The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

33726–33750 of 40449

  • HighFDA (Devices)·Z-0959-2015·2015-01-21

    Sun Nuclear IC Profiler-MR Recalled for Pinch Hazard

    Sun Nuclear Corporation is recalling six IC Profiler-MR Model 1123 units due to a potential pinch hazard to users performing quality assurance in MRI environments.

    Product
    IC PROFILER-MR - Model 1123. A radiologic quality assurance instrument is a device intended for medical purposes to measure a physical characteristic associated with another radiologic device.
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0971-2015·2015-01-21

    Siemens SOMATOM Force CT Scanner Recalled for Imaging Artifacts

    Siemens Medical Solutions is recalling seven SOMATOM Force CT scanners because artifacts were found in acquired imaging.

    Product
    SOMATOM Force; the intended use of computed tomography is to produce cross-sectional images of the body by computer reconstruction of x-ray transmission data from either the same axial plane taken at different angels or spiral planes taken at different angles.
    Category
    Medical Device
    Distribution
    6 states
  • HighFDA (Devices)·Z-0957-2015·2015-01-21

    Brainlab iPlan RT Software Recalled for Potential Incorrect Patient Positioning

    Brainlab AG is recalling iPlan RT radiation treatment planning software due to a risk of incorrect patient positioning when using multiple localized CT image data sets.

    Product
    iPlan RT is a radiation treatment planning system that is intended for use in stereotactic, conformal, computer planned, Linac based radiation treatment of cranial, head and neck, and extracranial lesions.
    Category
    Medical Device
    Distribution
    45 states
  • HighFDA (Devices)·Z-0974-2015·2015-01-21

    Becton Dickinson Recalls Trypticase Soy Agar and MacConkey II Agar Plates

    Becton Dickinson is recalling specific lots of Trypticase Soy Agar and MacConkey II Agar plates due to low-level Listeria monocytogenes contamination.

    Product
    TrypticaseTM Soy Agar with 5% Sheep Blood (TSA IITM) // MacConkey II Agar Trypticase Soy Agar with 5% Sheep Blood is used for the growth of fastidious organisms and for the visualization of hemolytic reactions. MacConkey II Agar is a selective and differential medium for the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0972-2015·2015-01-21

    Siemens Artis Q Ceiling Systems Recalled for Cable Wear Risk

    Siemens is recalling 50 Artis Q and Artis Q.zen ceiling systems because suboptimal cable routing may cause wear, leading to limited functionality or system failure.

    Product
    Artis Q, and Artis Q.zen ceiling systems; model numbers: 10848281; 10848354: The Artis family is dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients.…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0950-2015·2015-01-21

    FDA Recalls Unapproved Color Contact Lenses Contaminated with Bacteria

    Intertrade Imports Inc. is recalling I Color Complete color contact lenses because FDA testing found Bacillus Cereus and Bacillus Lentus. The lenses are also unapproved medical devices.

    Product
    Labeled in part: I Color Complete / Color Lens, blister packing, 14.5mm. (Additional colors include: 1) Illusion style, Chestnut Brown, Violet and others and 2) 2 Tone style: like Misty Blue among others)Eye contact lens Product Usage - Eye contact lens
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-0977-2015·2015-01-21

    SpineFrontier Recalls Inline Persuader Pedicle Screw System Due to Handle Crack

    SpineFrontier, Inc. is recalling four Inline Persuader PedFuse Pedicle Screw Systems because a crack may develop in the handle, potentially progressing with continued use.

    Product
    lnline Persuader- PedFuse Pedicle Screw System; Part Number: 11-80164
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0949-2015·2015-01-21

    St. Jude Medical Merlin@home Transmitter Software Reset Recall

    St. Jude Medical is recalling Merlin@home RF Remote Monitoring Transmitters because a software reset may cause backup operation in implanted cardiac devices.

    Product
    Merlin@home RF Remote Monitoring Transmitter, Model EX1150, with software versions 6.1M or 7.0. Usage:RF Remote Transmitter
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0973-2015·2015-01-21

    Synthes Malleable C-Retractor Recalled Due to Potential Spring Corrosion

    Synthes, Inc. is recalling Malleable C-Retractors because the internal spring may corrode or fail, potentially transferring particles to patients and causing adverse tissue reactions or infection.

    Product
    Malleable C- Retractor, Part Number 397.232, used to provide retraction of the soft tissues during use of trocar instrumentation. Used in the following systems: the Basic Trocar System, Universal Trocar System, Craniofacial Modular Fixation System, Craniofacial (CMF)…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0958-2015·2015-01-21

    Invivo Recalls Philips Expression MR200 MRI Patient Monitoring Systems

    Invivo Corporation is recalling 20 Philips Expression MR200 MRI Patient Monitoring Systems due to capacitor shorts that may cause electrical shock or loss of monitoring.

    Product
    Philips Expression MR200 MRI Patient Monitoring System.
    Category
    Medical Device
    Distribution
    11 states
  • HighFDA (Devices)·Z-0987-2015·2015-01-21

    Siemens ADVIA Chemistry XPT Software Recall for Result Overwrite Risk

    Siemens is recalling 7 ADVIA Chemistry XPT systems in Washington due to a software defect that may cause critical results to be overwritten.

    Product
    ADVIA Chemistry XPT interfaced to the CentraLink Data Management System V14x in specific configurations: The CentraLink system software is a network solution provider and multi-system data manager for the instruments and lab automation systems (LAS) within the lab. The…
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-0979-2015·2015-01-21

    Philips CT Systems Recalled for Improper Vertical Motor Assembly

    Philips is recalling Brilliance and Ingenuity CT systems because improper assembly of the vertical motor/brake system may lead to uncommanded vertical motion.

    Product
    Various Brilliance and Ingenuity Computed Tomography X-ray systems; one unit per package Product Usage: Intended to produce cross-sectional images of the body by computer reconstruction of X-ray transmission data taken at different angles and planes. This device may include…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0966-2015·2015-01-21

    GE Healthcare Recalls Discovery IGS 730 and 740 X-ray Systems

    GE Healthcare is recalling 24 Discovery IGS 730 and 740 angiographic X-ray systems due to a user interface issue that may cause unintentional system motion or rotation.

    Product
    GE Healthcare, Discovery IGS 730 & Discovery IGS 740. Discovery IGS 730 : The angiographic X-ray systems are indicated for use in generating fluoroscopic and rotational images of human anatomy for cardiovascular, vascular & non vascular diagnostic and interventional…
    Category
    Medical Device
    Distribution
    7 states
  • HighFDA (Devices)·Z-0952-2015·2015-01-21

    Medtronic Spinal Surgical Instrument Recall Due to Component Sizing Issue

    Medtronic is recalling 24 units of the POWEREASE Set Screw Breakoff Instrument because oversized retaining tabs may prevent proper mating with the set screw.

    Product
    POWEREASE Instruments Set Screw Breakoff Instrument, REF 2346010, Medtronic Sofamor Danek, USA, Inc. Spinal surgical instrumrent.
    Category
    Medical Device
    Distribution
    16 states
  • HighFDA (Devices)·Z-0976-2015·2015-01-21

    Becton Dickinson Recalls Columbia Agar with 5% Sheep Blood Due to Listeria

    Becton Dickinson & Co. is recalling Columbia Agar with 5% Sheep Blood due to low-level Listeria monocytogenes contamination. The product is a non-sterile culture medium distributed worldwide.

    Product
    Columbia Agar with 5% Sheep Blood Columbia Agar with 5% Sheep Blood is a general purpose culture medium used for the growth and recovery of fastidious microbial species.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0975-2015·2015-01-21

    Becton Dickinson Recalls CDC Anaerobe Agar Due to Listeria Contamination

    Becton Dickinson is recalling CDC Anaerobe 5% Sheep Blood Agar due to low-level Listeria monocytogenes contamination. The affected non-sterile media were distributed worldwide.

    Product
    CDC Anaerobe 5% Sheep Blood Agar CDC Anaerobe 5% Sheep Blood Agar is an enriched, nonselective culture medium particularly useful or the isolation and cultivation of obligate anaerobes from clinical specimens. It supports the growth of a wide variety of obligately anaerobic…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0960-2015·2015-01-21

    Siemens Symbia CT Systems Recalled for Internal Component Damage

    Siemens Medical Solutions is recalling 295 Symbia T and T2 CT systems because a component may come loose and damage the equipment.

    Product
    Symbia T and Symbia T2 computer tomography systems. These systems are used to perform SPECT, CT, and SPECT + CT scans and imaging studies.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0978-2015·2015-01-21

    Biomet Timberline Anchored Lateral Variable Retractable Sleeves Recalled for Undersized Diameter

    Biomet Spine is recalling 12 units of Timberline Anchored Lateral Variable Retractable Sleeves because the inner diameter is undersized, causing interference fit issues.

    Product
    Timberline Anchored Lateral Variable Retractable Sleeve LITPCR8600-2101-07, Model No. 86300204 Timberline Anchored Lateral Variable Retractable Sleeves (the Sleeves) are used with the Timberline MPF System to help establish access into the vertebrae for the screws utilized…
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-0947-2015·2015-01-21

    Phadia 1000 Instrument Recalled for Rack Sequencing Error

    Phadia US Inc is recalling 146 Phadia 1000 instruments due to a software error that may cause sample ID and test result mismatches.

    Product
    Phadia 1000 Instrument (introduced as UniCAP 1000), Article number: 12-3800-01 (All instrument software versions since launch in 2003); Multiple ImmunoCAP assays for Allergen Testing, FDA Cleared for use on Phadia 1000 instrument with IU statement-see attachments. Software…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0981-2015·2015-01-21

    Straumann Dental Implant Drill Set Recalled for Incorrect Drill

    Straumann USA is recalling dental implant drill sets that may contain incorrect drills. The recall covers 362 pieces distributed nationwide and internationally.

    Product
    Drill set long, drill stop compatible for 4.8mm diameter implant, Article Number 040.447S Endosseous dental implant drill set.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0985-2015·2015-01-21

    GE Healthcare Recalls Revolution CT Scanners for Bolted Joint Torque Check

    GE Healthcare is recalling 13 Revolution CT scanners to perform a required torque check on three bolted joints. No injuries or illnesses have been reported.

    Product
    GE Healthcare Revolution CT., multi-slice (256 detector row) CT scanner.
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-0982-2015·2015-01-21

    Biomet Spine Recalls Anchored Lateral Retractable Drills Due to Sizing Defect

    Biomet Spine is recalling 15 Anchored Lateral Retractable Drills because the shaft diameter is oversized, causing interference when inserted into sleeve assemblies.

    Product
    Anchored Lateral Retractable Drill, Timberline IPF IFU IFU8621-0113, Model 8630-0102. Timberline Anchored Lateral Retractable Drills are used with the Timberline MPF System to establish access into the vertebrae for the screws utilized to anchor the plate to the vertebrae.
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-0965-2015·2015-01-21

    Biocare Medical Recalls MUM-1 Antibody Lots Due to Staining Intensity Issues

    Biocare Medical is recalling three lots of MUM-1 antibody because staining intensity drops over time, potentially affecting diagnostic accuracy.

    Product
    MUM-1 (Multiple myeloma oncogene-1), catalog number PRM352 AA; Product Usage: For In Vitro Diagnostic Use. This antibody may be used as a tool for the identification and the sub classification of lymphoid malignancies : Multiple myeloma oncogene-1 (MUM-1) is a protein…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0983-2015·2015-01-21

    Biomet Spine Recalls Timberline Anchored Lateral Fixed Retractable Sleeves

    Biomet Spine is recalling 14 Timberline Anchored Lateral Fixed Retractable Sleeves because the inner diameter is undersized, causing interference fit when inserting instruments.

    Product
    Timberline Anchored Lateral Fixed Retractable Sleeve Model No. 8630-0205. Timberline Anchored Lateral Fixed Retractable Sleeves are used with the Timberline MPF System to help establish access into the vertebrae for the screws utilized to anchor the plate to the vertebrae. The…
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-0969-2015·2015-01-21

    Ortho VITROS 5600 System Recalled for Software Calibration Error

    Ortho-Clinical Diagnostics is recalling VITROS 5600 Integrated Systems because software may fail to identify expired calibrations.

    Product
    VITROS 5600 Integrated System, Catalog Number 6802413, IVD --- Ortho Clinical Diagnostics. For use in the in vitro quantitative, semi-quantitative, and qualitative measurement of a variety of analytes of clinical interest, using VITROS Chemistry Products Slides, VITROS…
    Category
    Medical Device
    Distribution
    Distributed nationwide