The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

24276–24300 of 40299

  • HighFDA (Devices)·Z-1331-2018·2018-04-18

    Arrow International Recalls Certain Central Venous Catheterization Kits

    Arrow International is recalling specific lots of central venous and vessel catheterization kits because the seals may be incomplete, potentially compromising sterility.

    Product
    (1) Central Venous Catheterization Kit, Part Number (PN): ASK-04300-PHP; (2) Single-Lumen Central Venous Catheterization Kit with Blue FlexTip(R) Catheter, PN: ASK-04301-WBH; (3) Vessel Catheterization Kit, PN: ASK-04550-NYP
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1327-2018·2018-04-18

    Arrow PICC Kit Recall Due to Potential Sterility Seal Failure

    Arrow International is recalling specific lots of ARROW PICC Kits because the seals may not be completely closed, meaning the product's sterility cannot be guaranteed.

    Product
    Pressure Injectable ARROW(R) PICC Kit with Chlorag+ard Technology, Part Numbers: (1) ASK-45541-RWJ4; (2) ASK-45552-RWJ4
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1336-2018·2018-04-18

    Arrow Hemodialysis Catheter Kits Recalled for Sterility Concerns

    Arrow International is recalling specific lots of hemodialysis catheterization kits because they may not be completely sealed, potentially compromising sterility.

    Product
    ARROWg+ard Blue¿ Two-Lumen Hemodialysis Catheterization Kit for High Volume Infusions (1) Part Number (PN): CDC-22122-1A; (2) PN: CDC-25122-1A; (3) PN: CDC-25142-1A; (4) CDC-26142-1A
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1363-2018·2018-04-18

    Orthofix Recalls Connector System Set Screws Due to Size Discrepancies

    Orthofix is voluntarily recalling specific lots of Connector System set screws because size discrepancies may prevent proper driver fit or cause stripping.

    Product
    ORTHOFIX, Connector System, SMALL SET SCREW, REF 79-2003
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1371-2018·2018-04-18

    Hamilton-C2 Ventilator Units Recalled Due to Battery Fuel Gauge Inaccuracy

    Hamilton Medical AG is recalling 739 Hamilton-C2 Ventilator Units worldwide because the battery fuel gauge may inaccurately indicate a higher charge than available.

    Product
    Hamilton-C2 Ventilator Unit Intended to provide ventilator support to adults and pediatrics and optionally infants and neonates in the hospital.
    Category
    Medical Device
    Distribution
    29 states
  • HighFDA (Devices)·Z-1360-2018·2018-04-18

    Zimmer GmbH Recalls Normed Charcot Osteotome Chisels for Disinfection Gap

    Zimmer GmbH is recalling Normed Charcot Osteotome Chisels because a gap between the handle and metal chisel may prevent proper disinfection or sterilization between uses.

    Product
    Normed Charcot Osteotome Chisel (Various sizes)
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-1366-2018·2018-04-18

    Beckman Coulter iQ200 Urine Analyzer Recall for Barcode Reading Failures

    Beckman Coulter is recalling iQ200 Series Urine Microscopy Analyzers because they may fail to read dilution barcodes, causing erroneous results that could delay treatment.

    Product
    iQ200 Series Urine Microscopy Analyzer with Barcode Reader Model NFT-2100, Catalog #s: 800-3046, 800-3047, 800-3052, 800-3053, 800-3802, 800-3803, 800-3900, 800-3920, 800-3925, 800-3931, 800-3933, 800-3934, 800-3935, 800-3937, 800-3950, 800-3951, 800-3042, 800-3043, 800-3044…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1362-2018·2018-04-18

    Beckman Coulter iQ200 Urine Analyzer Recall for Under-Reporting Issue

    Beckman Coulter is recalling the iQ200 Series Urine Microscopy Analyzer because it may under-report casts when certain measurement settings are used. The issue could affect test results during initial setup or after settings are changed.

    Product
    BECKMAN COULTER iQ200 Series Urine Microscopy Analyzer, Catalog Numbers: 700-3345, C10684, 700-3375, C10683, 700-3325, 700-3347, 700-3320, 700-3322, 700-3370
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1354-2018·2018-04-18

    Bard Premature Infant Feeding Tube Recalled for Ineffective Fusion

    C.R. Bard is recalling 42,200 units of Bard Premature Infant Feeding Tubes due to potentially ineffective fusion between the tubing and the ENFit connector.

    Product
    Bard(R) Premature Infant Feeding Tube, ENFit(TM), REF EN0036400 Product Usage: BARD(R) Nasogastric Sump Tubes with ENFit(TM) connector are intended to be used for: Decompression of stomach by suction or aspiration of gastric contents Short-term administration of term…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1347-2018·2018-04-18

    ICU Medical Recalls Infusion Sets with Incorrect Spin Collars

    ICU Medical is recalling 7,600 sterile intravascular administration sets because they were manufactured with an incorrect spin collar. The sets were distributed in the US, Canada, and Japan.

    Product
    14 cm (5.5") Appx 0.27 ml, Smallbore Ext Set w/SURPLUG¿ Nano T-Connector, Clamp, Rotating Luer, 50 pouches per case, Item IR-NG31481B, Sterile, Rx. The firm name on the label is icumedical, San Clemente, CA. The Intravascular Administration Set is a single use, sterile…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1343-2018·2018-04-18

    ICU Medical Recalls Infusion Sets with Incorrect Spin Collars

    ICU Medical is recalling specific lots of sterile intravascular administration sets because they were manufactured with an incorrect spin collar.

    Product
    6.5" (17 cm) Appx. 0.57 ml, Trifuse Ext Set w/3 MicroClave¿ Clear, NanoClave¿ T-Connector, 4 Clamps, Rotating Luer, Item A1254, 50 pouches per case, Sterile, Rx. The firm name on the label is icumedical, San Clemente, CA. The Intravascular Administration Set is a single…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1353-2018·2018-04-18

    Certified Safety Mfg Recalls First Aid Kits with Leaking Honeywell Eyewash

    Certified Safety Mfg Inc is recalling 748 first aid and emergency kits containing Honeywell eyewash due to leaking bottles. The affected units were distributed nationwide.

    Product
    First aid/emergency kits containing Honeywell eyewash: CSM kit number Kit/cabinet Description CSM Eyewash# Size: Honeywell Part# K206125 LXXV - 75V " Economy Cabinet 3 Shelf R508016 Eye Wash " 4 oz. 32-000452-0000 K 206154 LXXV - 75V " Deluxe Cabinet ¿3 Shelf RS08016 Eye…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1370-2018·2018-04-18

    Teleflex Baker Jejunostomy Tubes Recalled for Missing Latex Warning

    Teleflex Medical Europe Ltd is recalling 200 Baker Jejunostomy Tubes because the packaging lacks a required warning that the product contains natural rubber latex.

    Product
    Baker Jejunostomy Tubes: Product Code Equivalent Code (a) 655300160 655316 (b) 655500200 655520
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1339-2018·2018-04-18

    Ethicon Recalls PDS Plus Sutures Due to Incorrect Expiry Date Labeling

    Ethicon, Inc. is recalling PDS Plus Antibacterial Sutures because three lots were labeled with a five-year expiry date instead of the correct two-year date.

    Product
    PDS Plus Antibacterial (Polydioxanone) Suture Size 1 PDS PLUS Violet 27 Single Armed OS-4 Needle
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1342-2018·2018-04-18

    ICU Medical Recalls Smallbore Extension Sets with Incorrect Spin Collars

    ICU Medical is recalling 11,500 smallbore extension sets manufactured with incorrect spin collars. The affected units were distributed in the US, Canada, and Japan.

    Product
    6.5" (17 cm) Smallbore Ext Set w/Remv MicroClave¿ Clear, NanoClave¿ T-Connector, Clamp, Rotating Luer, Bulk Non-Sterile, 500 per case, Item A1009-NS, Rx. The firm name on the label is icumedical, San Clemente, CA. The Intravascular Administration Set is a single use…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1369-2018·2018-04-18

    Teleflex Recalls Simplastic Suprapubic Puncture Instruments for Missing Latex Warning

    Teleflex Medical Europe Ltd is recalling Simplastic Suprapubic Puncture Instruments because the packaging lacks a required warning that the products contain natural rubber latex.

    Product
    Simplastic Suprapubic Puncture Instruments: Product Code Equivalent Code (a) 650704100 551310 (b) 650704120 551312 (c) 650704160 551316 Product Usage: RUSCH Simplastic Suprapubic Puncture Instruments are indicated for emergency suprapubic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1317-2018·2018-04-18

    Smith & Nephew Recalls D-RAD Self-Tapping Locking Screws

    Smith & Nephew is recalling D-RAD Self-Tapping Locking Screws because they were machined out of specification. The screws measured over tolerance within the head thread form.

    Product
    D-RAD Self-Tapping Locking Screw intended for the fixation of fractures involving the distal radius. smith&nephew D-RAD 2.4MM X 10MM S-T LOCKING SCREW, REF 74692410, QTY (1), STERILE R
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-1345-2018·2018-04-18

    ICU Medical Recalls 7-inch Smallbore Infusion Sets with Incorrect Spin Collar

    ICU Medical is recalling 2,950 sterile 7-inch smallbore infusion sets because they were manufactured with an incorrect spin collar. The affected lots were distributed in the US, Canada, and Japan.

    Product
    7" Smallbore Ext Set w/MicroClave¿, Clave¿ T-Connector, Clamp, Rotating Luer, 50 pouches per case, Item B9900-629, Sterile, Rx. The firm name on the label is icumedical, San Clemente, CA. The Intravascular Administration Set is a single use, sterile, non-pyrogenic device…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1321-2018·2018-04-18

    Mindray Hematology Diluent Recall for Elevated Platelet Background Counts

    Mindray is recalling specific lots of M-53D and M-30D hematology diluents because they may cause the analyzer to produce an elevated platelet background count.

    Product
    Hematology Diluent M-53D used with BC-5390 Hematology Analyzer; Part Number: 105-007867-00 (20L container) The M-53D diluent is an azide-free, filtered isotonic solution for counting and sizing blood cells. It is for use with the Mindray BC-5390 Hematology Analyzer.
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-1340-2018·2018-04-18

    Ethicon Recalls PDS Plus Antibacterial Sutures Due to Incorrect Expiry Dates

    Ethicon is recalling PDS Plus Antibacterial Sutures because three lots were labeled with an incorrect five-year expiry date instead of the correct two-year date.

    Product
    PDS Plus Antibacterial (Polydioxanone) Suture Size 0 PDS Plus Violet 36 Single Armed CTB-1 Needle
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1338-2018·2018-04-18

    Ethicon Recalls PDS Plus Antibacterial Sutures Due to Incorrect Expiry Dates

    Ethicon, Inc. is recalling specific lots of PDS Plus Antibacterial Sutures because they were labeled with an incorrect expiry date of five years instead of two.

    Product
    PDS Plus Antibacterial (Polydioxanone) Suture Size 0 PDS Plus Violet 36 Single Armed CT-1 Needle
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1346-2018·2018-04-18

    ICU Medical Recalls Smallbore Extension Sets Due to Incorrect Spin Collar

    ICU Medical is recalling 100 pouches of 5-inch Smallbore Extension Sets because they were manufactured with an incorrect spin collar.

    Product
    5" (13 cm) Smallbore Ext Set w/MicroClave¿, Clave¿ T-Connector, Clamp, Rotating Luer, 50 pouches per case, Item B99066, Sterile, Rx. The firm name on the label is icumedical, San Clemente, CA. The Intravascular Administration Set is a single use, sterile, non-pyrogenic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1368-2018·2018-04-18

    Teleflex Medical Recalls Rectal Catheters Due to Missing Latex Warning

    Teleflex Medical Europe Ltd is recalling 6,340 rectal catheters because the packaging lacks a required warning that the product contains natural rubber latex.

    Product
    Rectal Catheters; Product Code Equivalent Code 580114 580114 Product Usage: Rectal Balloon Catheter is inserted into the rectum to measure the abdominal pressure as bladder filled.
    Category
    Medical Device
    Distribution
    Distributed nationwide