Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

19401–19425 of 29481

  • HighFDA (Food)·F-1365-2016·2016-05-25

    Michel et Augustin Butter Cookies Recalled for Undeclared Hazelnuts

    Michel et Augustin is recalling Petites baguettes butter cookies due to undeclared hazelnuts caused by miss-packaging.

    Product
    Michel et Augustin brand Petites baguettes butter cookies Dark Chocolate with a pinch of salt, NET WT. 1.58 oz (45g), UPC 81266802016, Product of the Netherlands -- Manufactured for Michel et Augustin SA, 151 rue de Billancourt (Grand Paris) France --- The label states "May…
    Category
    Food
    Distribution
    3 states
  • HighFDA (Food)·F-1375-2016·2016-05-25

    QTrade Organic Ginger Root Tea Recalled for Salmonella Risk

    QTrade Teas & Herbs is recalling Organic Ginger Root Tea Bag Cut due to potential Salmonella contamination. The product was distributed in California, Illinois, New Jersey, and Canada.

    Product
    Organic Ginger Peach Iced Tea, 100x1oz box, item #60001
    Category
    Food
    Distribution
    3 states
  • HighFDA (Food)·F-1373-2016·2016-05-25

    QTrade Organic Green Tea Hojicha Recalled for Potential Salmonella Contamination

    QTrade Teas & Herbs is recalling Organic Green Tea Hojicha due to the potential for Salmonella contamination. The product was distributed in the US and internationally.

    Product
    Organic Green Tea Hojicha, Net 16 kgs, (bulk product 16 kg boxes with inner liner)
    Category
    Food
    Distribution
    3 states
  • HighFDA (Food)·F-1341-2016·2016-05-25

    Bunge Canola Frying Oil Recalled for Foreign Material Presence

    Bunge Oil North America Inc. is recalling Taco Bell Liquid Canola Frying Oil due to the presence of a foreign material inside the jugs.

    Product
    Taco Bell Liquid Canola Frying Oil, 35 lb., (15.88 kg), Packaged Exclusively for use by Taco Bell and its franchisees. Taco Bell Corp, Irvine, CA 92618
    Category
    Food
    Distribution
    9 states
  • HighFDA (Food)·F-1363-2016·2016-05-25

    UNFI Recalls Commercial Wheat Germ Due to E. coli Contamination

    UNFI is recalling 32 bags of Commercial Wheat Germ 274000 because the product contains generic E. coli. The recall covers distribution in 17 states.

    Product
    COMMERCIAL WHEAT GERM 274000, 50.00 lbs. (22.68 kg); UPC Code: 0-26938-46535-3
    Category
    Food
    Distribution
    16 states
  • HighFDA (Food)·F-1371-2016·2016-05-25

    Nice! Peach Slices Recalled for Potential Glass Contamination

    MW Polar Foods is recalling Nice! Peach Slices and Mixed Fruit in 8-ounce jars due to potential glass in the product.

    Product
    Sliced Peaches (In Light Syrup), Net Wt. 8oz (227g), Bottle Label UPC 0-49022-80894-2, Case UPC 100-49022-80894-9
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1374-2016·2016-05-25

    QTrade Recalls Organic Ginger Root Tea Due to Salmonella Risk

    QTrade Teas & Herbs is recalling Organic Ginger Root Tea Bag Cut because it has the potential to be contaminated with Salmonella.

    Product
    Organic Ginger Root Tea Bag Cut (TBC), 25 kgs
    Category
    Food
    Distribution
    3 states
  • HighFDA (Food)·F-1358-2016·2016-05-25

    Bunge Creamy Frying Shortening Recalled for Foreign Material

    Bunge Oil North America Inc. is recalling 1,400 cases of Bunge Creamy Frying Shortening due to the presence of a foreign material inside the jugs.

    Product
    Bunge Creamy Frying Shortening, Partially Hydrogenated Soybean Oil "For All Deep Frying", Net Wt 35 lb (17.4 Liter), Distributed By. IAS International American Supermarkets, 226 Old New Brunswick Road, Piscataway, NJ 08854, Mfd By: Bunge, Bradley, IL 60915, UPC 0 00 78684 69024…
    Category
    Food
    Distribution
    9 states
  • HighFDA (Food)·F-1366-2016·2016-05-25

    Empirical Labs Recalls Liposomal Magnesium Supplement for Mold Contamination Risk

    Empirical Labs is recalling Liposomal Magnesium Nutritional Supplement due to potential mold contamination. The recall affects 1,972 bottles sold nationwide.

    Product
    Liposomal Magnesium Nutritional Supplement. 6 FL. OZ (180 ml) The product is packaged in a six ounce, plastic, Royalty Bottle, with a 24mm vented flip top lid. item number: DES004Z. Sold under brands DESBIO and Seeking Health
    Category
    Food
    Distribution
    Distributed nationwide
  • HighFDA (Food)·F-1354-2016·2016-05-25

    Bunge Canola Oil Recalled for Foreign Material Presence

    Bunge Oil North America Inc. is recalling specific lots of Daily Chef Food Service Pure Canola Oil due to the presence of foreign material inside the jugs.

    Product
    Daily Chef Food Service Pure Canola Oil (Aceite de Canola Para Ensaladas), Net/Neto 4.5 Gal (17L) and Net Wt/Peso Neto, 35 lbs. (15.8 kg), Distributed By: Sam's Inc., Bentonville, AR 72716, UPC 0 78742 06149 8
    Category
    Food
    Distribution
    9 states
  • HighFDA (Food)·F-1372-201·2016-05-25

    Nice! Mixed Fruit Recalled for Potential Glass Contamination

    Milky Way Intl Trading Corp is recalling Nice! Mixed Fruit in 8-ounce jars due to potential glass in the product.

    Product
    Mixed Fruit (In Light Syrup), Net Wt. 8oz (227g), Bottle Label UPC 0-49022-80896-6, Case UPC 100-49022-80896-3
    Category
    Food
    Distribution
    Distributed nationwide
  • ModerateFDA (Food)·F-1349-2016·2016-05-25

    Bunge Canola Frying Oil Blend Recalled for Foreign Material

    Bunge Oil North America Inc. is recalling 1,923 cases of Yum Canola Frying Oil Blend due to the presence of foreign material inside the jugs.

    Product
    Yum Canola Frying Oil Blend, Net Wt., 35 lbs. (15.88 kg), Packaged Exclusively for use by Yum! Brands Global Restaurants, Yum Brands, Louisville, KY 40232
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1345-2016·2016-05-25

    Bunge Canola Oil Recalled for Foreign Material in Jugs

    Bunge Oil North America Inc. is recalling Old World Clear Canola Liquid Frying Oil due to the presence of a foreign material inside the jugs.

    Product
    Old World Clear Canola Liquid Frying Oil (Aceite de Canola Para Freir Liquido y Transparente), Net Wt.35 lbs. (15.88 kg), MFD in USA By: Bunge Oils, St. Louis, MO 63146-1000, UPC 0 00 78684 70021 9
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1357-2016·2016-05-25

    Bunge Corn Oil Recalled for Foreign Material in Jugs

    Bunge Oil North America Inc. is recalling 180 cases of Bunge Corn Oil due to the presence of foreign material inside the jugs.

    Product
    Bunge Corn Oil (Aceite de maiz), Net Wt 35 lb (15.88 kg), MFD in USA By: Bunge Oils, St. Louis, MO 63146-1000, UPC 0 00 78684 69118 0
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1344-2016·2016-05-25

    Bunge Recalls Old World Canola Oil Due to Foreign Material

    Bunge Oil North America Inc. is recalling 35-pound jugs of Old World Canola Oil because of the presence of a foreign material inside the containers.

    Product
    Old World Canola Oil (Aceite de Canola), Net Wt. 35 lbs. (15.88 kg), MFD in USA By: Bunge Oils, St. Louis, MO 63146-1000, UPC 0 00 78684 70020 2
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1347-2016·2016-05-25

    Bunge Creamy Soy Liquid Frying Oil Recalled for Foreign Material

    Bunge Oil North America Inc. is recalling 2,040 cases of Bunge Creamy Soy Liquid Frying Oil due to the presence of foreign material inside the jugs.

    Product
    Bunge Creamy Soy Liquid Frying Oil (Aceite de Soja Para Freir Liquido y Cremosa), Net Wt. 35 lbs. (15.88 kg), MFD in USA By: Bunge Oils, St. Louis, MO 63146-1000, UPC 0 00 78684 73353 8
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1339-2016·2016-05-25

    Bunge Vegetable Oil Recalled Due to Foreign Material Presence

    Bunge Oil North America Inc. is recalling Harvest Value Clear Vegetable Frying Oil because of foreign material found inside the jugs.

    Product
    Harvest Value Clear Vegetable Frying Oil, 35 lb., (15.88 kg), Distributed By: U.S. Foodservice, Inc,, Rosemont, IL 60018, UPC 5 07 58108 00302 1
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1346-2016·2016-05-25

    Bunge Soybean Oil Recalled Due to Foreign Material in Jugs

    Bunge Oil North America Inc. is recalling specific lots of Old World Soybean Oil because of the presence of a foreign material inside the jugs.

    Product
    Old World Soybean Oil (Aceite de Soja), Net Wt.35 lbs. (15.88 kg), MFD in USA By: Bunge Oils, St. Louis, MO 63146-1000, UPC 0 00 78684 70011 0
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1350-2016·2016-05-25

    Bunge Vegetable Oil Recalled Due to Foreign Material Presence

    Bunge Oil North America Inc. is recalling specific lots of vegetable oil because foreign material was found inside the jugs.

    Product
    Nathan's Pure Corn Oil, Net Weight 35 lb (15.88 kg), Packed Exclusively for: Nathan's, General Offices: One Jericho Plaza, Jericho, NY 11753, UPC 0 07 16071 99955 5
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1355-2016·2016-05-25

    Bunge Vegetable Oil Recalled for Foreign Material in Jugs

    Bunge Oil North America Inc. is recalling Hooters Creamy Liquid soybean Frying Oil due to the presence of a foreign material inside the jugs.

    Product
    Hooters Creamy Liquid soybean Frying Oil, Net Wt 35 lb (15.88 kg), MFD in USA By: Bunge Oils, St. Louis, MO 63146-1000, UPC 0 00 78684 73746 8
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1335-2016·2016-05-25

    Prayon Recalls Food Grade Phosphoric Acid Due to Cumene Contamination

    Prayon Inc. is recalling specific batches of food grade phosphoric acid due to potential contamination with trace levels of cumene.

    Product
    Phosphoric Acid, 75% and 85% Food Grade (Brand Name PRAYPHOS PPA 75% FG and PRAYPHOS PPA 85% FG)
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1351-2016·2016-05-25

    Bunge Vegetable Oil Recalled for Foreign Material in Jugs

    Bunge Oil North America Inc. is recalling EB Golden Fry Clear Liquid Shortening due to the presence of foreign material inside the jugs.

    Product
    EB Golden Fry Clear Liquid Shortening, 35 lbs. (15.88 kg), Distributed By: EB Express Provisions, Inc., 181-191 Vanderpool Street, Newark, NJ 07114, UPC 0 00 78684 73630 0
    Category
    Food
    Distribution
    9 states
  • ModerateFDA (Food)·F-1364-2016·2016-05-25

    Buell's Orchard Recalls Trader Joe's Apple Cider Due to Patulin

    Buell's Orchard is recalling Trader Joe's Apple Cider because patulin was detected at 63.7 ppb. The product was distributed in Massachusetts and Pennsylvania.

    Product
    TRADER JOE'S Apple Cider, NOT FROM CONCENTRATE SHAKE WELL NO PRESERVATIVES 100% JUICE PASTEURIZED. PERISHABLE, KEEP REFRIGERATED. NET 64 FL OZ (2 QT) 1.89 L. UPC: 0016 4580.
    Category
    Food
    Distribution
    2 states
  • ModerateFDA (Food)·F-1337-2016·2016-05-25

    Bunge Canola Deep Frying Oil Recalled for Foreign Material

    Bunge Oil North America Inc. is recalling specific lots of Nutra-Clear NT Ultra Canola Deep Frying Oil due to the presence of foreign material inside the jugs.

    Product
    Nutra-Clear NT Ultra - Bunge Canola Deep Frying Oil (High Stability), 35 lb., (15.88 kg), MFD in USA by: Bunge Oils, St. Louis, MO 63146-1000, UPC 0 00 78684 72477 2
    Category
    Food
    Distribution
    9 states