The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

35901–35925 of 40449

  • ModerateFDA (Devices)·Z-1540-2014·2014-05-14

    Alere Triage BNP Test Recalled for Potential Out-of-Range Results

    Alere San Diego, Inc. is recalling specific lots of the Alere Triage BNP Test because they may not recover within range when tested with certain controls.

    Product
    Alere Triage BNP Test for the Beckman Coulter Access Family of Immunoassay Systems, Model Number 98200, Lot Numbers: 329599, 331265. The Alere Triage BNP test is intended to be used as an aid in the diagnosis of congestive heart failure (heart failure), as an aid in the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-1545-2014·2014-05-14

    Siemens CLINITEK Status+ Analyzer Recalled for Uncleared Marketing Status

    Siemens Healthcare Diagnostics Inc is recalling CLINITEK Status+ Analyzers with Sample Interference Notes enabled because they were not cleared for US marketing.

    Product
    CLINITEK Status+ Analyzer (portable urine chemistry analyzer). Catalog number 10490946.
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-1513-2014·2014-05-07

    Brainlab ExacTrac 6.0 Radiation Positioning System Recalled for Targeting Error

    Brainlab AG is recalling ExacTrac 6.0 systems because they may position patients to unintended radiation targets, potentially delivering dose to the wrong location.

    Product
    ExacTrac 6.0 is a patient positioning and monitoring system. Model/catalogue numbers: 20833B EXACTRAC 6.0 IR POSITIONING SOFTWARE 49936 ET SOFTWARE UPDATE 6.0.X TO 6.0.3 49926B ET UPGRADE SOFTWARE 3.X TO 6.0 (IR+XR) 49934A EXACTRAC UPGRADE 5.5 TO 6.0 BASIC 49927B ET…
    Category
    Medical Device
    Distribution
    7 states
  • SevereFDA (Devices)·Z-1482-2014·2014-05-07

    Hospira Recalls Acclaim Infusion Pumps Due to Broken Door Assemblies

    Hospira is recalling 13,218 Abbott Acclaim Infusion Pumps because broken door assemblies may prevent the door from closing, potentially causing unrestricted flow or therapy delays.

    Product
    Abbott Acclaim Infusion Pump Designed to deliver parenteral infusions including whole blood or red blood cell components and enteral fluids using a wide variety of standard administration sets and fluid containers.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1483-2014·2014-05-07

    Hospira Acclaim Encore Infusion Pump Recall for Broken Door Assemblies

    Hospira is recalling 13,218 Acclaim Encore infusion pumps because broken door assemblies may prevent proper closure, causing unrestricted flow or therapy delays.

    Product
    Hospira Acclaim Encore Infusion Pump Designed to deliver parenteral infusions including whole blood or red blood cell components and enteral fluids using a wide variety of standard administration sets and fluid containers.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1512-2014·2014-05-07

    Hospira Recalls GemStar Docking Stations Due to Power and Voltage Issues

    Hospira is recalling GemStar Docking Stations because they may cause infusion pumps to fail to power up or stop infusions due to voltage errors.

    Product
    GemStar Docking Station, used with GemStar infusion pump, in combination with other GemStar accessories such as the GemStar Lock Box and patient bolus cord. The docking station is also used for hosting the GemStar pump for general infusions. List Numbers: 13075-XX-XX.
    Category
    Medical Device
    Distribution
    53 states
  • HighFDA (Devices)·Z-1515-2014·2014-05-07

    Acumed Osteo-Clage System Recalled for Non-Specification Stainless Steel

    Acumed LLC is recalling the Osteo-Clage System because the stainless steel used in manufacturing was not within specifications.

    Product
    The Osteo-Clage System consists of stainless steel cable/sleeves and compression plates. . 2.0 mm x 850mm SS Cable/Sleeve; Part Number 01-0020-S 2.0 mm SS Sleeve Only; Part Number 01-0022-S 8, 7 hole, SS compression plate; Part Number 02-2007-S 10, 9 hole, SS compression…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1533-2014·2014-05-07

    GE Healthcare Recalls MRI Scanners Due to Cradle Release Malfunction

    GE Healthcare is recalling 1,548 MRI scanners because a malfunctioning cradle release mechanism could delay or impede patient egress from the system.

    Product
    GE Healthcare Discovery MR450, Discovery MR750, Optima MR450w, Optima MR450w equipped with the GEM option, Discovery MR750w, and Discovery MR750w equipped with the GEM option products. Affected devices are whole body magnetic resonance scanners indicated for use as a…
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-1510-2014·2014-05-07

    Philips ADAC Nuclear Gamma Cameras Recalled for Potential Patient Contact

    Philips Medical Systems is recalling 1,043 ADAC nuclear gamma cameras because a belt slippage issue could cause the detector head to drift and contact patients.

    Product
    Nuclear gamma cameras (ADAC Vertex Plus, ADAC Solus, ADAC Vertex V60 & ADAC Vertex Classic) Philips Medical System, Cleveland, OH 44143. Used to produce images depicting the anatomical distribution of single photon and positron emitting radioisotopes with the human body for…
    Category
    Medical Device
    Distribution
    0 states
  • HighFDA (Devices)·Z-1511-2014·2014-05-07

    GE Healthcare Recalls CardiacVX Software Due to Inaccurate Flow Values

    GE Healthcare is recalling CardiacVX and CardiacVX Flow software because it may report flow values higher than actual. The recall affects 101 units distributed worldwide.

    Product
    GE Healthcare, CardiacVX [CardiacVX (1.1.0 Ext. d) and CardiacVX Flow (1.1.0 Ext. d) analysis software running on Advantage Workstation]. Model #'s 5434389-2 and 5434384-2. The GE Cardiac VX for MRI is an analytical software tool, which provides reproducible tools for the…
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-1521-2014·2014-05-07

    Fisher Scientific Recalls Sterile Swabs Due to Organism Contamination

    Fisher Scientific is recalling Fisherbrand Sterile Swabs after a customer reported the presence of an organism in a lot of wood applicator swabs.

    Product
    Fisherbrand Sterile Swabs, Calcium Alginate Fiber Tipped Aluminum Applicator Swab, .025 and .035 in Diameter, all lots, 100 per pack Fisherbrand Sterile Swabs, Calcium Alginate Fiber Tipped Plastic Applicator Swab, all lots, 100 per pack Fisherbrand Sterile Swabs, Calcium…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1516-2014·2014-05-07

    Acumed Recalls Tension Band Pins Due to Steel Specification Defect

    Acumed LLC is recalling specific lots of Tension Band Pins because they were manufactured with stainless steel that does not meet specifications.

    Product
    The Acumed Tension Band Pin is a fixation pin which is .0625" in diameter and is available in lengths between 35mm and 90mm. It is to be used in conjunction with commonly used orthopedic wire. 50.0 mm Tension Band Pin; Part Number 30-0097 70.0 mm Tension Band Pin; Part…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1530-2014·2014-05-07

    Alfa Wassermann ACE AST Reagent Recalled for Low Absorbance Readings

    Alfa Wassermann is recalling specific lots of ACE AST Reagent because they produce extremely low absorbance readings, which may affect clinical test results.

    Product
    Alfa Wassermann Diagnostic Technologies, LLC. ACE AST Reagent. Product Usage: For quantitative determination of AST in serum and lithium heparin plasma using ACE¿, ACE Alera¿ and ACE Axcel Clinical Chemistry Systems. This test is intended for use in clinical laboratories…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1519-2014·2014-05-07

    Ortho-Clinical Diagnostics Recalls VITROS Specialty Diluent Due to Inaccurate CRP Results

    Ortho-Clinical Diagnostics is recalling VITROS Specialty Diluent because it may cause C-Reactive Protein test results to be approximately 51% lower than expected.

    Product
    VITROS Chemistry Products Specialty Diluent, REF 855 9825, 6 x 3 mL, IVD --- Ortho-Clinical Diagnostics, Inc. Rochester, NY
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1517-2014·2014-05-07

    Siemens IMMULITE Total IgE Assay Recalled for Positive Bias

    Siemens Healthcare Diagnostics is recalling IMMULITE Total IgE assays due to a confirmed 23% positive bias against the WHO 2nd IRP 75/502.

    Product
    IMMULITE /IMMULITE 1000 Systems TIE Total IgE, REF LKIE1, SMN 10380867, IVD --- Siemens Healthcare Diagnostics Products Ltd. For in vitro diagnostic use with the IMMULITE, IMMULITE 1000, and IMMULITE 2000/ IMMULITE 2000 XPi Systems Analyzers - for the quantitative measurement of…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1531-2014·2014-05-07

    Siemens IMMULITE Androstenedione Assay Recalled for Over-Recovery

    Siemens recalls IMMULITE Androstenedione assays because they over-recover samples above 5.5 ng/mL, contradicting the stated 10 ng/mL linearity limit.

    Product
    IMMULITE/IMMULITE 1000 Systems Androstenedione (Test Code AND), REF LKAO1, SMN 10381158, IVD, 100 test kit size --- Siemens Healthcare Diagnostics Products Ltd. Llanberis, Gwynedd, LL55 4EL, UK For in vitro diagnostic use with the IMMULITE/IMMULITE 1000 and 2000 Systems…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1529-2014·2014-05-07

    Alfa Wassermann ACE ALT Reagent Recalled for Low Absorbance Readings

    Alfa Wassermann is recalling 731 kits of ACE ALT Reagent due to extremely low absorbance readings that may affect test accuracy.

    Product
    Alfa Wassermann Diagnostic Technologies, LLC. ACE ALT Reagent. Product Usage: For quantitative determination of ALT in serum and lithium heparin plasma using ACE¿, ACE Alera¿ and ACE Axcel Clinical Chemistry Systems. This test is intended for use in clinical laboratories…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1532-2014·2014-05-07

    Siemens Androstenedione Assay Recall Due to Over-Recovery

    Siemens recalls Androstenedione assays because they over-recover samples above 5.5 ng/mL, contradicting the stated 10 ng/mL limit.

    Product
    IMMULITE 2000/2000 XPi Systems Androstenedione (Test Code AND), REF L2KAO2, SMN 10381188, IVD, 200 test kit size --- Siemens Healthcare Diagnostics Products Ltd. Llanberis, Gwynedd, LL55 4EL, UK For in vitro diagnostic use with the IMMULITE/IMMULITE 1000 and 2000 Systems…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1526-2014·2014-05-07

    Medtronic External Neurostimulators Recalled for Cycling Feature Labeling Issue

    Medtronic is recalling external neurostimulators because current labeling indicates the cycling feature improves device longevity and recharge interval.

    Product
    Medtronic, External neurostimulator, ENS (37021) & ENS (37022). Including the external neurostimulators which are associated with software application run on the NVision Clinician Programmer and used during trialing for spinal cord stimulation (SCS) patients.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1520-2014·2014-05-07

    Ortho-Clinical Diagnostics Recalls VITROS Chemistry Diluent Packs Due to Inaccurate Results

    Ortho-Clinical Diagnostics is recalling VITROS Chemistry Products FS Diluent Pack 3 because internal testing found it may cause C-Reactive Protein test results to be approximately 51% lower than expected when used for dilution.

    Product
    VITROS Chemistry Products FS Diluent Pack 3, REF 680 1754, 3 x 45 mL, (D1)/15 mL (D2), IVD --- Ortho-Clinical Diagnostics, Inc. Rochester, NY, 14626
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1535-2014·2014-05-07

    Teleflex Recalls Dekna-lok Sutures for Failing Resorption Strength Requirements

    Teleflex Medical is recalling 7,380 units of Dekna-lok sutures because they did not meet minimum resorption strength requirements. The affected products were distributed in the US, Ireland, and Singapore.

    Product
    Dekna-lok, 1 x 17.78 cm, Violet Braided Polyglycolic Acid Coated Suture, Synthetic Absorbable Surgical Suture USP, Rx Only, Sterile. Teleflex Product Code: 200101-01.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1536-2014·2014-05-07

    BD Biosciences Recalls Mislabeled Anti EpCAM PE Reagent Lots

    BD Biosciences is recalling two lots of Anti EpCAM PE reagent because the vials contain CD9 PE antibody instead of the labeled EpCAM antibody.

    Product
    Anti EpCam PE - Analyte Specific Reagent. Anti-EpCAM is directed against human epithelial adhesion molecule that has been identified as a 40 -kilodalton (kd) protein in Western Blotting.
    Category
    Medical Device
    Distribution
    7 states
  • ModerateFDA (Devices)·Z-1534-2014·2014-05-07

    Teleflex Recalls CAPIO Absorbable Surgical Sutures for Strength Defects

    Teleflex Medical is recalling CAPIO absorbable surgical sutures because they did not meet minimum resorption strength requirements. The recall affects 7,380 units distributed in the US, Ireland, and Singapore.

    Product
    CAPIO, Monodeck, Violet Monofilament Polydioxanone Suture, 1 x 48 inches (122cm) Absorbable Surgical Suture, Rx Only, Teleflex Medical. Product Code: 833-137.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1518-2014·2014-05-07

    Siemens Recalls IMMULITE 2000 Total IgE Assays Due to Positive Bias

    Siemens Healthcare Diagnostics is recalling specific lots of IMMULITE 2000 Total IgE assays because they show a 23% positive bias against the WHO standard.

    Product
    IMMULITE 2000 /IMMULITE 2000 XPi Systems TIE Total IgE, REF L2KIE2, SMN 10380873, and L2KIE6, SMN 10380872, IVD --- Siemens Healthcare Diagnostics Products Ltd. For in vitro diagnostic use with the IMMULITE, IMMULITE 1000, and IMMULITE 2000/ IMMULITE 2000 XPi Systems Analyzers…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-1527-2014·2014-05-07

    Laurimed Recalls PolypVac Microdebriders Due to Premature Mechanism Shutdown

    Laurimed LLC is recalling 58 PolypVac 3.5mm Microdebriders because the reciprocation mechanism may turn off prematurely due to a component failure in the handle.

    Product
    PolypVac 3.5mm Microdebrider; Catalog Number FG-000016; contents: 1 Microdebrider, 1 Stylet, 1 filter. Sterile. Used for the excision of polyps in the nasal passageways and in sinuses for which access has been previously established.
    Category
    Medical Device
    Distribution
    11 states