The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

25076–25100 of 29501

  • SevereFDA (Food)·F-1395-2014·2014-01-22

    Jensen's Recalls Hot Smoked Sockeye Salmon for Botulism Risk

    Jensen's Old Fashioned Smokehouse is recalling 3,446 lbs of hot smoked sockeye salmon in Washington due to missing 'KEEP FROZEN' labels and potential Clostridium botulinum contamination.

    Product
    Hot Smoked Alaskan Sockeye Salmon is a low salt, vacuum packaged. Great Ruby Fish Co Sockeye Hot smoked salmon has no labels. ROLF'S Choice Sockeye Salmon is labeled in parts: "***ROLF'S CHOICE***SMOKED ALASKAN SOCKEYE SALMON*** Ingredients: salmon, salt, brown sugar…
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-2012-2014·2014-01-22

    Big Blue Fisheries Recalls Pepper Smoked Coho Salmon Due to Botulism Risk

    Big Blue Fisheries is recalling all smoked products, including Pepper Smoked Coho Salmon, because they may not have been properly cooked and could be contaminated with Clostridium botulinum.

    Product
    Pepper Smoked Coho Salmon is sold in vacuum packed plastic packages, net weight from 0.5 to 1 lb., with label located on the front that include the pack date and AK 604. The label is read in parts: "***BIG BLUE FISHERIES, LLC***Pepper Smoked Coho Salmon***Ingredients: Wild…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1415-2014·2014-01-22

    Big Blue Fisheries Recalls Smoked Black Cod Due to Botulism Risk

    Big Blue Fisheries is recalling all smoked products, including hickory smoked black cod, because they may not have been properly cooked and could be contaminated with Clostridium botulinum.

    Product
    Hickory Smoked Black Cod is sold in vacuum packed plastic packages, net weight from 0.5 to 1 lb., with label located on the front that include the pack date and AK 604. The label is read in parts: "***BIG BLUE FISHERIES, LLC***Hickory Smoked Black Cod***Ingredients: Wild…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1422-2014·2014-01-22

    Glass Onion Catering Recalls Southwestern Salad Kits Due to E. coli Outbreak

    Atherstone Foods Inc dba Glass Onion Catering is recalling Southwestern Salad kits because an investigation linked the supplier to an E. coli O157:H7 outbreak.

    Product
    Southwestern Salad kit (20 lb box). Contents in individual Bags: Cooked Soo Foo Roasted Corn Red and Yellow Bell Peppers Jalapenos Cilantro Pepitas Dressing. Packaged for Whole Foods Manufactured by Glass Onion Catering, Richmond, CA
    Category
    Food
    Distribution
    2 states
  • SevereFDA (Food)·F-1392-2014·2014-01-22

    Jensen's Recalls Teriyaki Salmon for Missing Frozen Label and Botulism Risk

    Jensen's Old Fashioned Smokehouse is recalling Alaska King Seafoods Short Strips Teriyaki salmon because it lacks a 'KEEP FROZEN' label, creating a potential risk of Clostridium botulinum contamination.

    Product
    Short Strips Teriyaki is a low salt, vacuum packaged, Hot Smoked Salmon, and it is sold under Alaska King Seafoods brand. The labels contain the following statement above or below the product name and/or ingredient statement: "***IMPORTANT KEEP FROZEN***THAW UNDER…
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1406-2014·2014-01-22

    Big Blue Fisheries Recalls Pepper Smoked King Salmon Due to Botulism Risk

    Big Blue Fisheries is recalling all smoked products because they may not have been properly cooked, posing a risk of Clostridium botulinum contamination.

    Product
    Pepper Smoked King Salmon. Product sold in vacuum packed plastic packages, net weight from 0.5 to 1 lb., with label located on the front that include the pack date and AK 604. The label is read in parts: "***BIG BLUE FISHERIES, LLC***Pepper Smoked King Salmon***Ingredients…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1391-2014·2014-01-22

    Jensen's Recalls Hot Smoked Salmon for Botulism Risk and Labeling Errors

    Jensen's Old Fashioned Smokehouse is recalling 14,628 lbs of hot smoked salmon in Washington due to potential Clostridium botulinum contamination and missing 'KEEP FROZEN' labels.

    Product
    Low salt, vacuum packaged, Hot Smoked Salmon (may include any of the following varieties Coho, Keta, King, Sockeye). Jensen's product is labeled in part "*** JENSEN'S SEATTLE STYLE SMOKED WILD PACIFIC SALMON JENESN'S SMOKEHOUSE, INC. *** Keep Refrigerated Below 38 F***…
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1401-2014·2014-01-22

    Josephson's Hot Smoked Salmon Recalled for Undercooking and Botulism Risk

    Josephson's Smokehouse is recalling hot smoked garlic pepper Atlantic salmon because the products were undercooked, posing a potential hazard of Clostridium botulinum toxin formation.

    Product
    Hot Smoked Garlic Pepper Atlantic Salmon, Item HS-D, vacuum packaged and either frozen or refrigerated, ranging in size between about one pound to eight pounds. The UPC for the net weight 0.445 lbs. is 0 240100 214246. The label is read in part: HOT SMOKED GARLIC PEPPER…
    Category
    Food
    Distribution
    23 states
  • SevereFDA (Food)·F-1400-2014·2014-01-22

    Josephson's Hot Smoked Salmon Recalled for Undercooking and Botulism Risk

    Josephson's Smokehouse is recalling Hot Smoked Wine Maple Salmon because the products were undercooked, posing a potential hazard of Clostridium botulinum toxin formation.

    Product
    Hot Smoked Wine Maple Salmon, Item HS-B, vacuum packaged and either frozen or refrigerated, ranging in size between about one pound to eight pounds. The UPC for net weight 0.445 lbs. is 0 240080 618023. The label is read in part: HOT SMOKED WINE-MAPLE SALMON SALMON…
    Category
    Food
    Distribution
    23 states
  • SevereFDA (Food)·F-1403-2014·2014-01-22

    Bee International Recalls Sweet Spots Candy for Undeclared Egg Allergen

    Bee International is recalling Sweet Spots Candy because it contains an undeclared egg allergen. The affected products were distributed nationwide in the US and Canada.

    Product
    Candy Sweet Spots, 2oz. (3 display packages/case; 12-2oz packages/display case). UPC 0-73563-00471-6
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1388-2014·2014-01-22

    Jensen's Recalls Hot Smoked Black Cod Due to Botulism Risk

    Jensen's Old Fashioned Smokehouse is recalling Hot Smoked Black Cod sold in Washington because it may lack 'KEEP FROZEN' labels and could be contaminated with Clostridium botulinum.

    Product
    Low salt, vacuum packaged, Hot Smoked Black Cod sold under Clippership. No label was provided.
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1408-2014·2014-01-22

    Big Blue Fisheries Recalls Smoked King Salmon Due to Botulism Risk

    Big Blue Fisheries is recalling all smoked products because they may not have been properly cooked, posing a risk of Clostridium botulinum contamination.

    Product
    Teriyaki Smoked King Salmon is sold in vacuum packed plastic packages, net weight from 0.5 to 1 lb., with label located on the front that include the pack date and AK 604. The label is read in parts: "***BIG BLUE FISHERIES, LLC***Teriyaki Smoked King Salmon***Ingredients…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1398-2014·2014-01-22

    Jensen's Recalls Hot Smoked Salmon Due to Botulism Risk

    Jensen's Old Fashioned Smokehouse is recalling Jack's Fish Spot Hot Smoked Atlantic Garlic & Pepper Chunks because the product may lack 'KEEP FROZEN' labeling and could be contaminated with Clostridium botulinum.

    Product
    Jack's Fish Spot Hot Smoked Atlantic Garlic & Pepper Chunks is a low salt, vacuum packaged, hot smoked salmon. The product is labeled in parts: "***Hot Smoked Atlantic Salmon*** INGREDIENTS: Atlantic Salmon, Salt, Brown Sugar, Spices and Natural Wood Smoke***Important: Keep…
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1417-2014·2014-01-22

    Fosforel Herring Fillets Recalled Due to Listeria monocytogenes Presence

    Zip International Group LLC is recalling Fosforel Atlantika Herring Fillets in Oil after Listeria monocytogenes was detected in samples.

    Product
    Fosforel Atlantika Herring Fillet in Oil (200 g) Product of Russia Imported by: Zip International Group LLC 160 Raritan Center Parkway, Unit 6 Edison, NJ 08837 UPC: 4607106577526
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1399-2014·2014-01-22

    Jensen's Recalls Hot Smoked Salmon Due to Botulism Risk

    Jensen's Old Fashioned Smokehouse is recalling Jack's Fish Spot Hot Smoked Cajun Atlantic Salmon because it may lack 'KEEP FROZEN' labeling, posing a risk of Clostridium botulinum contamination.

    Product
    Jack's Fish Spot Hot Smoked Cajun Atlantic is a low salt, vacuum packaged, Hot Smoked Salmon. This product is labeled in parts: "***Hot Smoked Atlantic Salmon*** INGREDIENTS: Atlantic Salmon, Salt, Brown Sugar, Spices and Natural Wood Smoke***Important: Keep Frozen. Thaw…
    Category
    Food
    Distribution
    1 state
  • SevereFDA (Food)·F-1404-2014·2014-01-22

    Concertos In Chocolate Recalls Solid Milk Chocolate Santa Candy

    Concertos In Chocolate LLC is recalling Solid Milk Chocolate Santa candy because it is incorrectly labeled and contains an undeclared milk allergen.

    Product
    SOLID MILK CHOCOLATE SANTA candy
    Category
    Food
    Distribution
    5 states
  • SevereFDA (Food)·F-2011-2014·2014-01-22

    Big Blue Fisheries Recalls Smoked Coho Salmon Due to Botulism Risk

    Big Blue Fisheries is recalling all smoked products because they may not have been properly cooked, posing a risk of Clostridium botulinum contamination.

    Product
    Hickory Smoked Coho Salmon is sold in vacuum packed plastic packages, net weight from 0.5 to 1 lb., with label located on the front that include the pack date and AK 604. The label is read in parts: "***BIG BLUE FISHERIES, LLC***Hickory Smoked Coho Salmon***Ingredients: Wild…
    Category
    Food
    Distribution
    Distributed nationwide
  • SevereFDA (Food)·F-1390-2014·2014-01-22

    Jensen's Recalls Hot Smoked Sturgeon Due to Botulism Risk

    Jensen's Old Fashioned Smokehouse is recalling hot smoked sturgeon because inconsistent 'KEEP FROZEN' labeling creates a risk of Clostridium botulinum contamination.

    Product
    Low salt, vacuum packaged, Hot Smoked Sturgeon Clippership product is labeled in parts: "***Keep Frozen. Thaw under refrigeration immediately before use***".
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-1394-2014·2014-01-22

    Jensen's Recalls Hot Smoked Pink Salmon for Botulism Risk

    Jensen's Old Fashioned Smokehouse is recalling 20,271 lbs of Hot Smoked Pink Salmon in Washington due to missing 'KEEP FROZEN' labels and potential Clostridium botulinum contamination.

    Product
    Hot Smoked Pink Salmon is Low salt, vacuum packaged. Clippership Hot Smoked Pink Salmon does not have any labels. Lummi Island Co-Op product's label is read in parts: "***WILD SMOKED PINK SALMON***LUMMI ISLANDWILD.COM***KEEP FROZEN***Thawing Instructions: Remove all…
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-1386-2014·2014-01-22

    Colony Brands Recalls Lobster Bisque Due to Undeclared Wheat Allergen

    Colony Brands is recalling 19 units of Lobster Bisque because the product contains undeclared wheat. The recall affects specific lots distributed across 12 states.

    Product
    Lobster Bisque, product 45036. Net WT 4.0 lbs. Keep Frozen.
    Category
    Food
    Distribution
    13 states
  • HighFDA (Food)·F-1387-2014·2014-01-22

    Jensen's Recalls Hot Smoked Salmon Due to Labeling and Botulism Risk

    Jensen's Old Fashioned Smokehouse is recalling hot smoked salmon because inconsistent 'KEEP FROZEN' labeling creates a potential risk of Clostridium botulinum contamination.

    Product
    Low salt, vacuum packaged, Hot Smoked Farmed Raised Salmon (Atlantic, Coho, Keta, King, Steelhead, and Sockeye). AKS (Alaska King Seafoods) products such as Sockeye Traditional, Coho Traditional, Keta Traditional, Farmed Atlantic Traditional are labeled in parts…
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-1424-2014·2014-01-22

    Whole Foods Recalls Artichoke Wheatberry Salad for E. coli Risk

    Whole Foods Market is recalling Artichoke Wheatberry Salad in Northern California because ingredients are under recall for potential E. coli O157:H7.

    Product
    Artichoke Wheatberry Salad: sold in prepackaged pint and half pint containers in the Prepared Foods Dept. as well as sold fresh from the Deli case and salad bar.
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-1425-2014·2014-01-22

    Whole Foods Southwest Salad Recalled for Potential E. coli Contamination

    Whole Foods Market is recalling Southwest SooFoo Salad in Northern California due to potential E. coli O157:H7 contamination in ingredients.

    Product
    Southwest SooFoo Salad: sold in prepackaged pint and half pint containers in the Prepared Foods Dept. as well as sold fresh from the Deli case and salad bar.
    Category
    Food
    Distribution
    1 state
  • HighFDA (Food)·F-1418-2014·2014-01-22

    Glass Onion Catering Recalls Greek Style Orzo Salad Due to E. coli

    Atherstone Foods Inc dba Glass Onion Catering is recalling Delish Greek Style Orzo Salad because an investigation linked the supplier to an E. coli O157:H7 outbreak.

    Product
    Delish Greek Style Orzo Salad; Traditional orzo, cucumber, red bell peppers, green onion and Kalamata olives tossed with a creamy Greek Style yogurt and feta dressing. 6 oz (170g) in clam shell plastic container. Packaged for Walgreens Manufactured by Glass Onion…
    Category
    Food
    Distribution
    2 states
  • ModerateFDA (Food)·F-1393-2014·2014-01-22

    Jensen's Recalls Low Salt Vacuum Packaged Smoked Salmon Products

    Jensen's Old Fashioned Smokehouse is recalling low salt, vacuum packaged smoked salmon products not labeled 'KEEP FROZEN'.

    Product
    Low salt, vacuum packaged, Hot Smoked King Nova Salmon. The following is information on the individual products for Alaska King Seafoods brand: All AKS stands for Alaska King Seafoods product labels contain the following statement above or below the product name and/or…
    Category
    Food
    Distribution
    1 state