The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

34526–34550 of 40449

  • SevereFDA (Devices)·Z-0181-2015·2014-11-19

    Philips Allura Xper FD20C Radiological Imaging Systems Recalled for Motion Controller Fault

    Philips is recalling 22 Allura Xper FD20C radiological imaging systems due to a faulty Automatic Motion Controller that may cause hazardous movement of the C-arc.

    Product
    Philips Medical Systems Allura Xper FD20C Radiological Imaging with software version R8.2.O; System Code: 722028. The Allura Xper FD series are intended for use on human patients to perform: Vascular, cardiovascular and neurovascular imaging applications, including…
    Category
    Medical Device
    Distribution
    2 states
  • SevereFDA (Devices)·Z-0186-2015·2014-11-19

    GE Discovery NM/CT 670 Imaging System Recalled for Loose Fasteners

    GE Healthcare is recalling 255 Discovery NM/CT 670 systems because loose fasteners may cause a portion of the system to fall onto patients during scans.

    Product
    Discovery NM/CT 670 dual detector free-geometry integrated nuclear imaging system. Models H3100NA, H3100PP, H3100RA, H2401LS, H2401LZ, H2402LS. Product Usage: The GE Discovery NM/CT 670 system is a medical tool intended for use by appropriately trained healthcare…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0196-2015·2014-11-19

    Steris 5085 Surgical Tables Recalled for Damaged Column Shrouds

    Steris is recalling 5085 and 5085SRT surgical tables because column shrouds may become damaged, potentially preventing the table from raising or lowering.

    Product
    The 5085 is a general surgical table with high patient weight capacity, extended width capability, and lower minimal table top elevation.
    Category
    Medical Device
    Distribution
    36 states
  • HighFDA (Devices)·Z-0209-2015·2014-11-19

    American Medical Systems Recalls AMS 700 Series Inflatable Penile Prosthesis Accessory Kits

    American Medical Systems is recalling AMS 700 Series Accessory Kits because supplier-supplied Keith needles may bend or break when used with the Furlow tool.

    Product
    AMS 700 Series Inflatable Penile Prosthesis Accessory Kit (AMS 700 Line Accessory Kit), 72401850. Keith Needles are part of the AMS 700 Accessory Kit. In conjunction with the Furlow Insertion Tool (Furlow), the Keith Needles facilitate the passing of the pulling sutures…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0199-2015·2014-11-19

    DePuy ATTUNE Intuition Distal Femoral Jig Recall for Bushing Defect

    DePuy Orthopaedics is recalling ATTUNE Intuition Distal Femoral Jigs because a pin bushing defect could cause the plastic to fracture or displace during use.

    Product
    ATTUNE Intuition Distal Femoral Jig; sold non-sterile; product is wrapped in bubble wrap and then sealed inside a polyethylene bag
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0200-2015·2014-11-19

    Remel Legionella Growth Supplement Recalled for Potential False Negative Results

    Remel Inc is recalling Legionella BCYE Growth Supplement because it may fail to recover Legionella pneumophila, leading to false negative identification.

    Product
    Oxoid Legionella BCYE Growth Supplement SR0110A, packaged in 100 ml vials, 10/pkg. A growth supplement for the isolation of Legionella.
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0183-2015·2014-11-19

    Siemens Artis zeego C-arm systems recalled for cable routing defect

    Siemens is recalling 164 Artis zeego systems because a cable may be routed incorrectly, potentially causing system failure during procedures.

    Product
    Artis zeego systems, model number 10280959, with serial numbers 1000-1599 : Artis zeego is a dedicated angiography system developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients. Procedures…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0213-2015·2014-11-19

    Masimo SET uSpO2 Pulse Oximetry Cables Recalled for Crossed Wires

    Masimo Corporation is recalling specific SET uSpO2 Pulse Oximetry Cables due to crossed internal wires that may cause the monitoring device to display inverted SpO2 values.

    Product
    Masimo SET uSpO2 Cable The Masimo SET uSpO2 Pulse Oximetry Cable is an in-line cable that provides continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (Sp02) and pulse rate when installed in a compatible OEM host system. Shipping/Package…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0185-2015·2014-11-19

    GE Healthcare Recalls Varicam and VG Hawkeye Nuclear Medicine Devices

    GE Healthcare is recalling 478 nuclear medicine imaging devices because loose fasteners could cause a portion of the system to fall onto a patient during a scan.

    Product
    GE Healthcare Varicam/VG and VG Hawkeye devices. Models H3000YA, H3000YB, H3000YC, H3000YD, H2508PA, H2508PB, H2508PC, H2508PD. Product Usage: The intended use of the Quasar system is to perform general Nuclear Medicine imaging procedures for detection of radioisotope…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0197-2015·2014-11-19

    Integra Titan Reverse Shoulder System Cutting Templates Recalled for Manufacturing Error

    Integra LifeSciences Corp. is recalling 12 units of Reverse Shoulder System cutting templates because the threaded handle was welded backwards, resulting in an incorrect cutting angle.

    Product
    Integra Titan Reverse Shoulder System right and left head cutting templates, 142.5 degrees. The Reverse Shoulder System Cutting Template, 142.5 degrees is an accessory for use with the Integra Titan Reverse Shoulder System. It is used to project the osteotomy angle on the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0189-2015·2014-11-19

    GE Healthcare Recalls Brivo NM615 Nuclear Imaging Systems Due to Loose Fasteners

    GE Healthcare is recalling 22 Brivo NM615 nuclear imaging systems because loose fasteners could cause a portion of the system to fall onto a patient during a scan.

    Product
    Brivo NM615, is an all-purpose, single detector integrated nuclear imaging system. Models H3100TP, H3100TN, H3100TT, H3100TR, H3100TW, H3100WZ, H2401MP, H2401MN, H2401MT, H2401MR, H2401MW, H2401NJ. Product Usage: The Brivo NM 615 is an emission computed tomography system…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0187-2015·2014-11-19

    GE Healthcare Recalls Discovery NM 630 Nuclear Imaging Systems

    GE Healthcare is recalling 147 Discovery NM 630 nuclear imaging systems to update maintenance procedures and prevent loose fasteners from causing parts to fall on patients.

    Product
    Discovery NM 630, dual detector free-geometry integrated nuclear imaging system. Models H3100RC, H3100RD, H2401LW. Product Usage: The GE Discovery NM 630 system is a medical tool intended for use by appropriately trained healthcare professionals to aid in detecting…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0204-2015·2014-11-19

    Roscoe Medical Recalls Transport Rollators Due to Caster Separation Risk

    Roscoe Medical Inc is recalling 831 Transport Rollators because the caster may separate from the frame, posing an injury risk to users.

    Product
    Transport Rollator with Padded Seat; Large 8-inch wheels with wheel locks (indoor and outdoor use), fold down footrests, ergonomic handles, curved padded backrest and handy wire basket for storage. Item# 30192 Burgundy each/Item# 30194 Blue each.. Transport Rollator is a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0191-2015·2014-11-19

    Bard PerFix Light Plug Recalled for Labeling Mismatch

    Davol, Inc. is recalling 78 units of Bard PerFix Light Plug because the patient record label did not match the actual product in the packaging.

    Product
    Bard¿ PerFix Light Plug The Bard¿ PerFix Light Plug is indicated for reinforcement if soft tissue, where weakness exists, in procedures involving soft tissue repair, such as groin hernia defects.
    Category
    Medical Device
    Distribution
    8 states
  • ModerateFDA (Devices)·Z-0211-2015·2014-11-19

    Maquet Cardiohelp-I System Recalled for Potential Software Display Error

    Maquet Cardiovascular is recalling 331 Cardiohelp-I Systems due to a software issue that may display an erroneous 'Battery Needs Service' message after startup.

    Product
    Cardiohelp-I System Product Usage: A blood oxygenation and carbon dioxide removal system used to pump blood thorough the extracorporeal bypass circuit for circulatory and/or pulmonary support during procedures requiring cardiopulmonary bypass (for periods up to six hours).…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0193-2015·2014-11-19

    GE OEC MiniView 6800 C-Arm Recall for Component Revision

    GE Healthcare is recalling 26 OEC MiniView 6800 C-Arms because prior component revisions may have been incorrectly installed.

    Product
    OEC¿ MiniView 6800. The Mini 6800 Digital Mobile C-Arm is designed to provide the physician with general fluoroscopic visualization of the patient including but not limited to surgical orthopedic and extremity imaging. The device is not intended for whole-body pediatric…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0205-2015·2014-11-19

    Medtronic Launcher Coronary Guide Catheter Recalled for Incorrect Length

    Medtronic Vascular is recalling 11 Launcher Coronary Guide Catheters because they have a usable length of 90 cm instead of the labeled 55 cm.

    Product
    Medtronic Launcher Coronary Guide Catheter; MODEL: LA6JR40K
    Category
    Medical Device
    Distribution
    4 states
  • ModerateFDA (Devices)·Z-0201-2015·2014-11-19

    Integra Licox Pt02 Monitor Recalled for USB Data Extraction Issues

    Integra LifeSciences is recalling 60 Licox Pt02 monitors because the USB port may not allow users to extract trend data as described in the manual.

    Product
    Integra Licox Pt02 Monitor, Rx Only, Manufacturer: Integra LifeSciences (Ireland) Limited, IDA Business and Technology Park, Sragh, Tullamore, County Offaly, Ireland, Distributed by: Integra LifeSciences Corporation, 311 Enterprise Drive, Plainsboro, NJ 08536
    Category
    Medical Device
    Distribution
    11 states
  • ModerateFDA (Devices)·Z-0192-2015·2014-11-19

    GE OEC UroView 2800 Imaging Systems Field Correction for Component Revision

    GE Healthcare is correcting OEC UroView 2800 systems because prior component revisions may have been incorrectly installed.

    Product
    OEC¿ UroView 2800. The UroView 2800 is designed to provide fluoroscopic and spot-film imaging of the patient during diagnostic, surgical. and interventional procedures
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0190-2015·2014-11-19

    Philips MX 16-slice CT Scanner Recalled for Incorrect Image Orientation

    Philips Medical Systems is recalling 708 MX 16-slice CT Scanner Systems because scan images may display left and right sides reversed, potentially leading to misinterpretation of patient position.

    Product
    MX 16-slice CT Scanner System and MX 16-slice CT Scanner System Phase 11 can be used as a whole body computed tomography X-ray system featuring a continuously rotating X-ray tube and detector array with multi-slice capability up to 16 slices simultaneously. The acquired X-RAY…
    Category
    Medical Device
    Distribution
    20 states
  • ModerateFDA (Devices)·Z-0198-2015·2014-11-19

    Zimmer Persona Stemmed 5 Degree Cemented Tibia Recalled for Cleaning Failure

    Zimmer, Inc. is recalling 138 units of Persona Stemmed 5 Degree Cemented Tibia knee components due to a cleaning process validation failure.

    Product
    Persona Stemmed 5 Degree Cemented Tibia Product Usage: This device is indicated for patients with severe knee pain and disability due to:  Rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis.  Collagen disorders, and/or avascular necrosis of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0194-2015·2014-11-19

    GE Healthcare Recalls FlexiView 8800 Digital Mobile Imaging Systems

    GE Healthcare is recalling five FlexiView 8800 systems because prior component revisions were potentially installed on these units.

    Product
    FlexiView 8800 Digital Mobile Imaging System. The FlexiView 8800 Digital Mobile Imaging System is designed to provide fluoroscopic and spot film, imaging of the patient during diagnostic, surgical and interventional procedures.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0195-2015·2014-11-19

    GE OEC 9800 Medical Imaging Systems Field Correction for Component Revision

    GE Healthcare is correcting 311 OEC 9800 imaging systems worldwide because prior component revisions may have been incorrectly installed.

    Product
    Series OEC 9800. The Series OEC 9800 is designed to provide fluoroscopic and spot-film imaging of the patient,during diagnostic, surgical and interventional procedures.
    Category
    Medical Device
    Distribution
    0 states
  • LowFDA (Devices)·Z-0207-2015·2014-11-19

    CooperSurgical MILEX Pessary Kits Recalled for Incorrect Expiration Date

    CooperSurgical is recalling 17 MILEX Pessary Kits because the packaging displays an incorrect expiration date.

    Product
    CooperSurgical MILEX PESSARY KITS-Ring w/Support Folding Pessary- #1 Model: MXKPRS01 Product Usage: The CooperSurgical Milex silicon pessary is a safe and effective device used to manage a number of gynecologic issues including pelvic support defects and stress urinary…
    Category
    Medical Device
    Distribution
    13 states
  • LowFDA (Devices)·Z-0212-2015·2014-11-19

    Siemens IMMULITE Calcitonin Control Module Recalled for Typographical Error

    Siemens Healthcare Diagnostics is recalling the IMMULITE Calcitonin Control Module due to a typographical error in the expiration date on the instructions for use.

    Product
    IMMULITE Calcitonin Control Module (IMMULITE, IMMULITE 1000, IMMULITE 2000, IMMULITE 2000 XPi) For in vitro diagnostic use with IMMULITE¿ Systems Analyzers  for the quantitative measurement of calcitonin (thyrocalcitonin) in human serum or heparinized plasma, as an aid in…
    Category
    Medical Device
    Distribution
    9 states