The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

21351–21375 of 40175

  • HighFDA (Devices)·Z-0820-2019·2019-02-13

    Bone Marrow Biopsy Needle Recall Due to Sterile Seal Manufacturing Issue

    Angiotech is recalling 504 bone marrow biopsy needles due to a manufacturing issue affecting the sterile seal on blister trays.

    Product
    Aguja de Aspiration con Profundidad Ajustable Tipo I 15ga x 5 cm - Product Usage: Manual surgical instruments for Bone Marrow Biopsy and Aspiration.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0814-2019·2019-02-13

    Angiotech Recalls Bone Marrow Biopsy Needles Due to Sterile Seal Defect

    Angiotech is recalling specific lots of bone marrow biopsy needles because a manufacturing issue may have compromised the sterile seal on the blister trays.

    Product
    "J" Type Bone Marrow Needle 11ga x 10 cm - Product Usage: Manual surgical instruments for Bone Marrow Biopsy and Aspiration.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0776-2019·2019-02-13

    GE Healthcare Recalls Revolution CT Systems with SmartStep Option

    GE Healthcare is recalling 131 Revolution CT systems with the SmartStep Option because the displayed Z location may not match the actual table position, potentially causing scans at incorrect locations.

    Product
    Revolution CT systems with the SmartStep Option The system is intended for head, whole body, cardiac and vascular X-ray Computed Tomography applications.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0797-2019·2019-02-13

    Handpiece Headquarters Recalls Henry Schein CU 1000 Halogen Curing Lights

    Handpiece Headquarters is recalling 252 Henry Schein CU 1000 Halogen Curing Lights because the tip became too hot, causing heat sensations in patients.

    Product
    Henry Schein CU 1000 Halogen Curing Light, Catalog 900-4542. - Product Usage: Curing light for use in dentistry. The labeling did not provide specific details for intended use. Distributed by Henry Schein Inc., Melville, NY.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0817-2019·2019-02-13

    Bone Marrow Biopsy Needle Recall Due to Sterile Seal Manufacturing Issue

    Angiotech is recalling 500 units of Double Diamond J Type Bone Marrow Needles due to a manufacturing defect in the sterile seal on blister trays.

    Product
    Double Diamond J Type Bone Marrow Needle & Marrow Extraction Cannula 11ga x 10cm 14MTWX x 12.5 cm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0816-2019·2019-02-13

    Angiotech Recalls Bone Marrow Needles Due to Sterile Seal Manufacturing Issue

    Angiotech is recalling 180 units of J Type Bone Marrow Needles due to a manufacturing issue affecting the sterile seal on blister trays.

    Product
    J Type Bone Marrow Needle 13ga x 6cm - Product Usage: Manual surgical instruments for Bone Marrow Biopsy and Aspiration.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-0793-2019·2019-02-13

    GE Healthcare Recalls Centricity Universal Viewer Breast Imaging Software

    GE Healthcare is recalling Centricity Universal Viewer Breast Imaging software because a display error could lead to incorrect patient diagnoses.

    Product
    GE Healthcare Centricity Universal Viewer Breast Imaging Centricity Universal Viewer is a device that displays medical images and data from various imaging sources, and from other healthcare information sources. Medical images and data can be displayed, communicated…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0800-2019·2019-02-13

    Bard SureStep Foley Tray System Recalled for Potential Sample Port Leaks

    Bard Medical Division is recalling 450 units of SureStep Foley Tray Systems because the sample ports may leak urine.

    Product
    BARD SureStep Foley Tray System Bardex I.C. Complete Care Temperature Sensing Infection Control Foley Catheter with Bard Hydrogel and Bacteria-Guard Silver Alloy Coating. Sterile. Intended for use in the drainage and/or collection and/or measurement of urine.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0798-2019·2019-02-13

    Abbott Recalls Free T3 Reagent Kits Due to Carryover Issues

    Abbott Ireland Diagnostics Division is recalling ARCHITECT Free T3 Reagent Kits because reagent carryover may cause depressed test results on specific platforms.

    Product
    ARCHITECT Free T3 Reagent Kit used on ARCHITECT i1000SR or i2000/i2000SR platforms Product Usage: It is a Chemiluminescent Microparticle Immunoassay (CMIA) for the quantitative determination of free triiodothyronine (Free T3) in human serum and plasma.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0804-2019·2019-02-13

    Richard Wolf Bronchoscope Tubes Recalled for Potential Bonding Defects

    Richard Wolf GmbH is recalling 873 Bronchoscope Tubes, Model Texas, because non-functional bonding points may loosen. The devices are used for respiratory tract investigation and therapy.

    Product
    Richard Wolf Bronchoscope Tubes, Model Texas. Device is reusable and should be sterilized prior to each use. Product Usage: Bronchoscopes are intended for investigation, diagnosis and therapy of pathological changes and removal of foreign bodies in the area of the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0796-2019·2019-02-13

    Medtronic CareLink Encore 29901 Programmer Recalled for Usage Restrictions

    Medtronic is recalling CareLink Encore 29901 programmers to ensure they are used only for Medtronic or Vitatron implantable devices by trained personnel.

    Product
    MEDTRONIC CARELINK 29901 Programmer for Medtronic and Vitaron Devices
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0815-2019·2019-02-13

    Angiotech Recalls Bone Marrow Biopsy Needles Due to Sterile Seal Defect

    Angiotech is recalling 1,260 bone marrow biopsy needles due to a manufacturing issue affecting the sterile seal on blister trays.

    Product
    J Type Bone Marrow Needle 13ga x 10 cm- Product Usage: Manual surgical instruments for Bone Marrow Biopsy and Aspiration.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0818-2019·2019-02-13

    Bone Marrow Biopsy Needle Recall Due to Sterile Seal Manufacturing Issue

    Angiotech is recalling 1,404 Bone Marrow Biopsy Needles due to a manufacturing defect in the sterile seal on blister trays.

    Product
    Aguja de Aspiracion con Profundidad Ajustable Tipo I 16ga x 5 cm- Product Usage: Manual surgical instruments for Bone Marrow Biopsy and Aspiration.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0795-2019·2019-02-13

    Medtronic CareLink 2090 Programmer Recalled for Longevity Display Error

    Medtronic is recalling CareLink 2090 programmers because they may incorrectly display the remaining longevity value for up to two years before the device reaches its Recommended Replacement Time.

    Product
    MEDTRONIC CARELINK 2090 programmer
    Category
    Medical Device
    Distribution
    1 state
  • ModerateFDA (Devices)·Z-0799-2019·2019-02-13

    Abbott Recalls ARCHITECT Total T3 Reagent Kits Due to Carryover

    Abbott Ireland Diagnostics Division is recalling ARCHITECT Total T3 Reagent Kits because reagent carryover may cause depressed test results on specific platforms.

    Product
    ARCHITECT Total T3 Reagent Kit used on ARCHITECT i1000SR or i2000/i2000SR platforms Product Usage: It is a Chemiluminescent Microparticle Immunoassay (CMIA) for the quantitative determination of free triiodothyronine (Free T3) in human serum and plasma.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-0773-2019·2019-02-13

    NeuViz 128 CT Scanner Recalled for Potential Image Field of View Error

    Neusoft Medical Systems is recalling three NeuViz 128 CT scanners because a software defect may cause incorrect image field of view, potentially leading to misaligned clinical scans.

    Product
    NeuViz 128 Multi-slice CT Scanner System with software version 1.0.8.5010O+P04 Vi .0.8.521 9+PO1 Multi-Slice CT Scanner System can be used as a whole body computed tomography X-ray system featuring a continuously rotating X-ray tube and detector array. The acquired X-RAY…
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-0803-2019·2019-02-13

    Bard Medical Recalls SureStep Foley Tray System Due to Leakage Risk

    Bard Medical Division is recalling SureStep Foley Tray Systems because urine may leak around the vent on the vented sample port.

    Product
    SureStep(TM) FOLEY TRAY SYSTEM, Preconnected Closed System Foley Tray, Product Codes: A119214M, A119216M, A119218M, A119416M, A153200, A300916A, A301216, A301216A, A303314A, A303316A, A303318A, A303414A, A303416A, A303418A, A304400A, A304714A, A304716A, A304718A, A304914…
    Category
    Medical Device
    Distribution
    0 states
  • ModerateFDA (Devices)·Z-0819-2019·2019-02-13

    Bone Marrow Biopsy Needle Recall Due to Sterile Seal Manufacturing Issue

    Angiotech is recalling 2,502 bone marrow biopsy needles due to a manufacturing issue affecting the sterile seal on blister trays.

    Product
    Aguja para Biopsia Tipo Medula Osea Ergonomica 11ga x 10cm
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • LowFDA (Devices)·Z-0794-2019·2019-02-13

    Ascension Radial Head Implant Recalled for Incorrect Instructions for Use

    Ascension Orthopedics is recalling specific Radial Head Implants because they were packaged with instructions for a different product.

    Product
    Ascension Modular Radial Head (MRH) Radial Head Implant, Catalog Number, MRH-350-04-WW
    Category
    Medical Device
    Distribution
    1 state
  • LowFDA (Devices)·Z-0792-2019·2019-02-13

    BD FACSLyric Flow Cytometer Recalled Due to Unsupported Operating System Configuration

    Becton, Dickinson and Company is recalling three BD FACSLyric flow cytometers because they were installed with an unsupported Windows 10 operating system configuration.

    Product
    BD FACSLyric 3L 10C with FACSuite Clinical Software v1.1.1, catalog number 662878 BD FACSLyric is a high-performance flow cytometer designed to support both routine clinical analysis and research for the identification, quantification, and characterization of cells in support…
    Category
    Medical Device
    Distribution
    1 state
  • CriticalFDA (Devices)·Z-0765-2019·2019-02-06

    Edwards Lifesciences Recalls Swan Ganz Catheters Due to Lumen Reversal

    Edwards Lifesciences is recalling 459 Swan Ganz Thermodilution Catheters because incorrect lumen assembly causes reversed pressure readings, potentially leading to misdiagnosis.

    Product
    Edwards Lifesciences Swan Ganz Thermodilution Catheter, REF 151F7 Product Usage: The Swan-Ganz Thermodilution Catheter provides a diagnostic tool for physicians to rapidly determine hemodynamic pressures and cardiac output when used with a compatible cardiac output computer.…
    Category
    Medical Device
    Distribution
    0 states
  • CriticalFDA (Devices)·Z-0764-2019·2019-02-06

    Edwards Lifesciences Recalls Swan Ganz Catheters Due to Lumen Assembly Error

    Edwards Lifesciences is recalling 9 units of Swan Ganz Thermodilution Catheters because incorrect lumen assembly causes reversed pressure readings.

    Product
    Edwards Lifesciences Swan Ganz Thermodilution Catheter, REF 131VF7P Product Usage: The Swan-Ganz Thermodilution Catheter provides a diagnostic tool for physicians to rapidly determine hemodynamic pressures and cardiac output when used with a compatible cardiac output…
    Category
    Medical Device
    Distribution
    0 states
  • SevereFDA (Devices)·Z-0769-2019·2019-02-06

    West Pharma Services Recalls Vial2BAG DC 20mm Medical Devices

    West Pharma Services is recalling Vial2BAG DC 20mm devices because adverse events were reported with the similar 13mm model used with oxytocin in pregnant women.

    Product
    Vial2BAG DC 20mm: 1) REF 6070112 & 2) REF 6070112C, Single use only, Rx Only
    Category
    Medical Device
    Distribution
    1 state
  • SevereFDA (Devices)·Z-0768-2019·2019-02-06

    FDA Recalls Vial2BAG Transfer Device Due to Reported Adverse Events

    West Pharma Services is recalling Vial2BAG Transfer Devices because adverse events were reported when used with oxytocin in pregnant women.

    Product
    Vial2BAG Transfer Device, REF 6070104, Single use only, Rx Only
    Category
    Medical Device
    Distribution
    1 state