The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

26226–26250 of 40357

  • HighFDA (Devices)·Z-2667-2017·2017-07-12

    Exactech Equinoxe Reamer Recalled for Updated Instructions on Glenoid Reaming

    Exactech is recalling the Equinoxe Narrow Modular Reverse Pilot-Tip Starter Reamer to update instructions for use, clarifying proper reaming technique to prevent instrument breakage.

    Product
    EXACTECH Equinoxe Narrow Modular Reverse Pilot-Tip Starter Reamer Catalog #: 321-45-01
    Category
    Medical Device
    Distribution
    33 states
  • HighFDA (Devices)·Z-2684-2017·2017-07-12

    Ion Beam Applications Recalls Proteus 235 Proton Therapy Systems Due to Software Issue

    Ion Beam Applications S.A. is voluntarily recalling six Proteus 235 Proton Therapy Systems worldwide due to a software issue. Five of these units are located in the United States.

    Product
    Proteus 235, Proton Therapy System Product Usage: The Proton Therapy System - Proteus 235 is a medical device designed to produce and deliver a proton beam for the treatment of patients with localized tumors and other conditions susceptible to treatment by radiation. The PTS…
    Category
    Medical Device
    Distribution
    5 states
  • HighFDA (Devices)·Z-2688-2017·2017-07-12

    Siemens Sensis Vibe Systems Recalled for Software Error in Report Generation

    Siemens is recalling 13 Sensis Vibe diagnostic computers in the US due to a software error that may combine patient data from different examinations into a single report.

    Product
    Sensis Vibe Systems with Software Version VD10B, Model Numbers 10765502, 10910620, 11007641, 6648161 --- Programmable diagnostic computer,
    Category
    Medical Device
    Distribution
    3 states
  • HighFDA (Devices)·Z-2670-2017·2017-07-12

    Smiths Medical Recalls Hypodermic Needles Due to Syringe Hub Defects

    Smiths Medical is recalling specific lots of Jelco Hypodermic Needle Pro needles because syringe assemblies used in their manufacture contained pin holes in the hub.

    Product
    Jelco, Hypodermic needle Pro¿ needles 19G X1 1/2" 800/CA Model No. EL 1915 & 19G X 2" 600/CA Model No. SB 5021, Rx Only, Sterile EO.
    Category
    Medical Device
    Distribution
    1 state
  • HighFDA (Devices)·Z-2685-2017·2017-07-12

    PerkinElmer Multiphor II Electrophoresis System Recalled for Electric Shock Risk

    PerkinElmer is recalling 241 Multiphor II Electrophoresis Systems due to a potential electric shock hazard if grommets are not installed.

    Product
    Multiphor II Electrophoresis System GE HealthCare Product Number: 18-1018-06 PerkinElmer Part Number: 2117-004 Product Usage: Multiphor II Electrophoresis System is a versatile modular electrophoresis system for horizontal electrophoresis, isoelectric focusing, 2-D…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-2656-2017·2017-07-12

    JAS Diagnostics Recalls Drew Scientific DREW 3-PAC Reagent Kits

    JAS Diagnostics Inc. is recalling 14,064 units of Drew Scientific DREW 3-PAC Reagent Kits because they may result in elevated platelet backgrounds during routine startup checks.

    Product
    Drew Scientific DREW 3-PAC Reagent Kit containing: 5L Diluent, 750 mL Enzymatic Cleaner, and 125 mL Lysing Reagent.
    Category
    Medical Device
    Distribution
    18 states
  • ModerateFDA (Devices)·Z-2672-2017·2017-07-12

    Ion Beam Applications Recalls Proteus Proton Therapy Systems for Software Issues

    Ion Beam Applications is recalling Proteus 235 and Proteus ONE proton therapy systems because on-site software installations were not performed consistently with standard operating procedures.

    Product
    Proteus 235 and Proteus ONE proton therapy systems
    Category
    Medical Device
    Distribution
    10 states
  • ModerateFDA (Devices)·Z-2658-2017·2017-07-12

    Encore Medical Recalls 3DKnee Tibial Inserts Due to Mis-packaging Error

    Encore Medical is recalling 9 units of 3DKnee Tibial Inserts because a size 6 left box contained a size 8 right insert.

    Product
    3DKNEE(TM) SYSTEM e+, tibial Insert, LEFT Sz 6 / 11mm, REF 391-11-706, QTY 01, The 3DKnee Insert HXL Tibial Inserts are manufactured from ultra high molecular weight polyethylene (UHMWPE) infused with pure liquid pharmaceutical grade alpha-tocopheral and then cross-linked to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-2665-2017·2017-07-12

    Exactech Equinoxe Modular Reverse Pilot-Tip Starter Reamer Recall

    Exactech is recalling 928 Equinoxe Modular Reverse Pilot-Tip Starter Reamers to update instructions for use. The update clarifies proper reaming technique to prevent instrument breakage.

    Product
    EXACTECH Equinoxe Modular Reverse Pilot-Tip Starter Reamer - Catalog #: 321-25-01
    Category
    Medical Device
    Distribution
    33 states
  • ModerateFDA (Devices)·Z-2664-2017·2017-07-12

    Exactech Equinoxe Glenoid Reamer Recalled for Updated Instructions

    Exactech is recalling Equinoxe Glenoid Reamers to update instructions for use, clarifying that off-axis reaming may cause instrument breakage.

    Product
    EXACTECH Equinoxe Glenoid Reamer - Catalog #: 321-05-38, Catalog #: 321-05-42, and Catalog #: 321-05-46
    Category
    Medical Device
    Distribution
    33 states
  • ModerateFDA (Devices)·Z-2668-2017·2017-07-12

    Exactech Equinoxe Reamer Recall Due to Updated Instructions for Use

    Exactech is recalling Equinoxe Narrow Modular Reverse Pilot-Tip Reamers to update instructions for use, clarifying that off-axis reaming may cause instrument breakage.

    Product
    EXACTECH Equinoxe Narrow Modular Reverse Pilot-Tip Reamer // Catalog #: 321-45-38, Catalog #: 321-45-42 and Catalog #: 321-45-46
    Category
    Medical Device
    Distribution
    33 states
  • ModerateFDA (Devices)·Z-2687-2017·2017-07-12

    Mallinckrodt Recalls ArterX Surgical Sealant Due to Improper Labeling

    Mallinckrodt is recalling ArterX Surgical Sealant because improper labeling led to improper storage. The affected units were distributed to the UK.

    Product
    Tenaxis Medical ArterX(TM) Surgical Sealant, (a) 4mL, REF 9002, and (b) 5mL REF 9006, STERILE R, Store at 2oC - 8oC Adjunct to sutures in vascular surgery.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2661-2017·2017-07-12

    Medacta GMK Hinge Tibial Insert Recalled for Missing Attachment Screw

    Medacta USA Inc. is recalling one lot of GMK Hinge Tibial Inserts because they are missing a screw required for attachment to the tibial base plate.

    Product
    Medacta GMK HINGE, Tibial Insert Fixed, SIZE 2, HEIGHT 23 mm, REF 02.09.0223H, STERILE EO
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-2663-2017·2017-07-12

    Exactech Equinoxe Reverse Starter Reamer Recalled for Updated Instructions

    Exactech is recalling 382 Equinoxe Reverse Starter Reamers to update instructions for use, clarifying that off-axis reaming may cause instrument breakage.

    Product
    EXACTECH Equinoxe Reverse Starter Reamer - Catalog #: 321-05-01
    Category
    Medical Device
    Distribution
    33 states
  • ModerateFDA (Devices)·Z-2674-2017·2017-07-12

    Boston Scientific Retrieval Balloon Catheter Recalled for Incorrect Injection Labeling

    Boston Scientific is recalling 32 units of Extractor Pro RX-S Retrieval Balloon Catheters because the labels incorrectly identify the injection location relative to the balloon.

    Product
    Boston Scientific Extractor Pro RX-S Retrieval Balloon Catheter 12-15mm Below UPN: M00547340
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Devices)·Z-2662-2017·2017-07-12

    Exactech Recalls Logic Fit Tibial Tamp Heads for Labeling Clarification

    Exactech, Inc. is recalling 573 Logic Fit Tibial Tamp Heads to update surgical labeling. The update clarifies proper removal techniques to prevent instrument breakage.

    Product
    Logic Fit Tibial Tamp Head
    Category
    Medical Device
    Distribution
    32 states
  • ModerateFDA (Devices)·Z-2689-2017·2017-07-12

    Beckman Coulter PrepPlus Recalled for Imprecise Sample Preparation

    Beckman Coulter is recalling 43 PrepPlus systems because they may produce imprecise absolute counts in the first tube of a flow cytometry run.

    Product
    Coulter PrepPlus, Part Number 286600, Product Usage: The COULTER PrepPlus is a microprocessor-controlled pipetting and diluting system designed for automating sample preparation or assay methods. It is capable of aspirating and dispensing liquid samples.
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2673-2017·2017-07-12

    Boston Scientific Retrieval Balloon Catheter Recalled for Labeling Error

    Boston Scientific is recalling 39 units of the Extractor Pro RX-S Retrieval Balloon Catheter because the label incorrectly identifies the injection location.

    Product
    Boston Scientific Extractor Pro RX-S Retrieval Balloon Catheter 9-12mm Above UPN: M00547300
    Category
    Medical Device
    Distribution
    2 states
  • ModerateFDA (Devices)·Z-2669-2017·2017-07-12

    Sterilmed Recalls Reprocessed EP Ablation Cables Due to Regulatory Status

    Sterilmed is recalling 963 reprocessed EP ablation cables because they are Class III devices that lack required premarket approval.

    Product
    Electrophysiology catheter cables are designed as electrode cables with a multi-pin connector on the distal end and the appropriate number of tails on the proximal end. The cables serve two different purposes. They either serve as an extension between an EP catheter and…
    Category
    Medical Device
    Distribution
    17 states
  • ModerateFDA (Devices)·Z-2690-2017·2017-07-12

    Beckman Coulter PrepPlus 2 Recalled for Sample Preparation Imprecision

    Beckman Coulter is recalling 473 PrepPlus 2 units because they may produce imprecise absolute counts in the first tube of a flow cytometry run.

    Product
    Coulter PrepPlus 2, Part Number 378600, Product Usage: The COULTER PrepPlus 2, when used in combination with the COULTER TQPrep Workstation, is intended to prepare human whole blood for In Vitro Diagnostic (IVD) Use with cleared Beckman Coulter IVD applications on cleared…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-2666-2017·2017-07-12

    Exactech Equinoxe Modular Reverse Pilot-Tip Reamer Recall for Labeling Clarification

    Exactech is recalling Equinoxe Modular Reverse Pilot-Tip Reamers to update instructions for use, clarifying that off-axis reaming may cause instrument breakage.

    Product
    EXACTECH Equinoxe Modular Reverse Pilot-Tip Reamer, Catalog #: 321-25-38, Catalog #: 321-25-42 and Catalog #: 321-25-46
    Category
    Medical Device
    Distribution
    33 states
  • ModerateFDA (Devices)·Z-2645-2017·2017-07-12

    Boston Scientific Imager II Angiographic Catheter Recall for Missing Seal

    Boston Scientific is recalling Imager II Angiographic Catheters because some units are missing the bottom pouch seal. The defect is obvious to the user.

    Product
    Boston Scientific Imager II Angiographic Catheter, a pathway for delivering contrast media to selected sites in the vascular system. M001314141 (5-pack outer package UPN), M001314140, single unit, inner package UPN)
    Category
    Medical Device
    Distribution
    9 states
  • LowFDA (Devices)·Z-2659-2017·2017-07-12

    Encore Medical Recalls 3DKnee Tibial Inserts Due to Mis-Packaging

    Encore Medical is recalling 3DKnee Tibial Inserts because a size 6 left box contained a size 8 right insert.

    Product
    3DKNEE(TM) SYSTEM e+, Tibial Insert, RIGHT Sz 8 / 11mm, REF 391-11-708, QTY 01 The 3DKnee Insert HXL Tibial Inserts are manufactured from ultra high molecular weight polyethylene (UHMWPE) infused with pure liquid pharmaceutical grade alpha-tocopheral and then cross-linked to…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-2639-2017·2017-07-05

    DeRoyal Dolphin Inflation Device Recalled for Sterility Assurance Defect

    DeRoyal Industries is recalling 426 Dolphin Inflation Devices due to a primary packaging defect that may compromise sterility.

    Product
    DeRoyal(R) Dolphin Inflation Device, REF 0185ND, Rx Only, STERILE EO, Dolphin is an inflation device indicated during angioplasty procedures to inflate and deflate the balloon catheter, and control pressure.
    Category
    Medical Device
    Distribution
    Distributed nationwide