8,300 phenylepherine IV bags nationwide because sterilization procedures were not adequately validated. Sterility cannot be assured for the affected units.

    Product
    PHENYLephrine 20mg/250ml added to 0.9% sodium chloride, IV Bag, Rx Only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Phoenix, AZ 85043, NDC: 72196-7025-1.
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Drugs)·D-0988-2023·2023-08-09

    Norepinephrine IV bags recalled for sterility validation deficiency

    Central Admixture Pharmacy Services recalled 80 bags of norepinephrine IV solution due to lack of sterility assurance and insufficient validation data for decontamination cycles. Product was distributed nationwide.

    Product
    norepinephrine, 16 mg, added to dextrose 5% 250 mL, IV Bag, CONCENTRATION 64 mcg/mL, Rx Only, Central Admixture Pharmacy Services, Inc., 2200 South 43rd Avenue, Pheonix, AZ 85043, NDC 72196-8095-1
    Category
    Drug
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2291-2023·2023-08-09

    Medline Anesthesia Procedural Kits Recalled for Potential Sterility Failure

    Medline Industries recalls 1,130 anesthesia procedural kits over concerns that the sterile ultrasound gel component may not meet sterility specifications. The kits were distributed worldwide including the US from April 2020 to April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. ANESTHESIA CVL KIT-LF, Model Number: DYNJ52283C; b. ANESTHESIA OH TOTE, Model Number: DYNJ61476;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2298-2023·2023-08-09

    Medical procedural kits recalled due to sterility concerns with ultrasound gel

    Medline recalls 76,870 procedural kits because the ultrasound gel component may not meet sterility standards. Kits were distributed nationwide and internationally from April 2020 through April 2023.

    Product
    Custom Sterile and Non-Sterile Procedural Kits containing Turkuaz Ultrasound Gel. Labeled as the following: a. CRMC MINOR IR PROCEDURE PK-LF, Model Numbers: DYNJ61099B, DYNJ61099C; b. CRMC TUNNEL CATH TRAY-LF, Model Numbers: DYNJ61118C, DYNJ61118F; c. CUSTOM ANGIO TRAY…
    Category
    Medical Device
    Distribution
    Distributed nationwide