The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

17801–17825 of 40287

  • ModerateFDA (Devices)·Z-1615-2020·2020-04-08

    Biomet Shoulder Baseplate Recall Due to Incorrect Packaging Contents

    Biomet is recalling 21 units of Comprehensive Reverse Shoulder Glenosphere Mini Baseplates because some packages contained two baseplates and no taper adapters.

    Product
    Biomet Comprehensive Reverse Shoulder Glenosphere Mini Baseplate With Taper Adapter-indicated for primary, fracture, or revision total shoulder replacement for the relief of pain and significant disability due to gross rotator cuff deficiency Item Number: 010000589
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1601-2020·2020-04-08

    Butterfly iQ Ultrasound System Recalled for Lack of FDA Approval

    Butterfly Network, Inc. is recalling 11,183 Butterfly iQ Ultrasound Systems because they were distributed without an approved 510(k).

    Product
    Butterfly iQ Ultrasound System containing the Auto EF(Ejection Fraction) Tool REF/Model: 850-20003 UDI: (01)00866646000206 Software versions 1.10.0, 1.11.0, 1.12.0, 1.13.0, 1.13.0, 1.14.0, 1.15.0 Product Usage: Intended use: Diagnostic ultrasound imaging and measurement of…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1635-2020·2020-04-08

    Trilliant Surgical Recalls 8mm Hammer Toe Reaming Kits Due to Incorrect Contents

    Trilliant Surgical is recalling 117 units of 8mm HTR Sterile Hammer Toe Reaming Kits because they may contain two identical reamers instead of one concave and one convex reamer.

    Product
    8mm HTR Sterile Hammer Toe Reaming Kit, Material: Stainless Steel, Sterile: R, PX only, UDI: (01)00812926022345(17)231225 (10)TSL007202
    Category
    Medical Device
    Distribution
    21 states
  • ModerateFDA (Devices)·Z-1611-2020·2020-04-08

    Trilliant Surgical 3S Hemi Toe Implant Instructions for Use Recall

    Trilliant Surgical is recalling Instructions for Use and Cleaning Protocols for the 3S Hemi Toe Implant System to update dry time parameters.

    Product
    Instructions for Use and Surgical Cleaning and Sterilization Protocol for Trilliant Surgical Ltd 3S Hemi Toe Implant System, Model 111-00-001. The firm name on the label is Trilliant Surgical Ltd, Houston, TX.
    Category
    Medical Device
    Distribution
    29 states
  • ModerateFDA (Devices)·Z-1606-2020·2020-04-08

    Trilliant Surgical Recalls Instructions for Use for Tiger Screw Systems

    Trilliant Surgical is recalling Instructions for Use and Cleaning Protocols for Tiger Screw Systems to update dry time parameters.

    Product
    Instructions for Use and Surgical Cleaning and Sterilization Protocol for: (1) Trilliant Surgical Ltd Tiger Headless Cannulated Screw System, Model 212-00-001; and (2) Combination Tiger Cannulated/Tiger Headless Cannulated Screw System, Model 210-00-101. The firm name…
    Category
    Medical Device
    Distribution
    29 states
  • ModerateFDA (Devices)·Z-1628-2020·2020-04-08

    Conformis Recalls iTotal PS Knee Replacement System Due to Labeling Error

    Conformis is recalling two iTotal PS Knee Replacement System kits because tibial trays were labeled with incorrect serial numbers and delivered to the wrong customers.

    Product
    iTotal PS Knee Replacement System, Model No. TPS-111-1111-010101, (ITOTAL PS IPOLY IMPLANT KIT LEFT) Product Usage: The iTotal CR Knee Replacement System is intended for use as a total knee replacement in patients with knee joint pain and disability whose conditions cannot be…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1609-2020·2020-04-08

    Trilliant Surgical Gridlock Plating System Instructions for Use Recall

    Trilliant Surgical is recalling Instructions for Use and Cleaning Protocols for the Gridlock Plating System to update dry time parameters.

    Product
    Instructions for Use and Surgical Cleaning and Sterilization Protocol for Trilliant Surgical Ltd Gridlock Plating System, Model 310-01-100. The firm name on the label is Trilliant Surgical Ltd, Houston, TX.
    Category
    Medical Device
    Distribution
    29 states
  • ModerateFDA (Devices)·Z-1624-2020·2020-04-08

    Gentell Hydrogel Ag Gauze Recalled for FDA Registration Deficiency

    Gentell, Inc. is recalling 20,025 units of Gentell Hydrogel Ag 4x4 gauze because the product was not properly registered with the FDA.

    Product
    Gentell Hydrogel Ag 4x4, model no. GEN-11420 - Product Usage: Under the care of a healthcare professional, Gentell Hydrogel Ag Saturated Gauze is indicated for partial and full thickness wounds, including pressure ulcers, venous stasis ulcers, diabetic ulcers, first and second…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1600-2020·2020-04-08

    Butterfly iQ Ultrasound System Auto Bladder Volume Tool Recalled for Regulatory Violation

    Butterfly Network, Inc. is recalling the Butterfly iQ Ultrasound System Auto Bladder Volume Tool because it was distributed without an approved 510(k).

    Product
    Butterfly iQ Ultrasound System Auto Bladder Volume Tool-The Auto Bladder Volume Tool is a segmentation measurement tool REF/Model: 850-20003 Software versions 1.13.0, 1.14.0, and 1.15.0 - Product Usage: Butterfly iQ is indicated for use by qualified and trained healthcare…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1612-2020·2020-04-08

    Trilliant Surgical Recalls Instructions for Use for Cannulated Screw Systems

    Trilliant Surgical, LLC is recalling Instructions for Use and Surgical Cleaning and Sterilization Protocols for two cannulated screw systems to update dry time parameters.

    Product
    Instructions for Use and Surgical Cleaning and Sterilization Protocol for: (1) Trilliant Surgical Ltd Tiger Large Cannulated Screw System, Model 215-00-001; and (2) Trilliant Surgical Ltd Large Cannulated Headless Screw System, Model 215-00-001. The firm name on the…
    Category
    Medical Device
    Distribution
    29 states
  • LowFDA (Devices)·Z-1625-2020·2020-04-08

    Gentell Hydrogel Ag Saturated Gauze Recalled for FDA Registration Deficiency

    Gentell, Inc. is recalling 6,433 units of Gentell Hydrogel Ag Saturated Gauze because the product was not properly registered with the FDA.

    Product
    Gentell Hydrogel Ag 4x8, model no. GEN-11820 - Product Usage: Under the care of a healthcare professional, Gentell Hydrogel Ag Saturated Gauze is indicated for partial and full thickness wounds, including pressure ulcers, venous stasis ulcers, diabetic ulcers, first and second…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1626-2020·2020-04-08

    Gentell Hydrogel Ag Wound Dressing Recalled for Registration Issues

    Gentell, Inc. is recalling Gentell Hydrogel Ag wound dressings because the product was not properly registered with the FDA.

    Product
    Gentell Hydrogel Ag 4oz. Tube, model no. - Product Usage: Under the care of a healthcare professional, Gentell Hydrogel Ag Silver Antimicrobial Wound Dressing is indicated for partial and full thickness wounds, including pressure ulcers, venous stasis ulcers, diabetic ulcers…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1589-2020·2020-04-01

    Medtronic MiniMed Paradigm Insulin Pumps Recalled for Cybersecurity Vulnerabilities

    Medtronic MiniMed is recalling 38 Paradigm insulin pumps due to cybersecurity vulnerabilities that could allow unauthorized wireless control of insulin delivery.

    Product
    Medtronic MiniMed Paradigm Insulin pump, model number MMT-522K
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1528-2020·2020-04-01

    Ev3 Pipeline Flex Embolization Device Recalled for Delivery System Fracture Risk

    Micro Therapeutics is recalling 762 Ev3 Pipeline Flex Embolization Devices because the delivery system may fracture during implantation, potentially leaving parts in the patient.

    Product
    ev3 Pipeline Flex Embolization Device with Shield Technology. Sold OUS. For neurological endovascular use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1527-2020·2020-04-01

    ev3 Pipeline Flex Embolization Device Recalled for Potential Fracture

    Micro Therapeutics Inc is recalling 1,050 ev3 Pipeline Flex Embolization Devices because the delivery system may fracture during implantation, potentially leaving a part in the patient.

    Product
    ev3 Pipeline Flex Embolization Device. For neurological endovascular use.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1591-2020·2020-04-01

    Medtronic MiniMed Paradigm Insulin Pump Recalled for Cybersecurity Vulnerabilities

    Medtronic MiniMed is recalling 23,221 Paradigm insulin pumps due to cybersecurity vulnerabilities that could allow unauthorized wireless control of insulin delivery.

    Product
    Medtronic MiniMed Paradigm Insulin pump, model number MMT-523
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1587-2020·2020-04-01

    Medtronic MiniMed Paradigm Insulin Pumps Recalled for Cybersecurity Vulnerabilities

    Medtronic MiniMed is recalling 88,243 Paradigm insulin pumps due to cybersecurity vulnerabilities that could allow unauthorized wireless control of insulin delivery.

    Product
    Medtronic MiniMed Paradigm Insulin pump, model number MMT-522
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1554-2020·2020-04-01

    Hill-Rom Recalls NaviCare Patient Safety Software Due to Bed Exit Mechanism Failure

    Hill-Rom Inc. is recalling NaviCare Patient Safety Software versions 3.5.400-3.9.300 because a software issue may cause the patient bed exit mechanism to fail to monitor or control.

    Product
    NaviCare Patient Safety Software Versions 3.5.400-3.9.300. The NaviCare Patient Safety (Patient Safety) Software is compatible with the following beds: 1. VersaCare Revision A-J with upgrade kit Revision K with UCB 1.18 2. Centrella (all versions) 3. Progressa…
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-1531-2020·2020-04-01

    Karl Storz Flexible Neuroscopes Recalled Due to Sterilization Manual Error

    Karl Storz is recalling 42 flexible neuroscopes because the instruction manual contains incorrect sterilization information for the STERIS System 1E, which may compromise sterility.

    Product
    Karl Storz, Model # 11161C2, Flexible Neuroscope
    Category
    Medical Device
    Distribution
    28 states
  • HighFDA (Devices)·Z-1588-2020·2020-04-01

    Medtronic MiniMed Paradigm Insulin Pump Recalled for Cybersecurity Vulnerabilities

    Medtronic MiniMed is recalling 225,498 Paradigm insulin pumps due to cybersecurity vulnerabilities that could allow unauthorized wireless control of insulin delivery.

    Product
    Medtronic MiniMed Paradigm Insulin pump, model number MMT-722
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1580-2020·2020-04-01

    Abbott Alinity ci-series Software Recalled for Performance Issues

    Abbott is recalling Alinity ci-series software version 2.6.2 and earlier due to identified potential performance issues.

    Product
    LN 3R70-01; software version 2.6.2 and earlier. The software is used with the Alinity i (LN 03R65-01) processing module and the Alinity c (LN 03R67-01) processing module.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1543-2020·2020-04-01

    Biomet Recalls Misidentified 9mm Shoulder Mini Humeral Stem Implants

    Biomet is recalling 14 units of 9mm Shoulder Mini Humeral Stems that were misidentified as 15mm units. The error poses a risk of improper surgical implantation.

    Product
    Comprehensive Shoulder System Mini Humeral Stem 9mm,, Model No. 113629 - Product Usage: The intended use of the comprehensive humeral stem mini is to act as the humeral component of the comprehensive total shoulder system.
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1560-2020·2020-04-01

    Dexcom G4 Platinum Recall Due to Hydroxyurea Interference

    Dexcom Inc is recalling G4 PLATINUM systems because hydroxyurea use may cause falsely elevated glucose readings.

    Product
    Dexcom G4 PLATINUM Continuous Glucose Monitoring System The Dexcom G4 PLATINUM Continuous Glucose Monitoring System is a glucose monitoring device indicated for detecting trends and tracking patterns in persons (age 18 and older) with diabetes.
    Category
    Medical Device
    Distribution
    0 states