The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3351–3375 of 5038

  • SevereFDA (Devices)·Z-1901-2018·2018-05-30

    LivaNova Recalls Sorin Stockert Heater-Cooler Systems Due to Suspected Microbial Contamination

    LivaNova USA is recalling 2,408 Sorin Stockert Heater-Cooler System 3T units because they are suspected of microbial contamination and may contain visible biofilm.

    Product
    Sorin Stockert Heater-Cooler System 3T, a) Item #: 16-02-81, 240 v/60 Hz; b) Item #: 16-02-82, 208 v/60 Hz; c) Item #: 16-02-85, 120 v/60 Hz
    Category
    Medical Device
    Distribution
    44 states
  • CriticalFDA (Devices)·Z-1774-2018·2018-05-23

    Abbott HeartMate 3 LVAS Implant Kit Recalled for Graft Occlusion Risk

    Abbott is recalling HeartMate 3 LVAS Implant Kits due to reports of outflow graft twist occlusions that can cause serious adverse events.

    Product
    Thoratec HeartMate 3 LVAS Implant Kit, Rx Only, Catalog # 106524US, 106524, 10652INT - LVAS KIT, HM 3 Indicated for providing short-term hemodynamic support in patients with advanced refractory left ventricular heart failure.
    Category
    Medical Device
    Distribution
    35 states
  • SevereFDA (Devices)·Z-1821-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Reloads Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA 30mm stapler reloads because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    Endo GIA" 30mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA30CTAV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1815-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Loading Units Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 30mm - 2.5mm ( Item Code 030451) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1817-2018·2018-05-23

    Medtronic Endo GIA Stapler Loading Units Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Auto Suture Universal Articulating Loading Units because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 45mm - 2.5mm( Item Code 030454) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1862-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX TGGLOGOWX1 DO TOTAL GASTRECTOMIII Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is deter
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1816-2018·2018-05-23

    COVIDIEN Recalls Endo GIA Stapler Loading Units Due to Missing Sled Component

    COVIDIEN MEDTRONIC is recalling 171,271 Endo GIA Universal Articulating Loading Units because a missing sled component may prevent proper staple deployment, risking bleeding or leakage during surgery.

    Product
    Endo GIA" Auto Suture" Universal Articulating Loading Unit 30mm - 3.5mm ( Item Code 030452) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two,
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1837-2018·2018-05-23

    Medtronic Endo GIA Universal Bypass Kits Recalled for Missing Sled Component

    Medtronic is recalling specific Endo GIA Universal Bypass Kits because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    KIT-DE-0080 BYPASS KIT LOHNE X1( Item KIT-DE-0080) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the sta
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1824-2018·2018-05-23

    Medtronic Recalls Endo GIA Stapler Kits Due to Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA stapler kits worldwide because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    Covidien" Best Practices" Procedure Kits containing Auto Suture" Endo GIA" Devices Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-s
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1825-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA Universal staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    BOX KIT1095V KIT OBESITAS (Item Code KIT1095V) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples i
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1865-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX VMIN ZESTAW DO VATS PODSTAWOWY Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determin
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1863-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX VATS1SCDX DO ZABIEGOW VATS Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined b
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1822-2018·2018-05-23

    Medtronic Endo GIA Stapler Reloads Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA 30mm stapler reloads because a missing sled component may cause staple failure, leading to bleeding or leakage.

    Product
    Endo GIA" 30mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA30AV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue b
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1843-2018·2018-05-23

    Medtronic Recalls Bariatric Surgical Kits Due to Missing Staple Sled Component

    Medtronic is recalling 169,775 bariatric surgical kits worldwide because a missing sled component may prevent staple formation, risking bleeding or leakage.

    Product
    (1)LAPBARLECZNA ZESTAW BARIATRYCZNY LECZNA (2) KITBAR021- BARIATRIC KIT X1 Item Code:KITBAR021- BARIATRIC KIT X0 (3)BOX SGGLOGX1 ZESTAW DO BARIATRII Item Code: SGGLOGX1 ZESTAW DO BARIATRII (4)BOX SGGLOGX1 ZESTAW DO BARIATRII Item Coder:SGGLOGX1 ZESTAW DO BARI
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1826-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA Universal and Universal XL staplers worldwide due to a missing sled component that may cause staple line failure, bleeding, or leakage.

    Product
    (1) BOX 01KBAR006116V PROC BYPASS 01KBAR0061(Item Code 01KBAR006116V PROC BYPAS) (2) BOX 1073076GASB0 BBR STVEIT GASTRIC B (Item Code BOX1073076GASB0) (3) BOX BOX1073076GASB0 BBR STVEIT GASTRIC B (Item Code BOX1073076GASB0 BBR STVEIT GASTRIC B) Product Usage:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1849-2018·2018-05-23

    Medtronic Recalls Bariatric Staplers Due to Missing Sled Component

    Medtronic is recalling specific bariatric stapler kits because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    (1)BOX PST01199 BARIATRIC TRISTAPLE (Item Number: PST01199) (2) BOX PST03403 ALTERNATIVE APPENDIX KIT (Item Number: PST03403) (3) BOX PST03533 KIT APP STAPLER (Item Number: PST03403) Product Usage: The Endo GIA universal and End
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1842-2018·2018-05-23

    Medtronic Endo GIA Stapler Kits Recalled for Missing Sled Component

    Medtronic is recalling 171,271 Endo GIA stapler kits worldwide because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    (1)BOX KITDE0183 APPENDIX LIPPE DETMOLD (KITDE0183) (2) KIT-DE-0083 APPENEKTOMIE KIT NAUENX1 (Item Number: KIT-DE-0083,KIT-DE-0083 APPENEKTOMIE KIT NAUENX1 Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titan
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1850-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling 169,775 Endo GIA universal staplers worldwide and in the US because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    MGBX ZESTAW GB LS X1 Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by the sele
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1859-2018·2018-05-23

    Medtronic Endo GIA Stapler Sleeves Recalled for Missing Sled Component

    Medtronic is recalling 169,775 Endo GIA stapler sleeves worldwide due to a missing sled component that may prevent staple formation, risking bleeding or leakage.

    Product
    (1)BOX SLEEVEGK3 (2) BOX SLEEVEGK4 SLEEVE GASTRECTOMY (3)BOX SLEEVEJAWI SLEEVE GASTRECTOMY BOX (4) SSLEEVE ZEST DO SLEEVE GASTREKTOMIIX1 Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of t
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1823-2018·2018-05-23

    Medtronic Endo GIA Vascular Reloads Recalled for Missing Sled Component

    Medtronic is recalling specific Endo GIA vascular reloads because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    Endo GIA" 45mm Gray Curved Tip Articulating Vascular Reload with Tri-Staple" Technology( Item Code EGIA45CTAV) Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1834-2018·2018-05-23

    Medtronic Endo GIA Universal Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA Universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX KIT1171C KIT LAP CYSTECTOMY Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1852-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA staplers because a missing sled component may prevent staple formation, leading to bleeding or leakage.

    Product
    BOX PST03533 KIT APP STAPLER Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is determined by
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1830-2018·2018-05-23

    COVIDIEN Medtronic Recalls Endo GIA Staplers for Missing Sled Component

    COVIDIEN Medtronic is recalling approximately 171,271 Endo GIA universal staplers because a missing sled component may prevent proper staple deployment. This defect can lead to bleeding or leakage of luminal contents during surgery.

    Product
    (1)BOX HEMIGX1 ZESTAW DO HEMICOLECTOMII (Item Number HEMIGX1 ZESTAW DO HEMICOLECTOMII) (2) BOX LAPPH ZASTAW DO PRAWEJ HEMIKOLEKTOMI (item number: LAPPH ZASTAW DO PRAWEJ HEMIKOLEKTOMI Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place t
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1848-2018·2018-05-23

    Medtronic Endo GIA Staplers Recalled for Missing Sled Component

    Medtronic is recalling Endo GIA universal staplers because a missing sled component may prevent staple formation, potentially causing bleeding or leakage.

    Product
    BOX MGBGLOGX1 ZESTAW MINI GASTRIC BYPASS Product Usage: The Endo GIA universal and Endo GIA universal XL staplers place two, triple-staggered rows of titanium staples and simultaneously divides the tissue between the two, triple-staggered rows. The size of the staples is de
    Category
    Medical Device
    Distribution
    Distributed nationwide