The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

38001–38025 of 40449

  • HighFDA (Devices)·Z-1737-2013·2013-07-24

    SpineFrontier Recalls KRD1 PedFuse Rods Due to Fatigue Testing Failures

    SpineFrontier, Inc. is recalling KRD1 PedFuse Rods because one rod in each of two test constructs failed to meet fatigue requirements during dynamic compression testing.

    Product
    KRD1 PedFuse Rods, Model: IM80100-13 Rev B Product Usage: Pedicle rods are cylindrical rods which act as a linking mechanism between pedicle screws. The rod sits with the pedicle screw tulip and they are locked into place with a set screw or locking cap. The rod may be…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1740-2013·2013-07-24

    Stryker TPS Universal Driver Recalled for Unintended Activation Risk

    Stryker is recalling TPS Universal Drivers due to incorrect programming that may cause unintended activation, posing a risk of injury to patients or users.

    Product
    Stryker TPS Universal Driver REF 5100- 99 Rx , The Stryker Total Performance System (TPS) is intended for use in the cutting, drilling, reaming, decorticating and smoothing of bone and other bone related tissues for a variety of applications such as ENT, dental orthopedic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1729-2013·2013-07-24

    KooJoo Trading Company Recalls Unsterilized Safety Lancets

    KooJoo Trading Company is recalling specific lots of Odyssey safety lancets because they were not sterilized within the established validation dose range.

    Product
    Safety Lancets - Odyssey, Button Activated; Tri- Bevel Tip for Virtually Painless Sampling; Needle automatically retracts, No lancing device required. 26G - Single Use Only, Made In Korea Distributed by Hummingbird Medical, Savannah, GA 100 count Boxes; 40 boxes per…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1749-2013·2013-07-24

    Edwards Lifesciences Recalls Suction Wands Due to Plastic Particulate

    Edwards Lifesciences is recalling specific models of rigid suction wands because plastic particulate was found inside the sterile pouch and within the wand.

    Product
    Edwards Lifesciences Suction Wand, models S099 and S0998B Suction wands are intended for hand held use and pericardial sumps are intended for stationary use in removing excess fluid from the surgical field.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1741-2013·2013-07-24

    Stryker CORE Universal Driver Recalled for Unintended Activation Risk

    Stryker is recalling 11 CORE Universal Drivers because incorrect programming parameters may cause unintended activation, posing a potential injury risk to patients and users.

    Product
    CORE Universal Driver REF 5400- 99 Rx Only This drill may also be used with theTotal Performance System (TPS").The Stryker Total Performance System (TPS) is intended for usein the cutting, drilling, reaming, decorticating and smoothing of bone and other bone related tissues…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1750-2013·2013-07-24

    Siemens AXIOM Artis zee/zeego Systems Recalled for Generator Power Supply Defect

    Siemens is recalling 23 AXIOM Artis zee/zeego angiographic x-ray systems because a tolerance problem in the generator power supply may cause the generator to fail.

    Product
    Siemens AXIOM Artis zee/zeego systems equipped with generator A100 Plus Product Usage: Angiographic x-ray system
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1751-2013·2013-07-24

    Hospira Recalls Symbiq IV Pump Sets Due to Air-in-Line Alarm Risk

    Hospira is recalling Symbiq IV pump sets because a defective ball valve may fail to seal, causing air-in-line alarms during fluid administration.

    Product
    LifeShield; Sterile; Rx only; List No. 19666-28; SYMBIQ PUMP SET, CONVERTIBLE PIN, PIGGYBACK, 2 CLAVES PORTS AND OPTION LOK, NON-DEHP; NOMINAL LENGTH: 97 IN (249 CM); PRIMING VOLUME: 14 ML; For the administration of I.V. fluids; Made in Costa Rica; Hospira, Inc., Lake Forest, IL…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1734-2013·2013-07-24

    Terumo Recalls CDI 500 Blood Parameter Monitoring System Due to Software Inaccuracies

    Terumo is recalling 3,972 CDI 500 Blood Parameter Monitoring Systems because software inaccuracies may affect monitoring during cardiopulmonary bypass.

    Product
    CDI Blood Parameter Monitoring System 500 with Venous blood parameter module. Intended for use during cardiopulmonary bypass procedures when continuous monitoring of arterial and/or venous pH, PCO2, PO2, K+, oxygen saturation, hematocrit, hemoglobin, and temperature are…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1727-2013·2013-07-24

    Roche B-CrossLaps/serum Immunoassay Recalled for Unreliable Biotin Interference Claims

    Roche Diagnostics is recalling B-CrossLaps/serum immunoassays because internal investigations showed the package insert's claims regarding biotin interference and sample stability could not be reproduced.

    Product
    B-CrossLaps/serum (B-CTx in serum) REF 11972308 160 100 tests Immunoassay for the in vitro quantitative determination of degradation products of type I collagen in human serum and plasma as an aid in assessing bone resorption. The test may be used as an aid in monitoring…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1731-2013·2013-07-24

    Terumo Recalls CDI 500 Blood Parameter Monitoring System Due to Software Error

    Terumo is recalling the CDI 500 Blood Parameter Monitoring System because software inaccuracies were found in the algorithm. A software update is being developed to correct the issue.

    Product
    CDI Blood Parameter Monitoring System 500 with Arterial blood parameter modules and Hematocrit/Saturation probe. Intended for use during cardiopulmonary bypass procedures when continuous monitoring of arterial and/or venous pH, PCO2, PO2, K+, oxygen saturation, hematocrit…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1742-2013·2013-07-24

    Stryker RemB Electric Universal Driver Recalled for Unintended Activation

    Stryker is recalling nine RemB Electric Universal Drivers because incorrect programming parameters may cause unintended activation, posing a risk of injury to patients or users.

    Product
    RemB Electric Universal Driver REF 6400-099-000 For use with the CORE and TPS System sRx Only The RemB Electric Universal Driver is intended for use with the Consolidated Operating Room Equipment (CORE TM) System. When used with a variety of accessories, the RemB Electric…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1730-2013·2013-07-24

    Terumo Recalls CDI 500 Blood Parameter Monitoring System for Software Error

    Terumo is recalling the CDI 500 Blood Parameter Monitoring System due to software algorithm inaccuracies. A software update is being developed to correct the issue.

    Product
    CDI Blood Parameter Monitoring System 500 with Arterial and Venous blood parameter modules and Hematocrit/Saturation probe. Intended for use during cardiopulmonary bypass procedures when continuous monitoring of arterial and/or venous pH, PCO2, PO2, K+, oxygen saturation…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1745-2013·2013-07-24

    Synthes Recalls Multi Vector Distractor Pin Holding Clamps Due to Binding

    Synthes USA is voluntarily removing Multi Vector Distractor Pin Holding Clamps because the clamp and nut construct may fail to engage threads and bind.

    Product
    Multi Vector Distractor Pin Holding Clamp, limited bone stock The holding clamp is part of the Multi Vector Distractor which cis used for mandibular bone lengthening, including conditions such as congenital mandibular deficiencies or post-traumatic defects. The Multi Vector…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1735-2013·2013-07-24

    Paa Laboratories Recalls Fetal Bovine Serum Due to Mislabeling

    Paa Laboratories is recalling approximately 280,000 liters of Fetal Bovine Serum because some products labeled as pure may contain added adult Bovine Serum Albumin.

    Product
    Various types of Fetal Bovine Serum Bovine sourced Animal Sera for in-vitro diagnostic device and as a growth promoting nutrient in cell culture systems.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1728-2013·2013-07-24

    Karl Storz Balloon Catheter Recalled for Potential Sterility Compromise

    Karl Storz Endoscopy America is recalling 27023WU Balloon Catheters because packaging defects may compromise sterility. The recall affects 40 units distributed to five US states.

    Product
    27023WU Balloon Catheter, 3 Fr., 2/pkg, sterile, contains latex. The RUSCH ureter occlusion catheter is indicated for the routine occlusion of the ureter to prevent the movement of stone fragments during treatment. The coaxial catheters will also allow simultaneous drainage…
    Category
    Medical Device
    Distribution
    5 states
  • ModerateFDA (Devices)·Z-1744-2013·2013-07-24

    Zeiss Microscope Polarizer D Component Recalled for Misaligned Plate

    Carl Zeiss Microscopy is recalling Polarizer D components for upright Zeiss microscopes due to a misaligned full-wave plate.

    Product
    Polarizer D Fixed w/Rotating Red 1 lambda plate. Utilized in upright Zeiss microscopes to aid in diagnosis by means of color variation.
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-1752-2013·2013-07-24

    Baxter Recalls ExactaMix Compounders Due to Battery Clock Reset

    Baxter Healthcare is recalling ExactaMix 1200 and 2400 compounders because a battery failure causes the internal clock to reset to midnight on December 31, 2010.

    Product
    ExactaMix 1200 and 2400 Compounders. Used as an automated pumping system that compounds multiple sterile ingredients into a finished solution.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1726-2013·2013-07-24

    Synthes CMF Distraction System Recalled for Misalignment

    Synthes USA HQ, Inc. is voluntarily recalling 10 units of the Synthes CMF Distraction System due to a misalignment issue that prevents the attachment of specific foot plates.

    Product
    Synthes CMF Distraction System The product is intended for use as a bone stabilizer and lengthening (and/or transport) device for correction of congenital deficiencies or post-traumatic defects of the mandibular body and ramus, where gradual bone distraction is required. It…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1732-2013·2013-07-24

    Terumo Recalls CDI 500 Blood Parameter Monitoring Systems

    Terumo is recalling CDI 500 Blood Parameter Monitoring Systems because software contains unused accuracy correction factors for hematocrit and saturation calculations.

    Product
    CDI Blood Parameter Monitoring System 500 with Arterial and Venous blood parameter modules. Intended for use during cardiopulmonary bypass procedures when continuous monitoring of arterial and/or venous pH, PCO2, PO2, K+, oxygen saturation, hematocrit, hemoglobin, and…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1748-2013·2013-07-24

    Boston Scientific Recalls Alair Bronchial Thermoplasty Catheters Due to Labeling Error

    Boston Scientific is recalling 35 units of Alair Bronchial Thermoplasty Catheters because the expiration date on the inner tray is incorrect.

    Product
    Alair Bronchial Thermoplasty Catheter, Bronchial Thermoplasty System; Material Number: M005ATS25010, Catalog Number: ATS 2-5. Product is manufactured and distributed by Boston Scientific Corporation (BSC), Sunnyvale, CA The Alair Bronchial Thermoplasty System (including the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1743-2013·2013-07-24

    Technidata TDHistology Software Recall for Electronic Transmission Symbol Errors

    Technidata is recalling TDHistology/Cytology software because unsupported symbols in Microsoft Word reports may cause errors during electronic transmission of results.

    Product
    TDHistology/Cytology Classification name: Calculator/data processing module for clinical use (862.2100). Intended use: Laboratory Information System (L.I.S)
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-1699-2013·2013-07-17

    Biomet Recalls Oxford Fixed Bearing Partial Knee Components

    Biomet is recalling 22 Oxford Fixed Bearing Partial Knee components due to a design defect that may cause anterior impingement.

    Product
    REF 154204 Oxford Fixed Bearing Partial Knee Cemented Lateral Tibia Size A7 ARCOM UHMWPE / CO-CR-MO Alloy Only for use in Lateral compartment Sterile R The Oxford Fixed Bearing Knee is a Partial knee replacement system consisting of a femoral component and a fixed bearing…
    Category
    Medical Device
    Distribution
    4 states
  • SevereFDA (Devices)·Z-1668-2013·2013-07-17

    Medtronic MiniMed Paradigm Insulin Infusion Sets Recalled for Malfunction Risk

    Medtronic MiniMed is recalling Paradigm insulin infusion sets because they may malfunction and deliver incorrect insulin volumes if exposed to fluids.

    Product
    Medtronic MiniMed Paradigm Insulin Infusion Sets The Paradigm infusion sets are intended for use with Paradigm insulin infusion pumps.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1667-2013·2013-07-17

    Bryan Medical Recalls Mislabeled Pediatric Tracheostomy Tubes

    Bryan Medical Inc is recalling 5 units of Tracoe Mini 3.0mm pediatric tracheostomy tubes because they were mislabeled as smaller infant tubes.

    Product
    Tracoe Mini 3.0mm Tube, for pediatric use. Pediatric tracheostomy tube used to provide safe airway access.
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-1685-2013·2013-07-17

    Integra Hallu-Fix Cannulated Screw Driver Recall Due to Tip Breakage

    Integra LifeSciences is recalling Hallu-Fix cannulated screw drivers and tips because the tips have been reported to break during surgery.

    Product
    Integra Hallu-Fix cannulated screw driver (model number P/N 129733ND) and cannulated screwdriver tip (model number P/N 129735ND). Indicated for use in fixation of fractures, osteotomies and arthrodesis of the first metatarso-phalangeal joint.
    Category
    Medical Device
    Distribution
    Distributed nationwide