The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

3251–3275 of 5038

  • SevereFDA (Devices)·Z-2408-2018·2018-07-18

    Stryker Recalls Ankle Arthrodesis Nails Due to Potential Breakage Risk

    Stryker GmbH is recalling specific ankle arthrodesis nails because non-conforming cannulation may reduce strength and cause premature breakage.

    Product
    Ankle Arthrodesis Nail, right T2 Ankle ¿11x300mm, Product Number 18191130S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2401-2018·2018-07-18

    Stryker Recalls Specific Femoral Nail Products Due to Potential Breakage

    Stryker GmbH is recalling specific femoral nails due to potential manufacturing defects that could cause the device to break prematurely.

    Product
    Femoral Nail, A/R, R1500 T2 Femur ¿12x380 mm, Product Number 18281238S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2420-2018·2018-07-18

    Medtronic EnTrust Escudo ICD Recall for Potential Loss of Therapy

    Medtronic is recalling EnTrust Escudo ICDs due to a potential loss of high voltage and anti-tachycardia pacing therapy as the battery nears its end of life.

    Product
    Medtronic EnTrust Escudo D144VRC (OUS distribution) Product Usage: The implantable cardioverter defibrillator is intended to provide ventricular antitachycardia pacing and ventricular defibrillation for automated treatment of life-threatening ventricular arrhythmias.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2393-2018·2018-07-18

    Stryker Tibial Nail Recall Due to Potential Premature Breakage

    Stryker GmbH is recalling specific Tibial Nails because non-conforming cannulation may reduce strength and cause premature breakage.

    Product
    Tibial Nail, Standard T2 Tibia ¿12x315 mm, Product Number 18221231S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2417-2018·2018-07-18

    Medtronic EnTrust ICD Recall for Potential Loss of High Voltage Therapy

    Medtronic is recalling 8,890 EnTrust ICDs due to a potential loss of high voltage therapy near end-of-life. Patients should contact their healthcare provider.

    Product
    Medtronic EnTrust Dual Chamber Implantable Cardioverter Defibrillator with Atrial and Ventricular Therapies and RapidRead Telemetry, D154ATG Product Usage: The device indicated for use in ICD patients with atrial tachyarrhythmias, or who are at significant risk of developing
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2397-2018·2018-07-18

    Stryker Recalls Specific Femoral Nail Due to Potential Breakage Risk

    Stryker GmbH is recalling specific femoral nails due to potential manufacturing defects that could cause the device to break prematurely.

    Product
    Femoral Nail, A/R T2 Femur ¿15x240 mm, Product Number 18251524S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2407-2018·2018-07-18

    Stryker Recalls Ankle Arthrodesis Nails Due to Potential Breakage Risk

    Stryker GmbH is recalling specific ankle arthrodesis nails because non-conforming cannulation may reduce strength and cause premature breakage.

    Product
    Ankle Arthrodesis Nail, right T2 Ankle ¿10x300mm, Product Number 18191030S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2398-2018·2018-07-18

    Stryker Recalls Seven Femoral Nails Due to Potential Breakage Risk

    Stryker GmbH is recalling seven femoral nails because non-conforming cannulation may reduce strength and cause premature breakage.

    Product
    Femoral Nail, A/R, R1500 T2 Femur ¿10x320 mm, Product Number 18281032S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2405-2018·2018-07-18

    Stryker Recalls Femoral Nails Due to Potential Premature Breakage

    Stryker GmbH is recalling specific femoral nails because non-conforming cannulation may reduce component strength and lead to premature breakage.

    Product
    Femoral Nail, RIGHT T2 GTN ¿9x320 mm, Product Number 18510932S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2404-2018·2018-07-18

    Stryker Recalls Femoral Nails Due to Potential Premature Breakage

    Stryker GmbH is recalling specific femoral nails because non-conforming cannulation may reduce strength and cause premature breakage.

    Product
    Femoral Nail, LEFT T2 GTN ¿14x300 mm, Product Number 18501430S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2403-2018·2018-07-18

    Stryker Recalls Femoral Nails Due to Potential Premature Breakage

    Stryker GmbH is recalling specific femoral nails because non-conforming cannulation may reduce strength and cause premature breakage.

    Product
    Femoral Nail, LEFT T2 GTN ¿12x360 mm, Product Number 18501236S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2418-2018·2018-07-18

    Medtronic EnTrust ICD Recall for Potential Loss of High Voltage Therapy

    Medtronic is recalling 3 EnTrust ICDs because they may lose high voltage therapy near battery end-of-life without prior warning.

    Product
    Medtronic EnTrust SingleChamber Implantable Cardioverter Defibrillator with Atrial and Ventricular Therapies and RapidRead Telemetry, D153VRC Product Usage: The implantable cardioverter defibrillator is intended to provide ventricular antitachycardia pacing and ventricular def
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2380-2018·2018-07-18

    Intuitive Surgical Recalls da Vinci Xi Stapler Reloads Due to Missing Component

    Intuitive Surgical is recalling da Vinci Xi Stapler 45 Reloads because a missing knife mechanism component may prevent the device from cutting tissue.

    Product
    da Vinci Xi EndoWrist Stapler 45 Reload Blue, Model 48645B-03, 12 reloads/box.
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-2406-2018·2018-07-18

    Stryker Recalls Femoral Nails Due to Potential Premature Breakage

    Stryker GmbH is recalling specific femoral nails because non-conforming cannulation may reduce strength and cause premature breakage.

    Product
    Femoral Nail, RIGHT T2 GTN ¿14x460 mm, Product Number 18511446S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2395-2018·2018-07-18

    Stryker Recalls 17 Femoral Nails Due to Potential Premature Breakage

    Stryker GmbH is recalling 17 femoral nails because non-conforming cannulation may reduce component strength and cause premature breakage.

    Product
    Femoral Nail, A/R T2 Femur ¿10x340 mm, Product Number 18251034S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2399-2018·2018-07-18

    Stryker Recalls Femoral Nails Due to Potential Premature Breakage

    Stryker GmbH is recalling specific femoral nails because non-conforming cannulation may reduce strength and cause premature breakage.

    Product
    Femoral Nail, A/R, R1500 T2 Femur ¿12x300 mm, Product Number 18281230S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2394-2018·2018-07-18

    Stryker Recalls Two Femoral Nails Due to Potential Premature Breakage

    Stryker GmbH is recalling two femoral nails that may have non-conforming cannulation, potentially leading to reduced strength and premature breakage.

    Product
    Femoral Nail, A/R T2 Femur ¿10x320 mm, Product Number 18251032S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2419-2018·2018-07-18

    Medtronic EnTrust ICD Recall for Potential Loss of High Voltage Therapy

    Medtronic is recalling 8,821 EnTrust ICDs due to a potential loss of high voltage therapy near end-of-life. Patients should contact their healthcare provider.

    Product
    Medtronic EnTrust SingleChamber Implantable Cardioverter Defibrillator with Atrial and Ventricular Therapies and RapidRead Telemetry, D154VRC Product Usage: The implantable cardioverter defibrillator is intended to provide ventricular antitachycardia pacing and ventricular def
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2400-2018·2018-07-18

    Stryker Recalls Femoral Nails Due to Potential Premature Breakage

    Stryker GmbH is recalling specific femoral nails because non-conforming cannulation may reduce component strength and lead to premature breakage.

    Product
    Femoral Nail, A/R, R1500 T2 Femur ¿12x360 mm, Product Number 18281236S
    Category
    Medical Device
    Distribution
    8 states
  • SevereFDA (Devices)·Z-2346-2018·2018-07-11

    FHC Depth Stop Adapter Recalled for Lead and Stylet Damage

    FHC, Inc. is recalling the microTargeting Drive System because the Depth Stop Adapter can damage implanted leads and stylets when over-tightened, requiring device replacement.

    Product
    microTargeting" Drive System, Product Number MT-DS-01
    Category
    Medical Device
    Distribution
    46 states
  • SevereFDA (Devices)·Z-2345-2018·2018-07-11

    FHC microTargeting Drive System Recalled for Lead Damage Risk

    FHC, Inc. is recalling 2,952 microTargeting Drive Systems because over-tightening the depth stop screw can damage implanted leads, requiring replacement.

    Product
    microTargeting" Drive System, Product Number MT-DS
    Category
    Medical Device
    Distribution
    46 states
  • SevereFDA (Devices)·Z-2347-2018·2018-07-11

    FHC Depth Stop Adapter Recalled for Potential Lead Damage

    FHC, Inc. is recalling the microTargeting Drive System because the Depth Stop Adapter may damage implanted leads if over-tightened, potentially requiring replacement.

    Product
    microTargeting" Drive System, Product Number 66-ZD-MD
    Category
    Medical Device
    Distribution
    46 states
  • SevereFDA (Devices)·Z-2354-2018·2018-07-11

    FHC Depth Stop Adapter Recall for Potential Lead Damage

    FHC, Inc. is recalling microTargeting Lead Adapters because over-tightening the depth stop screw can damage implanted leads, requiring replacement.

    Product
    microTargeting" Lead Adapter for STar" Drive, Product Number 70-CN-DB
    Category
    Medical Device
    Distribution
    46 states
  • SevereFDA (Devices)·Z-2350-2018·2018-07-11

    FHC Depth Stop Adapter Recall Due to Lead and Stylet Damage

    FHC, Inc. is recalling the Depth Stop Adapter because over-tightening the screw can damage implanted leads and stylets, requiring replacement.

    Product
    microTargeting" STar" Drive System (Motorized), Product Number ST-DS-ME
    Category
    Medical Device
    Distribution
    46 states
  • SevereFDA (Devices)·Z-2352-2018·2018-07-11

    FHC Depth Stop Adapter Recalled for Potential Lead Damage

    FHC, Inc. is recalling the Depth Stop Adapter because over-tightening the screw can damage implanted leads, causing short circuits and requiring replacement.

    Product
    microTargeting" STar" Drive System (Motorized), Product Number 70-ZD-ME
    Category
    Medical Device
    Distribution
    46 states