The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

29051–29075 of 40449

  • ModerateFDA (Devices)·Z-2873-2016·2016-09-28

    Hospira LifeCare PCA Infusion System Recalled for Screw Rotation Error

    Hospira Inc. is recalling 8,794 LifeCare PCA Infusion Systems because a screw rotation error can cause the pump to alarm and stop infusion.

    Product
    LifeCare PCA Infusion System with Hospira MedNet Software, PCA Serial List Number 20709 Allows for clinician administration or self-administration of analgesic medications.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2854-2016·2016-09-28

    EKOS Intelligent Drug Delivery Catheter Recalled for Potential Epoxy Defect

    EKOS Corporation is recalling 10 Intelligent Drug Delivery Catheters due to potential non-compliant manufacturing tests that may cause epoxy blisters.

    Product
    EkoSonic Endovascular Devices EKOS Intelligent Drug Delivery Catheter
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2864-2016·2016-09-28

    Abbott Recalls Mislabeled Intraocular Lenses Due to Quality Control Failure

    Abbott Medical Optics is recalling 41 intraocular lenses because they were not checked prior to release, potentially resulting in mislabeled products.

    Product
    AMO TECNIS CL Foldable Silicone IOL with OptiEdge Design, Model No. Z9002 The product is indicated for implantation for the visual correction of aphakia in adult patients in whom a cataractous lens has been removed by extracapsular cataract extraction. The lens is intended to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2837-2016·2016-09-28

    Anspach Effort Recalls G1 Dissection Tools Due to Release Error

    The Anspach Effort, Inc. is recalling 177 G1 Dissection Tools because they were inadvertently released from hold status and distributed.

    Product
    G1 Dissection Tool - 7mm FBALL L; For cutting and shaping bone including spine and cranium.
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-2836-2016·2016-09-28

    SybronEndo Recalls Sealapex Xpress Root Canal Resin Due to Labeling Error

    SybronEndo is recalling 179 units of Sealapex Xpress root canal filling resin because the product was labeled with an incorrect expiration date.

    Product
    Sealapex Xpress, Part No. 33639 The brand name of the device is Sealapex Xpress, a root canal filling resin. Sealapex Xpress is intended to be used during endodontic therapy to fill the root canal of a tooth.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2865-2016·2016-09-28

    Merge Cardio software recall for missing patient information on report pages

    Merge Healthcare is recalling Merge Cardio software version 10.1 because patient information is missing from subsequent report pages.

    Product
    Merge Cardio software. Product Usage: Merge Cardio is an integrated cardiovascular information system classified as a picture archiving and communications system.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2844-2016·2016-09-28

    OrthoPediatrics Recalls Mislabeled 3.5mm Bowed Locking Compression Femur Plates

    OrthoPediatrics Corp is voluntarily recalling 41 units of 3.5mm Bowed Locking Compression Femur Plates due to mislabeling. The devices were distributed nationwide to specific states.

    Product
    3.5mm Bowed Locking Compression Femur Plates, 18 hole Orthopediatrics PediLoc Locking Plate System comes in sets that offer the advantage of both conventional and locking plate fixation devices and instrumentation in one system. Utilizing both locking and non- locking screws…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2863-2016·2016-09-28

    Abbott Recalls 41 Intraocular Lenses Due to Mislabeled Product Risk

    Abbott Medical Optics is recalling 41 TECNIS Multifocal Intraocular Lenses because they were not checked prior to release, posing a risk of mislabeling.

    Product
    TECNIS Multifocal Foldable Acrylic Intraocular Lens, Model No. ZMA00 The product is indicated for primary implantation for the visual correction of aphakia in adult patients with and without presbyopia in whom a cataractous lens has been removed by extracapsular cataract…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2845-2016·2016-09-28

    Biomet 3i Recalls 92 Dental Implants Due to Packaging Error

    Biomet 3i is recalling 92 units of 3I Osseotite dental implants because they were incorrectly packaged. The affected units were distributed in the US and several international countries.

    Product
    3I OSSEOTITE CERTAIN DENTAL IMPLANTS, 4x11.5 mm, Sterile, Rx only.
    Category
    Medical Device
    Distribution
    2 states
  • LowFDA (Devices)·Z-2851-2016·2016-09-28

    CooperSurgical Recalls Sage CSC Thawing Medium Due to Incorrect Package Insert

    CooperSurgical, Inc. is recalling 4 units of Sage CSC Thawing Medium because the products contain an international package insert instead of the correct USA package insert.

    Product
    Sage In-Vitro Fertilization- CSC (Choline Substituted Cryopreservation) Thawing Medium Product Number: ART-8018 Intended for use in freezing embryos. This product is intended for thawing of embryos frozen with ART-8017, CSC Freezing Medium. This kit is designed to be used in…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-2850-2016·2016-09-28

    Sage CSC Freezing Medium Recalled for Incorrect USA Package Insert

    CooperSurgical is recalling Sage CSC Freezing Medium because it shipped with an international package insert instead of the correct USA version.

    Product
    Sage In-Vitro Fertilization- CSC (Choline Substituted Cryopreservation) Freezing Medium . Product Number: ART -8017 SAGE In Vitro Fertilization, Inc. A CooperSurgical Company 95 Corporate Drive Trumbull, CT 06611 USA
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2790-2016·2016-09-21

    Hospira MedNet Software Recall for Incorrect Bolus Calculations

    Hospira is recalling MedNet 6.1 software used with SapphirePlus infusion pumps because it may calculate incorrect bolus amounts for drugs in Million Units.

    Product
    Hospira MedNet Medication Management Suite software, version 6.1, List Numbers 16037-64-02 and 16037-64-03, in combination with the SapphirePlus 13.1x infusion pump Hospira MedNet Medication Management Suite is intended to facilitate networked communication between compatible…
    Category
    Medical Device
    Distribution
    13 states
  • HighFDA (Devices)·Z-2808-2016·2016-09-21

    ICU Medical Recalls Transpac IV Monitoring Kits Due to Leak Risk

    ICU Medical is recalling specific Transpac IV Monitoring Kits because of a potential for leaks in the SafeSet Reservoir and blood sampling components.

    Product
    Transpac IV Monitoring Kit with 2 SafeSet Blood Sampling Ports, 60" TUBING, Disposable Transducer, 3 ML Intraflo Flush, Macrodrip (Pole Mount), Item No. 42619-08 Usage: The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2786-2016·2016-09-21

    Howmedica Recalls AccuLIF PL Spinal Cages Due to Height Reduction

    Howmedica Osteonics Corp. is recalling AccuLIF PL spinal cages because some implants have shown a reduction in height greater than 1 mm after surgery.

    Product
    AccuLIF PL 6-9mm x 11mm x 27mm x 8 Cage, Rx only, Sterile R, Legal The AccuLIF PL Cages are indicated for intervertebral body fusion with autograft and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone graft when the subject device is used as an…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2820-2016·2016-09-21

    ICU Medical Recalls SafeSet Reservoir Kits Due to Leak Risk

    ICU Medical is recalling 20 units of Bifurcated SafeSet Kits with 03mL Flush Devices due to a potential for leaks.

    Product
    Bifurcated SafeSet Kit with 03mL Flush Device, Item No. 46091-75 Product Usage: The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by converting changes in pressure…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2805-2016·2016-09-21

    ICU Medical Recalls Transpac IV Monitoring Kits Due to Leak Risk

    ICU Medical is recalling 420 Transpac IV Monitoring Kits with SafeSet Reservoirs due to a potential leak. The affected units were distributed nationwide in the US.

    Product
    Transpac IV Monitoring Kit with SafeSet 84inch Arterial Pressure Tubing, Reservoir, Squeeze Flush and 2 Needleless Valves, Item No. 011-42646-66 Usage: The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2796-2016·2016-09-21

    Merge Healthcare Recalls RadSuite Software Due to Missing Studies

    Merge Healthcare is recalling RadSuite software versions where studies may be missing from archives before watermarking.

    Product
    RadSuite software. The firm name on the label is Merge Healthcare, Hartland, WI.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2799-2016·2016-09-21

    Siemens RAPIDPoint 500 Blood Gas Analyzer Recalled for Data Mismatch

    Siemens Healthcare Diagnostics Inc is recalling 6,786 RAPIDPoint 500 Blood Gas Analyzers because patient names may be printed with data from a different patient.

    Product
    Siemens RAPIDPoint 500 Blood Gas Analyzer Siemens Material Number (SMN): 10492730, 10696855, 10696857, 10697306
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2813-2016·2016-09-21

    ICU Medical Recalls Transpac IV Monitoring Kits Due to Leak Risk

    ICU Medical is recalling 90 units of Transpac IV Trifurcated Monitoring Kits due to a potential for leaks in the SafeSet Reservoir and blood sampling components.

    Product
    Transpac IV Trifurcated Monitoring Kit with 84" SafeSet Reservoir, 03 ml Squeeze Flush and Needleless Valves, Item No. 42650-66 Product Usage: The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2802-2016·2016-09-21

    Siemens RAPIDLab 1260 Blood Gas Analyzer Recalled for Data Mismatch

    Siemens is recalling 114 RAPIDLab 1260 Blood Gas Analyzers because patient names may be printed with data from different patients.

    Product
    RAPIDLab 1260 Blood Gas Analyzer Siemens Material Number (SMN): 10321846, 10491394
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2806-2016·2016-09-21

    ICU Medical Recalls Transpac IV Trifurcated Kits Due to Leak Risk

    ICU Medical is recalling 250 units of Transpac IV Trifurcated Kits due to a potential leak in the SafeSet Reservoir and blood sampling components.

    Product
    Transpac IV Trifurcated Kit With Safeset Reservoir And 2 Blood Sampling Ports, 84 inch Tubing, 3 3 ml Intraflo Flushes, 3 Disposable Transducers, Macrodrip, Item No. 42500-04 Usage: The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2825-2016·2016-09-21

    ICU Medical Recalls Transpac IV Transducer Kits Due to Leak Risk

    ICU Medical is recalling 140 units of TP4 Kits with SafeSet Reservoirs due to a potential for leaks. The affected medical devices were distributed nationwide.

    Product
    TP4 Kit with 10cc SafeSet Reservoir, Needleless Valve, Filter Millex and Admin Set, Item No. 46104-65 Usage: The Transpac Disposable Straight Pressure Transducer (DSPT) is an extravascular pressure transducer that interfaces between a catheter and pressure monitor by…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2789-2016·2016-09-21

    Stryker Patella Assembly Instrument Recalled for Component Disassociation Risk

    Stryker Howmedica Osteonics is recalling 2,039 units of the Scorpio Patella Assembly Instrument because press-fit failures could cause clamping components and pins to disassociate.

    Product
    Stryker Orthopaedics Patella Assembly Instrument, REF 3182-1000, Non-Sterile, NDC (01) 07613327215854 (10) The Scorpio Patella Assembly Instrument is used during total knee replacement surgery for the implantation of Scorpio Patella implant components. The device functions to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2788-2016·2016-09-21

    Howmedica Recalls AccuLIF PL Cages Due to Height Reduction

    Howmedica Osteonics Corp. is recalling AccuLIF PL Cages because some implants have shown a reduction in height greater than 1 mm.

    Product
    AccuLIF PL 10-16mm x 11mm x 27mm x 8 Cage, Rx only, Sterile R, Legal The AccuLIF PL Cages are indicated for intervertebral body fusion with autograft and/or allogeneic bone graft comprised of cancellous and/or corticocancellous bone graft when the subject device is used as an…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2798-2016·2016-09-21

    Siemens RAPIDPoint 405 Blood Gas Analyzer Recalled for Data Mismatch

    Siemens is recalling RAPIDPoint 405 Blood Gas Analyzers because patient names may be printed with results from a different patient.

    Product
    Siemens RAPIDPoint 405 Blood Gas Analyzer nBili Siemens Material Number (SMN): 10282093, 10310464, 10314817, 1031 7193, 10318999, 10320055, 10321238, 10322347, 10328278, 10328302, 10336784
    Category
    Medical Device
    Distribution
    Distributed nationwide