The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

5876–5900 of 114914

  • HighFDA (Devices)·Z-0971-2026·2025-12-31

    Femoral nails, 400 mm right trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 23 Affixus Antegrade Femoral Nails, model 815509400, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815509400 Software Version: N/A Product Description: Affixus 9 mm, Length 400 mm, Right, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0972-2026·2025-12-31

    Femoral nails, 420 mm right trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 22 Affixus Antegrade Femoral Nails, model 815509420, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815509420 Software Version: N/A Product Description: Affixus 9 mm, Length 420 mm, Right, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0962-2026·2025-12-31

    Medication dispensing cabinets recalled after a firmware update caused drawer failures

    CareFusion 303 is recalling 53,669 BD Pyxis automated dispensing cabinet units after a drawer firmware update caused a duplicate address error and drawer failure.

    Product
    BD Pyxis MedStation ES, REF: 323, BD Pyxis MedStation ES 7 Drawer Auxiliary, REF: 324, BD Pyxis MedStation ES Tower, REF: 352, BD Pyxis Pro 7-Drawer Auxiliary, REF: 1149-00, BD Pyxis Pro 7- Drawer Auxiliary with Secure Tower, REF: 1152-00, BD Pyxis Pro MedStation…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0976-2026·2025-12-31

    Femoral nails, 340 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 24 Affixus Antegrade Femoral Nails, model 815609340, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609340 Software Version: N/A Product Description: Affixus 9 mm, Length 340 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0979-2026·2025-12-31

    Femoral nails, 400 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 24 Affixus Antegrade Femoral Nails, model 815609400, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609400 Software Version: N/A Product Description: Affixus 9 mm, Length 400 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0980-2026·2025-12-31

    Femoral nails, 420 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 23 Affixus Antegrade Femoral Nails, model 815609420, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609420 Software Version: N/A Product Description: Affixus 9 mm, Length 420 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0326-2026·2025-12-31

    Tomato basil soup recalled over undeclared milk in 110 cases

    Lil Turtles is recalling 110 cases of Grandma Belle's Tomato Basil Soup over undeclared milk.

    Product
    Grandma Belle's Tomato Basil Soup, Net Wt. 17 oz. (482g), packaged in a glass jar, UPC 810084612293, Made By: Lil' Turtles 504 North Ray Street, Baltic, Ohio 43804, packed 12 jars per case
    Category
    Food
    Distribution
    14 states
  • HighFDA (Devices)·Z-0992-2026·2025-12-31

    Dialysis concentrate 100425 recalled because safety and efficacy cannot be assured

    Diasol is recalling 2200 gallons of liquid concentrate for bicarbonate dialysis, product 100425-10-DEX100, because the safety and efficacy of the dialysis acid concentrate cannot be assured.

    Product
    Brand Name: Diasol Product Name: 100425-10-DEX100, Liquid Concentrate for Bicarbonate Dialysis Non Pyrogenic, 2K, 3.0CA, 1.0MG, 208.2 liters
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0975-2026·2025-12-31

    Femoral nails, 320 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 23 Affixus Antegrade Femoral Nails, model 815609320, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609320 Software Version: N/A Product Description: Affixus 9 mm, Length 320 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0970-2026·2025-12-31

    Femoral nails, 380 mm right trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 23 Affixus Antegrade Femoral Nails, model 815509380, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815509380 Software Version: N/A Product Description: Affixus 9 mm, Length 380 mm, Right, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0964-2026·2025-12-31

    Surgical robot console motors recalled over an error that locks ergonomics

    Intuitive Surgical is recalling 144 da Vinci 5 Surgeon Console Column Motor Connectors because a connector fault triggers Error 23062 and locks console ergonomics until the motor is replaced.

    Product
    da Vinci 5, Surgeon Console Column Motor Connector; ASSY,DV5 CONSOLE,SSC,IS5000; Part Number: 380730-40
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0996-2026·2025-12-31

    Femoral nails, 360 mm left trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 24 Affixus Antegrade Femoral Nails, model 815609360, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Restore Clinician Programmer Application (CP App), Model A71100 used with the following programmers: CT900A PROG CT900A CLINICIAN TABLET US CT900B PROG CT900B CLINICIAN TABLET EU -UK CT900C PROG CT900C CLINICIAN TABLET UK CT900D PROG CT900D CLINICIAN TABLET GLOBAL CT900E…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0923-2026·2025-12-31

    Digital radiography systems recalled over exceeding the maximum air kerma rate

    AGFA Healthcare is recalling 35 DR 800 X-ray systems because it is possible to exceed the maximum allowed air kerma rate of 88mGy/min for pulsed fluoroscopy exams.

    Product
    Brand name: AGFA Digital Radiography X- Ray system DR 800 with MUSICA Dynamic Common Name: DR 800
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0988-2026·2025-12-31

    Dialysis concentrate 100125 recalled because safety and efficacy cannot be assured

    Diasol is recalling 7,200 gallons of liquid concentrate for bicarbonate dialysis, product 100125-10-DEX100, because the safety and efficacy of the dialysis acid concentrate cannot be assured.

    Product
    Brand Name: Diasol Product Name: 100125-10-DEX100, Liquid Concentrate for Bicarbonate Dialysis Non Pyrogenic, 2K, 3.0CA, 1.0MG, 208.2 liters
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Food)·H-0330-2026·2025-12-31

    Coffee cake recalled after maple walnut was labeled as raspberry

    The James Skinner LLC is recalling 811 cases of Publix Raspberry Coffee Cake because Maple Walnut Coffee Cake was incorrectly labeled as Raspberry and walnuts were not declared.

    Product
    Publix Raspberry Coffee Cake, Net Wt. 15 oz. (425g), packaged in an aluminum foil tray and clear plastic clamshell lid with wraparound label, UPC 0-41415-54691-2, Distributed By Publix Supermarkets, Inc. Lakeland, FL 33802, packed 12 per case Case label reads, in part: Maple…
    Category
    Food
    Distribution
    1 state
  • HighFDA (Devices)·Z-0977-2026·2025-12-31

    Neurostimulator programmer app recalled over a device reset message that persisted

    Medtronic Neuromodulation is recalling 7,667 Restore Clinician Programmer Application devices after a Device Reset message could not be cleared, in rare cases preventing therapy from resuming.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815609360 Software Version: N/A Product Description: Affixus 9 mm, Length 360 mm, Left, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0983-2026·2025-12-31

    Femoral nails, 300 mm right trochanteric, recalled over undersized shaft diameter

    Zimmer is recalling 11 Affixus Antegrade Femoral Nails, model 815509300, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815509300 Software Version: N/A Product Description: Affixus 9 mm, Length 300 mm, Right, Trochanteric Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0982-2026·2025-12-31

    Femoral nails, 280 mm left piriformis, recalled over undersized shaft diameter

    Zimmer is recalling 3 Affixus Antegrade Femoral Nails, model 815809280, because an undersized distal shaft diameter could lead to implant fatigue fracture.

    Product
    Brand Name: Affixus Antegrade Femoral Nailing System Product Name: Affixus Antegrade Femoral Nails Model/Catalog Number: 815809280 Software Version: N/A Product Description: Affixus 9 mm, Length 280 mm, Left, Priformis Nail Component: N/A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0997-2026·2025-12-31

    Bicarbonate reagent recalled over falsely high results from LDH interference

    Beckman Coulter is recalling 36,981 bicarbonate reagents because they may generate falsely high bicarbonate results due to interference with lactate dehydrogenase in the sample.

    Product
    BECKMAN COULTER BICARBONATE REF: OSR6137 OSR6237 OSR6637 OSR6x37 Bicarbonate is a system reagent for the quantitative determination of Bicarbonate in human serum and plasma on Beckman Coulter AU analyzers.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0990-2026·2025-12-31

    Dialysis concentrate 100230 recalled because safety and efficacy cannot be assured

    Diasol is recalling 4,400 gallons of liquid concentrate for bicarbonate dialysis, product 100230-10-DEX100, because the safety and efficacy of the dialysis acid concentrate cannot be assured.

    Product
    Brand Name: Diasol Product Name: 100230-10-DEX100, Liquid Concentrate for Bicarbonate Dialysis Non Pyrogenic, 2K, 3.0CA, 1.0MG, 208.2 liters
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0986-2026·2025-12-31

    Campylobacter LYFO DISK controls recalled over failure to recover the organism

    Microbiologics is recalling LYFO DISK units for Campylobacter jejuni because affected units may fail to recover the target microorganism.

    Product
    LYFO DISK, Campylobacter jejuni subsp. jejuni derived from ATCC 29428, Catalog Number 0325L
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0994-2026·2025-12-31

    Transjugular access sets recalled over products manufactured out of specification

    Cook Incorporated is recalling 15 Ring Transjugular Intrahepatic Access Sets because affected lots may have been cut to the incorrect length, not correctly trimmed, and not properly inspected.

    Product
    Ring Transjugular Intrahepatic Access Sets, Reference Part Numbers: 1) RTPS-100; 2) RTPS-100-10.0; The Ring Transjugular Intrahepatic Access Set is intended for transjugular liver access in diagnostic and interventional procedures.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Food)·H-0348-2026·2025-12-31

    Sinus Cap herbal capsules recalled over unapproved drug claims and misbranding

    A New Life Herbs is recalling 38 bags of Sinus Cap Herbal Supplement over unapproved drug claims on the labeling and misbranding for having no Supplement Facts label.

    Product
    Sinus Cap Herbal Supplement, Herbs containing antibiotic, drying, expectorant, and emollient properties, Fenugreek, Thyme, Oregon Grape Root, & Bentonite Clay, 50 capsules/510 mg; packaged in a plastic bag
    Category
    Food
    Distribution
    12 states
  • ModerateFDA (Devices)·Z-0963-2026·2025-12-31

    Cranial tracker devices recalled over an error message preventing use

    Howmedica Osteonics is recalling 320 Stryker CranialMask Trackers because activating the device during surgery produces an error message that makes the device unusable.

    Product
    The Stryker CranialMask Tracker is a single-use device consisting of a flexible printed circuit board (PCB) with 31 infrared (IR) light-emitting diodes (LEDs) as well as an electronics control unit for the LEDs which includes its own battery power supply. The measured LED…
    Category
    Medical Device
    Distribution
    Distributed nationwide