The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

19026–19050 of 27647

  • HighFDA (Devices)·Z-0125-2018·2017-11-29

    Halyard Health Recalls NOVAPLUS Endotracheal Suction Kits Due to Leaking Vials

    Halyard Health is recalling NOVAPLUS Endotracheal WET PAK Closed Suction Systems because 15ml saline vials may leak, potentially exposing contents to infectious agents.

    Product
    NOVAPLUS* Endotracheal WET PAK* Closed Suction System for Adults with BALLARD* Technology, Double Swivel Elbow, 14 F. 6 vials per kit, 20 kits per case.
    Category
    Medical Device
    Distribution
    38 states
  • HighFDA (Devices)·Z-0127-2018·2017-11-29

    Exactech Recalls Optetrak Offset Tibial Tray Due to Design Incompatibility

    Exactech is recalling 109 Optetrak Offset Tibial Tray and Screws units due to a design incompatibility with certain offset spine stiffener screws and constrained condylar tibial inserts.

    Product
    Optetrak Offset Tibial Tray and Screws, Size 1DeltaF/0T, Alpha, Ref 208-04-11, Sterile, RX.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-0122-2018·2017-11-29

    Halyard Closed Suction System Recalled Due to Saline Vial Leaking Risk

    Halyard Health is recalling specific lots of Closed Suction Systems because 15ml saline vials may leak, potentially exposing contents to infectious agents.

    Product
    Halyard Closed Suction System for Adults, 14 F, T-Piece, Wet Pak. 12 or 6 vials per kit, 20 kits per case.
    Category
    Medical Device
    Distribution
    38 states
  • HighFDA (Devices)·Z-0139-2018·2017-11-29

    Exactech Recalls Optetrak Offset Tibial Tray Due to Design Incompatibility

    Exactech is recalling 573 Optetrak Offset Tibial Trays and Screws due to a design incompatibility with certain offset spine stiffener screws and constrained condylar tibial inserts.

    Product
    Optetrak Offset Tibial Tray and Screws, Size 4F/3T, Beta, Ref 208-04-42, Sterile, RX.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-0124-2018·2017-11-29

    Halyard Closed Suction System Saline Vials Recalled for Leaking Risk

    Halyard Health is recalling specific lots of saline vials used in closed suction systems because they may leak, potentially exposing the contents to infectious agents.

    Product
    Halyard Closed Suction System for Adults, 14 F, T-Piece, MDI, Wet Pak. 12 vials per kit, 20 kits per case.
    Category
    Medical Device
    Distribution
    38 states
  • HighFDA (Devices)·Z-0123-2018·2017-11-29

    Halyard Turbo-Cleaning Closed Suction System Recalled for Potential Saline Vial Leaking

    Halyard Health is recalling Turbo-Cleaning Closed Suction Systems because 15ml saline vials may leak, potentially exposing contents to infectious agents.

    Product
    Halyard Turbo-Cleaning Closed Suction System for Adults, 14 F, DSE, MDI, Wet Pak. 12 vials per kit, 20 kits per case.
    Category
    Medical Device
    Distribution
    38 states
  • HighFDA (Devices)·Z-0112-2018·2017-11-29

    Medline Pediatric Suction Catheters Recalled for Sterilization Error

    Medline Industries is recalling 190 units of pediatric elbow closed suction catheters because they were distributed before being sterilized.

    Product
    MEDLINE PEDI ELBOW CLOSED SUCTION CATHETER, 8Fr, REF DYNCPE8
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-0134-2018·2017-11-29

    Exactech Recalls Optetrak Offset Tibial Trays Due to Design Incompatibility

    Exactech is recalling 893 Optetrak Offset Tibial Trays and Screws because of a design incompatibility with certain offset spine stiffener screws and constrained condylar tibial inserts.

    Product
    Optetrak Offset Tibial Tray and Screws, Size 1F/2T & 2F/2T, Beta, Ref 208-04-24, Sterile, RX.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-0119-2018·2017-11-29

    Halyard Closed Suction System Saline Vials Recalled for Potential Leaking

    Halyard Health is recalling specific lots of saline vials used in closed suction systems because they may leak, potentially exposing contents to infectious agents.

    Product
    Halyard Closed Suction System for Adults, 14 F, DSE, Wet Pak. 12 or 6 vials per kit, 20 kits per case.
    Category
    Medical Device
    Distribution
    38 states
  • HighFDA (Devices)·Z-0133-2018·2017-11-29

    Exactech Recalls Optetrak Offset Tibial Trays Due to Design Incompatibility

    Exactech is recalling 801 Optetrak Offset Tibial Trays and Screws due to a design incompatibility with certain offset spine stiffener screws and constrained condylar tibial inserts.

    Product
    Optetrak Offset Tibial Tray and Screws, Size 1F/2T & 2F/2T, Alpha, Ref 208-04-23, Sterile, RX.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-0120-2018·2017-11-29

    Halyard Closed Suction System Recalled for Potential Saline Vial Leaks

    Halyard Health is recalling specific lots of Closed Suction Systems because the saline vials may leak, potentially exposing contents to infectious agents.

    Product
    Halyard Closed Suction System for Adults, 14 F, Elbow, Directional Tip, Wet Pak. 12 vials per kit, 20 kits per case.
    Category
    Medical Device
    Distribution
    38 states
  • HighFDA (Devices)·Z-0128-2018·2017-11-29

    Exactech Recalls Optetrak Offset Tibial Trays Due to Design Incompatibility

    Exactech, Inc. is recalling 114 Optetrak Offset Tibial Trays and Screws due to a design incompatibility with certain offset spine stiffener screws and constrained condylar tibial inserts.

    Product
    Optetrak Offset Tibial Tray and Screws, Size 1DeltaF/0T, Beta, Ref 208-04-12, Sterile, RX.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-0163-2018·2017-11-29

    Medline Plastic Transfer Belts Recalled for Locking Mechanism Failure

    Medline Industries is recalling 1,428 plastic transfer belts because the locking mechanism may fail, allowing the strap to slip through the buckle.

    Product
    Transfer/Gait Belt, Plastic, Wipeable, packaged in plastic bag, 36 plastic bags per box.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0113-2018·2017-11-29

    Medline Suction Catheters Recalled for Sterilization Error

    Medline Industries is recalling 120 units of sterile suction catheters that were distributed before being sterilized.

    Product
    MEDLINE DOUBLE SWIVEL CLOSED SUCTION CATHETER, 21.3 in (54 cm) FOR ENDOTRACHEAL TUBE, 12 Fr, REF DYNCSDS12, 1 Each, Sterile
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-0090-2018·2017-11-22

    WalkMed Infusion Pump Reservoir Bags Recalled for Fluid Leaks

    WalkMed, LLC is recalling 25,920 infusion pump reservoir bags due to reported fluid leaks at the luer connection.

    Product
    Reservoir Bag for WalkMed Infusion Pump Part Number 204820 Catalog Number IPR-86/10 65 mL and Reservoir Bag for WalkMed Infusion Pump Part Number 204821 Catalog Number IPR-150/10 150 mL The WalkMed Reservoir Bag is designed for use with the WalkMed 350VL Ambulatory pump and is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0102-2018·2017-11-22

    Zimmer Biomet Recalls ROSA Surgical Device Due to Navigation Software Shift

    Zimmer Biomet is recalling 21 ROSA Surgical Devices because an undetected shift between the navigation software display and actual patient anatomy was identified.

    Product
    ROSA Surgical Device 2.5.8. It is intended to be used in the operating room for the spatial positioning and orientation of an instrument holder or tool guide
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0100-2018·2017-11-22

    Zimmer Biomet Recalls ROSA Surgical Device Due to Optical Sensor Failure

    Zimmer Biomet is recalling 14 ROSA Surgical Devices because a cable disconnection may cause the optical distance sensor to fail.

    Product
    ROSA Surgical Device 2.5.8 ROSA Surgical Device is a computer-controlled electromechanical arm. It is intended to be used in the operating room for the spatial positioning and orientation of an instrument holder or tool guide. Guidance is based on a pre-operative plan developed…
    Category
    Medical Device
    Distribution
    2 states
  • HighFDA (Devices)·Z-0096-2018·2017-11-22

    Zimmer Biomet ROSA Surgical Device Recalled for Potential Force Sensor Break

    Zimmer Biomet is recalling 21 ROSA Surgical Devices due to a possible break in the Force Sensor connector. The devices were distributed to facilities in Ohio, Michigan, and Texas.

    Product
    ROSA Surgical Device 2.5.8 ROSA Surgical Device is a computer-controlled electromechanical arm. It is intended to be used in the operating room for the spatial positioning and orientation of an instrument holder or tool guide. Guidance is based on a pre-operative plan developed…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0091-2018·2017-11-22

    Beckman Coulter AQUIOS CL Flow Cytometer Recalled for Sample Misidentification Risk

    Beckman Coulter is recalling 268 AQUIOS CL Flow Cytometers because the system may duplicate sample requests, leading to sample misidentification when connected to a Laboratory Information System.

    Product
    AQUIOS CL Flow Cytometer, Catalog No. B30166, Rx. The firm name on the label is Beckman Coulter Ireland Inc., Ireland. The AQUIOS CL Flow Cytometer is intended for use as an in vitro diagnostic device for immunophenotyping. It is used in conjunction with the following…
    Category
    Medical Device
    Distribution
    16 states
  • HighFDA (Devices)·Z-0099-2018·2017-11-22

    Zimmer Biomet Recalls ROSA Surgical Devices Due to Observed Instability

    Zimmer Biomet is recalling 53 ROSA Surgical Devices because of observed instability. The devices are computer-controlled arms used in neurosurgery.

    Product
    ROSA Surgical Device 2.5.8 ROSA Surgical Device is a computer-controlled electromechanical arm. It is intended to be used in the operating room for the spatial positioning and orientation of an instrument holder or tool guide. Guidance is based on a pre-operative plan…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0101-2018·2017-11-22

    ICU Medical Recalls Plum 360 Infusion Systems Due to Software Malfunction

    ICU Medical is recalling 21,461 Plum 360 Infusion Systems because a software defect can prevent users from stopping the pump or restarting delivery under specific conditions.

    Product
    Plum 360 Infusion System, List number 30010.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0092-2018·2017-11-22

    Smith & Nephew Legion Knee Wedge Recalled for Incorrect Screw Size

    Smith & Nephew is recalling 10 units of the Legion L-Wedge Size 4 because they contained 5MM screws instead of the required 10MM screws.

    Product
    smith&nephew LEGION L-WEDGE, 10 MM DIS X 5 MM POS, SIZE 4, SCREW-ON FEMORAL WEDGE, REF 71421733, STERILE R Product The Revision Knee System Components are indicated for rheumatoid arthritis; post-traumatic arthritis; osteoarthritis; degenerative arthritis; and failed…
    Category
    Medical Device
    Distribution
    1 state