The Recall Desk

Recalls

All US Product Recalls

Searchable archive of product recalls from the FDA, USDA FSIS, CPSC, NHTSA, and EPA — translated into plain English, severity-scored from objective criteria, and always linked back to the original government notice.

How to read this listing

Every recall on this list has been scored 1–5 against an objective rubric from the agency’s own classification, presence of reported injuries or deaths, distribution scope, and hazard type. The colored severity badge on each card is the score — 5 (Critical) means deaths or serious injuries are reported, 4 (Severe) means significant injury or hospitalization risk, and 3 (High) means a known hazard with no confirmed harm yet. Filter to 3+ (High and above) if you want to skip routine Class-III notices.

The agency chips above control which streams are visible. FDA spans food, drugs, and medical devices. USDA FSIS is meat, poultry, and processed egg products. CPSC is household consumer products. NHTSA is vehicles, tires, and child seats. Nationwide on a card means the recall affects every US state — most do — while a state list means distribution was limited.

Click any recall to see the full summary, affected lot codes and model numbers, the agency’s own classification, and a direct link back to the original government notice for verification.

Filters

Agency

Category

Minimum severity

Clear filters

6926–6950 of 13652

  • SevereFDA (Devices)·Z-1274-2024·2024-03-27

    Smiths Medical Pneupac paraPAC plus 310 ventilators recalled for malfunction

    Smiths Medical is recalling paraPAC plus 310 ventilators that may malfunction by delivering continuous gas flow instead of cycling breaths. The defect affects 10,140 units distributed worldwide and prevents proper ventilation.

    Product
    smiths medical Pneupac paraPAC plus 310 ventilator kit with PEEP and CPAP, REF P310NUS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1300-2024·2024-03-27

    FDA Recalls HeartMate II Left Ventricular Assist Systems for Graft Obstruction

    Thoratec Corp. recalls HeartMate II left ventricular assist system kits due to outflow graft deformation that could obstruct blood flow. The FDA has classified this as a Class I recall affecting 2,240 units distributed worldwide.

    Product
    HeartMate II Left Ventricular Assist System (LVAS): 1. HeartMate II Sealed Outflow Graft with Bend Relief REF 103393 2. HeartMate II LVAS Implant Kit, US REF 106015 3. HeartMate II LVAS Implant Kit, OUS REF 106016 Update (February 14, 2024) HeartMate II Left Ventricular As
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1267-2024·2024-03-27

    ARROW QuickFlash Radial Artery Catheters Recalled for Defective Component

    ARROW International is recalling 1,160,470 QuickFlash radial artery catheterization devices due to a defective guidewire handle that can cause arterial vasospasm and vessel injury.

    Product
    ARROW QuickFlash Radial Artery Catherization (wire, guide, catheter), Part Numbers: a) REF AK-04220; b) REF ASK-04220-FMH1; c) REF ASK-04220-HHC; d) REF ASK-04220-KSP; e) REF ASK-04220-PSU; f) REF ASK-04220-UCL1; g) REF ASK-04500-AH; h) REF ASK-04500-HF-S; i) R
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1275-2024·2024-03-27

    Smiths Medical Pneupac Plus 300 Ventilator Cycling Malfunction

    Smiths Medical Pneupac Plus 300 ventilators may intermittently deliver continuous airflow instead of cycling breaths as designed. This malfunction affects 2,902 units distributed worldwide.

    Product
    smiths medical Pneupac paraPAC plus 300 ventilator kit without PEEP and CPAP, REF P300NUS
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • SevereFDA (Devices)·Z-1301-2024·2024-03-27

    HeartMate 3 Left Ventricular Assist System recalled for outflow graft obstruction

    The FDA is recalling the HeartMate 3 Left Ventricular Assist System due to observed outflow graft deformation that can obstruct blood flow. Patients with implanted devices should contact their healthcare provider.

    Product
    HeartMate 3 Left Ventricular Assist System (LVAS): 1. HeartMate 3 Sealed Outflow Graft with Bend Relief, Investigational Device Exemption (IDE) 2. HeartMate 3 Sealed Outflow Graft with Bend Relief, US 3. HeartMate 3 Sealed Outflow Graft with Bend Relief, OUS 4. HeartMate 3 LV
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1303-2024·2024-03-27

    Access Total T4 thyroxine assay recalled for test imprecision

    Beckman Coulter recalls Access Total T4 thyroxine assay due to imprecision that may cause erroneous or delayed diagnostic results.

    Product
    Access Total T4, REF 33800, IVD, thyroxine reagent assay.
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1345-2024·2024-03-27

    MINI STICK MAX guidewire introducer defect may prevent sheath passage during procedures

    Angiodynamics is recalling MINI STICK MAX guidewire introducers (155 units) due to manufacturing defects in the sheath hub that may prevent guidewire passage.

    Product
    MINI STICK MAX 5F X 10 CM STD .018 SS/SS ECHO 1.6" PG- Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-774
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1319-2024·2024-03-27

    I.B.S. 6.5-C Compression Screw Batch Recalled for Dimensional Mix-Up

    A batch of I.B.S compression screws may have incorrect dimensions compared to their labels due to a batch mix-up. The 59 affected units were distributed nationwide in Tennessee.

    Product
    I.B.S¿ 6.5-C Compression screw - diam 6.5mm lg 75mm,Part Number S65 ST175
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1348-2024·2024-03-27

    Guidewire Introducer Sheath Recalled for Internal Lumen Voids

    Angiodynamics is recalling 39 units of MINI STICK MAX vascular guidewire introducers due to voids in the sheath hub that may prevent guidewire passage during surgery, potentially delaying the procedure.

    Product
    MINI STICK MAX 4F X 10CM STIFF .018 NI/TU ECHO 1.6" PG- Used for the percutaneous introduction of a guidewire into the vascular system. - Catalog Number: 45-781
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1341-2024·2024-03-27

    Angiodynamics Guidewire Introducer Recall Due to Manufacturing Defect

    Angiodynamics recalls approximately 5,840 guidewire introducers with manufacturing defects that may prevent proper guidewire insertion during vascular procedures. The defect could cause procedural delays requiring equipment exchange.

    Product
    MINI STICK MAX 5F X 10 CM STIFF .018 NI/TU ECHO 2.75" PG-Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-759
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1332-2024·2024-03-27

    Directional Laser Probe Recall Due to Fiber Extension and Direction Malfunction

    A Class II medical device recall has been issued for Directional Laser Probes due to potential difficulties extending, retracting, and directing the laser fiber tip. The issue affects 126 units distributed across multiple US states.

    Product
    Directional Laser Probe with Alcon / Lumenis connector (25 gauge / 0.5 mm)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1330-2024·2024-03-27

    Laparotomy Sponges recalled for incomplete sterilization and missing RF detection

    Covidien is recalling Situate Laparotomy Sponges because some packs may contain improperly sterilized units lacking required RF detection features. Non-sterile sponges could cause infection, tissue trauma, and sepsis during surgery.

    Product
    Situate Laparotomy Sponge, RF and X-ray Detectable, REF: L1818-04P01C-1
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1314-2024·2024-03-27

    Abbott Point of Care Control Device Recalled Due to Temperature Storage Failure

    Abbott's i-STAT Level 1 control device is recalled because a refrigerator temperature excursion on January 8, 2024, could cause incorrect or delayed test results. The walk-in storage unit failed, causing temperatures to fall below the required range of 35.6-46.4°F.

    Product
    Abbott Point of Care Control Control i-STAT¿ Level 1 10 X 1.7 mL
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1329-2024·2024-03-27

    Hip Traction Boot Assembly Defect Could Cause Device Detachment

    Baxter Healthcare is recalling HDS Traction Boot II units due to incorrect assembly. The boot key socket locking ridge faces upward, preventing proper attachment to the traction system.

    Product
    HDS Traction Boot II, REF AR-6529-23, The Traction Boot is designed to position, support and/or distract the patient's foot for hip surgery
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1331-2024·2024-03-27

    Directional Laser Probe Recalled for Fiber Extension and Direction Difficulties

    D.O.R.C. Dutch Ophthalmic Research Center is recalling Directional Laser Probes for ophthalmic surgery due to difficulties extending, retracting, and directing the laser fiber. The recall affects 84 units distributed nationwide.

    Product
    Directional Laser Probe with Alcon / Lumenis connector (23 gauge / 0.6 mm)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1318-2024·2024-03-27

    TMINI Knee Instrument Array Guide May Bind During Surgical Drilling

    A precision component in Think Surgical's TMINI robotic knee system may bind due to insufficient clearance. The binding could occur during surgical drilling.

    Product
    Assembly, Array Guide TMINI, REF: 109101, part of the TMINI Knee Instrument Set, used with the TMINI Miniature Robotic System
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1343-2024·2024-03-27

    Vascular Guidewire Introducer Sheath Recalled for Internal Hub Defect

    Angiodynamics recalls 130 MINI STICK MAX guidewire introducers due to hub voids that may prevent guidewire passage during vascular procedures. No injuries reported.

    Product
    MINI STICK MAX 5F X 10 CM STD .018 SS/SS NON-ECHO 2.75" PG- Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-765
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1342-2024·2024-03-27

    Surgical Guidewire Introducer Sheath Recalled for Internal Manufacturing Defects

    Angiodynamics vascular guidewire introducers (600 units) may have internal defects preventing proper function during surgery. Defects could cause procedure delays and require device exchange.

    Product
    MINI STICK MAX 4F X 10 CM STIFF .018 NI/TU NON-ECHO 2.75" PG- Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-762
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1320-2024·2024-03-27

    Medical Device Recall: Orthopedic Compression Screws with Incorrect Dimensions

    In2Bones, SAS is recalling I.B.S Compression screws due to a batch mix-up. Affected screws may have different lengths than indicated on their labels, creating a risk of improper surgical implantation.

    Product
    I.B.S¿ 6.5-C Compression screw - diam 6.5mm lg 80mm,Part Number S65 ST180
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1340-2024·2024-03-27

    Vascular Guidewire Introducer Recalled Due to Internal Hub Defect

    A vascular guidewire introducer is recalled because internal voids in the hub may prevent proper guidewire passage, potentially delaying surgical procedures.

    Product
    MINI STICK MAX 5F X 10 CM STIFF .018 SS/PD ECHO 2.75" PG-Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-758
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1333-2024·2024-03-27

    Directional Laser Probe Recalled for Fiber Extension and Direction Failure

    D.O.R.C. recalls 78 directional laser probes with Alcon/Lumenis connectors due to difficulties extending, retracting, or directing the laser fiber. The Class II recall affects units distributed across multiple U.S. states and Puerto Rico.

    Product
    Directional Laser Probe with Alcon / Lumenis connector (27 gauge / 0.4 mm)
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1334-2024·2024-03-27

    Vascular guidewire introducer recalled for manufacturing defect

    Angiodynamics recalls MINI STICK MAX vascular guidewire introducers due to internal lumen defects that may prevent the guidewire from passing through during surgery, potentially requiring device exchange.

    Product
    MINI STICK MAX 4F X 10 CM STD .018 SS/PD ECHO 2.75" PG-Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-749
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1337-2024·2024-03-27

    Guidewire Introducer Recalled for Manufacturing Defect Affecting Device Function

    Angiodynamics is recalling 58 units of its MINI STICK MAX guidewire introducer due to voids in the internal lumen that may prevent proper guidewire passage. Users may experience procedural delay requiring device exchange.

    Product
    MINI STICK MAX 4F X 10 CM STIFF .018 SS/PD ECHO 2.75" PG-Used for the percutaneous introduction of a guidewire into the vascular system. Catalog Number: 45-752
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1317-2024·2024-03-27

    Medtronic Abre Venous Stent System Recalled for Sterile Package Breach

    Medtronic is recalling Abre Venous Self-expanding Stent Systems due to a potential for sterile package breach. The recalled systems consist of three product numbers totaling 65 units distributed worldwide. No injuries have been reported.

    Product
    Abre Venous Self-expanding Stent System, Product Numbers: a) AB9U14080090; b) AB9U18100090; c) AB9G14100090
    Category
    Medical Device
    Distribution
    Distributed nationwide
  • HighFDA (Devices)·Z-1307-2024·2024-03-27

    Nasal Intubation Kit Recalled for Incompatible Tube Holder

    Curaplex Nasal Intubation Kit recalled because the included endotracheal tube holder is incompatible with nasal intubation procedures, preventing practitioners from properly securing the tube.

    Product
    Curaplex Nasal Intubation Kit with 6mm Endotrol Tube-To perform a nasal intubation to establish an airway in an emergency. Item Number: 023060S
    Category
    Medical Device
    Distribution
    Distributed nationwide