The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

9851–9875 of 40056

  • SevereFDA (Devices)·Z-1958-2023·2023-07-05

    Teleflex Endotracheal Tubes Recalled Due to Connector Disconnection Risk

    Teleflex endotracheal tubes are recalled nationwide due to reported disconnection of the 15mm connector. The recall affects 1,750 units distributed across the US and Puerto Rico.

    Product
    Endotracheal Tube oral/nasal Magill, High Volume, Low Pressure Cuff, REF 112080050
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1942-2023·2023-07-05

    Teleflex endotracheal tubes recalled for connector disconnection risk

    Teleflex is recalling Preformed AGT Oral Endotracheal Tubes due to reports of 15mm connector disconnection. This Class I recall affects 23,395 units distributed nationwide.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111780045
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1957-2023·2023-07-05

    Preformed AGT Oral Endotracheal Tubes Recalled for Connector Disconnection

    TELEFLEX is recalling approximately 8,620 Preformed AGT Oral Endotracheal Tubes distributed nationwide due to reports of disconnection of the 15mm connector from the tube.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111781080
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1944-2023·2023-07-05

    Endotracheal Tube Connector Disconnection Recalls 14,480 Units

    Teleflex is recalling 14,480 Preformed AGT Oral Endotracheal Tubes nationwide due to reports of 15mm connector disconnection from the tube during use.

    Product
    Preformed AGT Oral Endotracheal Tube Murphy Eye, High Volume, Low Pressure Cuff, REF 111780055
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1930-2023·2023-07-05

    Endotracheal Tubes Recalled Nationwide for Connector Disconnection Risk

    Teleflex endotracheal tubes are being recalled due to reports of 15mm connector disconnection. The recall affects approximately 4,110 units distributed nationwide.

    Product
    Endotracheal Tube oral/nasal uncuffed/plain - Magill, REF 100380050
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2051-2023·2023-07-05

    Exactech Ergo Impactor Handle Recalled for Component Dislodgement

    Exactech Ergo Impactor Handles are recalled because the ball and spring in the locking mechanism may dislodge during disassembly or use. Approximately 784 devices are affected.

    Product
    Exactech Ergo Impactor Handle, Catalog #321-09-05.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-2049-2023·2023-07-05

    LINK Endo-Model Knee Prosthesis Segments Recalled for Out-of-Specification Defects

    The FDA has recalled 13 LINK Endo-Model knee prosthesis femoral segments because they may not meet manufacturing specifications. The defects were discovered through customer complaints.

    Product
    LINK Endo-Model Modular Knee Prosthesis System Femoral Segment, Size 4, Left
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-2036-2023·2023-07-05

    Vanta Implantable Neurostimulator May Become Unresponsive During Cardioversion

    Cardioversion procedures can damage electronics in Vanta implantable neurostimulators, making them unresponsive. Medtronic has received two complaints resulting in device removal surgeries.

    Product
    Vanta with AdaptiveStim Implantable Neurostimulator, Model 977006; spinal chord stimulation
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2020-2023·2023-07-05

    Orthopedic assembly screws with incorrect model number labeling and markings

    AEQUALIS FLEX REVIVE assembly screws were mislabeled during manufacturing, with some units marked as 0mm Standard actually being 0mm Short and vice versa. Surgeons must verify model numbers before use.

    Product
    AEQUALIS FLEX REVIVE Assembly Screw 0mm Short, Model Number ARS655118
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2002-2023·2023-07-05

    Perifix Epidural Anesthesia Kits Recalled for Incorrect Filter Straw

    B. Braun Medical recalled 16,070 Perifix epidural anesthesia kits that were assembled with an incorrect filter straw. The kits were distributed nationwide.

    Product
    Perifix¿ / Epidural anesthesia kit (10 count carton)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2004-2023·2023-07-05

    PushTracker E2 watch app may crash, disabling wheelchair motor controls

    Permobil's PushTracker E2 watch controls wheelchair power assist motors. The application may crash when running multiple processes, causing the motor to keep running and preventing users from stopping it using normal controls.

    Product
    PushTracker E2 component utilized with the SmartDrive MX2+ Power Assist Device (Part Numbers: MX2-32K, MX2-32P, MX2-32PK, MX2-33D, MX2-33P, MX2-33PK, MX2-33S, MX2-150, MX2-167, MX2-32D); a wearable watch that communicates with a SmartDrive Power Assist Device via the…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2006-2023·2023-07-05

    Voalte Patient Safety software may fail to alert caregivers of safety changes

    Baxter's Voalte Patient Safety software may permanently stop sending caregiver alerts for critical patient protocols like bed exit and siderail changes. Affected versions V4.0.000 through V4.0.401 are used with Centrella Beds.

    Product
    Voalte Patient Safety, Part Number 4.0, V4.0.000 to 4.0.401, used with the Centrella Bed
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2019-2023·2023-07-05

    Orthopedic Assembly Screws Recalled Due to Labeling and Size Swap Error

    Tornier recalled 55 AEQUALIS FLEX REVIVE Assembly Screws (Model ARS655101) due to a labeling swap where Standard-length units were marked Short, and vice versa. This could result in implantation of the wrong screw size during orthopedic surgery.

    Product
    AEQUALIS FLEX REVIVE Assembly Screw 0mm, Model Number ARS655101
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2050-2023·2023-07-05

    Exactech Shoulder GPS Impactor Handle Recalled for Locking Mechanism Defect

    Exactech is recalling 250 units of its Shoulder GPS Impactor Handle due to a defect where the ball and spring in the locking mechanism can dislodge during disassembly or impaction. The defect could affect the device's function during surgical use.

    Product
    Exactech Shoulder GPS Impactor Handle, Catalog #531-07-05.
    Category
    Medical Device
    Distribution
    27 states
  • HighFDA (Devices)·Z-2003-2023·2023-07-05

    Design Options Epidural Anesthesia Kit Recalled for Incorrect Filter Straw

    B. Braun Medical is recalling Design Options Epidural Anesthesia Kits because certain units were assembled with an incorrect filter straw. The recall affects approximately 3,560 kits distributed nationwide.

    Product
    Design Options¿ / Epidural anesthesia kit (10 count carton)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2024-2023·2023-07-05

    VERIGENE Clostridium difficile Nucleic Acid Test May Give False-Negative Results

    Luminex is recalling the VERIGENE C. difficile diagnostic test due to the possibility of false-negative results in rare instances caused by hydrophobic characteristics in specific FLOQSwab lots.

    Product
    VERIGENE Clostridium difficile Nucleic Acid Test, REF 30-002-022
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2035-2023·2023-07-05

    Sertera 14 Gauge Biopsy Device: Needle Detachment Risk

    Hologic's Sertera 14 Gauge Biopsy Device may experience inner needle detachment or discharge during use, which could delay breast biopsy surgery. The company is recalling 756 units nationwide.

    Product
    Sertera 14 Gauge Biopsy Device-intended to obtain percutaneous core biopsy samples from soft tissue and tumors of the breast REF: SERTERA-14
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2008-2023·2023-07-05

    ILLUMISITE Platform Console Incorrectly Converted with Non-Supplied Power Components

    A Medtronic ILLUMISITE Platform Console was modified from 220-240VAC to 120VAC using non-supplied power cord and fuses, creating electrical hazards. One unit was distributed to Taiwan.

    Product
    Medtronic ILLUMISITE Platform Console, Model Number ILS-1000-CS
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2005-2023·2023-07-05

    PushTracker E3 software failure may prevent stopping SmartDrive motor

    A software defect in the PushTracker E3 watch can cause the SmartDrive motor to run uncontrollably, and users may not be able to stop the device using tap controls. Approximately 6,196 units worldwide are affected.

    Product
    PushTracker E3 component utilized with the SmartDrive MX2+ Power Assist Device (Part Numbers: MX2-32K, MX2-32P, MX2-32PK, MX2-33D, MX2-33P, MX2-33PK, MX2-33S, MX2-150, MX2-167, MX2-32D); a wearable watch that communicates with a SmartDrive Power Assist Device via the…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-2043-2023·2023-07-05

    Access Hybritech p2PSA Reagent Recalled for Insufficient Blocking Reagent

    Beckman Coulter is recalling Access Hybritech p2PSA diagnostic reagent kits with insufficient blocking reagent concentration. Three lot numbers affecting 987 kits were distributed in the US and internationally.

    Product
    Access Hybritech p2PSA reagent, REF B03704 and REF A49752.
    Category
    Medical Device
    Distribution
    19 states
  • HighFDA (Devices)·Z-2039-2023·2023-07-05

    RayStation Radiation Therapy Software Recalled for Incorrect Dose Calculation

    RaySearch America is recalling RayStation radiation therapy treatment planning software due to a software bug that produces incorrect dose calculations. The error could lead to inappropriate treatment plans being approved for patient use.

    Product
    Radiation therapy software, RayStation standalone software treatment planning system. Model numbers: 8B, 8B SP1, 8B SP2, 9A, 9B, 9B SP1, 10A, 10A SP1 and 10B. Software versions: 8.1, 9.0, 9.1, 9.2, 10.0, 10.1.
    Category
    Medical Device
    Distribution
    4 states
  • HighFDA (Devices)·Z-2010-2023·2023-07-05

    Limacorporate Prima TT Orthopedic Baseplate Recalled for Manufacturing Defect

    Limacorporate is recalling 13 units of the Prima TT Genoid Modular Reverse TT Baseplate due to a manufacturing issue that may cause peripheral holes to be out of specification. Healthcare facilities should contact the manufacturer.

    Product
    REF 1975.14.800, Prima TT Genoid Modular Reverse TT Baseplate, Sterile R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2048-2023·2023-07-05

    Knee prosthesis femoral segment recalled for specification non-compliance

    Waldemar Link is recalling 16 units of a knee prosthesis femoral segment due to specification non-compliance discovered through customer complaints. Patients and healthcare facilities should contact the manufacturer for guidance.

    Product
    LINK Endo-Model Modular Knee Prosthesis System Femoral Segment, Size 4, Right
    Category
    Medical Device
    Distribution
    8 states
  • HighFDA (Devices)·Z-2023-2023·2023-07-05

    Verigene nucleic acid test kits recalled for rare false-negative results

    Luminex Corporation recalls Verigene nucleic acid test kits that may rarely produce false-negative results due to hydrophobic properties in certain FLOQSwab lots. False-negative results could fail to detect enteric pathogens in patient samples.

    Product
    Verigene Enteric Pathogens Nucleic Acid Test (EP), REF 30-002-023
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2025-2023·2023-07-05

    Philips Respironics V60 Ventilator recalled for potential gas pathway contamination

    DRE Medical Group recalled 22 Philips Respironics V60 ventilators due to potential contamination in the gas pathway of retrofitted units. These devices may pose a serious health risk to patients.

    Product
    Philips Respironics V60 Ventilator-Intended to mechanically control or assist patient breathing by delivering a predetermined percentage of oxygen in the breathing gas. Model Number: R1053618 and R1076709. These are retrofitted device.
    Category
    Medical Device
    Distribution
    2 states