The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

4001–4025 of 27346

  • SevereFDA (Devices)·Z-0075-2025·2024-10-30

    Aespire 100 anesthesia machine breathing circuit misconnection FDA recall

    Datex-Ohmeda Aespire 100 anesthesia machines are recalled due to potential misconnection of breathing circuit limbs to the Auxiliary Common Gas Outlet port, which could impair anesthesia or ventilation delivery.

    Product
    Aespire 100. This anesthesia gas machine is intended to provide general inhalation anesthesia and ventilatory support to patients and are to be used only by medical professionals trained and qualified in the administration of general anesthesia.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0082-2025·2024-10-30

    Aisys CS2 Anesthesia Machine Recall: Breathing Circuit Misconnection Risk

    Datex-Ohmeda is recalling approximately 15,739 Aisys CS2 anesthesia machines worldwide. A breathing circuit limb may be mistakenly connected to the Auxiliary Common Gas Outlet (ACGO) port instead of the intended connection point.

    Product
    Aisys CS2. This anesthesia gas machine is intended to provide general inhalation anesthesia and ventilatory support to patients and are to be used only by medical professionals trained and qualified in the administration of general anesthesia.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0078-2025·2024-10-30

    Anesthesia Gas Machine Recall: Breathing Circuit Misconnection Risk

    Datex-Ohmeda is recalling Avance anesthesia gas machines worldwide due to a potential hazard if a patient's breathing circuit is incorrectly connected to the Auxiliary Common Gas Outlet port during setup.

    Product
    Avance. This anesthesia gas machine is intended to provide general inhalation anesthesia and ventilatory support to patients and are to be used only by medical professionals trained and qualified in the administration of general anesthesia.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-0218-2025·2024-10-30

    Baxter TruSystem 7000 Operating Tables Recalled for Electrical Short-Circuits

    Baxter Healthcare is recalling 13 TruSystem 7000 operating tables because their batteries and connectors experienced electrical short-circuits and emitted smoke.

    Product
    Baxter Operating Table TruSystem 7000 U14 (MBW) V, Product code REF 2065386
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0198-2025·2024-10-30

    Smiths Medical Recalls TranStar KIDS KIT Blood Sample Kits

    Smiths Medical ASD, Inc. is recalling 900 units of medex TranStar KIDS KIT 31IN. CLOSED BLOOD SAMPLE KIT due to a manufacturing defect that may cause inaccurate pressure monitoring.

    Product
    medex TranStar KIDS KIT 31IN. CLOSED BLOOD SAMPLE KIT with 30cc/hr Flush Device 10/EA, Product Code REF MX9544
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0224-2025·2024-10-30

    Quantum Perfusion Systems CPB Roller Pumps Recalled for Mechanical Locking Defect

    Spectrum Medical Ltd. is recalling 172 Quantum Perfusion Systems CPB Roller Pumps due to an out-of-tolerance ratchet and pawl defect preventing proper bobbin locking. This defect may affect blood circulation control during cardiac surgery.

    Product
    Quantum Perfusion Systems for CPB, Roller Pumps use peristaltic action to propel blood through the venous and arterial circuit tubing. Catalog Numbers: a) 51-000013-00, b) 51-000008-00
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0142-2025·2024-10-30

    Internal Defibrillation Paddles Recalled for Cracks and Separation

    Physio-Control is recalling sterilizable internal defibrillation paddles (LP20 and LP15 models) due to cracking and over-molding separation. The defects may prevent proper device function during critical cardiac emergency treatment.

    Product
    STERILIZABLE INTERNAL DEFIBRILLATION PADDLES REF LP20 STERILIZABLE INTERNAL DEFIBRILLATION PADDLES REF LP15 Defibrillation is indicated for the termination of certain potentially fatal arrhythmias, such as ventricular fibrillation and symptomatic ventricular tachycardia. Sync
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0170-2025·2024-10-30

    Medline Tubal Ligation Kits Recalled for Potential Sterility Compromise

    Medline is recalling certain tubal ligation procedure kits due to potential loss of sterility if the pouch seal becomes compromised during storage or handling.

    Product
    Medline TUBAL LIGATION PACK, REF DYNJ66230B; medical procedure convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0220-2025·2024-10-30

    AD-TECH Spencer Probe Depth Electrode recalled for MRI safety label discrepancy

    Ad-Tech is recalling A-style depth electrodes due to incorrect MRI safety labeling. Devices were labeled as MR Conditional when they should be labeled MR Unsafe.

    Product
    AD-TECH Spencer Probe Depth Electrode, REF SD06R-AP58X-000 6-Contact 1.12mm (A style) Depth Electrode
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0202-2025·2024-10-30

    medex TranStar Pressure Transducer Stopcock Recalled for Manufacturing Defect

    Smiths Medical is recalling the medex TranStar Stopcock due to a manufacturing defect that can cause inaccurate pressure monitoring, interrupted pressure monitoring, or inability to zero the device.

    Product
    medex TranStar Stopcock w/Ext. 10/EA, Product Code REF MXG300242
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0211-2025·2024-10-30

    Baxter Operating Table TruSystem 7000 Recalled for Battery Short-Circuit Risk

    Baxter Healthcare Corporation is recalling the TruSystem 7000 Operating Table due to battery and connector short-circuits that can emit smoke, creating fire and electrical hazards during surgery.

    Product
    Baxter Operating Table TruSystem 7000, Product code REF 1841046
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0164-2025·2024-10-30

    Medline catheter procedure kits recalled for potential sterility compromise

    Medline is recalling 8,830 medical procedure convenience kits with potential breather pouch seal failure that could allow non-sterile product use.

    Product
    Medline brand medical procedure convenience kits, labeled as: a) TRAY ADD A CATH FOL UM MF 10ML, REF DYND150200S; b) TRAY FOL LATX UM COUD 16FR MF, REF DYND150216CS; c) TRAY FOLEY LTX 16FR 10ML UM MF, REF DYND150216S; d) TRAY FOLEY LTX 16FR 10ML UM MF, REF DYND150216S;
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0225-2025·2024-10-30

    Endoscopic Dilation Balloon Mislabeled with Incorrect Size Information

    Olympus EZDilate Wire Guided Balloons with Lot 408987 have mislabeled sizing information. The device label states 11 mm, 12 mm, and 13 mm, but actual balloon sizes are 8.5 mm, 9.5 mm, and 10.5 mm, which may result in prolonged surgery.

    Product
    EZDilate Wire Guided Balloon- Indicated for use in adult and adolescent (> 12 years) populations to endoscopically dilate strictures of the alimentary tract. It is also indicated in adults for endoscopic dilatation of the Sphincter of Oddi with or without prior sphincterotomy.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-0011-2025·2024-10-30

    CADD Medication Cassette Reservoir Recalled for Weld Defect Risk

    Smiths Medical is recalling 385,558 units of CADD Medication Cassette Reservoirs due to a weakened weld joint that could cause medication leakage. Affected units were distributed worldwide; users should discontinue use of recalled lot numbers immediately.

    Product
    CADD Medication Cassette Reservoir, 100mL, FS, Product Code 21-7302-24
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0221-2025·2024-10-30

    AD-TECH Spencer Probe Depth Electrodes recalled for MRI safety labeling error

    Ad-Tech Medical Instrument Corporation is recalling 14 units of its AD-TECH Spencer Probe Depth Electrodes due to an incorrect MRI safety label. The devices were labeled as MRI Conditional when they are actually MRI Unsafe, creating a risk of misuse.

    Product
    AD-TECH Spencer Probe Depth Electrode, REF SD08R-AP58X-000 8-Contact 1.12mm (A style) Depth Electrode
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0012-2025·2024-10-30

    CADD Medication Cassette Reservoir recalled for potential medication leakage

    Smiths Medical is recalling CADD Medication Cassette Reservoirs (100mL) due to a production equipment malfunction that may weaken the weld joint between the medication bag and tubing, potentially causing medication leakage. The recall affects 26,160 units distributed worldwide.

    Product
    CADD Medication Cassette Reservoir, 100mL, FS, YELLOW, Product Code 21-7300-24
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0210-2025·2024-10-30

    Baxter TruSystem 7000 Operating Tables: Battery Short-Circuits, Smoke Risk

    Baxter Healthcare is recalling 6,045 TruSystem 7000 U operating tables worldwide due to battery and connector failures that can cause electrical short-circuits and emit smoke.

    Product
    Baxter Operating table TruSystem 7000 U (MB), Product codes: a) REF 1604786; b) REF 1604788; c) REF 1723633
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0180-2025·2024-10-30

    Medline EYE PACK Medical Kits Recalled for Potential Non-Sterile Packaging

    Medline is recalling 160 units of EYE PACK medical procedure kits due to potential compromises in sterilization. If the vendor seal on the breather pouch is opened or unsealed, the contents may become non-sterile.

    Product
    Medline EYE PACK, REF LYN036EPESB; medical procedure convenience kit
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0165-2025·2024-10-30

    Medline Medical Procedure Kits Recalled Due to Potential Non-Sterility Risk

    Medline is recalling approximately 1,048 medical procedure convenience kits that may become non-sterile if their protective pouch seal is compromised. The affected kits were packaged with breather pouches from lot 323080002.

    Product
    Medline brand medical procedure convenience kits, labeled as: a) PLASTIC PACK, REF DYNJ42735A; b) DR SELEM PACK, REF DYNJ43457; c) BREAST PK TEGH-LF, REF DYNJ46717A; d) BREAST PK TEGH-LF, REF DYNJ46717A; e) BREAST BIOPSY-LF, REF DYNJ53205B; f) BREAST BIOPSY-LF, REF D
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0192-2025·2024-10-30

    Pressure Monitoring Kit Recalled for Manufacturing Defect and Malfunction

    The medex TranStar 84in Single Monitoring Kit is being recalled due to manufacturing defects in its disposable pressure transducer. The defect may cause inaccurate pressure readings, interruption of monitoring, or inability to zero the device.

    Product
    medex TranStar 84in (213cm) Single Monitoring Kit 10/EA, Product Code REF MX9505T
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0201-2025·2024-10-30

    Blood Sample Pressure Kit Recalled for Monitoring Defects

    Smiths Medical recalls the medex TranStar KIDS KIT blood sample kit due to manufacturing defects in the pressure transducer that may cause inaccurate or interrupted pressure monitoring, or prevent proper device calibration.

    Product
    medex TranStar KIDS KIT 10IN. CLOSED BLOOD SAMPLE KIT with 30cc/hr Flush Device 10/EA, Product Code REF MX9548
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0014-2025·2024-10-30

    CADD Medication Cassette Reservoir weld defect poses leakage risk

    Smiths Medical ASD is recalling 41,964 CADD Medication Cassette Reservoirs (50mL) due to weakened weld joints that could cause medication leakage. The defect results from a production equipment malfunction.

    Product
    CADD Medication Cassette Reservoir, 50mL, Product Code 21-7001-24
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-0137-2025·2024-10-30

    SynchroMed II Infusion Pump Recalled Due to Memory Data Corruption

    Medtronic Neuromodulation is recalling the SynchroMed II Infusion Pump (Product Number 8637-20) due to potential data corruption in the pump's memory that could prevent proper interrogation of the device.

    Product
    SynchroMed II Infusion Pump. Product Number: 8637-20
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0154-2025·2024-10-30

    Medline Medical Procedure Convenience Kits Recalled for Potential Sterility Issue

    Medline is recalling 312 medical procedure convenience kits due to potential sterility issues if the breather pouch seal is opened or damaged. The affected kits were distributed in the US, Canada, and Panama.

    Product
    Medline brand, medical procedure convenience kits, labeled as: a) SET UP PACK, REF DYNJ36320A; b) ANGIOGRAM WRO-LF, REF DYNJ41876B
    Category
    Medical Device
    Distribution
    Distributed nationwide