The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

20801–20825 of 40248

  • ModerateFDA (Devices)·Z-1440-2019·2019-05-29

    Zimmer GmbH Recalls Cannulated Orthopedic Drills Due to Material Concerns

    Zimmer GmbH is recalling specific cannulated orthopedic drills because an investigation found they may have been manufactured from a different material than specified.

    Product
    Drill, cannulated, 2x95mm, AO, Item Number 502015623
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1441-2019·2019-05-29

    Zimmer GmbH Recalls Cannulated Drills Due to Material Specification Concerns

    Zimmer GmbH is recalling specific cannulated drills because an investigation found they may have been manufactured from a different material than specified.

    Product
    Drill, cannulated, 2.8x120mm, AO, Item Number 502015628
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1475-2019·2019-05-29

    Zimmer GmbH Recalls Cannulated Drills Due to Material Concerns

    Zimmer GmbH is recalling specific cannulated drills because they may have been manufactured from a material different from the specifications.

    Product
    Drill, cannulated, 4x150mm, AO, Item Number ST502015403
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1377-2019·2019-05-29

    Remel Thio Med w/Dex, Hem, Vit K Media Recalled for Performance Failure

    Remel Inc is recalling 8,615 units of Thio Med w/Dex, Hem, Vit K media due to potential performance failures starting 57 days after manufacturing.

    Product
    Thio Med w/Dex, Hem, Vit K (5ml) 100/PK Product Usage; Recommended for use in qualitative procedures as a general purpose media for the cultivation of aerobes and anaerobes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1372-2019·2019-05-29

    Polymer Technology Systems Recalls Lipid Panel Test Strips for Fit Issues

    Polymer Technology Systems is recalling certain Lipid Panel test strips because they may not fit tightly into the optical block, potentially causing incorrect test results.

    Product
    Lipid Panel test strips (as a component of smart bundles), REF 2729, also private labeled under Henry Schein as REF 570-0412
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1379-2019·2019-05-29

    Remel Thio Med w/Dex, Hem, Vit K Media Recalled for Performance Failure

    Remel Inc is recalling Thio Med w/Dex, Hem, Vit K media because it may fail performance testing after 57 days. The expiration date is shortened to 56 days.

    Product
    Thio Med w/Dex, Hem, Vit K (7ml) 20/PK Product Usage; Recommended for use in qualitative procedures as a general purpose media for the cultivation of aerobes and anaerobes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1461-2019·2019-05-29

    Zimmer GmbH Recalls Cannulated Orthopedic Screws Due to Material Concerns

    Zimmer GmbH is recalling specific cannulated orthopedic screws because they may have been manufactured from a material different from the specifications.

    Product
    CBS high, countersink, cannulated, AO, Item Number 503004542
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1387-2019·2019-05-29

    KaVo Recalls DEXIS Titanium Intraoral Sensors Due to Calibration Error

    KaVo Dental Technologies is recalling 211 DEXIS Titanium Intraoral Sensors because incorrectly programmed calibration files may reduce image quality.

    Product
    DEXIS Titanium Intraoral Sensor Product Usage: The DEXIS Titanium Intraoral Sensor is a USB-driven sensor which is intended to acquire dental intraoral radiographic images. The DEXIS / KaVo sensor shall be operated by healthcare professionals, who are educated and competent…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1456-2019·2019-05-29

    Zimmer GmbH Recalls Cannulated Orthopedic Screws Due to Material Concerns

    Zimmer GmbH is recalling specific cannulated orthopedic screws because an investigation found they may have been manufactured from a different material than specified.

    Product
    CBS high, countersink, cannulated, round-shaft, Item Number 503004342
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1406-2019·2019-05-29

    Remel Thio Med w/Dex, Hem, Vit K Media Recalled for Performance Failure

    Remel Inc is recalling 1,069 units of Thio Med w/Dex, Hem, Vit K media due to potential performance failures after 106 days.

    Product
    Thio Med w/Dex, Hem, Vit K (10ml) 20/PK Product Usage: Recommended for use in qualitative procedures as a general purpose media for the cultivation of aerobes and anaerobes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1370-2019·2019-05-29

    Cook Stent Sets Recalled for Missing Warning About Stent Knotting

    Cook Inc. is recalling Kwart RetroInject and Salle Intraoperative Pyeloplasty Stent Sets because the instructions for use did not include a warning for stent knotting.

    Product
    Cook Salle Intraoperative Pyeloplasty Stent Set PRODUCT/CATALOG NUMBER/GPN: 4.0 Fr - SIPSF-040018-56-6 G18168 4.0 Fr - SIPSF-040018-59 G32773 4.7 Fr SIPSF-050018-59 G32774
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1396-2019·2019-05-29

    Boston Scientific Recalls Auriga 30 Laser Systems Due to Power Degradation

    Boston Scientific is recalling specific Auriga 30 laser systems because a mechanical cooling issue may cause faster-than-normal power degradation and low power errors.

    Product
    AURIGA 30 BRAZIL ZERO COST SYSTEM UPN: M0068S30BZ0 Product Usage: The Auriga XL 4007 Laser System and the Auriga 30 Laser System including a fiber optic delivery system is intended to be used in surgical procedures such as open, laparoscopic and endoscopic, to perform…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1447-2019·2019-05-29

    Zimmer V-TEK IVP Step Drill Recalled for Material Specification Deviation

    Zimmer GmbH is recalling V-TEK IVP step drills because they may have been manufactured from a material different from the applicable specifications.

    Product
    V-TEK", IVP step drill 2-3.4x124mm, 16mm stop, AO, Item Number 502015636
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1380-2019·2019-05-29

    Remel Thio Med w/Dex, Hem, Vit, K Media Recalled for Performance Failure

    Remel Inc is recalling Thio Med w/Dex, Hem, Vit, K media because it may fail performance testing after 57 days. The expiration date is shortened to 56 days.

    Product
    Thio Med w/Dex, Hem, Vit, K (7ml) 100/PK Product Usage; Recommended for use in qualitative procedures as a general purpose media for the cultivation of aerobes and anaerobes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1422-2019·2019-05-29

    Zimmer GmbH Recalls 2.5x87mm AO Drills Due to Material Concerns

    Zimmer GmbH is recalling specific AO drills because they may be made from the wrong material. The products were distributed to 38 US states.

    Product
    Drill, 2.5x87mm, AO, Item Number 502015137
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1485-2019·2019-05-29

    Zimmer GmbH Recalls 3.2x145mm AO Drills Due to Material Concerns

    Zimmer GmbH is recalling specific AO drills because they may have been manufactured from a different material than specified.

    Product
    Drill, 3.2x145mm, AO, Item Number ST502015650
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1414-2019·2019-05-29

    Zimmer GmbH Recalls Drill Sys2.7 Due to Material Specification Deviation

    Zimmer GmbH is recalling Drill Sys2.7 surgical instruments because they may have been manufactured from a material different from the defined specifications.

    Product
    Drill Sys2.7, 2x103mm, AO, Item Number 502015107
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1404-2019·2019-05-29

    Remel Thio Med Media Recalled for Potential Performance Failure

    Remel Inc is recalling Thio Med w/o Ind, w/Dex media because it may fail performance testing after 106 days. The expiration date is being shortened to 105 days.

    Product
    Thio Med w/o Ind, w/Dex (10ml) 20/PK Product Usage: Recommended for use in qualitative procedures as a general purpose media for the cultivation of aerobes and anaerobes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1280-2019·2019-05-29

    Neusoft NeuViz 128 CT Scanner Recalled for Software Defect

    Neusoft Medical Systems is recalling six NeuViz 128 CT scanners due to a software defect that may cause image loss during specific scans.

    Product
    NeuViz 128 Multi-slice CT Scanner System Product Usage: The Multi-Slice CT Scanner System can be used as a whole body computed tomography x-ray system featuring a continuously rotating x-ray tube and detector array. The acquired x-ray transmission data is reconstructed by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1279-2019·2019-05-29

    Neusoft NeuViz 64 CT Scanner Recalled for Image Loss Defect

    Neusoft Medical Systems is recalling 37 NeuViz 64 CT scanners due to a software defect that can cause image loss during specific scans.

    Product
    NeuViz 64 Multi-slice CT Scanner System Product Usage: The Multi-Slice CT Scanner System can be used as a whole body computed tomography x-ray system featuring a continuously rotating x-ray tube and detector array. The acquired x-ray transmission data is reconstructed by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1408-2019·2019-05-29

    Remel Thio Med Culture Media Recalled for Potential Performance Failure

    Remel Inc is recalling Thio Med culture media due to potential performance failures after 106 days. The expiration date is shortened to 105 days.

    Product
    Thio Med w/o Ind, w/Dex (18ml) 100/PK Product Usage: Recommended for use in qualitative procedures as a general purpose media for the cultivation of aerobes and anaerobes
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1469-2019·2019-05-29

    Zimmer GmbH Recalls 2.7mm Orthopedic Drills Due to Material Concerns

    Zimmer GmbH is recalling specific 2.7mm orthopedic drills because they may have been manufactured from a material different from the specifications.

    Product
    Drill for 2.7mm screw, 23mm stop, 2x103mm, AO, Item Number ST502015207
    Category
    Medical Device
    Distribution
    42 states
  • ModerateFDA (Devices)·Z-1460-2019·2019-05-29

    Zimmer GmbH Recalls CBS Micro Countersink Cannulated AO Screws

    Zimmer GmbH is recalling CBS micro, countersink, cannulated, AO screws (Item Number 503004541) because they may have been manufactured from a different material than specified.

    Product
    CBS micro, countersink, cannulated, AO, Item Number 503004541
    Category
    Medical Device
    Distribution
    42 states
  • LowFDA (Devices)·Z-1389-2019·2019-05-29

    Collagen Matrix Recalls Neomem Membrane Due to Incorrect Packaging

    Collagen Matrix, Inc. is recalling Neomem Resorbable Collagen Membranes because they were packaged in the wrong box, potentially inside a Neomem FLEXPLUS box.

    Product
    Neomem Resorbable Collagen Membrane, 15 mm x 20 mm Reference Number (model): N1520 - Product Usage: Neomem is a bioresorbable, implantable collagen material that is intended for use in dental surgery procedures as a material for placement in the area of dental implant, bone…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1275-2019·2019-05-22

    Ethicon Intraluminal Staplers Recalled for Insufficient Firing Stroke

    Ethicon Endo-Surgery is recalling 434,614 Straight Intraluminal Staplers (Model SDH21A) because they may have an insufficient firing stroke to break the washer and completely form staples.

    Product
    Straight Intraluminal Staplers, 21 mm diameter, Model SDH21A The Ethicon Endo-Surgery Intraluminal Staplers (ILS) are anastomotic staplers available in four sizes to permit proper matching of instrument to diameter of the lumen. The instrument permits tissue attachment to the…
    Category
    Medical Device
    Distribution
    Distributed nationwide