The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3451–3475 of 7524

  • SevereNHTSA·18V559000·2018-08-23

    REV Recalls 2018-2019 Motorhomes Due to Generator Exhaust Fire Risk

    REV Recreation Group is recalling 2018-2019 Fleetwood Pulse and Holiday Rambler Prodigy motorhomes because the generator exhaust pipe may contact the waste tank, increasing fire risk.

    Product
    HOLIDAY RAMBLER — HOLIDAY RAMBLER, FLEETWOOD PRODIGY, PULSE
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V561000·2018-08-23

    Thomas Built Buses Saf-T-Liner C2 School Bus Seat Recall

    Daimler Trucks North America is recalling 2017-2019 Thomas Built Buses Saf-T-Liner C2 school buses because seat mounting feet may pull through the floor joint in a crash.

    Product
    THOMAS BUILT BUSES — THOMAS BUILT BUSES SAF-T-LINER C2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V554000·2018-08-22

    Volvo Recalls 2019 XC40 Vehicles Due to Brake Pedal Rivet Defect

    Volvo is recalling 2019 XC40 vehicles because brake pedals may not be correctly riveted, potentially reducing braking performance and increasing crash risk.

    Product
    VOLVO — VOLVO XC40
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V551000·2018-08-21

    Nissan and Chevrolet Recall for Ignition Switch Stalling Risk

    Nissan is recalling 2017-2018 models including the Versa, Sentra, and NV200 because the ignition switch may shift, causing the engine to stall and increasing crash risk.

    Product
    NISSAN — NISSAN, CHEVROLET NV, VERSA NOTE, NV200 TAXI, VERSA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V548000·2018-08-20

    Ford Recalls 2018-2019 Vehicles for Electrical Arc Fire Risk

    Ford is recalling 2018-2019 Edge, Flex, MKX, and MKT vehicles because improperly secured power supply cables may cause an electrical arc, increasing the risk of a fire.

    Product
    FORD — FORD, LINCOLN EDGE, MKX, MKT, FLEX
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V546000·2018-08-17

    Winnebago Recalls 2016-2019 Motorhomes Due to Unfused Solar Charging Circuit

    Winnebago is recalling 2016-2019 motorhomes because an unfused auxiliary solar charging circuit can increase the risk of fire if solar panels exceed the circuit's amperage capacity.

    Product
    WINNEBAGO — WINNEBAGO TREND, PASEO, JOURNEY, ERA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V545000·2018-08-17

    2019 Coachmen Freedom Express Recalled for Brake Wiring Defect

    Forest River is recalling 2019 Coachmen Freedom Express trailers because the break-away safety switch may not engage brakes if the trailer detaches.

    Product
    COACHMEN — COACHMEN FREEDOM EXPRESS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V542000·2018-08-16

    Volvo Recalls 2019 VNL and VNR Trucks for Fifth Wheel Defect

    Volvo is recalling 2019 VNL and VNR trucks because a narrow fifth wheel bracket may allow the trailer to separate from the tractor, increasing crash risk.

    Product
    VOLVO — VOLVO VNL, VNR
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V539000·2018-08-16

    Mercedes-Benz Recalls 2018 GLE and GLS Models for Brake Defect

    Mercedes-Benz is recalling 9,044 2018 GLE and GLS vehicles because rear brake caliper pistons may release gas, reducing braking performance.

    Product
    MERCEDES-BENZ — MERCEDES-BENZ GLS 450, AMG GLE63S, GLS 550, GLE 350
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V543000·2018-08-16

    Mack Recalls 2019 Anthem Trucks Due to Fifth Wheel Bracket Defect

    Mack Trucks is recalling 2019 Anthem trucks with Jost fifth wheel couplings because a narrow slider bracket may allow the trailer to separate, increasing crash risk.

    Product
    MACK — MACK ANTHEM (AN)
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V536000·2018-08-15

    Volkswagen Recalls Passat and Atlas for Brake Caliper Bolt Issue

    Volkswagen is recalling 2017-2018 Passat and 2018 Atlas vehicles because brake caliper bracket bolts may be loose, potentially reducing braking ability.

    Product
    VOLKSWAGEN — VOLKSWAGEN PASSAT, ATLAS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V538000·2018-08-15

    Spartan K2 Chassis Recalled for Park Brake Defect

    Spartan Motors is recalling 2018-2019 K2 vehicles because the park brake may fail to hold the vehicle on a grade, increasing crash risk.

    Product
    SPARTAN — SPARTAN K2
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V530000·2018-08-15

    KZRV Connect Recalled for Propane Line Fire Risk

    KZRV is recalling 2018-2019 Connect trailers because liquid propane lines routed through the wheel well may be damaged by road debris, increasing fire risk.

    Product
    KZRV — KZRV CONNECT
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V532000·2018-08-15

    Winnebago and Itasca Motorhomes Recalled for Propane Hose Leak Risk

    Winnebago is recalling 2012-2013 Era, View, Via, Itasca Navion, and Reyo motorhomes because high-pressure propane hoses may harden and leak, increasing fire risk.

    Product
    WINNEBAGO — WINNEBAGO, ITASCA VIEW, REYO, VIA, ERA
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V528000·2018-08-13

    Roadtrek Motorhomes Recalled for Potential Diesel Fuel Tank Damage

    Erwin Hymer is recalling 2017-2018 Roadtrek motorhomes because the diesel fuel tank may have been damaged during seat installation, increasing fire risk.

    Product
    ROADTREK — ROADTREK E-TREK, RS ADVENTUROUS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V529000·2018-08-13

    Roadtrek Zion Motorhomes Recalled for Rear Brake Line Damage Risk

    Erwin Hymer is recalling 2015-2018 Roadtrek Zion motorhomes because sofa installation may have damaged the rear brake line, increasing stopping distance and crash risk.

    Product
    ROADTREK — ROADTREK ZION
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V526000·2018-08-10

    KZRV Sportsmen Travel Trailers Recalled for Propane Line Fire Risk

    KZRV is recalling 2018-2019 Sportsmen 333BHK travel trailers because liquid propane lines routed through the wheel well may be damaged by road debris, increasing fire risk.

    Product
    KZRV — KZRV SPORTSMEN
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18E081000·2018-08-10

    Cummins Recalls Diesel Engines Due to Fuel Line Burst Risk

    Cummins is recalling ISX15 and X15 diesel engines because a restricted fuel pump screen can cause the nylon fuel line to burst, leading to fuel leaks or engine stalling.

    Product
    FUEL SYSTEM, OTHER:DELIVERY:FUEL PUMP recall
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V523000·2018-08-09

    Chrysler Recalls 2018-2019 Vehicles for Rear Brake Caliper Coating Defect

    Chrysler is recalling specific 2018-2019 Dodge and Jeep vehicles because rear brake caliper pistons may have insufficient coating, potentially reducing braking performance.

    Product
    DODGE — DODGE, JEEP GRAND CARAVAN, CHEROKEE, JOURNEY, COMPASS
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18V525000·2018-08-09

    Freightliner Trucks Recalled for Insufficiently Tightened Brake Caliper Bolts

    Daimler Trucks North America is recalling 2018-2019 Freightliner trucks because brake caliper mounting bolts may be loose, which can reduce braking effectiveness and increase crash risk.

    Product
    FREIGHTLINER — FREIGHTLINER 108SD, 114SD, CASCADIA, 122SD
    Category
    Vehicle
    Distribution
    Distributed nationwide
  • SevereNHTSA·18E080000·2018-08-09

    TRW Recalls Outer Tie Rods for Loss of Steering Risk

    TRW is recalling specific outer tie rods sold as replacement parts for 1988-2000 GM vehicles because the locking nut may fail, causing a loss of steering.

    Product
    STEERING:LINKAGES:TIE ROD ASSEMBLY recall
    Category
    Vehicle
    Distribution
    Distributed nationwide