The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

9401–9425 of 27441

  • HighFDA (Devices)·Z-1826-2022·2022-10-05

    Bentson Wire Guide Devices Recalled for Potential Sterility Compromise

    Cook Incorporated is recalling Bentson Wire Guide devices due to potential packaging defects that may compromise device sterility.

    Product
    Bentson Wire Guide, Guidewire (OUS ONLY); Reference Part Number: TSMB-35-145 (GPN G27041)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1815-2022·2022-10-05

    Olympus POWERSEAL 5MM Electrosurgical Sealer Recalled Due to Loose Retention Ring

    Olympus is recalling POWERSEAL 5MM electrosurgical sealers due to a component defect that may cause the rotation knob to loosen and delay surgical treatment.

    Product
    Olympus POWERSEAL 5MM, 44CM, CURVED JAW SEALER & DIVIDER, DOUBLE-ACTION Model Number: PS-0544CJDA. An electrosurgical device use in laparoscopic/minimally invasive or open surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1828-2022·2022-10-05

    Coons Interventional Guidewire Recall Due to Packaging Sterility Breach

    Cook Incorporated is recalling Coons Interventional Wire Guide devices because the chevron seal on packaging may be completely breached, compromising sterility. 1,236 units were distributed.

    Product
    Coons Interventional Wire Guide, Guidewire; Reference Part Number/GPN: THSF-35-145-COONS G02356 THSF-38-145-COONS G02324 THSF-35-180-COONS G02621 THSF-35-80-COONS G12268
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1823-2022·2022-10-05

    CooperSurgical incubator humidifier kit recall due to sterile barrier breach

    CooperSurgical is recalling 5,182 humidifier bottle and filter kits for BT37 Mark II incubators due to potential sterile barrier damage from packaging defects. This could result in use of unsterilized components, risking embryo contamination.

    Product
    Humidifier bottle and syringe filter kit (6 count of each) for the BT37 Mark II Benchtop Incubator (AY200246)
    Category
    Medical Device
    Distribution
    25 states
  • HighFDA (Devices)·Z-1818-2022·2022-10-05

    Diagnostic imaging software may lose patient information edits during processing

    Ambra PACS and ProViewer versions 3.22.2.0 and 3.22.3.0 have a software defect where patient information edits may be lost during initial study processing due to a race condition between database systems.

    Product
    Ambra PACS, Ambra ProViewer. Software for use as a primary diagnostic and analysis tool for diagnostic images.
    Category
    Medical Device
    Distribution
    43 states
  • HighFDA (Devices)·Z-1827-2022·2022-10-05

    Bentson Wire Guide Recalled for Packaging Defect Affecting Sterility

    Cook Incorporated is recalling Bentson Wire Guide guidewires due to packaging seal failures that may compromise sterility. The recall affects over 5,500 units distributed in the U.S. and internationally.

    Product
    Bentson Wire Guide (20cm Distal Flexibility with Softened Tip), Guidewire; Reference Part Number: TSFB-35-80 (GPN G01315) TSFB-35-145 (GPN G00691) TSFB-35-200 (GPN G01095)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1813-2022·2022-10-05

    Olympus POWERSEAL surgical sealer recalled for loose retention ring defect

    Olympus Corporation is recalling certain POWERSEAL electrosurgical sealers due to an out-of-specification component that may allow the retention ring to loosen, potentially delaying surgical treatment.

    Product
    Olympus POWERSEAL 5MM, 23CM, CURVED JAW SEALER & DIVIDER, DOUBLE-ACTION Model Number: PS-0523CJDA. An electrosurgical device use in laparoscopic/minimally invasive or open surgical procedures.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1829-2022·2022-10-05

    Cope Nitinol Guidewire Recalled Due to Packaging Sterility Breach

    Cook Incorporated is recalling Cope Mandril Wire Guide (Nitinol) devices because the packaging's chevron seal may be completely breached, potentially compromising sterility. The recall affects 1,501 US units and 380 international units.

    Product
    Cope Mandril Wire Guide (Nitinol), Nitinol Guidewire; Reference Part Number/GPN: PMG-18SP-60-COPE-NT-ST G09395 PMG-18SP-100-COPE-NT G08687 PMG-18SP-60-COPE-NT G08427
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1830-2022·2022-10-05

    Cope Mandril Wire Guide Guidewires Recalled for Packaging Seal Breach

    Cook Incorporated is recalling Cope Mandril Wire Guide stainless steel guidewires because the packaging chevron seal may be completely breached, compromising device sterility. Affected lots total 2,748 units in the US and 302 internationally.

    Product
    Cope Mandril Wire Guide (Stainless Steel), Stainless Steel Guidewire Reference Part Number/GPN PMG-18SP-60-COPE G05183 PMG-18SP-100-COPE G05822 PMG-18SP-125-COPE G10077
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1810-2022·2022-10-05

    Insulin Infusion Sets Recalled for Incorrect Dosing Information in Instructions

    Autosoft 90 insulin infusion sets are recalled because the instructions incorrectly state insulin fill values for two cannula sizes, potentially causing patients to receive fewer insulin units than intended.

    Product
    Autosoft 90, model numbers 1000282, 1002817, 1002818, 1002819, 1002820, 1002821, 1002822, 1002823, and 1002824. Infusion sets used with Tandem Insulin Subcutaneous Infusion Pump.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1762-2022·2022-10-05

    Laboratory Instrument Recalled for Class 1 Laser Safety Non-Compliance

    Malvern Panalytical is recalling 76 NanoSight LM10 laboratory instruments that do not comply with Class 1 laser safety requirements. The company is taking this action to prevent potential laser exposure risks.

    Product
    NanoSight LM10 fitted with LM14 module. A laboratory instrument for determination of particle characteristics (e.g. size).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1844-2022·2022-10-05

    Vinyl Connecting Tubes Recalled Due to Packaging Seal Breach

    Cook Incorporated is recalling Vinyl Connecting Tubes because of a complete breach of the chevron seal in the packaging, which may compromise device sterility.

    Product
    Vinyl Connecting Tube, Connecting Tube Reference Part Number/GPN CTU14.0-30-ST G02278 CTU14.0-40-ST G02327 CTU14.0-30 G02791 CTU14.0-50-ST G02464 C-CTU14.0-30-ST G02898
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1835-2022·2022-10-05

    Cook Incorporated Recalls Guidewire Due to Packaging Seal Breach

    Cook Incorporated is recalling Heavy Double Flexible Tipped Wire Guide devices due to potential packaging seal breach that may compromise sterility. Affected products were distributed domestically and worldwide.

    Product
    Heavy Double Flexible Tipped Wire Guide, Guidewire Reference Part Number/GPN: THDOC-35-60-0-3 G11949 C-HDOC-18-40-0-2 G09201 C-THDOC-18-40-0-2-HTS G26925
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1820-2022·2022-10-05

    Siemens IMMULITE Thyroid Test Kit Recalled for Falsely Low Results

    Siemens is recalling IMMULITE 2000 and XPi Thyroid Stimulating Immunoglobulins test kits due to a -23% negative bias that may produce falsely low results, potentially delaying diagnosis of autoimmune thyroid disease.

    Product
    IMMULITE 2000 and IMMULITE 2000 XPi Thyroid Stimulating Immunoglobulins (TSI) Siemens Material Number (SMN): 10876421 US; 10713448 (OUS)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1832-2022·2022-10-05

    Cook Guidewire Products Recalled Due to Compromised Sterile Packaging

    Cook Incorporated is recalling Fixed Core Wire Guide products due to potential breach of sterile packaging seals. Affected devices may have compromised sterility.

    Product
    Fixed Core Wire Guide, Guidewire Reference Part Number/GPN THSCF-25-180-3 G02165 TSCF-25-80-3 G00476
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1819-2022·2022-10-05

    VenaCure EVLT procedure kit fiber component fails dimensional specification

    Angiodynamics is recalling 40 VenaCure EVLT procedure kit units with fiber components that fail dimensional specifications. The defect may damage the sheath, necessitating removal from the patient and potential additional surgical intervention.

    Product
    VenaCure EVLT KIT WITH SPOTLIGHT OPS SHEATH 55CM Ref./ Catalog No.: EVLT55OPS (each box contains 5 Procedure Kits). For use in the treatment of varicose veins.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1855-2022·2022-10-05

    Medline ClearPro Suction Catheter Connector May Separate During Use

    Medline ClearPro closed suction catheters may have a connector that separates from the device during patient suctioning. The malfunction affects 65,320 units distributed nationwide and internationally.

    Product
    MEDLINE CLEARPRO DOUBLE SWIVEL CLOSED SUCTION CATHETER, flat peel pouch EA, 10 EA per Inner Carton (IC), 20 EA/2 Inner cartons per Case (CS). Labeled as follows: a. ET LENGTH DOUBLE SWIVEL, 12 Fr, Item Number/REF: DYNCPDS12; b. ET LENGTH DOUBLE SWIVEL, 14 Fr, Item Number/R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1779-2022·2022-10-05

    SunMed Pulset Syringes Recalled Due to Non-Sterile Spare Needles

    SunMed Holdings is recalling Pulset 3cc syringes with non-sterile spare needles that could cause skin infection or sepsis if used. The recall affects 53,560 units distributed across ten US states.

    Product
    Full Kit Pulset 3cc Syringe 23g x 1 Safety Tip 25u BH, REF Number 3373-91
    Category
    Medical Device
    Distribution
    10 states
  • HighFDA (Devices)·Z-1845-2022·2022-10-05

    Cook Lunderquist Ring Torque Wire Guide packaging breach may compromise sterility

    Cook Incorporated is recalling Lunderquist Ring Torque Wire Guides due to a complete breach in the chevron seal of the packaging, which may compromise device sterility. The recall affects multiple lot numbers distributed nationwide and internationally.

    Product
    Lunderquist -Ring Torque Wire Guide, Guidewire Reference Part Number/GPN THSF-35-125-THG G27031 THSF-35-145-THG G27033
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1857-2022·2022-10-05

    Medline ClearPro Trach T-Piece Suction Catheter May Separate at Connector

    Medline is recalling 136,080 ClearPro Trach T-Piece Closed Suction Catheters because the suction catheter can come apart from the connector during patient suctioning.

    Product
    MEDLINE CLEARPRO TRACH T-PIECE CLOSED SUCTION CATHETER, flat peel pouch EA, 10 EA per Inner Carton (IC), 20 EA/2 Inner cartons per Case (CS). Labeled as follows: a. TRACH T-PIECE, 14 Fr, Item Number/REF: DYNCPTP14; b. TRACH T-PIECE, 14 Fr, Item Number/REF: DYNCPTP14T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1821-2022·2022-10-05

    OSSUR Power Knee Prosthetics Recalled for Battery Dislodgement Risk

    OSSUR Power Knee prosthetics are being recalled because the battery may dislodge from the device. Approximately 190 units are affected across the United States.

    Product
    OSSUR Power Knee REF PKA10003 OSSUR Power Knee REF PKA10003 OSSUR Power Knee REF PKA01001L OSSUR Power Knee REF PKA01001T
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1834-2022·2022-10-05

    Cook Guidewire Devices Recalled for Packaging Defect and Sterility Compromise

    Cook Incorporated is recalling fixed core wire guide devices due to packaging defects that may compromise device sterility. Approximately 5,669 units were distributed in the US and 5,286 internationally.

    Product
    Fixed Core Wire Guide (Straight), Guidewire Reference Part Number/GPN: C-SF-18-30 G02261 C-SF-25-40 G01937 TSF-18-260 G00590 C-SF-25-50 G01938 TSF-35-180 G00652 C-SF-18-40 G02255 TSF-25-145 G00617 TSF-32-145 G00638 C-SF-15-50 G02274 TSF-18-145 G00587 TSF-18-50 G00593
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1773-2022·2022-09-28

    Ethicon PDS II Surgical Sutures Recalled for Incorrect Material

    Ethicon recalls PDS II surgical sutures distributed in Japan due to potential incorrect material composition that could affect treatment outcomes. No injuries have been reported.

    Product
    PDS II (polydioxanone) Suture, Product Code Z771D 4-0 PDS Suture, Violet, 8x18" (45cm), SH-1 Control Release Needles
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1752-2022·2022-09-28

    BD MaxGuard Extension Set labeled with incorrect expiration year 2027

    46,900 BD MaxGuard Extension Sets are labeled with expiration year 2027 but should expire in 2025. Using expired product may compromise integrity and cause leaks, risking infection.

    Product
    BD MaxGuard Extension Set with 4-way stopcock, REF: M4058
    Category
    Medical Device
    Distribution
    39 states
  • HighFDA (Devices)·Z-1753-2022·2022-09-28

    BD MaxGuard Extension Set Mislabeled With Wrong Expiration Date

    BD MaxGuard Extension Set units have labels listing 2027 as the expiration year instead of 2025. Using expired medical devices may compromise product integrity and increase the risk of leaks and infection.

    Product
    BD MaxGuard Extension Set, REF: ME1069
    Category
    Medical Device
    Distribution
    39 states