The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

11576–11600 of 27441

  • HighFDA (Devices)·Z-1799-2021·2021-06-16

    Alphatec Insignia Anterior Cervical Plate System screw failure recalled

    Alphatec is recalling its Insignia Anterior Cervical Plate System due to potential screw blocking mechanism failure during or after spinal surgery. The screw may disassociate intraoperatively or unlock postoperatively.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0116, Insignia, ACP, 1-Level, 16 mm, Rx Only, Non-Sterile, UDI: (01)00190376268422
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1810-2021·2021-06-16

    Anterior cervical plate system may lose screw locking mechanism during surgery

    Alphatec Spine's Insignia Anterior Cervical Plate System may have a defective screw blocking mechanism that could disassociate during or after surgery. The FDA has recalled 19 units distributed across 15 US states.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0238 Insignia, ACP, 2-Level, 38 mm, Rx Only, Non-Sterile, UDI: (01)00190376268392
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1840-2021·2021-06-16

    Myriad-LX Light Source Recalled Due to Burn and Occlusion Risk

    Nico Corp. is recalling 80 Myriad-LX Light Source units due to potential burn injury to patients from the distal tip of the fiber assembly and risk of delivery sleeve occlusion during surgical use.

    Product
    Myriad-LX Light Source-for delivery of light to the surgical field to enhance visualization of tissue during resection Part Number NN-7013 The Myriad-LX light source is a high-intensity 300W Xenon illuminator with a touch screen and digital dimming controls. The source is…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1825-2021·2021-06-16

    Cervical Plate System screw locking mechanism may fail during or after surgery

    Alphatec Insignia Anterior Cervical Plate System screw blocking mechanism may disassociate during surgery or unlock afterward. No injuries reported.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0474 Insignia, ACP, 4-Level, 74 mm, Rx Only, Non-Sterile, UDI: (01)00190376268699
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1794-2021·2021-06-16

    WishBone Medical Plate and Screw System Engineering Specification Nonconformity Recall

    Wishbone Medical is recalling WishBone Medical Plate and Screw System implants due to nonconformities in engineering specifications. The recall affects 60 units distributed in Virginia, Pennsylvania, and Indiana.

    Product
    WishBone Medical Plate and Screw System - Screw, Fixation, Bone, Washer, Bolt Nut. Part Number: PK-SMC0635NL-TI-US, PK-SMC0635NR-TI-US, PK-SMC0835NSL-TI-US, PK-SMC0835NSR-TI-US
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-1837-2021·2021-06-16

    Sunstar G.U.M Perioshield Oral Rinse Recalled Due to Bacterial Contamination

    Sunstar Americas is recalling SUNSTAR G.U.M PERIOSHIELD Oral Health Rinse 300mL (SKU 1775P, 1775R) due to potential contamination with Burkholderia bacteria.

    Product
    SUNSTAR G.U.M PERIOSHIELD Oral Health Rinse, 300mL, SKU numbers 1775P, 1775R - Product Usage: Help prevent and treat gingivitis caused by plaque build up Significantly reduce bleeding gums Protect teeth and gums from plaque causing bacteria.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1819-2021·2021-06-16

    Anterior Cervical Plate System Recalled for Screw Locking Failure

    Alphatec Spine is recalling its Insignia Anterior Cervical Plate System due to potential failure of the screw blocking mechanism during or after surgery that could compromise implant stability.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0356 Insignia, ACP, 3-Level, 56 mm, Rx Only, Non-Sterile, UDI: (01)00190376268590
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1818-2021·2021-06-16

    Alphatec Insignia Anterior Cervical Plate: Screw Blocking Mechanism May Disassociate

    Alphatec Spine is recalling the Insignia Anterior Cervical Plate System because the screw blocking mechanism may disassociate during or after spinal surgery.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0354 Insignia, ACP, 3-Level, 54 mm, Rx Only, Non-Sterile, UDI: (01)00190376268583
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1826-2021·2021-06-16

    Atec Insignia Cervical Plate Screw Locking Mechanism May Fail

    Alphatec Spine is recalling the Atec Insignia Anterior Cervical Plate System due to potential failure of the screw blocking mechanism that could cause separation during or after surgery.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0478 Insignia, ACP, 4-Level, 78 mm, Rx Only, Non-Sterile, UDI: (01)00190376268705
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1816-2021·2021-06-16

    Alphatec Insignia Cervical Plate System Screw Locking Mechanism May Disassociate or Unlock

    Alphatec Spine is recalling the Insignia Anterior Cervical Plate System due to a potential defect in the screw blocking mechanism that could disassociate or unlock during or after surgery.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0350 Insignia, ACP, 3-Level, 50 mm, Rx Only, Non-Sterile, UDI: (01)00190376268569
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1807-2021·2021-06-16

    Atec Insignia Anterior Cervical Plate System Recalled for Potential Screw Failure

    Alphatec Spine recalled the Atec Insignia Anterior Cervical Plate System due to potential failure of the screw blocking mechanism, which could disassociate during or after surgery.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0232 Insignia, ACP, 2-Level, 32 mm, Rx Only, Non-Sterile, UDI: (01)00190376268361
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1841-2021·2021-06-16

    Medline Tissue Recovery Instrument Sets Recalled for Sterility Assurance Failure

    Medline Industries is recalling Tissue Recovery Instrument Sets due to failure to meet sterility assurance levels. The instruments, used for tissue recovery in medical research and transplantation, were distributed in Wisconsin.

    Product
    Medline Tissue Recovery Instrument Set, Reorder #DYNJ64347A, packaged 3/case, Sterile, Rx. Convenience kit used to recover tissue, which can be used for medical research, education, or transplantation.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1808-2021·2021-06-16

    Alphatec Insignia Anterior Cervical Plate System Screw Mechanism May Disassociate

    Alphatec Spine is recalling Insignia Anterior Cervical Plate Systems due to a potential defect where the screw blocking mechanism may disassociate intraoperatively or unlock postoperatively. No patient injuries have been reported.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0234 Insignia, ACP, 2-Level, 34 mm, Rx Only, Non-Sterile, UDI: (01)00190376268378
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1839-2021·2021-06-16

    Medical Device Illumination Pack Recalled Due to Burn and Occlusion Risks

    Nico Corp. is recalling 439 NICO Myriad-LX Illumination Packs used in surgical procedures due to potential delivery sleeve occlusion and thermal burn injury from the fiber tip assembly.

    Product
    NICO Myriad-LX Illumination Pack: REF: NN-1000 Mvriad-LX Illumination Pack. 11ga REF: NN-1001 Mvriad-LX Illumination Pack. l3ga Intended to perform resection and removal of soft tissues and fluids under direct visualization accessories to the NICO Myriad System.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1800-2021·2021-06-16

    Atec Insignia Anterior Cervical Plate System screw mechanism failure

    Alphatec Spine is recalling the Atec Insignia Anterior Cervical Plate System because the screw blocking mechanism may disassociate or unlock during or after spine surgery, potentially compromising implant stability.

    Product
    Atec Insignia Anterior Cervical Plate System, REF 136-0117, Insignia, ACP, 1-Level, 17 mm, Rx Only, Non-Sterile, UDI: (01)00190376268439
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • CriticalFDA (Devices)·Z-1651-2021·2021-06-09

    Alaris Infusion Pump Module Bezel Repair Parts Recalled for Separation Risk

    FDA recalls 22 serviced Alaris Model 8100 infusion pump units with bezel components that may crack or separate, risking free flow, over-infusion, under-infusion, or treatment interruption. Units distributed to Indiana and Texas between September 2020 and February 2021.

    Product
    Alaris Infusion Pump Module, Model 8100, serviced/repaired by The Biomed Guys, with the impacted bezel repair part, TIPA-8100-4410 / Alaris 8100 Bezel.
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1620-2021·2021-06-09

    Leccurate SARS-CoV-2 Antigen Test Kit Recalled: Not FDA-Approved for U.S. Distribution

    The Leccurate SARS-CoV-2 Antigen Rapid Test Kit is being recalled because it was not authorized, cleared, or approved for marketing in the United States. Approximately 8.4 million units were distributed worldwide, including to U.S. states and territories.

    Product
    Leccurate SARS-CoV-2, Antigen Rapid Test Kit (Colloidal Gold Immunochromatography), 1 test, IVD. for the qualitative detection of antigen SARS-CoV-2 in clinical samples (nasal swab).
    Category
    Medical Device
    Distribution
    5 states
  • SevereFDA (Devices)·Z-1619-2021·2021-06-09

    Leccurate COVID-19 Antibody Test Kit Recalled for Unauthorized U.S. Distribution

    LEPU Medical has recalled the Leccurate SARS-CoV-2 Antibody Rapid Test Kit because it is not authorized, cleared, or approved for marketing in the U.S. Approximately 8.4 million units have been distributed worldwide.

    Product
    Leccurate SARS-CoV-2, Antibody Rapid Test Kit (Colloidal Gold Immunochromatography), 1 test, IVD. for qualitative detection of IgM and/or IgG antibodies to SARS-CoV-2 in human serum, plasma and venipuncture whole blood for use as an aid in identifying individuals with an…
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-1712-2021·2021-06-09

    ZVplasty Direct Access Trocar Recalled for Inadequate Sterilization

    Zavation is recalling ZVplasty Direct Access Diamond Tip Trocars (11 Gauge) because some units may not be adequately sterilized. These surgical instruments are used in orthopedic and spinal procedures.

    Product
    ZVplasty Direct Access Diamond Tip Trocar, 11 Gauge, REF VCF-1023-11. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1753-2021·2021-06-09

    Orthopedic Spinal Surgery Kit Recalled for Inadequate Sterilization

    Zavation is recalling InterV CurvePlus surgical kits because products distributed as sterile may not have been adequately sterilized. 36 units were distributed nationwide.

    Product
    InterV CurvePlus Kit, REF Numbers: a) INTVMC-15-FLDSK b) INTVMC-20-FLDSK. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1789-2021·2021-06-09

    Terumo HX2 and TCM Temperature Management Systems Recalled for Cleaning Protocol Issues

    Terumo recalled the HX2 and TCM temperature management systems used in cardiac surgery due to inability to validate an updated cleaning protocol. Users should discontinue use and properly dispose of affected devices.

    Product
    The Terumo HX2 Temperature Management System provides temperature control of two independent water circuits that directly controls the temperature of patient blood and cardioplegia solution during cardiovascular surgery. The system consists of a water tank, circulating pumps…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1775-2021·2021-06-09

    Synapse Cardiovascular software may incorrectly reuse patient database identifiers

    Fujifilm's Synapse Cardiovascular software versions 6.0.4 to 6.2.1 contain a defect in the Advanced Reporting function where previously assigned patient database identification numbers can be reused for new patients when specific patient merge operations are executed.

    Product
    Synapse Cardiovascular (Synapse CV). Software Versions: 6.0 to 6.2.1 The Synapse Cardiovascular image is a management and reporting system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1763-2021·2021-06-09

    ZVplasty 10G FLEX Kyphoplasty Spinal Device Recall Due to Sterilization Failure

    Zavation is recalling 19 units of ZVplasty 10G FLEX KYPHOPLASTY spinal devices because distributed units may not have been adequately sterilized, posing infection risk to patients.

    Product
    ZVplasty 10G, FLEX KYPHOPLASTY, REF VCF-1015-FLEX. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1751-2021·2021-06-09

    Zavation InterV 10G kyphoplasty kits recalled due to inadequate sterilization

    Zavation is recalling InterV 10G Kyphoplasty Kits because products distributed as sterile may not have been adequately sterilized. The recall affects 503 units distributed nationwide.

    Product
    InterV, 10G Kyphoplasty Kits, REF numbers: a) INTVM-10-DSK b) INTVM-10-SBK c) INTVM-15-DSK d) INTVM-15-DSKC e) INTVM-15-SBK f) INTVM-15-SIKBC g) INTVM-20-DSK h) INTVM-20-SBK. For use in Orthopedic / spinal procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide