The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means the agency’s own highest classification or reported deaths or serious injuries, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

20601–20625 of 40124

  • HighFDA (Devices)·Z-1543-2019·2019-06-05

    Maquet Getinge Infant Custom Tubing Sets Recalled for Sterility Assurance Issues

    Maquet Cardiovascular is recalling specific infant custom tubing sets for extracorporeal circulation because the sterilization process may not have ensured sterility at the stopcock ports.

    Product
    Maquet Getinge-BEQ-TOP 38302 INFANT CPS QPID Material: 701055866
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1592-2019·2019-06-05

    Maquet Getinge ECC Tubing Sets Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific ECC tubing sets because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 8207 1/4" ECC PACK Material: 701068395
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1557-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design configuration may prevent proper sterilization of stopcock ports.

    Product
    Maquet Getinge-BEQ-T 5908 TCH HLS ANCILLARY Material: 701064590
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1541-2019·2019-06-05

    Maquet Getinge-BEQ-TOP Adult Specialty Tubing Sets Recalled for Sterility Concerns

    Maquet Cardiovascular is recalling specific adult specialty tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 38002 ADULT SPECIALTY Material:
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1614-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BO-T 51502 Ochsner ECC Adult Pack Material: 709000385
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1624-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design configuration may prevent sterilization gas from reaching all fluid paths.

    Product
    Maquet Getinge-BEQ-TOP 25503 TMC ¿ with BB & QiD Pedi Material:709000473
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1650-2019·2019-06-05

    Maquet Custom Tubing Sets Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent proper sterilization of the stopcock ports.

    Product
    Maquet Getinge-BEQ-TOP 9004 1/4 Custom Pk w/RF32 & HMOD Material: 701054451R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1565-2019·2019-06-05

    Maquet Getinge Pediatric Pack Recall Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific pediatric packs for extracorporeal circulation because a design issue may prevent proper sterilization of the stopcock ports.

    Product
    Maquet Getinge-BEQ-T 8069 Pediatric Pack Material: 701064965
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1561-2019·2019-06-05

    Maquet Pediatric ECC Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling pediatric extracorporeal circulation tubing sets because a design feature may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-TOP 44701 PEDIATRIC ECC Material: 701064825
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1505-2019·2019-06-05

    Maquet Small Patient Tubing Recalled Due to Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific Small Patient Tubing Packs because a design flaw may prevent proper sterilization, potentially compromising sterility.

    Product
    Maquet Getinge-BEQ-T 9403 Small Patient Tubing Pack Material: 701049994
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1568-2019·2019-06-05

    Maquet Getinge Custom Tubing Sets Recalled for Sterility Assurance Concerns

    Maquet Cardiovascular is recalling specific custom tubing sets for extracorporeal circulation because a design feature may prevent proper sterilization gas flow, potentially compromising sterility.

    Product
    Maquet Getinge-BO-T 41301 BUMC ECC PACK Material: 701065209
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1634-2019·2019-06-05

    Maquet Cardiovascular Recalls Custom Tubing Sets for Extracorporeal Circulation

    Maquet Cardiovascular is recalling custom tubing sets for extracorporeal circulation because a design flaw may prevent sterilization gas from reaching all parts of the device.

    Product
    Maquet Getinge-BEQ-TOP 21502 ECC Quadrox iD w/RF 3/8" Material:701050060R01
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1681-2019·2019-06-05

    King LTS-D Kit Size 1 Recalled for Incorrect Packaging and Labeling

    King Systems Corp. dba Ambu, Inc. is recalling 270 King LTS-D Kit Size 1 units because they were incorrectly packaged and labeled as size 1 products.

    Product
    King LTS-D Kit Size 1, Model Number KLTSD431
    Category
    Medical Device
    Distribution
    11 states
  • ModerateFDA (Devices)·Z-1492-2019·2019-06-05

    K2M Fenestrated Tap Adapter Recalled for Mislabeled Packaging

    K2M, Inc. is recalling 462 Fenestrated Tap Adapters because the products are mislabeled. The devices are used for bone biopsies and vertebral body augmentation.

    Product
    Fenestrated Tap Adapter (REF# 5001-90011) Product Usage: The K2M Fenestrated Tap System is intended for use as a standalone biopsy tool to remove a sample of bone tissue from a vertebral body for diagnostic purposes using an aspiration technique, as well as to provide and…
    Category
    Medical Device
    Distribution
    6 states
  • ModerateFDA (Devices)·Z-1686-2019·2019-06-05

    Teleflex Medical Recalls RUSCH LASERTUBE Due to Partial Foil Separation

    Teleflex Medical is recalling 2,325 units of RUSCH LASERTUBE (Rubber) because the laser guard foil partially separated or detached at the edges.

    Product
    RUSCH LASERTUBE (Rubber), Order No. : 102004-000080, REF 102004, SIZE I.D. mm 8,0
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • ModerateFDA (Devices)·Z-1690-2019·2019-06-05

    Exactech Recalls Opteform Allograft Discs Due to Cold Storage Failure

    Exactech is recalling three units of Opteform Allograft Discs because they were potentially exposed to higher temperatures than documented due to cold storage equipment failure.

    Product
    Opteform Allograft Disc, 90mm x 5mm, 22cc, Catalog Number 600-03-90
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-1688-2019·2019-06-05

    Exactech Recalls Opteform Allograft Discs Due to Cold Storage Failure

    Exactech is recalling two units of Opteform Allograft Discs because they were potentially exposed to higher temperatures than documented due to a cold storage equipment failure.

    Product
    Opteform Allograft Disc, 30mm 3mm, 2cc, Catalog Number 600-03-30
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-1689-2019·2019-06-05

    Exactech Recalls Opteform Allograft Discs Due to Cold Storage Failure

    Exactech, Inc. is recalling two units of Opteform Allograft Discs because they were potentially exposed to higher temperatures than documented due to a cold storage equipment failure.

    Product
    Opteform Allograft Disc, 45mm x 5mm, 8cc, Catalog Number 600-03-45
    Category
    Medical Device
    Distribution
    3 states
  • ModerateFDA (Devices)·Z-1491-2019·2019-06-05

    K2M Fenestrated Taps Recalled for Mislabeled Packaging

    K2M, Inc. is recalling 462 Fenestrated Taps because the products are mislabeled. The devices were distributed to six US states.

    Product
    Fenestrated Taps 4.5mm, 5.5mm, 6.5mm (Ref#5001-90013, 5001-90014, 5001-90015) Product Usage: The K2M Fenestrated Tap System is intended for use as a standalone biopsy tool to remove a sample of bone tissue from a vertebral body for diagnostic purposes using an aspiration…
    Category
    Medical Device
    Distribution
    6 states
  • SevereFDA (Devices)·Z-1311-2019·2019-05-29

    Integra MoniTorr CSF Drainage System Recalled for Stopcock Breakage

    Integra LifeSciences is recalling MoniTorr CSF Drainage Systems due to a complaint trend regarding stopcock breakage.

    Product
    MoniTorr INS1100 INS-1100 CSF Drainage System used with Pole Mount System Product Usage: The MoniTorr ICP External CSF Drainage and Monitoring Systems provide a simple to use, closed system for the drainage of cerebrospinal fluid (CSF) from ventricles of the brain or the…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1193-2019·2019-05-29

    Edwards Lifesciences Recalls EV1000 Clinical Platform Due to Fire Hazard

    Edwards Lifesciences is recalling EV1000 Clinical Platform monitors because liquid ingress into AC power outlets could cause an electrical short circuit and fire.

    Product
    EV1000 Clinical Platform, Models: EV1000A, EV1000NI, EV1000CS Product Usage: EV1000A Monitor is used to optimize fluid management through the use of minimally invasive monitoring with the FloTrac sensor (or the Volume View sensor).
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1312-2019·2019-05-29

    Integra LifeSciences Recalls LimiTorr and MoniTorr Stopcock Components

    Integra LifeSciences is recalling LimiTorr and MoniTorr stopcock components due to a complaint trend regarding breakage.

    Product
    LimiTorr INS9020 INS-9020 LIMITORR VOLUME LIMITING EVD 20 ML LimiTorr INS9020SP1 INS-9020SP1 LIMITORR VOLUME EVD 20ML LimiTorr INS9030 INS-9030 LIMITORR VOLUME LIMITING EVD 30 ML LimiTorr INS9030SP1 INS-9030SP1 LIMITORR VOLUME LIMITING EVD 30 ML Product Usage: The…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1383-2019·2019-05-29

    Beckman Coulter Recalls UniCel DxH 600 Hematology Analyzers for Platelet Errors

    Beckman Coulter is recalling 2,059 UniCel DxH 600 hematology analyzers because they may produce erroneously elevated platelet results without warning, potentially masking low platelet counts.

    Product
    UniCel DxH 600 Coulter Cellular Analysis System, REF number B23858. Product Usage: Note: The DxH 600 hematology analyzer is the same instrument as the DxH 800 (K140911), except that it is a benchtop unit with no instrument cart, computer stand, and no connectivity…
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1382-2019·2019-05-29

    Beckman Coulter UniCel DxH 800 Hematology Analyzer Recall for Platelet Errors

    Beckman Coulter is recalling UniCel DxH 800 analyzers because sporadic platelet results may be erroneously elevated without system flags, potentially leaving thrombocytopenia unrecognized.

    Product
    UniCel DxH 800 Coulter Cellular Analysis System, REF numbers 629029, B24465, B24802, B68304, B66445, and B63322. Product Usage: The UniCel DxH 800 Analyzer is a quantitative multi-parameter, automated hematology analyzer for in vitro diagnostic use in screening patient…
    Category
    Medical Device
    Distribution
    Distributed nationwide