The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6226–6250 of 27393

  • HighFDA (Devices)·Z-0891-2024·2024-02-07

    Knee Replacement Implant Component Recalled for Material Degradation Risk

    Howmedica Osteonics Corp. is recalling SCORPIO Total Knee Concentric Dome Patella components due to potential oxidation in raw materials over 5 years old. No illnesses have been reported.

    Product
    SCORPIO TOTAL KNEE CONCENTRIC DOME PATELLA-SZ #7 -Intended for knee replacement Part Number: 73-2710
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0953-2024·2024-02-07

    MRI Scanner Quadrature Coil Seal Failure Poses Patient Contact Risk

    Philips is recalling the Intera 1.5T Achieva Nova-Dual MRI scanner due to potential failure of the Quadrature Body Coil seal adhesive. If the seal fails, sharp edges may contact patients, risking skin injuries.

    Product
    Intera 1.5T Achieva Nova-Dual. Model (REF) Number 781173.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0865-2024·2024-02-07

    GE Voluson IC9-RS Ultrasound Probes Recalled for Double Image Artifacts

    GE HealthCare is recalling certain IC9-RS intracavitary ultrasound probes due to a double image artifact that creates ghost images. This unrecognized artifact can lead to diagnostic errors.

    Product
    GE Voluson IC9-RS intracavitary probes, Model Number J48691PJ, Diagnostic ultrasound imaging and fluid flow analysis
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0886-2024·2024-02-07

    Knee Replacement Component Recalled Due to Raw Material Oxidation Risk

    Howmedica Osteonics Corp. is recalling a SCORPIO TOTAL KNEE prosthesis component because UHMWPE raw material over 5 years old may have elevated oxidation levels affecting material properties and implant performance. Consumers with this implant should contact their physician for guidance.

    Product
    SCORPIO TOTAL KNEE MEDIALIZED DOME PATELLA-SZ #11 -Intended for knee replacement Part Number: 73-0110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0970-2024·2024-02-07

    Vortex Surgical ACTU8 Forceps Recalled Due to Residue on Forceps Tips

    Vortex Surgical has voluntarily recalled 800 ACTU8 FORCEPS units due to residue identified on forceps tips. The recall affects surgical instruments distributed in the US (OH, WA, MN, MI, IA) and Korea.

    Product
    Vortex Surgical ACTU8 FORCEPS, 25 GA, ADAPTIVE, REF VS0740.25
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0885-2024·2024-02-07

    Knee Replacement Insert Recalled Due to Potential Material Oxidation

    Howmedica Osteonics is recalling Scorpio-Flex knee prosthesis inserts due to potential oxidation in UHMWPE raw material over 5 years old, which could impact material properties.

    Product
    Scorpio-Flex Ttl Kn P-S Tib Brg Insrt Asy- -Intended for knee replacement Part Number: 72-16-0910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0826-2024·2024-02-07

    Custom Procedural Convenience Kits Recalled for Sterilization Validation Failure

    American Contract Systems is recalling 244 custom procedural kits (Baby PICC, Pediatric PICC, and PORT PACK) distributed nationwide. Components subjected to sterilization without proper validation documentation may have reduced functionality or elevated sterilization residuals.

    Product
    Custom procedural convenience kits and trays, general hospital use, labeled as: a) Baby PICC Kit, kit number UIBP90J; b) Baby PICC Kit, kit number UIBP90K; c) PORT PACK (PS 058330), kit number UIPO82AB; d) Pediatric PICC Kit, kit number UIPP76K;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0832-2024·2024-02-07

    Ophthalmic procedural kits recalled due to inadequate sterilization validation

    American Contract Systems is recalling 940 ophthalmic surgical kits nationwide due to undocumented components that may lack functionality, drug efficacy, or contain elevated sterilization residuals.

    Product
    Custom procedural convenience kits and trays, Ophthalmic use, labeled as: a) EYE PACK, kit number LVEY27; b) Laminectomy, kit number UIOL34AG
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0822-2024·2024-02-07

    Custom Surgical Procedure Kits Recalled for Improper Sterilization Assessment

    American Contract Systems is recalling 3,196 custom surgical procedure kits because sterilized components lacked documented suitability assessment. The components may have lost functionality or accumulated excessive sterilization residuals.

    Product
    Custom procedural convenience kits and trays, gastroenterological & urological, labeled as: a) LAP KIDNEY MODULE, kit number AGKD50L; b) ROBOTIC PROSTATE PACK - 264852, kit number ANPR34S; c) LAP CHOLE - 213388, kit number BFLC02AD; d) GENERAL LAPAROSCOPY PACK, kit numbe
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0828-2024·2024-02-07

    Obstetrical and Gynecological Surgical Kits Recalled for Sterilization Assessment Defects

    American Contract Systems is recalling 1,020 obstetrical and gynecological surgical kits because components were sterilized without documented assessment of their suitability to the process, potentially causing loss of functionality or drug efficacy.

    Product
    Custom procedural convenience kits and trays, Obstetrical & Gynecological use, labeled as: a) LOWER PELVIC PACK, kit number AGLP52L; b) OB/GYN DAVINCI PACK A RG BASIN, kit number HGOB98G; c) DAVINCI GYN PACK, kit number HHDV17; d) KIT, GYNE ROBOTIC, kit number MMGR44D;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0972-2024·2024-02-07

    NovoTHOR Whole Body Light Pod Gen 3.0 Canopy Strut Ball Stud May Fail

    A ball stud on the gas strut may fail on NovoTHOR Whole Body Light Pod units, potentially causing injury if the canopy malfunctions while someone is using the device.

    Product
    NovoTHOR Whole Body Light Pod, Gen 3.0 (1) Product Code S2188 - Reg (2) Product Code S2189 - Reg PRX (3) Product Code S2190 - XL
    Category
    Medical Device
    Distribution
    17 states
  • HighFDA (Devices)·Z-0963-2024·2024-02-07

    Medline Adult Blood Culture Kits Recalled Due to Unlabeled Component Expiration Dates

    Medline is recalling specific Adult Blood Culture Kits because the expiration date of an internal Bactec component is not reflected on the kit insert, creating a risk of using an expired component.

    Product
    MEDLINE ADULT BLOOD CULTURE KIT, Reorder Number DYNDH1694A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0900-2024·2024-02-07

    Scorpio NRG Tibial Bearing Insert Assembly Recall Due to Material Oxidation Risk

    Howmedica Osteonics Corp. is recalling Scorpio NRG Tibial Bearing Insert Assemblies manufactured with raw material over 5 years old, which may develop elevated oxidation affecting implant durability.

    Product
    Scorpio NRG Tibial Brg Insert Assy -Intended for knee replacement Part Number: 82-2-0910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0928-2024·2024-02-07

    Tank hose assembly recalled for incorrect material and missing perforations

    AtriCure recalls tank hose assemblies due to manufacturing defects. Certain lots have outer sheaths missing required pin perforations and inner tubes made of incorrect material.

    Product
    Packaged, Tank Hose Assembly CMA-US, Product Catalog Number A001056
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0889-2024·2024-02-07

    Total Knee Replacement Component Recalled Due to Oxidation Risk

    Howmedica Osteonics Corp. is recalling SCORPIO Total Knee replacement components from specific manufacturing batches due to potential oxidation in raw materials over 5 years old. Oxidation can impact the material's properties.

    Product
    SCORPIO TOTAL KNEE MEDIALIZED DOME PATELLA-SZ #9 -Intended for knee replacement Part Number: 73-0910
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0867-2024·2024-02-07

    Aesculap Needle Holders Distributed With Incorrect Product Labels and Packaging

    Aesculap Inc. is recalling needle holder models that were distributed with incorrect product labels. The MB215R was labeled as MB362R and vice versa, which may cause procedural delays.

    Product
    MB215R - MILLS DUROGRIP TC Micro Needle Holder, straight, 8:, (203 mm), "TC MILLS NDLE HOLDRRND HNDLSTR203MM"
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0890-2024·2024-02-07

    Knee replacement implant recalled due to material oxidation risk

    Howmedica Osteonics is recalling a knee replacement patellar component that may have been manufactured with oxidized raw material. Products using UHMWPE over 5 years old can develop elevated oxidation and degraded material properties.

    Product
    SCORPIO TOTAL KNEE CONCENTRIC DOME PATELLA-SZ #11 -Intended for knee replacement Part Number: 73-2110
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0821-2024·2024-02-07

    Gastroenterological and Urological Procedure Kits Recalled for Sterilization Process Failures

    American Contract Systems is recalling AHN BIOPSY STERILE procedure kits nationwide because several components were improperly sterilized, potentially compromising device functionality and drug efficacy.

    Product
    Custom procedural convenience kits and trays, gastroenterological & urological, labeled as: AHN BIOPSY STERILE, kit number AHBP12A
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0887-2024·2024-02-07

    Knee Replacement Implant Recalled Due to Potential Material Degradation

    Knee replacement components recalled due to potential oxidation in UHMWPE material that could affect durability. Approximately 76 units distributed in the US with additional international distribution.

    Product
    SCORPIO TOTAL KNEE MEDIALIZED DOME PATELLA-SZ #5 -Intended for knee replacement Part Number: 73-0510
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0924-2024·2024-02-07

    Knee Replacement Insert May Degrade from Oxidized Raw Material

    Howmedica Osteonics is recalling PS LIPPED TIBIAL INSERT ASSY DURACON knee replacement inserts manufactured with UHMWPE raw material over 5 years old. The aged material may develop elevated oxidation that could impact material properties.

    Product
    PS LIPPED TIBIAL INSERT ASSY DURACON Intended for knee replacement Product Number: 6742-1-413
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0830-2024·2024-02-07

    Surgical kits for childbirth recalled for sterilization and functionality risks

    American Contract Systems is recalling C-section surgical kits that were sterilized without proper assessment. Components may have lost function or drug efficacy, or have excess sterilization residuals.

    Product
    Custom procedural convenience kits and trays, Obstetrical & Gynecological use, labeled as: a) C-SECTION PACK, kit number FDCS01AA; b) C-SECTION PACK, kit number FDCS01AB; c) C-SECTION STERILE PACK, kit number HGCS68J; d) C-SECTION PACK, kit number HICS50H; e) C-SECTION
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0880-2024·2024-02-07

    Knee Replacement Implant Recalled for Potential Material Degradation Risk

    Howmedica Osteonics Corp. is recalling SCORPIO TS TIB knee replacement implants manufactured with aged raw material that may develop oxidation, potentially affecting performance.

    Product
    SCORPIO TS TIB INSERT. Intended for knee replacement Part Number: 72-4-7518
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0936-2024·2024-02-07

    EZDilate Endoscopic Balloon Devices Recalled for Malfunction and Foreign Body Risk

    Olympus is recalling EZDilate Fixed Wire Balloon devices used for esophageal stricture treatment due to reports of inflation/deflation failures, bursting, leaking, and foreign body retention in patients.

    Product
    EZDilate Fixed Wire Balloon 13.5-14.5-15.5. Indicated for endoscopic dilation of strictures of the esophagus in adults and adolescents (>12 years). Model: BD-400P-1580
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0875-2024·2024-02-07

    Knee replacement implant recalled for potential material oxidation

    Howmedica Osteonics recalls SCORPIO TS TIB knee replacement inserts (lot TA21X9) manufactured from UHMWPE material over 5 years old due to potential elevated oxidation that could affect material properties. No injuries reported.

    Product
    SCORPIO TS TIB INSERT -Intended for knee replacement Part Number: 72-4-0321
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0843-2024·2024-02-07

    FX SHOULDER Centered Glenosphere with Screw may contain eccentric component

    FX SHOULDER is recalling 4 units of a shoulder glenosphere implant component due to potential manufacturing defects that may result in eccentric product orientation rather than the intended centered design.

    Product
    Centered Glenosphere w/Screw, CoCr/TA6V/TiN 10-degrees Tilt 32 mm, REF: 115-3210
    Category
    Medical Device
    Distribution
    Distributed nationwide